| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹35.5 L+₹4.1 L (13.0%)Rejected-Finance H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹36.3 L+₹4.8 L (15.3%)Rejected-Finance WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | L3 | Rejected-Finance BEING L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical Rejected due to non adequate category | |
| 5 | Rejected-Technical 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | - | Rejected-Technical Rejected due to non adequate category |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
30 Nov 2019, 6:00 pmClosed
GE (AF) PALAM
GE (AF) PALAM , DELHI CANTT-110010
CA NO. GENP-48/2019-20 REPAIRS / MAINTENANCE OF DG SET, FIRE FIGHTING, VOLTAGE STABILIZER AND CONNECTED ITEMS INSTALED AT WATER SUPPLY INSTALLATION AT AF STATION PALAM AND REPAIR OF AIR CONDITIONER, WATER COOLERS AND DESERT COOLERS AT TECHNICAL
2019_MES_294192_1
GENP-48/2019-20
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (AF) PALAM
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
Yes
GE (AF) PALAM
₹98,000
Yes
18 Jul 2020
1 Nov 2019
2 Dec 2019
2 Nov 2019
30 Nov 2019
16 Nov 2019
Amount
Servicing of window type AC 1.5/2 TR capacity including oiling greasing of fan motor replacement of synthetic filter & checking of electric circuit for smooth functioning of AC (S&F of unserviceable burnt spare parts of machien shall be meaured and paid for separately under repsective items) complete all as specified
All as per item No 1 above but split AC of 1.5/2 TR
Supply & fixing in replacement of starting relay suitable for 1.5 TR/2TR capacity AC make: Classic/Renutrol
S&F in replacement of over load protector suitable for 1.5/2.0 TR capacity Make: Classic/Renutrol
S &F in replacement of starting capacitor 80-100 mfd suitable for 1.5 ton capacity/AC make Tesla/Usha/GDR/Tibcon/EPCOS
All as per item No 5 above but 100-120 mfd suitable for 2.0 ton capacity
S&F in replacemernt of capacitor 36 mfd suitable for 1.5 capacity Ac Make: Usha/Asian/Tibcon/EPCOS
All as per item No 7 above but 45 mfd suitable for 2.0 ton capacity
All as per item No 7 above but 45 + 6 mfd suitable for 1.5 ton capacity
All as per item No 7 above but 50+6 mfd suitable for 2.0 ton capacity
All as per item No 7 above but 60 + 6 mfd suitable for 2.0 ton capacity
S&F in replacement of wiring kit suitable for 1.5/2 Ton capacity /Window AC complete all as specified and directed
S&F in replacement of wiring kit suitable for 1.5/2 Ton capacity Split AC complete all as specified and directed
S&F in replacement of thermostate switch suitable1.5/2 Ton capacity AC complete all as specified and directed
S&F in replacement of front grill suitable for 1.5/2.0 TR capacity of window AC
All as per item No 16 above but base plate suitable for 1.5/2.0 TR capacity of window AC
All as per item No 16 above but motor capacitor 6 mfd Asian/Tibcon/EPCOS
S&F in replacement of metal clad socket 20 Amp Make; Crompton/Havells
All as per item No 19 above but metal clad plug. Make Crompton/Havells/Philips
Taking out unserviceable fan-cum-blower motor and M&L for rewinding and repairing of fan-cum-blower motor of w2indow tpe AC 1.5/2.00 TR capacity with supper enamelled copper winding wire of existing gauge complete all as specified and directed by Egnineer-in-charge
All as per item No 21 above but fan motor for split type AC 1.5/2.0 TR
All as per item No 21 above but blower motor for split type AC 1.5/2.0 TR
M&L for taking out and M&L for rewinding/repairing unserviceable reciprocating type compressor suitable for 1.5 TR window/split AC, Re-fixing on its original position and testing for smooth funcitioning, Make:- Techumesh/Usha Shriram/Emerson Copeland/Carrier. Note:- (1) Supply and charging gas shall be measured and paid separtely under respective item of schedule. (ii) Contractor will make own alternate arrangement to run the AC during the period of compressor repair.
All as per item No 24 above but for 2 TR capacity
S&F new reciprocating type compressor of capacity 1.5 TR in replacement to unserviceable compressor Make: Emerson copeland/Tecumesh /Carrier. Charging of gas shall be paid separately undre respective item)
All as per item No 26 above but capacity 2.0 TR
"S&F new fan-cum-blower motor with propeller, fan blade, rubber seal, holding clamps nuts & bolts for 1.5/2 TR window AC in replacemnt to unserviceable motor make AUE/ANU/GE Motors/Marathan
S&F new blower blade for 1.5/2 TR window AC in replacement of old unserviceable fan blade.
S&F new fan blade for 1.5/2 TR window/split AC in replacement of old unserviceable fan blade.
S&F new blower for 1.5/2 TR split AC in replacement of old unserviceable blower
Supply & charging the refrigerant gas R-22 to window/split type AC upto 2 TR capacity including test complete all as specified and directed
Supply & charging the refrigerant gas R-410A to split type AC upto 2 ton capacity including testing complete all as specified and directed by Engr-in-charge
S&F in replacement of MCB 20 to 32 Amps cap 230 volt AC supply make: MDS/Havells
Supply & fix sheet metal single pole and neutral enclosure with a two pin and earth plug and socket compelte with one signle pole MCB 20 Amps Make: Havells/Crompton
S&F condensor with copper tubing and aluminium fins suitable for 1.5/2.0 TR window AC in replacement of old unserviceable condenser
S&F condensor with copper tubing and aluminium fins suitable for 1.5/2.0 TR split AC in replacement of old unserviceable condenser
S&F new rotary type compressor of capacity 1.5 TR sunitable for working on R-22 Refrigerant in replacement to unserviceable compressor make: Mitsubhishi/Tech mesh product/LG Hitach (Charging of gas shall be paid separately/under respective item)
All as per item No 38 above but 2.0 TR
S&F new rotary type compressor of capacity 1.5 TR sunitable for working on R-410 A refrigerant in replacment to unserviceable compressor Make: Mitsubishi/Techmesh/LG/HiTachi/Carrier (Charing of gas shall be paid separately under respective item)
All as per item No 40 above but capacity 2.0 TR
Supply & fix in replacement new PCB card suitable for 1.5/2. 0 TR capacity of split Acs including suitable for invertor AC's of said capacity complete all as specified and directed
M&L for repairing of PCB card suitable for 1.5/2 TR capacity of split AC's complete all as specified and directed
Supply & fix in replacement new swing motor suitable for 1.5/2.0 TR capacity of window/Split AC complete all as specified and directed
Supply & fix in replacemnt of PVC drain pipe 15mm dia with fittings and fixing accessories complete all as specified and directed
Labour only to convert split AC 1.5/2.0 TR from cooling mode to heating mode by heating element/reverse solenoid valve arrangement wiring interlocking as requried complete all as specified and directed
S&F reverse valve suitable for split type AC 1.5/2.0 TR including additional copper tubing of any size brazing work, presure testing dehydration gas charging upto required level and necessray modification in remote control unit for satisfactory function of unit in heating mode complete all as specified and directed
S&F condensor with copper tubing and aluminium fins suitable for 1.5/2.0 TR window type AC suitable for working on R-22 Refrigerant in replacement of old unserviceable condenser. Note-Supply and filling of refrigerant gas shall be measured and paid separately undrer respective item of this schedule
All as per item No 48 above but split type AC's
S&F cooling coil with copper tubing and aluminium fins suitable for 1.5/2.0 TR window type AC suitable for working on R-22 Refrigerant in replacement of old unserviceable condenser. Note-Supply and filling of refrigerant gas shall be measured and paid separately undrer respective item of this schedule
All as per item No 50 above but split type Acs
S&F condensor with copper tubing and aluminium fins suitabel for 1.5/2.0 TR split tpe AC suitable for working on R-410A refriegrant in replacement of old unserviceable condenser. Note: Supply & filling of refrigerant gas shall be measured and paid separately under respective item of this schedule
S&F cooling coil with copper tubing and aluminium fins suitabel for 1.5/2.0 TR split tpe AC suitable for working on R-410A refriegrant in replacement of old unserviceable condenser. Note: Supply & filling of refrigerant gas shall be measured and paid separately under respective item of this schedule
Taking out old perished insulation and M&L for insulating the suction and discharge copper tubing from in door unit to outdoor unit of split type Acs of capacity 1.5/2.0 TR capacity with neoprene foam sleeves incuding sealing by applying adhesive tape fo brown or white colour to avoid minimum contact with atmosphere complete all as specified and directed
Taking out old unserviceable copper tubing and M&L for suctionand discharge copper tubing of size 1/2 inch and 1/4 inch dia and 0.5mm thickness from indoor unit to outdoor unit of split type AC 1.5 TR capacity including soldering and braizing complete all as specified and directed. Note:- Suction and discharge copper tubing together wil be measured as one unit of running metre.
All as per item No 55 above but copper tubing size 5/8 inch and 3/8 inchj dia and 0.5mm thickness
Taking out old unserviceable suction line valve assy of size 1/2" dia from outdoor unit of split tpe AC and S&F new suction including soldering and braizing complete all as specified and directed
All as per item No 57 above but discharge valve assy size 3/8" dia
S&F non metallic PVC conduit exclusive of junction boxes but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks et cof size 20mm dia Make: Kalinga
All as per item No 59 above but 25mm dia PVC conduit
S&F in replacement electric cables PVC insulated rubber sheathed circular multistranded copper conductor of size 2.5sqamm 3 core, Make: National/Havells/Kalinga/Plaza
Supply & fix in replacement of AC stand wall mounted/floor mounted type suitable for existing type/Model of AC's complete all as specified and directed by Engr-in-charge
M& for shifting of window/split AC's from existing loaction into New location dismantling of window/split AC's with electrical connection carefully and transported to New location as directed by the Engr-in-charge and cutting of window grill /brick wall including making good patches both the location & servicing of said AC's including point wiring suitable for window/split AC's not less than 215 sqmm (copper conductor and fixing of plg for window AC's remaining area complete all as specified and directed by Engineer-in-charge
Supply & fix in replacement of indoor unit suitbale existing type capacity of split AC's complete all as specified by Engr-in-charge (1.5/2TR) Make: Voltas/LG/Hi-Tachi
Supply & fix in replacement of outdoor unit suitable for existing type & capacity of split AC's complete all as directed by Engr-in-charge (1.5/2TR) make: Voltas/LG/Hi-Tachi
Taking down copper/aluminimum point wiring (light from, socket or power) complete incuding fixtures and fitings such as switches, ceiling fixturesw and fitting such as swticesh, ceilings, roses, pandants, regulators, sockets, light fittings etc removing matrials to store for keeping in safe cusoty or fan taking credit (credits for above items should be made as per conditions separately() and making good disturbed surfaces of walls, floors etc
M&L for one 3 pin socket outlet 5 Amps indpendent with cable 1.5 sqm size complete all as directed by Engineer-in-charge
M&L for one 3 pin socket outlet 15 amps independent with cabes 4 Sqmm size complete all as specified and directed by Enginer-in-charg
M&L for single pole and neutral enclosure with a two pin and earth plug and socket complete with one singe pole MCB of capacity 20 Amps complete all as specified and directed by Engineer-in-charge
Supply & fix new compresor 1/8 HP suitable for refrigerator of capacity 165 to 200 ltr in replacemnt of burnt defective compressor. The work includes taking out the defective compresor and tsting on completion Make: Techumesh/LG/Whirlpool. Note: (a) Charing of gas R-134 and shall be paid separately under respective item
All as per item No 70 above but refigerator capacity 220 to 320 ltrs
S&F in replacement of evaporator cooling coil of rferigerant 165 to 200 ltrs capacity complete all as speciifed and directed by Egnineer-in-charge
S&F in replacement of evaporator cooling coil of refrigerant 220 to 320 ltrs capacity complete all as specified and directed
S&F in replacement of relay box type/open type suitable for 1/6 to 1/8 HP refrigerator of any make & size (Make Hitech/Renturol
S&F in replacement of overload protector suitable for refrigerator of any make & size complete all as specified and directed
Taing out existing old rusted bottom body and frame door form refrigerator & M&L repariing of any size & capacity or referigerator body bottom and frame door with mild steel flat, angle iron & plainGI sheet of existing gauge by electric welding incuding preparation of surface and painting with spray paint on steel and iron surface of approved make shall be used complete all as specified and directed
M&L for spray painting of refrigerator of any size make with synthetic enamelled paitn (GUCCO Delux paint) 2 coat over existing surface. The work includes surface preparation filling of damaged portion complete all as specified and directed
Taking out burnt defective compressor 1/3 HP from deep freezer of cap 425 ltr & S&F new compresor 1/3 HP capacity suitable for deep freezers 425 ltrs capacity of make Kelvinator/Ashoka including dehydrating of system and charging of comp oil & refeigerant gas complete all as specified and directed Make: Kirloskar/Techumesh)
S&F in replacemernt of thermostatic switch for refrigerator of any make and 165 to 320 ltrs capacity all as specified
Supply & fix in replacemnet door gasket suitable for refrigerator of capacity 165/200 ltr single door
Supply & fix in replacemnt door gasket suitable for refrigerator of capacity 286/300 ltrs single door
Supply & charging the refrigerant gas R-134A in refrigerator of capacity 165 to 200 ltrs including testing complete all as specified and directed
Supply & charging the refrigerant gas R-134A in refrigerator of capacity 200 to 320 ltrs including testing complete all as specified and directed
Supply & charging the refrigerant gas R-134A in deep freezerr of capacity 200 to 425 ltrs including testing complete all as specified and directed
Servicing and cleaning of water cooler 40 to 80 ltf capacity form inside and outside with potassium permaganatse including servicing of fan motor, condensoer, fan balde and ite connected water and refrigerant fitting (S&F of spare parts required for smooth fuctioning of the machine shall be measured and paid for separately under respective items), testing water tank leakage complete all as specified and directed
All as per item No 85 above but capacity 120 to 150 lts
S&F new compressor in replacement suitabel for 40 to 80 ltrs capacity water coolers any make> Re-fixing on its origianl position and testing for smooth functioning. Note: (1) Supply & charging of gas R-22/R-1348 shall be paid separately under respective item.
All as per item No 87 above but capacity 120 to 150 ltrs
M& L for charging refrigerant gas R-22 in the water cooler of any make 40 to 80 ltrs capacity including testing and detecting leakage with nitrogen gas and vaccum the system complete all as specified and directed by Engineer-in-charge
All as per item No 89 above but capacity 110 to 150
M&L for charging refrigerant gas R-134A in the water cooler of any make capacity 40 to 80 ltrs including testing and detecting leakage with nirogen gas and vaccum the system complete all as specified and directed by Engineer-in-charge
All as per item No 91 above but capacity 120 to 150 ltrs
S&F in repalcement of overload relay box tyupe make shriram/renutrol suitable for water cooler complete all as specified and directed by Engineer-in-charge
S&F in replacement of thermostat switch make Danfoss/Renutrol suitable for water cooler of any make and size complete all as directed by Engineer-in-charge
S&F in replacement of starting relay suitable for water cooler make: Usha/Sriram/Renutrol/Classic all as specified and directed by engineer-in-charge
S&F in repalcmeent of overload relay make: Classic/Renutrol No 1022/522 complete all as specified and directed
M&L spray painting of water of cooler of any make 40 to 80 ltrs capacity as per existing coloru (after scraping the old damaged paint making good to the disturbed surface to match with the existing surface) and shade with synthetic enamelled complete all as specified and directed
All as per item No 97 above but capacity 120 to 150 ltr
S&F in replacement of defective push cook 15mm dia chromium plated heavy duty suitable for water cooler of any make capacity complete all as specified and directed by Engineer-in-charge
S&F in replacemnt fo PVC float valve assembly 15mm dia for water cooler of any make 40 to 80 lotrs capacity complete all as specified
S&F in replacement of PVC float valve assembly 15mm dia for water cooler of any make 120 to 150 ltrs capacity complete all as specified and directed
S&F in replacement of running capacitor 25 mfd complete all as specified and diirected by engr-in-charge. Make: Usha/Tibcon/Havells
S&F in replacement of running capacitor 30 mfd complete all as specified and diirected by engr-in-charge. Make: Usha/Tibcon/Havells
M& L in replacement of water cooler base including fabrication with angle iron frame, bottom base MS sheet of 15 gauge including welding brazing repalcemnt of MS hinge half swing of top cover, top gasket all as sper site eqauriement incuding paitning a coat of red oxide primer) as directed by Enginer-in-charge
S&F new fan motor suitable for water cooler of capacity 40 to 80 ltrs complete all as specified and directed
All as per item No 105 above but capacity 120 to 150 ltrs
S&F in replacement of aluminium fan blade suitable for 40 to 80 ltrs of water cooler all as specified and directed .
All as per item No 107 above but capacity 120 to 150 ltrs
S&F in repalcement of condenser copper tubing with aluminium fins suitable for 40 to 80 ltr capacity water cooler
All as per item No 109 above but capacity 120 to 150 ltrs
M& for rewiding and repairing of fan motor suitable for water cooler capacity 40 to 80 ltrs of any size with super enamelled copper conductor of existing gauge complete all as specified and directed
All as per item No 111 above but capacity 120 to 150 ltrs
M&L for cleaning of water tank of desert coolers and cleaning of side panels with steel wire brush scratching old paint from complete desert cooler externally and internally and painting of the same with synthetic enamel paint (ash/hammerton epint) one coat extrernally with spray painting and with a coat of wate resistance paitn inside over a suitable fprimer coat incl replacement of internal wiring of suitable size complete all as specified and directed
Taking down existing unserviceable fan motor assembly complete with blades monting frame leg with rubber bush from desert coolers and S&F motor assembly complete with blades, mounting frames legs with rubber bus for desert cooler of capacity 3000/4000/50000 cum hrs and testing complete all as specified and directed by Engineer-in-charge
M&L for replacement of unserviceable /burnt submersible pump for desert cooler suitable for operation on 230 volts AC supply of capacity 18 watt complete all as specified and directed by Engineer-in-charge
Taking out with nylon threads suitable for any make of desert cooler and S&F wood wool pads with nylon threads suitable for any make of desert cooler having minimum maximum capacity 3000 cum/hr to 5000 cum hrs incuding S&F iron with PVC insulated protective guards for holding the wood pads firmly complete all as specified and as directed (Set ot three)
S&F body in replacement of desert cooler 4000 cum/hrs capacity made out of galvanized iron sheets with bottom tank of 18 gauges, top cover of 20 gauge and side panels of 23 gauge GI sheet duly fitted with 1/3" thick woold wool pads including heavy duty 22 gauge frame grill burried with one piano type amps complete all as specified and directed
All as per item No 117 above but 3000 cum/hr capacity
S&F side panels for desert cooler of capacity 3000 cum/hr made with 22 gauge GI sheet complete all as specified
S&F side panels for desert cooler of capacity 4000 cum/hrs made with 22 gauge GI shet complete all as specified and directed
S&F side panels for desert cooler of capacity 5000 cum/hrs made with 22 gauge GI sheet complete all as specified
S&F in replacement of PVC water distribution system of desert coolers complete with PVC elbow, PVC pipe heavy duty 15mm dia all as directed
S&F in replacement of 15mm float valve PVC complete all as specified Make: Prayag/Polytuff
Taking out the existing desert cooler from ground/1st floor for repairs & fixing only of desert cooler at ground/1st floor after servicing/repair at required position as including painting complete of existing MS angle iron stand as per existing colour all as directed and complete all as specified and directed.
S&F 4mm thick commercial plywood as in existing window at any floor including cuting of plywood etc all as directed (for the purpose of payment the area of plywood cut out in front of gril shal also be taken into account ant this piece of plywood shall be remain with the contractor)
S&F in cemrent concrete incuding cutting and fabircating of angles iron 40mmx40mmx6mm thick ake to shape for fixing in wall in concrete over a coat of red oxide an angle iron frame complete all as specified and directed by Engr-in-charge
M&L rewinding of desert cooler fan motor/exhaust fan motor of any make and sweep and size including replacing of suitable bearing & bushes and greasing to make fully functional complete all as specified and directed
S&F in replacemtn electric cable PVC insulated rubber sheathed circular multistranded copper conductor of size 1.00 sqmm 3 core, Make: National /Havells/Kalinga/Plaza.
S&F GI tubing 15mm bore in ground/1st floor with its connected fittings such as the elbows, nipple and as directed by Engineer-in-charge
S&F in replacement of PVC stop cook 15mm. Make: Prayag/Polytuff
S&F in replacement of PVC connection 600mm long. Make: Prayag/Polytuff
S&F in replacement of PVC connection 900mm long make: Prayag/Polytuff
S&F in replacment of switch P/T 5 Amps, Make Anchor/Kinjal/Sanico
S&F in replacement of plug top 5 Amps, Make: Anchor/Kinjal/Sanico
All as per item No 136 but 15 Amps Make-Anchor/Jindal/Sanico
M&L for opening, dismantling, tracing the faults, repairing, servicing and reassembling the voltage stabilizer suitable for 230 volts 50 Hz, AC supply single phase of capacity 5 KVA complete all as specified and directed by Egnineer-in-charge
M&L for replacement of following items suitable for voltage stabilizer 5 KVA capacity suitable for working 30 volts, 50 HZ Ac supply. (i) Rewinding of transformer compelte with super enamelled copper winding wire of same gauge including varnishsing, draying, insulating compelte
Replacement of electromagnetic power relay A-50, 24 volts series SR
Replacement of voltmeter (0-300) volts for 5 KVA and Make as per existing
Replacement of PCB as per existing make.
Replacement of LCD display unit complete as per existing make
Replacment of input and output connection terminal plate
Supply and fixing fire hydrant landing valve type 'A' (single head outlet) gun metal of 80mm dia landing valve with 63mm dia female outlet complete and 80mm inlet with rubber blank cap and chain as per IS 5290-1983, suitable for brigade hose of 63mm with coupling conforming to IS 903 including taking down the existing one complete all as specified and directed by Engr-in-charge.
Supply and fixing of weather proof standard fire hose box made of 16SWG MS sheet 900mmX600mmX450mm with double door with 4mmthick glass and door frame including locking arrangement by allen key stove enamelled fire red finish with "fire hose" marked on front and brilliant white inside yard, suitable for housing of and consisting of 2 length RRL, hose pipe conforming to IS 6361979 (type-II) of 63mm dia GM instantaneous male and female (IS:903) and branch pipe and nozel 12.5mm dia (for external hydrant) including taking down the existing one complete all as specified and directed by Engr-in-charge.
Supply and fix of gun metal single headed ISI marked oblique pattern hydrant valve with 80mm dia flanged inlet and 63mm dia female outlet branch pipe and nozzle conforming IS 903 including gun metal capand GI chain realese type plug and all accessories as per IS 5290 including taking down the existing one complete all as specified and directed by Engr-in-charge.
Supply ,installing, testing and commissioning of hose box for hose reel of size 1200mmX2100X600mm made of 16 SWG MS sheet angle frame capable of accomodating of the following (for internal ) (i) 01 No 63mm dia oblique pattern instataneous female type GM landing valve with caps and chain conforming to IS 5290 with 100mm dia pressure guage complete including taking down the existing one all as specified and directed by Engr-in-charge. (ii) 2X15 mtr long 20mm dia reinforced rubber hose reel with MS, painted , swing type reel drum 6.5mm nozzle etc conforming to 884 incl supporting bracket. (iii) One set of GM branch pipe conforming to IS 903 (iv) One branch pipe, one fire man axe, first aid hose reel and fire extinguisher
Supply, fixing, testing and commissioning of wall mounting swinging type first aid fire hose reel with drum, hanging bracket 30mtr long and 20mm dia high pressure hosereel as per IS 444 with gun metal shutt off nozzle having 5mm dia orifice. The hose reel shall be conforming to IS 884-1985. Rate shall including for 25mm dia MS pipe connection from riser to hose reel sockets, nipples, elbows and ball valve (25mm dia), Drum shall be fixed on adjoining wall through anchor fastener/cement concrete hook or MS stand as per site requirement and the rate for fixing/hanging items inthe rate quoted( for internal hydrant and one each an either side of stage) including taking down the existing one complete all as specified and directed by Engr -in-charge.
S&F 63mm dia15mtr long controlled perculating rubberised fabric hose conforming to IS 8423 (type A) incl gun metal male and female instantaneous coupling bound and rivetted to hose pipe with 1.5mm dia copper wire complete in all respect, hose BSI marked, conforming to IS 636 type II and complete male female coupling conforming to IS 903 including taking down the existing one complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement of fire hydrant stand post 1.5mtr height single head outlet gunmetal of 80mm dia with 63mm dia female outlet complete and 80mm inlet rubber blank cap and chain as per IS 5280-1983 suitable for brigade hose of 63mm with coupling conforming to IS 903 for external hydrant complete all as specified and directed by Engr-in-charge.
Supply, fixing , testing and commissioning of GM four way, fire brigade inlet to hydrant ring with 63mm dia instantaneous type inlet and 150mm dia flanged outlet conforming to IS 904 with blank cap and chain including taking down the existing one complete all as specified and directed by Engr-in-charge.
Supply ,fixing ,testing and commissioning of 200mm pipe heavy duty class 'c' MS pipe 6mm thick ISI marked as per IS:1239 with all necessary fittings & fabrication like tees, elbow, flanges, reducer, gaskets, nut and bolts etc welding or screwed joint as required including fixing of pipe with necessary standard standard clamps structural steel supprt (chilly make) as required/directed at site including painting of two coats of synthetic enamel paint of post office red color over two coats of red oxide primer including taking down the existing one complete all as specified and directed by Engr-in-charge.
All as per item no.153 above but size of 100mm
All as per item no.153 above but size of 80mm
Supplied and installed in replacement of valve reflux with by pass arrangement complete all as specified and directed by engr-in-charge.
S&F 80mm dia flanged end basket with foot valve conforming to IS 4038 strainer fabricated from 16 guage brass sheet with 3mm slot made from MS body bottom and top removable flange with nuts, bolts, etc complete including joints and joining materials as per site requirement complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement of rubber mat of size 1 mtrx2 Mtrx19mm chequre type black complete all as specified and directed by Engr-in-charge.
Supply and installing in replacement of fire extinguisher mechanical foam 09 ltrs capacity conforming to IS 15683 and all as specified and directed by Engr-in-charge.
Supply and installation in replacement of fire extinguisher dry chemical powder (ABC type ) 6 kg capacity conforming to IS 15683 and all as specified and directed by Engr-in-charge.
Supply and installation in replacement of fire extinguisher light weight squeez grip type CO2 of 4.5 KG conforming to IS 15683 and all as specified and directed by Engr-in-charge.
Supply , fixing in replacement of butterfly valve of size 150 mm dia conforming to IS 13095 , flanged ends drilled type with steel spindle including nuts bolts washers and jointing material complete all as specified and directed by Engr-in-charge.
Supply , fixing in replacement of butterfly valve of size 100 mm dia conforming to IS 13095 , flanged ends drilled type with steel spindle including nuts bolts washers and jointing material complete all as specified and directed by Engr-in-charge.
Supply , fixing in replacement of non return butterfly valve of size 150 mm dia ISI marked all as specified and directed by Engr-in-charge.
Supply , fixing in replacement of non return butterfly valve of size 80 mm dia ISI marked all as specified and directed by Engr-in-charge.
Supply , fixing in replacement of 100mm dia burden type stainless steel dial type pressure gauge having calibration of 0-15 kg/cm2 including brass isolation valve and pipe all as specified and directed by Engr-in-charge.
Servicing of induction motor 75 HP coupled with fire pump complete including oiling burnt winding replacement , greasing replacement of wornout rubber packing wornout nuts and washers etc including testing to the entire satisfaction of Engineer in charge.
Servicing of induction motor 25 HP coupled with fire pump complete including oiling burnt winding replacement , greasing replacement of wornout rubber packing wornout nuts and washers etc including testing to the entire satisfaction of Engineer in charge.
Servicing of induction motor 15 HP coupled with fire pump complete including oiling burnt winding replacement , greasing replacement of wornout rubber packing wornout nuts and washers etc including testing to the entire satisfaction of Engineer in charge.
M/L for Maintenance and servicing of standby DG Set complete including draining out of diesel from tank , cleaning the tank thoroughly and refilling the drained out diesel, draining out engine oil from the sump, cleaning the sump thoroughly and refilling the sump with new engine oil to it’s required level, replacing the fuel filter, lubricating oil filter , Check & clean air cleaner , change air cleaner elements, Check coolant level & make up the same ,Drain the Fuel filter & water separator ,filling the starting batteries with electrolyte/Distilled water to maintain the required specific gravity, replace the u/s brass Connectors for batteries , Cleaning of Battery terminals & applying petroleum jelly to battery terminal posts & brass connectors , changing of V-belts, changing hoses and clips of air cleaner, checking of exhaust leakage, governor, breathers etc, adjust/set the same for proper functioning of DG Set, Checking of fuel, oil and water/ coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories as prescribed by the manufacturer and test for Satisfactory running of DG set for two hour at connected load & record shall be made in respect of RPM , oil pressure, oil temp. , Coolant temp. Voltage, frequency , load current ,Battery charging , fuel consumption etc. as directed by the Engr in charge for 125 KVA DG Set Make – Kirloskar installed at , Tech pump house. Note :- 1. Engine oil for refilling will be measured and paid Separately. 2. Coolant for make up will be measured & paid separately 3. DHPP will be issued by dept for testing only.
All as per item No. 170 here in before but for 70 kVA DG Set installed at Old and new domestic pump house Camp area
All as per item No. 170 here in before but for 50 kVA DG Set installed at CPRU pump house
All as per item No. 170 here in before but for 40 kVA Make - Cumins at STP pinto park.
All as per item No. 170 here in before but for 35 kVA installed at MT astha pump house and Map pump house camp area.
All as per item No. 170 here in before but for 15 kVA DG Set installed at 1AFSR and Maude line borewell
All as per item No. 170 here in before but for 200 kVA DG Set Make - Kirloskar installed at CPRU and UGBO .
Supply and fill lubricating oil for DG Sets as per manufacturer's recommendation Make - IOC, Castrol, Hindustan Petroleum.
Supply and fill coolant for Radiator as per manufacturer's recommendations.
Overhauling of radiator assembly by removing from engine transporting to the workshop and removing the sediments and scales, corrosion etc by means of acid cleaning and high pressure water washing and air cleaning, gas welding / soldering with good quality materiaL for stopping the leakage etc, re-assembling the same with new gaskets and transporting to the site, fixing to the engine with new hoses, clips complete as required for DG Set 125 KVA
All as per item No. 179 here in before but for 70 kVA
All as per item No. 179 here in before but for 50 kVA
All as per item No. 179 here in before but for 40 kVA
All as per item No. 179 here in before but for 179 kVA
All as per item No. 179 here in before but for DG Set 15 KVA
All as per item No. 179 here in before but for DG Set 200 KVA
Taking down Unserviceable RPM Meter & Supply & fix New RPM Meter on DG Set complete all as specified and directed by Engr-in-charge.
Supply & Fix PVC insulated with standard copper conductor cable 2 mtrs length each soldered with 2 Nos gun metal battery terminals suitable for 180 AH 240 volts DC battery.
Supply only distilled water in one litre container
Supply only sulphuric acid for lead acid battary in one litre container.
M&L for servicing of self starter assembly of DG Set 24 volts by disconnecing the self starter from the engine and transport to workshop for carryout overhauling by replacing all unserviceable spare parts including pinion, coabon brushes , bushes, contacts, copper plates, jumping leads ets and replacing the filled coil and varnishing all as directed.
Draining out existing radiator, water cleaning thoroughly the radiator fins by air blower recharging the chemically treated coolant including replacement of all water hose pipe suitable for 15 kVA to 125 Kva DG Sets.
Dismantling the existing radiator ' V' ' belt suitable for 125 KVA DG setand supply and fix new belt complete all as specified and directed by Engr-in-charge.
V ' Belt suitable for 70 KVA DG set
V ' Belt suitable for 50 KVA DG set
V ' Belt suitable for 40 KVA DG set
V ' Belt suitable for 35 KVA DG set
V ' Belt suitable for 15 KVA DG set
V ' Belt suitable for 200 KVA DG set
Dismantling the self starter 24 Volts DC of DG set and transporting to workshop for carrying out overhauling by replacing all unserviceable spares including pinion, reassembling and refixing the same to DG set and testing to the entire satisfaction of Engr-in-charge.
Preparation of old painted surface of fuel tank by scrapping / removing old paint , dirt etc, and painting with two coats of blue synthetic enamel paint over a coat primer including calibration of capacity of tank and marking the level of capacity all as specified and directed by Engineer-in-charge suitable for : a) Fuel tank in respect of 125KVA DG set capacityk -01 No. b) Fuel tank in respect of 70KVA DG set capacityk -02 No. c) Fuel tank in respect of 50KVA DG set capacityk -01No. d) Fuel tank in respect of 40KVA DG set capacityk -02 No. e) Fuel tank in respect of 35KVA DG set capacityk -02 No. f) Fuel tank in respect of 15KVA DG set capacityk -01 No. g) Fuel tank in respect of 200KVA DG set capacityk -02 No.
Dismantling existing fuel injection pump of DG set , transporting to work shop and overhauling complete including calibrating and re-fixing the same and testing the DG Set to the entire satisfaction of Engineer-in-charge of at CPRU and UGBO -200 KVA
Tech pump house-125 KVA
Old domestic pump house-70 KVA
New domestic pump house-70 KVA
Map pump house -50 KVA
CPRU pump house -50 KVA
STP pinto park -40 KVA
MT astha pump house -35 KVA
Map pump house camp areae -35 KVA
1 AFSR BOREWELL -15 KVA
Maude line borewell- 15 KVA
Dismantling rubber coupling of DG set and supply and fix rubber coupling for following DG sets including testing and commissioning complete :- a) CPRU and UGBO -200 KVA b) Tech pump house-125 KVA c) Old domestic pump house-70 KVA d) New domestic pump house-70 KVA e) CPRU pump house -50 KVA f) STP pinto park -40 KVA g) MT astha pump house -35 KVA h) Map pump house camp areae -35 KVA i) 1 AFSR BOREWELL -15 KVA j) Maude line borewell- 15 KVA
Dismantling old flexible fuel hose pipe from DG set , supply and fix new hose pipe suitable for CPRU and UGBO -200 KVA
Tech pump house-125 KVA
Old domestic pump house-70 KVA
New domestic pump house-70 KVA
CPRU pump house -50 KVA
STP pinto park -40 KVA
MT astha pump house -35 KVA
Map pump house camp areae -35 KVA
1 AFSR BOREWELL -15 KVA
Maude line borewell- 15 KVA
Dismantling water temperature gauge of DG set , supply and fix the same and testing complete.
Dismantling Oil Pressure gauge of DG set , supply and fix the same and testing complete.
Supply and fix self starter of capacity 24 volts DC suitable for New domestic pump house-70 KVA
UGBO-200 KVA
Disconnecting Existing defective voltage stabilizer at different location of 15 KVA capacity 3 phase 415 volts from electric mains Isolating the naked connections , removing from foundations by unscrewing the nuts bolts etc carrying to the factory /workshop for repair by draining out the transformer oil through the drain plug , dismantling both nut and bolt and lifting the top portion to carry out through inspection and clean the bottom portion of the voltage stabiliser tank by removing the mud and slurry and deposited material for prevention of short circuit and Refixing in Original position after Repair and testing complete all as specified and as directed by Engineer -in - charge .(replacement of defective parts shall be measured and paid separately )
Disconnecting Existing defective voltage stabilizer at of 50 KVA capacity 3 phase 415 volts from electric mains Isolating the naked connections , removing from foundations by unscrewing the nuts bolts etc carrying to the factory /workshop for repair by draining out the transformer oil through the drain plug , dismantling both nut and bolt and lifting the top portion to carry out through inspection and clean the bottom portion of the voltage stabiliser tank by removing the mud and slurry and deposited material for prevention of short circuit and Refixing in Original position after Repair and testing complete all as specified and as directed by Engineer -in - charge .(replacement of defective parts shall be measured and paid separately )
S&F in replacement of Electronic circuit card (PCB) . Suitable for Existing Make - Volina
S&F in replacement of PCB Holder .Suitable for Existing Make - Volina
S&F in replacement of rotary switch 5 Amps for RYB Phase .
S&F in replacement of Micro processor based control card for Each phase ( Set of Three ).Suitable for Existing Make - Volina
S&F in replacement of Dimmer state unit 10 Amps suitable for Existing Make - Volina
S&F in replacement of Dimmer state unit 60 Amps suitable for Existing Make - Volina
S&F in replacement of Digital Amp Meter with CTs suitable for Existing Make - Volina
S&F in replacement of voltmeter 0-500 Volts digital type suitable for Existing Make - Volina
S&F in replacement of Panel lamp as per Existing ( set of three ).
S&F in replacement of MCCB 3 pole 415 volts 125 Amps of breaking capacity 35 KA frame LS Make : Havells or Equivqllent
Supply and filling Transformer Oil for top up as required suitable for voltage stabilizer all as specified and directed . Make : Power oil
M&L for Preparation of old painted surface of Servo Voltage stabiliser by scrapping / removing old paint , dirt etc, and spray painting with two coats of blue synthetic enamel paint over a coat of primer including writing of MES / SM No of capacity 15 KVA all as specified and directed by Engineer-in-charge .
M&L for earthing complete with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to GI strip 32x6mm as earth lead by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge mesh, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of GI strip protected by 40 mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, and including all excavation and earth work & connecting the earthing to an earthing test point complete all as specified & directed by Engr-in-Charge.
J.P. Enterprises
Flint India
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .