Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.3 LAccepted-AOC | L1 | Accepted-AOC AOC PLACED ON L1 BIDDER WITH CONTRACT AGREEMENT NO GE/SHL/36 OF 2023-2024 | |
| 2 | L2₹47.0 L+₹1.0 L (2.19%)Rejected-Finance | L2 | Rejected-Finance REJECTED BEING L2 BIDDER |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
11 Sept 2023, 6:00 pmClosed
GE SHILLONG
GE SHILLONG SHILLONG DIVISION PIN 793002
PROVN OF ADDN EXHAUST FAN 250MM FOR TOILET 148 NOS AT CERTAIN ACCN IN PINE WALK AREA AND PROVN OF ELECTRIC CONNECTION TO GENR SHED AT HQ RTG ZONE SHILLONG AND PROVN OF 01 X LIGHTING PROTECTION OF COMM COMPLEX OF HQ 101 AREA AT FCSR SHILLONG AND PROVN
2022_MES_567373_6
GE/SHL/ TOKEN-77 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE SHILLONG
ALL AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
Yes
GE SHILLONG
₹84,000
Yes
21 Sept 2023
14 Aug 2023
12 Sept 2023
15 Aug 2023
11 Sept 2023
21 Aug 2023
Amount
Supply and fixing LED flood light 200 Watt , pressure die cast aluminum housing, heat resistant glass, IP65 protection, better optics for uniform distribtion complete with all accessories internally pre wired and including connecting up with three core 1.5 sqmm flexible copper conductor cable from ceiling rose to connector of light complete all as per specified and directed .Make- Philips/CG/Havells
M & L for Steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55 (11m long) conforming to IS-2713 (Part-I & II) including painting of pole with two coats of aluminium paint over a coat of red oxide zinc chrome primer from top of the pole to 1.5m above the bottom of the pole and painting with two coats of black bituminous paint over a coat of red oxide zinc chrome primer upto 1.5m from bottom of the pole including numbering of poles with suitable size bracket and clamps for fixing LED street light / Flood light fittings etc as directed complete all as specified and directed.(Note: Excavation and earth work and PCC shall be measured and paid separately under respective items)
Supply and fix MCB Distribution board , 240 volts single pole and neutral ,double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 8 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection, including taking down complete all as specified and directed. Make: Havells Cat part No DHDPSHODRW12 or equivalent in Schnieder/GE/C&S.
Supply and fix MCB DP, 240 Volts, 40 Amps, 10 kA rupturing capacity 'C' series complete all as specified and directed including taking down old one.
Supply and fix in repairs MCB, single pole 240 volts 6 to 32 Amps capacity fixed in DB's including taking down old one complete all as per specified and directed.
Supply,laying, and testing XLPE cable insulated,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with starnded aluminium conductor of size16 sqmm 2 core complete all as specfied and directed.
Excavation in trenches n exc 1.5 mtr wide and depth n exc 1.5 mtr deep for foundation, laying GI pipes and UG cables etc n exc 10 sqmtr on plan, in hard/dense soil and getting out complete all as specified and directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
M & L for providing dry river sand as in sand cushioning to UG cable including punning gently complete all as specified and directed.
Removing excavated material not exc 50 mtr and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
M & L Sub class'B' old size well burnt brick laid flat in trenches as protection to LT cable complete all as specified and as directed.
Supply and fixing GI Tubing light grade under road, on pole floor and on wall for cable protection complete all as directed for following sizes 40 MM dia bore
Supply and fixing LED flood light 50 Watt , Green/Multi colour light pressure die cast aluminum housing, heat resistant glass, IP65 protection, better optics for uniform distribtion complete with all accessories internally pre wired and including connecting up with three core 1.5 sqmm flexible copper conductor cable from ceiling rose to connector of light complete all as per specified and directed.Make- Philips/CG/Havells
S & F Philips 11.5 Watts Smart Lightstrip Plus with suitable size LED driver warm white and fixed in ceiling / wall with 2 Nos PVC block suitable size complete all as specified and as directed including taking down old unserviceable light fittings Make- Philips Cat part No- 915005240701
Supply and fixing LED Street light 60 Watt, warm white type , pressure die cast aluminum housing, heat resistant glass, IP66 protection, better optics for uniform distribtion complete with all accessories internally pre wired and including connecting up with three core 1.5 sqmm flexible copper conductor cable from ceiling rose to connector of light , including service bracket complete.Make Make:- Bajaj /CG Surya / havells .
Supply and fixing Flexiable cable 6 Sqmm Weather proof single flat twin core cable including pvc pipe 20 mm complete all as specified and directed
Supply, lay in trenches, floors ,fix on wall/pole, passing through pipes etc.,LT UG cable , 1100 volts grade, PVC/ XLPE insulated , with multistranded aluminium conductors, armoured with galvanised steel wire or tape ,gland, lugs etc , of size 70 Sq.mm 3.5 core , confirming to IS specifications complete all as per specified and directed
M & L for cutting exisitng bitumenous road surfaces not more than 150 mm thick, removing for laying of pipes/cables, making good with PCC 1:3:6 type C1 20 mm graded aggregate to match with the adjustant surface. Note Excavation and earth work below 150 mm thick will be measured and paid under relevent items complete all as per specified and directed.
Supply and fix 50 mm dia GI pipe light grade on pole / wall or lay in trenches under road / drain crossings etc., for drawing cables, ISI marked , including necessery pipe fittings ,clamps, bolts , nuts etc complete all as per specified and directed.
Supply, lay in trenches, floors ,fix on wall/pole, passing through pipes etc.,LT UG cable , 1100 volts grade, PVC/ XLPE insulated , with multistranded aluminium conductors, armoured with galvanised steel wire or tape ,gland, lugs etc , of size 25 Sq.mm 3.5 core , confirming to IS specifications complete all as per specified and directed
Supply and fix in repairs MCB DB 4 way vertical sheet metal enclosure TPN 415 volts, 50 Hz, with IP-43 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete all as specified. L&T/Seimens /Legrand . (Note : MCB SP/TPN shall be measured and paid seperately under appropriate items of this schedule . Note : Copper thimble shall be used for connection of cable .
M & L Sub main wiring with two run single core 6 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including Cassing capping , medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 6 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion inculding taking down old wiring etc complete all as directed.Note: (i) Two runs of 4 sqmm and one run of 4 sqmm cable and one run of PVC conduit shall be measured as one RM.
Supply and fix MCCB TPN, 240 Volts, 100 Amps, 25 kA rupturing capacity 415 Volts with sheet metal inclosure type complete all as specified and directed including taking down old one.
Supply and fix MCCB TPN, 240 Volts, 100 Amps, 10 kA rupturing capacity415 Volts complete all as specified and directed including taking down old one.
M & L Sub main wiring with two run single core 4 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including Cassing capping , medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 4 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion inculding taking down old wiring etc complete all as directed.Note: (i) Two runs of 4 sqmm and one run of 4 sqmm cable and one run of PVC conduit shall be measured as one RM.
Supply, install , testing and commissioning of outdoor LT distribution feeder pillar IP-65 , CPRI approved of suitable size factory made totally enclosed dust and vermin proof , double leaf shutter in front and single leaf shutter in rear made out of 3.15 mm thick CRCA sheet duly fabricated and having proper front and rear locking arrangement duly painted with powder coated paint and aluminium bus bar 200 amps, 415 volts, 50 Hz 3 phase and 4 wire system with the following items connected as under including supplying and fixing on MS chanel 75mmx40mmx5mm in PCC foundation and PCC work around the panel board witnin two fit area:- INCOMING Changeover switch 200 Amps 4 pole-01 (a) MCCB 4 pole 200 Amps, 415 V, 36 KA-01 No (b) LCD multifunctioning meter-01 No (c) Phase indicator Lamps (RYB phases)-01 Set (Set of Three) LED Cluster type (d) CTs 100/5 amps-set of three (e) Aluminium bus bar 300 Amps-03 Nos and 150 Amsp -01 Nos () Internal Wiring for panel incl insulators, sleeves etc OUTGOING (a) MCCB 4 pole 160 Amps, 415 V, 25 KA-02 No (b) MCCB 4 Pole 100 Amps, 415 V, 25 KA-01 No (b) MCCB 4 Pole 63 Amps, 415 V, 25 KA-01 No
Material and labour for earthing complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm buried directly in ground vertically to a depth notless than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth strip 32 x 3mm dia by means of bolts, check nuts and washers ,galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cmX 5 cm with 10mm dia TMT bars 8 cm C/c both ways and one handle for lifting made out of 8 mm dia TMT bar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Electrical Plate No 3 of SSR part -I complete all as per specified and directed
Supply and fixing, installtion and testing of ESE Air Terminal: Supply from Global leader Duval Messien of France SATELIT 3- 45 Air terminal with external, wide area, early streamer emission (ESE) type lightning arrestor made of robust 304L stainless steel (INCLUDES TELETESTER). It is a proactive, intelligent and remotely monitored electronic device, powered by long life battery on board, which should be rechargeable with solar cells. It is capable of polarizing the tip with a voltage between 20 kV and 30 kV, synchronized with an approaching lightning and triggering a powerful upward streamer into the air, 60 microseconds earlier than naturally formed streamers. The lightning arrestor is capablen of grounding repeat lightning strikes and both negative and positive strikes that may occur within few milliseconds of each other. Operating Principle:- 1. This lightning arrester is equipped with a double device of polarization. The first “active” collects and stores the solar energy in the batteries, then charges maintain the ascending tracer propagation. An integrated sensor of current allows to measure the during a descending tracer approach in the zone of protection area. When it exceeds 1A, The sensor triggers the capacitors discharge and releases the necessary energy to the ascending tracer propagation, polarizing the point at a voltage between 20 and 30 kV.
2 support mast of robust design, made with 6 Mtr 40mm dia. class B medium MS pipe duly galvanized with minimum 85 micron zinc coating, along with all accessorires like clamps, saddles, holding arrangements, guy wire etc. to fix the mast to the shed/structure at hightest point such that the Air terminal is 5 metres above the tallest structure is installed as per site requirement.- 01Nos NOTE: Any type of Civil work is not in SGI's scope of work. 3. Down Conductor :of 70sqmm. Multistrand Single Core Unarmoured Cu. Cable along with accesseries upto EARTH PIT.50 MtrNOTE : Down Conductor length may vary depending upon site condition and the same shall be supplied at extra cost.- 01Nos 4. The second system called “passive” stores the electrostatic energy present in the atmosphere at a stormy cloud approach. The integrated sensor in the “SATELIT-3 “measures the value of theambient electric field and releases the impulsion device as for theactive part of the lightning rod. The one cause a quasi instantaneous inversion of the head polarity of the lightning rod causing a sudden amplification of the electrical field on its point. The lightning arrestor has in built self check mechanism to facilitate remote testing from a distance of 100 meters. NOTE: The Early Streamer Emission lightning conductor SATELIT
5 can be tested remotely, via radio signals, with the new TeleTester-S3.The Satelit 3 has an on-board transmitter using a standard frequency and transmitting a signal every 90seconds to confirm the correct operation of the lightning conductor's electronics, including then polarization of its tip. The TELETESTER receives the information transmitted by the SATELIT 3 and emits and audible signal confirming the installation is fully functional. This check can be performed up to a distance of 100M between the SATELIT 3 and the Telemeter. Generation III Air Terminal:- SATELIT 3-45: Level 1 Protection upto a Radius of 63 Meters. Level 3 protection upto a Radius of 81 Meters. 6. Steel Test Joint- 01 Nos 7. low impedance high voltage conductor, made from high conductivity GIstrip 25mm x 6mm for pit to pit interconnection.- 10 Mtr 8. Earthing Electrodeof 17.2 mm dia. copper molecularly bonded on steel electrode each 2.4m long.- 03 Nos 9. U- Clamp Bolt. (Copper with Gunmetal)- 03Nos 10. Earth Enhancing Chemical Compound: earth enhancing soil treatment chemical compound n"EARTHCON" (IEEE 80:2000 Clause 14.5b) having essential chemical ingredients, such as ionic chemicals, dispersion chemicals, expansion chemicals & hygroscopic chemicals, to provide stable low resistance for earth terminal to make it maintenance free. (12.5kg/bag)- 6 Bags. 11 Earth Enhancing Chemical Compound: of earth enhancing soil treatment chemical compound "TERRANITE" ( TESTED AS PER IEC62561-7) having essential chemical ingredients, such as ionic chemicals, dispersion chemicals, expansion chemicals & hygroscopic chemicals, to provide stable low resistance for earth terminal to make it maintenance free. (25kg/bag)- 03 Begs 11 Earth-pit cover: of HDPE medium duty Earth pit cover to withstand a maximum of 5 Ton load.- 03 Nos 12 Lightning Flash Counter: of COSMOS Lightning Flash Counter, electromechanical type, in an IP 65 enclosure, capable of registering lightning strikes of 1 kA to 100 kA (8/20 micro second waveform). The counter is to be installed on the down conductor at man height for easy readability of Lightning Strike count.- 01 Nos
Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, in PVC Casing capping on wall/ceiling and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box/metal flush box with suitable steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new 3 mm thick plastic laminated sheet top cover for housing the switches , socket outlets, fan regulators etc. with brass screws and brass washers and making good the disturbed surfaces as per existing for one light point controlled by one switch. Note :- Switch, socket and fan regulators to be measured and paid for separately .
Supply and fix switch piano (ISI marked) Single pole 240 volts, 5Amps complete all as per specified and directed
Description all as per serial item No 31 above but with 4 sqmm cable for 3 pin 15 Amps switch socket outlet (Power point) complete all as per specified and directed
Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal complete all as per specified and directed
S & F Exhaust fan 230 volts , 250mm, steel body heavy duty including making all electric connection complete all as specified and as directed including cutting of hole on wall and makng good disturbed surface of wall and outer wooden box for fan fix on wall Make Bajaj/Havell's/CG.
M & L for aluminum housing ventilator for bathroom window with making hole on window with aluminum partition with housing accessories and making good disturbed surface of wall for fan fix on wall complete all as specified and directed.
Material and labour for Point wiring with 4 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall/ceiling and incuding provision of 4 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box/metal flush box with suitable modular or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new 3 mm thick plastic laminated sheet top cover for housing the switches , socket outlets, fan regulators etc. with brass screws and brass washers and making good the disturbed surfaces as per existing for one light point controlled by one switch. Note :- Switch, socket and fan regulators to be measured and paid for separately . PVC Conduit confirming to IS 9537 part I & III Note (All chases will be cut by chase cutter only) AMke of Cable - KEI/ Havells / Kalinga
M&L for providing cover/shed to pumps, DB's as in framed work of angles other sections with sheeting including dirilling for fixing of sheets, MS door fitting , hinges etc complete all as specified and as directed by Engr -in-Charge.
M & L Sub main wiring with two run single core 6 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia concealed on wall/ceiling in PVC conduit, medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall along with one run of 6 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion including taking down old wiring etc complete all as directed. Note: (i) Two runs of 4 sqmm and one run of 6 sqmm cable and one run of PVC conduit shall be measured as one RM. (ii) Cutting of chases in the wall of appropriate size shall be carried out with electric cutter machine . (iii) Necessary plastering in the disturbed surface of wall and distempering /white washing to match the existing colour shall be included in the unit rate quoted.
Supply and fix in repairs MCCB DB 4 way vertical sheet metal enclosure TPN 415 volts, 50 Hz, with IP-43 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete all as specified. . (Note : MCB SP/TPN shall be measured and paid seperately under appropriate items of this schedule . Note : Copper thimble shall be used for connection of cable .
Supply and fix MCCB TPN, 240 Volts, 100 Amps, 10 kA rupturing capacity415 Volts complete all as specified and directed including taking down old one.
Supply and fixing of hot water Geysers of 25 ltrs capacity 5 star rated vertical type includng fixing of bolts , nuts grouted into the wall , and necessary cement work , making good of disturbed surface of wall , giving electric , hot and cold water pipe, tab etc and water connection and testing after installation complete all as per specified and directed. Make : CG/LG/Ronald.
Supply and fix Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps with compele all as specifed and directed by Engr-in-Charge.
Supply & laying galvanized steel tubing, medium grade laid in trenches/floor/wall and joined including necessary fittings such as bends, elbow, tees, sockets, etc for 15mm dia pipe complete all as per specified and directed.
S&F bib taps, chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule all as specified and directed.
S&F angle stop valve cast copper alloy, chromium plated screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixing of size 15mm complete all as per specified and directed.
Material and labour for earthing complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm buried directly in ground vertically to a depth notless than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, check nuts and washers ,galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cmX 5 cm with 10mm dia TMT bars 8 cm C/c both ways and one handle for lifting made out of 8 mm dia TMT bar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Electrical Plate No 3 of SSR part -I.
Supply, Install, Testing and commissioning of Solar Hot Water System (Flat Plate Collector) based on indirect transfer of heat of capacity 300 LPD with electrical heating backup of 4 KW and Make up water tank 500 ltr etc Complete all as specified and directed.
Supply and fix rotational moulded polythylene water storage tanks (cylindrical vertical with closed top) capacity 500 ltrs hoisted and fixedin position all as specified in SSR part-I complete all as specified and directed.
S & F Cross arms, bracings , supports, Clamps, MS plain black sheets and back plate fabricated from structural steel sections incluidind nuts, bolts, washers, welding , bending cold or hot , drilling holes for bolts in any shapes or sizes as indicated or Directed and inclusive of one primer coat, one under coat and one finishing coat of paint all as specified and directed by Engr-in -Charge.
M & L PCC 1:2:4 type B2 (using 40 mm graded stone aggregate ) as in foundation , Mass concreateetc complete all as directed by Engr-in -Charge.
S & F Hot water pipe duly insulated with glass wool and aluminium cladding 15 mm bore testing complete all as specified and directed.
S & F Hot water pipe duly insulated with glass wool and aluminium cladding 20 mm bore testing complete all as specified and directed.
S&F bib taps, chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as per specified and directed.
S&F 20 mm gate valve with fancy type chromium plated, cast copper alloy , screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe testing complete all as specified and directed. .
S&F 15mm gate valve with fancy type chromium plated, cast copper alloy , screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe testing complete all as specified and directed. .
S&F Brass CP mixer for mixing hot and cold water 15mm dia screwed down for iron pipe complete all as per specified and directed.
Supply and fix Switch socket combination 5/16 amp 5 in 1 universal complete all as specified and directed.
Material and labour for Sheet metal Enclosure DB for MCB SP&N Single Door 4 way with 200 Amps rated busbar complete all as per specified and directed.
Supply and fix MCB SPN, 240 Volts, 6 to 32 Amps, 10 kA rupturing capacity, 'C' series complete all as specified and directed including taking down old unserviceable one. Make: Havells
Supply and fix switch socket combination (ISI marked) 2/3 pin and 5/15 Amps, flush type, 240 volts complete all as specified and directed. Make- Havells/anchor/ Legrand.
M & L, installation and testing commissioning for Mini Force Single Phase pressure Booster Pump 0.5 HP 0.37 KW Pipe size 25X 25 mm , Head 6-24 mtr, head range 20-79 fit , Discharge Range 33-7 LPM, 220 to 240 Volts, 50 HZ with automatic operation, Noiseless operation, Brass Strainer, Less power Consumption, Dry run protection type and constant pressure application suitable size gate valve and accessories as per required smooth function of booster pump complete all as specified and as directed Make- CG model MINI Force II
M & L, installation and testing commissioning for Mini Force Single Phase pressure Booster Pump 1 HP 0.75 KW Pipe size 25X 25 mm , Head 7-45 mtr, head range 23-148 fit , Discharge Range 70-15 LPM, 220 to 240 Volts, 50 HZ with automatic operation, Noiseless operation, Brass Strainer, Less power Consumption, Dry run protection type and constant pressure application and suitable size gate valve and accessories as per required smooth function of booster pump complete all as specified and as directed. Make- CG model CFMSMB501.00-V24
M/S SAMAL CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .