Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.7 LAccepted-AOC III 6 7 2ND FLOOR ABOVE BANK OF BARODA GOPINATH BAZAR DELHI CANTT 110 010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | 1 | Accepted-AOC LOWEST BID | |
| 2 | 2₹7.9 L+₹21,400 (2.78%)Rejected-Finance 1 128 A SECOND FLOOR MOHAMMADPUR NEAR BHIKAJCAMA PLACE NEW DELHI 110066 | NEW DELHI | NEW DELHI | DELHI | 110066 | 2 | Rejected-Finance Other than Lowest |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
4 Feb 2020, 6:00 pmClosed
CWE New Delhi
HQ CWE New Delhi, Rao Tula Ram Marg, Delhi Cantt-10
Comprehensive, preventive, periodical maint of lifts at A Block and OT wing at Army Hospital (RR) under GE E/M RR Hospital, Delhi Cantt-10
2019_MES_307217_1
CWE-ND/62/2019-20
Open Tender
Miscellaneous Works
Item Rate
335 days
Delhi Cantt
Please refer tender documents
9 documents required · 9 mandatory
₹500
GE E/M RR Hospital
₹16,000
Yes
27 Feb 2020
7 Jan 2020
5 Feb 2020
7 Jan 2020
4 Feb 2020
21 Jan 2020
Amount
Electric Hospital passenger cum stretcher elevator /lifts of capacity 26 passenger serving (G+4) 5 floors -02 Nos lifts
Electric Hospital passenger cum stretcher elevator /lifts of capacity 26 passenger serving (G+5) 6 floors -02 Nos lifts
Notes : - (a) The entire work mentioned in this BOQ/Sch - ' comprehensive, preventive and periodical maintenance of lifts / elevators shall be got executed through OEM i.e. M/S Thyssen Krupp Elevator (India) Pvt Ltd only. The contractor shall upload / submit the scanned copy of MOU for AMC (inclusive of material) with lifts manufacturer, as mentioned above, In cover No. 1 along with his application & other documents. The contractor shall also have to submit hard copy of MoU with his application before last date of Bid Submission, failing which the tender application / bid will be summarily rejected and cover No. 2 of the Bid shall not be opened. (b) The lifts will be handed over to contractor in as and when condition and no claim in this effect will be accepted at any stage. (c ) The cost of all kind of replaced of defective parts / spares / control cards / oil / lubricants etc., other than mentioned in item 2.00 to 5.00 of this BOQ/Schedule A, as and when required to making the lift/elevator fully functional, is deemed to be included in quoted rates and no extra cost shall be paid to the contractor in this effect. Hence, the bidder is advised to visit the site to assess the quantum of work to be carried out in this contract and quote their rates accordingly. (d) The comprehensive / preventive / periodical maintenance includes weekly, fortnightly, monthly, quarterly, half yearly inspection/testing as per service manual or as per IS standard. The inspection / test report will be submitted to Engineer-in-charge. (e) The complete records of replaced spare parts, other than mentioned in BOQ/Schedule A, will be maintained and will be produced to Engineer-in-charge on monthly basis or as and when asked to produce the same.
Notes (contd..):- (f) All the minor complaint(s) will be addressed within 02 hours from the time of receipt of complaint. If, contractor or his tradesmen fails to attend the complaint within 02 hours from the time of receipt of complaint, the compensation/penalty of Rs. 500.00 (Rupees Five Hundred only) per complaint per hour for first 04 hours and after that Rs. 1000.00 (Rupees One Thousand only) per complaint per hour shall be recovered from the contractor’s dues. The decision of Accepting officer is this regard shall be final and binding. (g) The cost of transportation (to and fro) and other necessary equipment shall be arranged / brought by contractor to complete the job and no extra cost shall be paid to the contractor in this effect. (h) All the major complaints are required to be rectified within 24 hours or within stipulated time given by the JE/Engineer-in-Charge, if, contractor or his tradesmen fails to rectify the defects, the compensation of Rs. 2500.00 (Rupees two thousand Five Hundred only) per complaint for each date (i.e. 24 hours) shall be recovered from the contractor's dues. The decision of Accepting officer is this regard shall be final and binding.
Supply & fix in replacement of Recess mounting LED Backlit round down lighter made of Spun Aluminium with high efficient LEDs & Glass free opal diffuser, IP-20. suitable of lifts. Make Halonix/ Havells/ Crompton Greeves.
Supply & fix in replacement of Electric cabin fan 230 V, 85 W, RPM 1350 single phase 300 mm sweep. Make As per sample
Supply & fix in replacement of SMF Battery 12 V 7 Ah complete all as specified and directed. Make Exide/ Amron/luminious. Note:- Old unserviceable batteries shall be deposited to MES store yard.
Supply & fix in replacement of UPS (ARD) 3000 VA complete all as specified and as directed. Make As per sample
M/s Dhapola Elevator and Engineering
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .