Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.1 LAccepted-AOC | L1 | Accepted-AOC AS PER BOQ | |
| 2 | L2₹14.3 L+₹1.0 L (7.80%)Rejected-AOC | L2 | Rejected-AOC AS PER BOQ | |
| 3 | L3₹14.8 L+₹1.5 L (11.1%)Rejected-AOC | L3 | Rejected-AOC AS PER BOQ | |
| 4 | L4₹14.9 L+₹1.6 L (12.3%)Rejected-AOC VILLAGE POST JAGANOO TEHSIL UDHAMPUR JAGANOO UDHAMPUR1 UDHAMPUR JAMMU KASHMIR 182124 UDYAM JK 22 0011509 | UDHAMPUR | JAMMU AND KASHMIR | 182124 | L4 | Rejected-AOC AS PER BOQ | |
| 5 | L5₹17.7 L+₹4.4 L (32.9%)Rejected-AOC 15 BOH ROAD DEFENCE ENCLAVE AMBALA CANTT 133001 HR | AMBALA | HARYANA | 133001 | L5 | Rejected-AOC AS PER BOQ |
Tender Value
₹19.3 L
EMD Value
₹38,600
Closing Date
7 Sept 2020, 6:00 pmClosed
GE Army Dhar Road Udhampur
GE Army Dhar Road Udhampur
Special repair to Bldg No P-46 at Dhar Road and Special repair replacement of PVC tank in Gandhira water point at Jindrah under GE Army Dhar Road Udhampur
2020_MES_368646_1
8066/NIT-36/2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
Jindrah and Dhar Road under GE Army Dhar Road Udh
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
Yes
GE Army Dhar Road Udhampur
₹38,600
Yes
16 Oct 2020
12 Aug 2020
9 Sept 2020
12 Aug 2020
7 Sept 2020
24 Aug 2020
12 Aug 2020 - 23 Aug 2020
Amount
Taking down existing roof treatment of any description and any type complete all as specified and directed by Engr-in-Charge.
M&L for 15 mm thick cement plaster in cement mortar 1:4 on roof surfaces finished even and smooth without using extra cement mixed water proofing compound complete all as specified and directed. (WPC shall be measured and paid for separately as supply only).
Roughening surfaces of old concrete floor by picking, sweeping cleaning and washing down with water to remove dust etc and brushing neat cement slurry @ 3.00 Kg of cement per sqm complete all as specified and directed
Supply only liquid water proofing compound (Make :Pidilite Industries /Impermo/Snowcem India Ltd/Sika )
Priming the roof surface with bituminous primer conforming to IS-3384 @ 0.30 ltrs/Sqm and applying a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.20 Kg/Sqm and thereafter providing polymeric water proofing membrane (five layered) of weight not less than 3 Kg/Sqm with centre layer core of 90 micron high molecular density polyethylene film followed by another coat of semi hot blown 85/25 grade bitumen @ 1.20 Kg/Sqm blinded with fine sand in dry condition @ 0.50 Kg/Sqm all as specified (Make of polymeric water proofing membrane : M/s IWL India Ltd/M/s STP Texas Ltd/Bengal Bitumen)
M&L for providing and laying 40mm thick PCC 1:2:4 type B1 using 20mm graded agg mixed with WPC complete all as specified and directed by Engineer-in-Charge. (WPC shall be measured and paid for separately as supply only).
M&L benching with PCC 1:2:4 type B0 using WPC along side wall adjoining to roof in concave shape complete all as specified and directed. (WPC shall be measured and paid for separately as supply only).
Dismantling wall and ceiling boards, (fibre pulp, insulation etc) or insulation boards any thickness including cover fillets complete all as specified and directed.
M&L for providing & fixing false ceiling with Gypsum based ceiling tiles and frame work (with aluminum foil on one side) of size 595 x 595 mm of thickness not less than 9 mm including with GI powder coated frame angle /tee grid frame work for ceiiling with following specfications (a) Angle of size 25x25x1mm powder coated (b) 25x25x1 mm GI powder coated at bottom tee as in main member (c) 25x25x1 mm thick GI powder coated at bottom tee as in cross members (d) 1.6mm dia GI wire suspenders alongwith adjustable clamps to maintain leveling inculding fixing to ceiling fasteners as per manufacturer's instructions complete all as specified and directed. MAKE: VINYL TOUCH of LaGyp (LAFARGE) or equivalent in GYPROC (SAINT GOBBAIN).
M&L for vitrified ceramic tiles light shade 9 to 10mm thick (square/ rectangular) polished, area of each tiles not exc 0.36sqm in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 20mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
M&L for vitrified ceramic tiles 10mm thick dark shade (square/ rectangular) polished, area of each tiles not exc 0.36sqm in vertical surfaces such as skirting/dados etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 on brick or concrete surfaces complete all as specified and directed.
Diismantling floor, hearth or wall tiles incluidng cement mortar bedding complete all as specified and directed.
Taking down cement plaster including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for 15mm thick rendering in patches in cement mortar 1:6 on other than fair faces of brick work or concrete surfaces and finishing the surface even & smooth without using extra cement complete all as specified and directed.
M&L for 15mm thick rendering in patches in cement mortar 1:4 mixed with integral water proofing compound on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. (WPC shall be measured and paid for separately as supply only).
M&L for 5mm thick rendering in cement mortar 1:3 on ceiling surfaces finished even and fair without using extra cement complete all as specified and directed.
M&L for preparing new plastered surfaces and applying two coats of OBD over a coat of alkali resistant primer of any description of approved tint cement complete all as specified and directed.
M&L for two coats of cement base paint on newly plastered surfaces of wall over a coat of alkali resistant cement pimer including preparation of surfaces cement complete all as specified and directed.
M&L for applying three coats of white wash on newly plastered surface of ceiling cement complete all as specified and directed.
M&L for complete removal of existing treatment of ceiling and applying two coats of white wash on old plasterd ceiling surfaces cement complete all as specified and directed.
M&L for complete removal of existing treatment on walls by scraping, sand papering or by using mechanical sander and preparing plastered surfaces and applying two coats of oil emulsion distemper of approved tint on walls by using roller/sprayer complete all as specified and as directed by Engr-in-Charge.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for cement complete all as specified and directed.
M&L for 50 mm thick plain cement concrete type C2 1:3:6 using 40 mm graded aggregates as in plinth protection laid in alternate bays (not exceeding 2 Sqm each) finished even and smooth at top without using extra cement and providing joints throughout the thickness of plinth protection, filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight cement complete all as specified and directed.
S&F PVC(SWR) pipes, 110 mm external dia double socketed in any length with rubber joints, fixed to walls/under floors with PVC brackets/clips, pipe under floor will be coverd in PCC 1:3:6 including dismantling of existing CI/AC/PVC pipe with fitting cement complete all as specified and directed.
S&F PVC(SWR) bends suitable for 110 mm external dia cement complete all as specified and directed.
M&L for complete removal of existing treatment on wall, ceilling etc by scraping, sand papering or by using mechanical sander and preparing plastered surfaces and applying two coats of cement base paint of approved tint on walls by using roller/sprayer complete all as specified and as directed by Engr-in-Charge.
S&F rotational moulded polyethylene water storage tanks of 500 ltrs capacity three layered in whitr colour ISI marked (cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including dismantling of existing water tank complete all as specified and directed.
S&F 20 mm ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe and fixed. (Minimum weight 20mm - 210 gms) etc complete.
S&F in repairs 20mm gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repairs 15mm gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F 15mm bore GI pipe medium grade galvanised with all fittings fixed to walls, laid in floors and ceilings etc including taking up or down old steel tubing and connections complete all as specified and directed.
S&F 20mm bore GI pipe medium grade galvanised with all fittings fixed to walls, laid in floors and ceilings etc including taking up or down old steel tubing and connections complete all as specified and directed.
S&F 4mm thick sheet glass ordinary quality and glazing with oil putty in squares n. exc 0.50 Sqm in each pane including hacking out old broken glass (any thickness, size, quality or description ) from wooden frames or stone, concrete or brick surrounds galzed with putty or fixed with beads complete all as specified and directed.
All as per srl item No 33 above but figured glass, pin head type complete all as specified and directed.
M&L one coat of synthetic enamel paint over old painted steel & iron surfaces of any description, not otherwise described, over 10 cm in width or girth, including preparation of surfaces complete all as specified and directed.
M&L one coat of synthetic enamel paint over old painted wood and wooden based surfaces of any description, not otherwise described over 10 cm in width or girth, including preparation of surfaces complete all as specified and directed.
M&L for one coat of exterior emulsion paint (Weather Coat) on roof boarder, drops, fins, chajja / roof facia, column etc, including preparation of old surfaces complete all as specified and directed.
S&F rotational moulded polythene water storage tanks, three layered, ISI Marked (Cylindrical vertical with closed top) hoisted and fixed in position of capacity 10000 ltrs including taking down old unserviceable tank any type complete all as specified and as directed.
S&F GI tubing medium grade 80 mm bore complete with all accessories such as tees, bends, short bends, nipples with flanged/ socket type joints etc including cutting welding connecting and fixed on plinth including taking down existing pipe complete all as specified and as directed.
S&F 80mm dia cast iron sluice valve class PN 1.6 both ends flanged in existing line, after removal of old unserviceable sluice valve without damaging to existing pipe line, fixed as in repair including dismantling and taking down old unserviceable sluice valve complete all as specified and as directed
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and as directed.
M&L hardcore of stone boulder of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for 100 mm thick, cement concrete type D2,1:4:8 using 40mm graded aggregates, finished even & rough, as in sub floors, complete all as specified and as directed.
M&L for PCC 1:2:4 type B2 using 40mm graded stone aggregrates as in filling & mass concrete, complete all as specified and as directed.
M&L for 15mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for three coats of white washing on undecorated wall surfaces, including preperation of surfaces complete all as specified and directed.
M&L brickwork using old size sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed.
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in hard/ dense soil complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material exc 250 m and not exc 500m and deposited where directed complete all as specified and directed.
Taking down old unserviceable/deteriorated batten/PVC conduit point wiring aluminium/ copper from existing place i.e. light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets,bell push , ceiling rose, pendants, Holders, etc and making good all disturbed surface to wall, floor etc by means of cement mortar (1:3) or plaster of Paris and to match / finish new surface as the existing surface either by using same colour distemper, Putti or white / colour wash all as required and directed by Engineer-in-Charge.
M&L for concealed point wiring on wall and ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screws and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of Paris/ Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge for the following:-
One light / Fan / Bell point controlled by one way switch 6 Amp .
One 3 pin socket outlet 5 Amps on the same board with other switches
One 3 pin 5 Amp socket out let controlled by one switch on independent board
M&L for point wiring for Power point contolled by one 15 Amp switch independent with PVC insulated and unsheathed multistranded FRLS copper conductor single core 2.5 Sqmm (nominal area) cable using approved colour code as per IS drawing in and incl PVC casing and capping(ISI Mark) with all accessories including providing sunk cast pressed steel terminal boxes off size made out of 1.5mm thick MS sheet duly painted with black bitumen paint over a coat of red oxide primer and providing 3 mm thick plastic laminated bakelite sheet(HYLUM BRAND) top cover alongwith copper earth wire PVC insulated & unsheathed multistranded(FRLS) copper conductor cable of size 1.5 Sqmm as continous earth wire connected to common earth and erth dolly complete all as specified and as directed. Make of wire : Finolex/Havells/Polycab.
S&F switch piano flush type (ISI marked), single pole, one way 5 Amp, 240 Volts complete all as specified & directed. Make : Havells/Anchor/Legrand/SSK
S&F switch piano flush type (ISI marked), single pole, one way 16 Amps, 240 Volts complete all as specified & directed. Make : Havells/Anchor/Legrand/SSK
S&F socket outlet 2 in 1, 3 pin, 6 Amp piano complete all as specified & directed. Make : Havells/Anchor/Legrand/SSK
S&F socket outlet, 2 in 1, 3 pin 16/15 Amp, piano flush type complete all as specified & directed. Make : Havells/Anchor/Legrand/SSK
M&L for lamp holder insulated body with back plate suitable for batten fittings complete all as specified & directed. Make : Havells/Anchor/Legrand/SSK
S&F ceiling rose, surface bakelite, 65mm x 50mm , three terminals complete all as specified & directed. Make : Havells/Anchor/Legrand/SSK
S&F wall mounted LED batten 18/20 Watt with 01 No LED tube rod, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver includingdismantling unsv FTL fitting T8 type any type complete all as specified and directed. Make: Crompton cat part No DMLN1LT8-16 LT5RT-18-CDL / Bajaj Cat Part no BLRB-DB 118 & BLRB 18W CWc XE or equivalent in Phillips /OSRAM
S&F LED building security light 35 watt,230V complete with all accessories and including connecting up to celling rose with 0.5 sqmm three core copper flexible conductor cable, one GI medium grade suitable size dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastener inc dismantaling taking down unsv fitting any type all as specified and directed. Make- Wipro Cat Part No LR02-391xxx-57-xx or equivalent in CG/Phillips.
S&F LED lamp 10 watt, CDL, B-22 cap, (Pin type), 230V, PF not less than 0.85 (min) incl . Make-Havells/CG/Bajaj/ Philips
S&F medium step type fan regulator , 240 Volt AC, socket size, medium step" ISI marked complete all as specified and directed. make Cona / Anchor/Havells/Crabtree
S&F of recess mounted mirror optic LED luminaire fitting not less than 100 lumen/watt , 30 watt, dimention 600mm x 600mm fitting for grid type ceiling including control driver and other accessories complete all as specified and directed. Cat No LCTLRNE-36-FO-CDL OF MAKE CROMPTON OR EQUIVALENTS OF Philips/wipro/Havells
S&F MCB, single pole 'C' series having braking capacity 10 KA, 6 to 32 Amp, 240 volts, complete all as specified & directed. Make : Legrand/Schneider/Havells
S&F MCB SPN having braking capacity 10 KA 35-60 Amp, 240 Volt 'C' Curve complete all as specified and directed. Make : Legrand/Schneider/Havells
S&F sheet metal enclosure with double door for DBs conforms to IS:8623.III , IP:43 protection, shrouded neutral link & earth bar and cement spill protector, 8 way, 240 Volt . Make : Legrand/Schneider/Havells
M&L for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 6.0 sqmm (Nominal area) drawn through in and including PVC concealed conduit of appropriate size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLS Copper conductor cable of size 4.0 sqmm as earth lead and connected to earth dolly and making good to disturbed surfaces all as specified and directed. Make of wire : Finolex/Havells/Polycab. NOTE: (a)Two run of cable with one run of earth wire and one run of PVC conduit will be measured as one length.
Earthing complete with galvanised iron earth electrode plate of size 600x600x6mm thick, buried directly in ground (earth pit nbot less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below notmal ground level, connected to galvanised earth lead wire 4.0mm dia by means of suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 25mm bore with funnel wire mesh and medium grade GI wire protection pipe 25mm bore up to main board complete as shown in electrical plate No 3 of MES schedule Part-I 2009, connected to earthing testing point including taking out existing unsv earthing complete all as specified and testing on completion complete ass as specified and directed .Note - The unit rate includes the cost of excavation & earth work in any type of soil, charcoal & salt in alternate layers, 25mm GI pipe (light grade) for watering 25mm GI protection pipe (light grade) funnel wire mesh PCC chamber in PCC 1:3:6 type C-1 cast iron frame and 40mm thick RCC cover for pit etc.
S&F ceiling fan 230 Volts complete with accessories with 1200mm sweep and assembling the same at site complete including supplying and fixing PVC insulated twisted 3 core 23/0.0076 copper conductor flexible PVC insulated wire of required length from connector to fan, painting MES Number with black bold letters with synthetic enamel paint upto 2.50 cm high complete all as specified and directed by Engineer-in-Charge.
SUBASH CHANDER
S.K CONSTRUCTION
NARESH KUMAR KHAJURIA
MAHADEV ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .