GE AF THANE
The Garrison Engineer (AF) Thane Kolshet Road, Sandoz Baugh Post, Thane 400607
REPAIR, MAINTENANCE CEILING FAN, EXHAUST FAN, WALL MOUNTED FAN, PADESTAL FAN, METER, INTERNAL WIRING, FITTING AND FIXTURE AND ALLIED WORKS AT AF STN KANHERI HILLS UNDER GE AF THANE
2021_MES_431696_1
8988/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
THANE
AS PER NIT
8 documents required · 8 mandatory
₹500
GE AF THANE
₹76,000
Yes
28 Aug 2021
18 Mar 2021
27 Apr 2021
18 Mar 2021
26 Apr 2021
14 Apr 2021
18 Mar 2021 - 14 Apr 2021
Amount
M&L Taking down unserviceable Ceiling Fan 1200/1400 mm Sweep of any Make from the Site including deposit to AGE E/M Store Yard and carry out necessary repair and rehanging the same in Original Position, complete all as specified and as directed.
M&L Taking down unserviceable Exhaust Fan 230/300/400/450/600 mm Sweep of any Make from the Site including deposit to AGE E/M Store Yard and carry out necessary repair and rehanging the same in Original Position, complete all as specified and as directed.
M&L Taking down unserviceable Wall Fan/ 400/450 mm Sweep of any Make from the Site including deposit to AGE E/M Store Yard and carry out necessary repair and rehanging the same in Original Position, complete all as specified and as directed.
M&L Taking down unserviceable Padestal Fan / 400/450/600 mm Sweep of any Make from the Site including deposit to AGE E/M Store Yard and carry out necessary repair and rehanging the same in Original Position, complete all as specified and as directed.
M&L Dismantling Ceiling Fan 1200mm Sweep of any make and removing defective/ burnt Wiring, cleaning of Core/ Motor and re-winding of Fan with Supper Enameled Copper Wire of suitable gauge with Proper Insulation Material and replacement of defective Ball Bearing, Bushes & Other Accessories, complete all as specified and as directed. NOTE :- (a) Quoted Unit Rate is deem to be include for Nuts, Bolts, Split Pin, Washers, etc. as required at Site longwith re-winding of Fan. (b) Ball Bearing will be measured and paid under appropriate Items here-in-after.
M&L Dismantling Exhaust Fan 230/300/450mm/600 mm Sweep of any make and removing defective/ burnt Wiring, cleaning of Core/ Motor and re-winding of Fan with Supper Enameled Copper Wire of suitable gauge with Proper Insulation Material and replacement of defective Ball Bearing, Bushes & Other Accessories, complete all as specified and as directed. NOTE :- (a) Quoted Unit Rate is deem to be include for Nuts, Bolts, Split Pin, Washers, etc. as required at Site longwith re-winding of Fan. (b) Ball Bearing will be measured and paid under appropriate Items here-in-after.
M&L Dismantling Exhaust Fan 450mm/600 mm Sweep of any make and removing defective/ burnt Wiring, cleaning of Core/ Motor and re-winding of Fan with Supper Enameled Copper Wire of suitable gauge with Proper Insulation Material and replacement of defective Ball Bearing, Bushes & Other Accessories, complete all as specified and as directed. NOTE :- (a) Quoted Unit Rate is deem to be include for Nuts, Bolts, Split Pin, Washers, etc. as required at Site longwith re-winding of Fan. (b) Ball Bearing will be measured and paid under appropriate Items here-in-after.
M&L Dismantling Padestal Fan 400/450/600 Sweep of any make and removing defective/ burnt Wiring, cleaning of Core/ Motor and re-winding of Fan with Supper Enameled Copper Wire of suitable gauge with Proper Insulation Material and replacement of defective Ball Bearing, Bushes & Other Accessories, complete all as specified and as directed. NOTE :- (a) Quoted Unit Rate is deem to be include for Nuts, Bolts, Split Pin, Washers, etc. as required at Site longwith re-winding of Fan. (b) Ball Bearing will be measured and paid under appropriate Items here-in-after.
M&L Dismantling Wall Fan 400/450mm Sweep of any make and removing defective/ burnt Wiring, cleaning of Core/ Motor and re-winding of Fan with Supper Enameled Copper Wire of suitable gauge with Proper Insulation Material and replacement of defective Ball Bearing, Bushes & Other Accessories, complete all as specified and as directed. NOTE :- (a) Quoted Unit Rate is deem to be include for Nuts, Bolts, Split Pin, Washers, etc. as required at Site longwith re-winding of Fan. (b) Ball Bearing,Fan blade,bush,capacitor,fan regulator,plug top etc and other items required for rectification/maintenance shall be measured and paid under appropriate Items as a supply only.
Supply onlyBall Bearing 6201/6202 (as approved), complete all as specified and as directed. MAKE : NBC / SKF
Supply only Ball Bearing 6203/6204 (as approved), complete all as specified and as directed. MAKE : NBC / SKF
Supply only Blade suitable for Ceiling Fan 1200/1400 mm Sweep of any Make including taking down/out unserviceable one, complete all as specified and as directed
Supply only Blade suitable for Exhaust Fan 300/380mm Sweep of any Make including taking down/out unserviceable one, complete all as specified and as directed
Supply only Blade suitable for Exhaust Fan 400/450 mm Sweep of any Make including taking down/out unserviceable one, complete all as specified and as directed
Supply only Blade suitable for Exhaust Fan 600 mm Sweep of any Make including taking down/out unserviceable one, complete all as specified and as directed
Supply only Blade suitable for Wall Mounted Fan 400/450 mm Sweep any Make including taking down/out unserviceable one, complete all as specified and as directed
Supply only Bush of Gun Metal suitable for Ceiling Fan / Exhaust Fan/ Wall Mounted Fan of any Make and any size, complete all as specified and as directed.
Supply only Canopy suitable for Ceiling Fan 1200/1400mm Sweep of any Make including taking down/out unserviceable one, complete all as specified and as directed.
Supply only Capacitor 2.5 mfd, Oil immersed suitable for Ceiling Fan / Exhaust Fan/ Wall Mounted Fan of any Make and any size including taking down/out unserviceable one, complete all as specified and as directed. MAKE : AMCAP/ EPCOS/ HAVELL’S
Supply only Capacitor 3.15 mfd, Oil immersed suitable for Ceiling Fan / Exhaust Fan/ Wall Mounted Fan of any Make and any size including taking down/out unserviceable one, complete all as specified and as directed.
Supply only Capacitor 4.0 mfd, Oil immersed suitable for Ceiling Fan / Exhaust Fan/ Wall Mounted Fan of any Make and any size including taking down/out unserviceable one, complete all as specified and as directed.
Supply only Regulator, Electronic 5 Step Socket type, suitable for Ceiling Fan 1200/1400 mm Sweep and fixing including taking down/out unserviceable one, complete all as specified and as directed.
Supply only Plug top 6 A ISI marked Anchor/Havell's complete all as specified and as directed.
S&F Connection Lead consisting of PVC insulated Twin Core Flexible Wire of 23/.0076 for Ceiling/Exhaust Fan Connection including taking down/out unserviceable one, complete all as specified and as directed.
S&F Louvers suitable for Exhaust Fan 300/380/450/600mm mm in size of any Make and Type/Shape, fixed on Brick Wall and grouting of Nuts, Bolts and Washers including taking down/out unserviceable one, complete all as specified and as directed.
S&F Ready Made Frame suitable for Exhaust Fan 380/400/450mm in size of any Make and Type/Shape and fixing including taking down/out unserviceable one, complete all as specified and as directed.
S&F Mild Steel Clamp of any type /shape suitable for hanging Ceiling Fan 1200/1400 mm Sweep of any Make for holding of Capacitor with PVC Connection and Nuts, Bolts, Check Nuts, Split Pin,etc. including taking down/out unserviceable one, complete all as specified and as directed.
S&F GI Pipe15 mm bore (dia), 15 Cm to 50 Cm in length as Ceiling Fan Pipe Rod (as per existing) duly threaded including taking down/out unserviceable one, complete all as specified and as directed.
M&L for Cutting Brick Walls for fixing Exhaust Fan of size 225mm to 450mm Sweep and Making Good distrubed surfaces in Cement Mortar 1:3 including Surface Treatment by applying Distemper (Internally) and Cement Base Paint/ Weather Coat Emulsion Paint (Externally) to match the existing Colour, complete all as specified and as directed.
M&L for preparing old painted surfaces of Complete Ceiling Fan 1200/1400mm Sweep i.e. Holding Down Rod, Fan Blades, Fan Body, Canopies and removing old paint by scrapping, cutting, rubbing, etc. and filling of Putty as required, applying Two coats of Synthetic Enameled Paint (existing Colour of the Fan) by Spray Painting Machine, writing MES/SM No. on the Fan, complete all as specified and as directed. NOTE : Quoted Unit Rate shall deem to be include for Taking down/ lowering of Ceiling Fan after disconnecting Electric Connection and re-hanging the Fan in the same location after Painting and re-connection.
M&L for preparing old painted surfaces of Complete Exhaust Fan 300/380/450mm Sweep i.e. Frame, Fan Blades, Fan Body, Canopies and removing old paint by scrapping, cutting, rubbing, etc. and filling of Putty as required, applying Two coats of Synthetic Enameled Paint (existing Colour of the Fan) by Spray Painting Machine, writing MES/SM No. on the Fan, complete all as specified and as directed. NOTE : Quoted Unit Rate shall deem to be include for Taking down of Exhaust Fan after disconnecting Electric Connection and re-fixing the Fan in the same location after Painting and re-connection.
Taking down unserviceable Copper/Aluminium Point Wiring and Fixture and Fittings such as Switches, Ceiling Roses, Pendants, Regulators, Sockets, Light Fitting, etc., from the Point Wiring (Light, Fan, Socket or Power) without distrubing Conduits, complete all as specified and as directed.
Taking down the existing unservicable Sub-main Wiring of any type and any description as existing at Site including Making Good the Disturbed Surfaces of Walls, Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed.
Taking down the existing unserviceable Main Switch/ Cut out/ DBs of any type/ capacity and any description as existing at Site including Making Good the Disturbed Surfaces of Walls, Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed.
Taking down existing unservicable Sub-main Wiring of any description, Surface/Concealed type, taking out PVC Casing & Caping/ PVC Conduit/ ERW Conduit including necessary Chase cuttings on Brick Walls, Ceilings, Floors, etc. to remove/ taking out Conduit, etc., complete all as specified and as directed.
M&L for Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable drawn through/in EXISTING CONCEALED CONDUIT with Continuous Earth Wire 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable (Green Colour) connected to Main Earth Wire and Earth Dolly providing 3.0mm thick Hylam Sheet Top Cover ISI mark on existing Mild Steel Pressed Terminal Box 1.6mm thick, suitable for mounting Switches, Sockets, Fan Regulators etc. complete all as specified and as directed. For the following:-
For ONE LIGHT/FAN POINT CONTROLLED BY ONE 1-WAY SWITCH 6 AMP, complete all as specified and as directed.
For ONE CALL BELL POINT CONTROLLED BY ONE 1-WAY BELL PUSH SWITCH 6 AMP, complete all as specified and as directed.
For ONE 3 PIN SOCKET OUTLET 6 AMP ON THE INDEPENDENT BOARD, complete all as specified and as directed.
For ONE 3 PIN SOCKET OUTLET 6 AMP ON THE SAME BOARD, complete all as specified and as directed.
M&L for Point Wiring with 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable drawn through/in EXISTING CONCEALED CONDUIT with Continuous Earth Wire 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable (Green Colour) connected to Main Earth Wire and Earth Dolly providing 3.0mm thick Hylam Sheet Top Cover ISI mark on existing Mild Steel Pressed Terminal Box 1.6mm thick, suitable for mounting Switches, Sockets, Fan Regulators, etc. for ONE 3 PIN SOCKET 16 AMP ON INDEPENDENT BOARD, complete all as specified and as directed.
M&L for Point Wiring with 4.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable drawn through/in EXISTING CONCEALED CONDUIT with Continuous Earth Wire 4.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable (Green Colour) connected to Main Earth Wire and Earth Dolly providing 3.0mm thick Hylam Sheet Top Cover ISI mark on existing Mild Steel Pressed Terminal Box 1.6mm thick, suitable for mounting Switches, Sockets, Fan Regulators, etc. ONE 3 PIN SOCKET 16 AMP ON INDEPENDENT BOARD, complete all as specified and as directed. Make of Cable : Anchor / Havells / Plaza / Polycab
M&L for Sub-main Wiring with 2-Runs of 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable drawn through in existing conduit /PVC casing and caping and making good the disturbed surface of wall including 1-Run of 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable (Green Colour) as Earth Continuty Conductor along with the Wiring in Concealed and Making Good Disturbed Surfaces of Walls/Roofs/Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed.
M&L for Sub-main Wiring with 2-Runs of 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable drawn through in existing conduit /PVC casing and caping and making good the disturbed surface of wall including 1-Run of 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable (Green Colour) as Earth Continuty Conductor along with the Wiring in Concealed and Making Good Disturbed Surfaces of Walls/Roofs/Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed.
M&L for Sub-main Wiring with 2-Runs of 4.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable drawn through in existing conduit /PVC casing and caping and making good the disturbed surface of wall including 1-Run of 4.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable (Green Colour) as Earth Continuty Conductor along with the Wiring in Concealed and Making Good Disturbed Surfaces of Walls/Roofs/Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed.
M&L for Sub-main Wiring with 2-Runs of 6.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable drawn through in existing conduit /PVC casing and caping and making good the disturbed surface of wall including 1-Run of 6.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable (Green Colour) as Earth Continuty Conductor along with the Wiring in Concealed and Making Good Disturbed Surfaces of Walls/Roofs/Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed.
M&L for Sub-main Wiring with 2-Runs of 10 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable and 1-Run of 10 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty along with the Wiring drawn in existing conduit /PVC casing and caping, complete all as specified and as directed. Note:- Cost of all Cables as mentioned in the BOQ Items will deem to be included in the Quoted Unit Rate and will be Measured and Paid as One Unit.
M&L for Sub-main Wiring with 2-Runs of 1.5 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable and 1-Run of 1.5 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty, drawn through and including Non-metalic Rigid PVC Conduit of size 25mm dia, medium grade, ISI marked with necessary Conduit Accessories, Concealed/grouting Conduit on Brick Walls, etc. and Making Good disturbed Surfaces of Brick Walls, Ceilings, Floors, etc. in Cement Mortar 1:3 and necessary Surface Treatments so as to match with the Existing Finishes, complete all as specified and as directed.
M&L for Sub-main Wiring with 2-Runs of 2.5 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable and 1-Run of 2.5 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty, drawn through and including Non-metalic Rigid PVC Conduit of size 25mm dia, medium grade, ISI marked with necessary Conduit Accessories, Concealed/grouting Conduit on Brick Walls, etc. and Making Good disturbed Surfaces of Brick Walls, Ceilings, Floors, etc. in Cement Mortar 1:3 and necessary Surface Treatments so as to match with the Existing Finishes, complete all as specified and as directed.
M&L Sub-main Wiring with 2-Runs of 6.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable and 1-Run of 6.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty, drawn through and including Non-metalic Rigid PVC Conduit of size 25mm dia, medium grade, ISI marked with necessary Conduit Accessories, Concealed/grouting Conduit on Brick Walls, etc. and Making Good disturbed Surfaces of Brick Walls, Ceilings, Floors, etc. in Cement Mortar 1:3 and necessary Surface Treatments so as to match with the Existing Finishes, complete all as specified and as directed.
M&L for Sub-main Wiring with 2-Runs of 10 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable and 1-Run of 10 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty, drawn through and including Non-metalic Rigid PVC Conduit of size 25mm dia, medium grade, ISI marked with necessary Conduit Accessories, Concealed/grouting Conduit on Brick Walls, etc. and Making Good disturbed Surfaces of Brick Walls, Ceilings, Floors, etc. in Cement Mortar 1:3 and necessary Surface Treatments so as to match with the Existing Finishes, complete all as specified and as directed. (a) Cost of all Cables (as mentioned in the BOQ/DCS Items) and 1-Run PVC Conduit with all Accessories/ Fittings will deem to be included in the Quoted Unit Rate and will be Measured and Paid as One Unit. (b) Sub-main Wiring will be measured PVC Conduit only. Wire required for looping, etc. as ordered will deem to be included in the Quoted Unit Rate.
M&L for Flame Proof Sub-main Wiring with 2-Runs of 6.0 Sqmm Single Core, Halogen Free Flame Retardant (HFFR) insulated, unsheathed, multi-stranded, 1100 Volt grade, Copper Conductor Cable and 1-Run of 6.0 Sqmm Earth Wire of Single Core, Halogen Free Flame Retardant (HFFR) insulated, unsheathed, multi-stranded, 1100 Volt grade, Copper Conductor Cable (Green Colour), drawn through EXISTING ERW CONDUIT, complete all as specified and as directed.
M&L for Flame Proof Sub-main Wiring with 2-Runs of 6.0 Sqmm, Single Core, Halogen Free Flame Retardant (HFFR), insulated, unsheathed, multi-stranded, 1100 Volts grade, Copper Conductor Cable and 1-Run of 6.0 Sqmm Earth Wire of Single Core, Halogen Free Flame Retardant (HFFR), insulated, unsheathed, multi-stranded, 1100 Volts grade, Copper Conductor Cable, drawn through and including ERW Conduit 25mm dia, heavy duty with necessary Conduit Accessories such as Tee, Bend, Elbow, Junction Box duly tested and Certified by CIMFR DHANBAD & CCOE NAGPUR, BS with ISI marked, Concealed/grouting Conduit on Brick Walls, etc. and Making Good disturbed Surfaces of Brick Walls, Ceilings, Floors, etc. in Cement Mortar 1:3 and necessary Surface Treatments so as to match with the Existing Finishes, complete all as specified and as directed.
S&F PVC Casing & Capping, ISI marked, heavy duty of size 25mm with all Fittings including taking down old unserviceable one, complete all as per specified and as directed. MAKE : AKG/KALINGA/KINJAL/POLYCAB/SUPREME
S&F PVC Conduit, ISI marked, heavy duty of size 25mm with all Fittings including taking down old unserviceable one, complete all as per specified and as directed.
S&F PVC Conduit 32 mm dia, medium grade with necessary Conduit Accessories such as Tee, Bend, Elbow, Junction Box, etc. ISI marked including taking down/out unserviceable PVC Conduit with Fittings, complete all as specified and as directed.
S&F ERW Conduit 25mm dia, heavy duty with necessary Conduit Accessories such as Tee, Bend, Elbow, Junction Box duly tested and Certified by CIMFR DHANBAD & CCOE NAGPUR, BS with ISI marked including taking down/out unserviceable ERW Conduit with Fittings, complete all as specified and as directed.
S&F Industrial Grade Plug and Socket IEC 60309 with Industrial Grade Enclosure (IP-44) Material should be PC/ABS type and 16 Amp MCB (BS: 3871), ISI marked and Elecrically Connecting up including taking down/out unserviceable Plug and Socket with Enclosure, complete all as specified and as directed. MAKE : HENSEL AR 110 306 TS /INDO ASIAN
S&F Switch Piano 6 Amp, Flush type, Single Pole, 1-way, complete all as specified and as directed. MAKE : ANCHOR/CRABTREE(SCHNEIDER) LEGRAND
S&F Switch Piano 16 Amp, Flush type, Single Pole, 1-way, complete all as specified and as directed. MAKE : ANCHOR/CRABTREE(SCHNEIDER) LEGRAND
S&F Switch Piano 6 Amp, Flush type, Push Button, suitable for Call Bell, complete all as specified and as directed. MAKE : ANCHOR/CRABTREE(SCHNEIDER) LEGRAND
S&F Socket Outlet 6 Amp, Piano, Flush type, 2-in-1, multi-purpose, 3 Pin, complete all as specified and as directed. MAKE : ANCHOR/CRABTREE(SCHNEIDER) LEGRAND
S&F Socket Outlet 6 Amp & 16 Amp, Piano, Flush type, 2-in-1, multi-purpose, 5 Pin, complete all as specified and as directed. MAKE : ANCHOR/CRABTREE(SCHNEIDER) LEGRAND
S&F Lamp Holder, Insulated body PVC/Polycarbonate with Back Plate suitable for Batten Fitting, complete all as specified and as directed.
S&F Call Bell Electric Single Pole, 230 Volt, AC supply, Ding Dong type complete all as specified and as directed.
S&F Ceiling Rose, 3 Terminals, PVC Polycarbonate, Isolated body complete all as specified and as directed.
S&F Fan Regulator in 5 Step type, Single Pole, 230 Volt, Electronic type, complete all as specified and as directed.
S&F Decorative Ultra Slim Linear LED Lighting Fixture with Extruded Polycarbonate, Environmental Friendly, Energy Efficient 5 Watt LED 6000K and connecting up with and including Copper Conductor Cable of size 23/0.0076 multi-stranded, 3 Core from Ceiling Rose to Light Fitting, complete all as specified and as directed. MAKE : HAVELLS Cat Part No. LHEXBLP7UN1W018 or C&S ELEECTRIC/ SURYA ROSHNI LTD/SYSKA LED (as approved by GE)
S&F LED Light Fitting 6.0 Watt 6000K, Surface mounted Square/Round shaped (as available) LED downlighter with durable Housing with Aluminum Heat Sink with Diffuser to give Glare Free Light with Removable Driver, complete all as specfied and as directed. MAKE : HAVELLS Cat Part No. LHEAARP7UL1W006 or C&S ELEECTRIC/ SURYA ROSHNI LTD/SYSKA LED (as approved by GE)
S&F Decorative Wall Light Fixture made up of Polycarbonate with LED Lamp 0.5 Watt (Red/Blue/Green) (B-22 Base) Light fixed on the Wall/ Ceiling and connecting up with and including Copper Conductor Cable of size 23/0.0076 Sqmm 3 Core PVC Copper Flexible Conductor and necessary Earthing Connection from Ceiling Rose to Light Fitting complete all as specified and as directed. MAKE : HAVELLS Cat Part No. LHFOFTE1TZ1W012 or C&S ELEECTRIC/ SURYA ROSHNI LTD/SYSKA LED (as approved by GE)
S&F Decorative Ultra Slim Linear LED Lighting Fixture with Extruded Polycarbonate, Environmental Friendly, Energy Efficient 10 Watt LED 6000K and connecting up with and including Copper Conductor Cable of size 23/0.0076 multi-stranded, 3 Core from Ceiling Rose to Light Fitting, complete all as specified and as directed. MAKE : HAVELLS Cat Part No. LHEXBTP7UN1W009 or C&S ELEECTRIC/ SURYA ROSHNI LTD/SYSKA LED (as approved by GE)
S&F Decorative Ultra Slim Linear LED Lighting Fixture with Extruded Polycarbonate, Environmental Friendly, Energy Efficient 18 Watt LED 6000K and connecting up with and including Copper Conductor Cable of size 23/0.0076 multi-stranded, 3 Core from Ceiling Rose to Light Fitting, complete all as specified and as directed. MAKE : HAVELLS Cat Part No. LHEXBLP7UN1W018 or C&S ELEECTRIC/ SURYA ROSHNI LTD/SYSKA LED (as approved by GE)
S&F LED light fitting 42 Watt of size 595 x 595x11.5mm comprising of rectangular shape Die-cast aluminium housing with weather proof with extra driver for each fitting including all accessories , compartment with system wattage of 40W. The LED make must be CREE/NICHIA/OSRAM with 120 degree view angle, > 120 lumen/watt. The driver must be integral APFC and constant current type having THD<10% and power factor >0.95 with short circuit protection, open circuit protection, reverse polarity protection, high voltage protection and comply to IEC 60598-1, IEC 61000-3-2, IEC 61547. The luminaire must have secondry optics with perfectly matched lens for better light control complete all as specified and as directed. Make : Bajaj/Surya/Havells/HPL
S&F MCB Single Pole, 6 to 32 Amp, 240 Volt, AC, 'B' Series for fixing on MCB DB’s, 10 kA, 50 Hz and connecting up, complete all as specified and as directed.
S&F MCB Single Pole & Neutral, 40 Amp, 240 Volt, AC, 'B' Series for fixing on MCB DB’s, 10 kA, 50 Hz and connecting up, complete all as specified and as directed.
S&F MCB 4 Pole, 63 Amp, 415 Volt, 50 Hz, ISI marked and connecting up including taking down/out unserviceable Isolator, complete all as specified and as directed.
S&F MCCB 4 Pole, 415 Volt, Adjustable type, 100 Amp with breaking capacity 36 kA incl electrically connecting up complete all as specified and directed.
S&F MCCB 4 Pole, 415 Volt, Adjustable type, 160 Amp with breaking capacity 36 kA incl electrically connecting up complete all as specified and directed.
S&F MCCB 4 Pole, 415 Volt, Adjustable type, 200 Amp with breaking capacity 36 kA incl electrically connecting up complete all as specified and directed.
S&F Sheet Metal Enclosure, Single Pole & Neutral with a 2-Pin and Earth Plug and Socket with 1 No. MCB Single Pole, 20 Amp, 240 Volt and connecting up, complete all as specified and as directed.
S&F MCB DB 4-way, Single Pole & Neutral, Double Door type, Regal Grey Colour, Sheet Steel Phosphatised, Powder Coated with 200 Amp rate Bus-bar, Neutral Link Earth Bar & Din Rail duly embedded in Wall including Concealed upto Wall Surface including connecting with existing Cable Incoming and Outgoing with Cable Lugs as per the requirement and and Making Good Disturbed Surfaces of Walls/Roofs/ Floors, etc. so as to match with the existing Finishes, complete all as specified and as directed.
S&F MCB DB 8-way, Single Pole & Neutral, Double Door type, Regal Grey Colour, Sheet Steel Phosphatised, Powder Coated with 200 Amp rate Bus-bar, Neutral Link Earth Bar & Din Rail duly embedded in Wall including Concealed upto Wall Surface including connecting with existing Cable Incoming and Outgoing with Cable Lugs as per the requirement and and Making Good Disturbed Surfaces of Walls/Roofs/ Floors, etc. so as to match with the existing Finishes, complete all as specified and as directed.
S&F Load Line TPN Enclosure, 8-way, Double Door with Incomer MCCB 160 Amp rating, 25 kA, 4 Pole and suitable for 415 Volt, 50 Hz, AC Supply and connecting up including taking down/ out unserviceable Load Line TPN Enclosure, complete all as specified and as directed.
S&F Load Line 4-way Enclosure Double Door with Incomer MCCB 100 Amp rating, 25 KA, 4 Pole and suitable for 415 Volt 50 Hz AC Supply including taking down old unserviceable one, complete all as per specified and as directed.
S&F Flame Proof Distribution Box SPN, 4-way with Bus-bar Weather Proof in Cast Aluminium LM-6 Enclosure, opened by externally Spring type knobs, complete with M-25 Cable Entry to suit Incoming Cable and 4 No. M-20 Cable Entries for Out-going Cables from bottom, suitable for fixing on Wall/ Column/ Sheet Structure, etc. duly Epoxy Powder Coated with Flame Proof Flexible Metallic Conduit upto 1.0 Metre in length including MCB SPN 40 Amp (1 No.) and MCB SP upto 25 Amp (2 No.) as Out-going duly Tested and Certifed by CIMFR DHANBAD & CCOE NAGPUR, BS with ISI marked and connecting up including taking down/ out unserviceable Distribution Box, complete all as specified and as directed.
Excavation in Trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth for taking out/laying of UG Cable, etc. including forming bottom surface to required Level and Gradient in Soft/ Loose Soil and getting out, complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 Cm in Soft/ Loose Soil, complete all as specified and as directed.
Removing excavated materials not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the starting point, complete all as specified and as directed.
Making Hole under Road/ Hardstanding horizontally including cutting, etc. with Manual Anger or Bookie, not exc. 100mm dia, complete all as specified and as directed.
Supply & laying XLPE insulated, Screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electric Power Cable Earthed, heavy duty, 1100 Volt grade with Aluminium Conductor, ISI marked, IS:7096, Cross sectional area 10 Sqmm, 4 Core, laid in Trenches, Duct, through Pipe or laid in Floor or fixing to Pole, jointing and testing including taking down/ out Cable, complete all as specified and as directed. MAKE : FINOLEX/ HAVELLS/ RPG/ UNIVERSAL CABLES
Supply & laying XLPE insulated, Screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electric Power Cable Earthed, heavy duty, 1100 Volt grade with Aluminium Conductor, ISI marked, IS:7096, Cross sectional area 25 Sqmm, 3½ Core, laid in Trenches, Duct, through Pipe or laid in Floor or fixing to Pole, jointing and testing including taking down/ out Cable, complete all as specified and as directed. MAKE : FINOLEX/ HAVELLS/ RPG/ UNIVERSAL CABLES
M&L Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, punned thickness of Sand Cushioning only will be Measured.
Supply and lay in trenches PCC cable cover class LV, type 1, flat of size 250 mmx150 mmx 40 mm for cable protection all as specified and directed.
M&L for Galvanised Steel Tubing Pipe 50mm bore (dia), light grade with Bend, laid in Trenches or under Road/Floor/Culverts or fixing to Walls, Poles, etc. including taking down/ out GI Pipe, complete all as specified and as directed. MAKE : BST/ JINDAL PIPES/ PRAKASH TUBES/ TATA
M&L Cement Concrete 1:3:6 (40mm graded stone aggregate) for Filling and Mass Concrete in Road/ Hardstanding Cuttings) etc. including making surface good to match with the existing Finish Level, complete all as specified and as directed.
M&L for Earthing with Galvanised Steel Earth Plate Electrode 600x600x6mm, buried directly in ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connected to Galvanised Earth Lead Wire 4.0mm dia by means of Bolts, Nuts, Check, Nuts and Washers of Galvanised Iron or Steel and Earth Wire protected with and including GI Pipe 15mm bore (dia) light grade, connected to Test Point upto 7.50 Metre away from Earth Electrode situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc.150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down/ out unserviceable Earthing, complete all as specified and as directed.
Material and labour for Checking/ Testing of resistance value of any type of earth pits by disconnecting earth continuity conductor from test terminal block/panel/equipment at various location of AF Station Kanheri Hills and reconnecting the earth continuity conductor after testing.Temporary earthing connection to be provided while testing.Earth tester will be provided by contractor. Earth tester must be calibrated. Contractor has to prepare sketch of earthings indicating the locations in surrounding of bldgs and give the earthing No. , type of earthings i.e earthing for AF Equipments (EQ1 , EQ2 etc), lightning protection earthing (LA1, LA2 etc) & Power supply earthing (PS1, PS2 etc).Earth test results shall be recorded in reference to sketch. Earth test to be signed by Rep of contractor, Rep of MES and Rep of AF. Test reports to be submitted in triplicate
M&L for Repairing Damaged Earth Pit/Chamber in Cement Concrete 1:3:6 (20mm graded stone aggregate) as shown in Electrical Plate No 3 of MES Schedule Part-I including providing Pre-cast RCC Cover in Cement Concrete 1:2:4 (20mm graded stone aggregate) of 350x350x50mm in size, reinforced with and including 10mm dia TMT Bars @ 100mm Centre to Centre in both ways including Funnel and cleaning the surrounding of Earth Pit Cover and pouring Salt Water to improve the resistace and measuring and recording the same in presence of Engineer-in-Charge, complete all as specified and as directed.
M&L for Checking of any breaking in the Link of Earth Strip/Wire of Galvanised/ Copper/Aluminium any size and jointing them by Exothermic Welding or Brazing, complete all as specified and as directed.
M&L for Taking out loose/displaced Serviceable Aluminium Strip/ Copper Strip/ GI Strip of any size and any description with Accessories and refixing the same with necessary Fixing Arrangement like Screws, Saddles, Nuts and Bolts, complete all as specified and as directed. NOTE : Cost of Screws, Saddles, Nuts and Bolts, etc. will deemed to be included in the Quoted Unit Rate.
S&F Copper Strip 20x3.15mm with Saddles and fixing Screws for Roof/ Earth Conductors and Down Conductors above Ground including taking down unserviceable Strip, complete all as specified and as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
S&F Galvanised Iron Strip 32x6mm with Saddles and fixing Screws for Roof/Earth Conductors and Down Conductors above Ground including taking down unserviceable Strip, complete all as specified and as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
S&F Aluminium Strip 25x3.15mm with Saddles and fixing Screws for Roof/ Earth Conductors and Down Conductors above Ground all Joints should be connected by Exothermic Welding or Brazing including taking down unserviceable Strip, complete all as specified and as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
S&F Galvanised Iron Tubing/Pipe 40/50 mm bore (dia), light grade for Strip Protection, fixed in Walls/Floors with suitable type of Clamps, etc. including taking down unserviceable GI Tubing/Pipe, complete all as specified and as directed.
S&F Test Point Terminal Block made of Gun Metal or Phosphorus Bronze size 75x75x25mm, drilled and screwed including 3 No. 8mm dia, 25mm long hexagonal Head Screw including taking down/out unserviceable Test Point Terminal Block, complete all as per specified and as directed.
Supply and fix in replacement of single pointed soild copper rod 300mm long and 12mm dia fixed on suitable flat mounted plate and connected with roof/dowen conductor all as specified and directed
Fixing-in-repairs only Air Termination Single Pointed copper Rod dia upto 12mm and length upto 300mm including provision of Cement Concrete 1:2:4 (20mm graded stone aggregate) Block 300x300x300mm and necessary Fixing Arrangement at Roof, complete all as specified and as directed. NOTE : If threaded of the Rod is damaged then Contractor will be responsible for cutting of thread for fixing the Rod.
S&F Mild Steel Sheet of size approximate 300x200x1.6mm thick Sheet Egg type, Half round type, Rectangular type and Triangular type with welded 1ʺ (Inch) dia 2ʹ (Feet) long Mild Steel Pipe with duly different Synethic Enameled Paint cutting of Equipment Earthing/ Lighting Arrester Earthing/ Signal Earthing, etc. complete as specified duly painted as specified and marking of Earth Plate Number/ Description of Earthing/Type of Earthing on Plate with White Paint including Earth Plate No. and Earthing Resistance with Earthing Check Date and Earthing Check Due Date including taking down unserviceable one, complete all as specified and as directed.
S&F in repair of GI tubing 15 mm bore 'medium grade' including all necessaory fittings i.e. socket, elbow etc.laid on floor or fixed to wall complete all as specified and directed by Engr-in-charge.
S&F Stop valve of 15mm dia complete as directed.
M&L for Cutting the existing GI pipe upto 80mm for tapping of 15 mm branch including required fittings complete all as specified and as directed.
S&F Arrester Clamp for Lighting Arrester of size 16mm made out Brass including taking down unserviceable Arrester Clamp, complete all as specified and as directed.
Supply, installation, testing of CPRI tested maintenance free earthing system a set of Copper Bonded Earth Rod of 3 meter length, 17.2 mm dia made of high tensile low carbon steel circular rods, molecularly bonded with 99.9% electrolytic grade copper on outer surface (minimum copper bonding thickness-250 microns) with exothermically jointed copper bus bar of 150x25x5mm for long lasting and connection. Each copper bonded rod & exothermically jointed bus bar should be CPRI tested on 25 KA fault current. Earth rod should be used with 50 kg earth enhancing compound tha should be ROHS tested & having passed leaching, Sulphur, Corrosion, Resisitivity Test as per IEC-62561-7- an international standard for Earth Enhancement Compound by NABL accredit Lab, and PVC pit cover=1 Nos Note- (i) Vendors are bound to get earthing result less than or upto1 Ohm with or without the grid of earthing.(Maximum number of new earthings in grid are restricted to 3 nos) Any additional work and material required to achieve the required result is included in the cost. (ii) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled. (iii) Refill the pit with black cotton soil. (M&L for black cotton soil must be included in the quoted rate)
Material and labour for supply, installation, testing and commissioning of GI pipe electrode earthing maintenance free earthing based on 6 mtr long GI pipe 80 mm dia(ID) medium grade, GI strip 32x6 mm (Strip in pipe type electrode) and GI pipe electrode shall be filled with MFC for improvement of conductivity of electrode, 120 KGS approx of BFC shall be filled around the GI pipe electrode including providing FRP pit cover of size 250mm at top ,330mm at bottom and 260mm in height capable to withstand minimum 2 ton driving load.Rate included for testing,commisioning including checking of earth continuity and earth result complete all as specified and directed.Vendors are bound to get earthing result less than or upto 5 Ohm with or without grid of earthings(Maximum number of new earthings in grid are restricted to 3 nos) GI strip required for interconnection of earth pits in grid must be laid 2 ft below the ground level and the same must be treated with chemical (BFC) if required to achieve resistance value. Any additional work and material required to achieve the required result is included in the cost. Rate is included for boring of earthing in any type of soil/rock upto 200 mm bore. Continuity of good earth resistance shall maintained upto 1 year and testing will be carried out monthly by MES authority.GI strip must be connected with GI pipe electrode and other joints through nut bolt in addition to welding.
M&L for providing earthing complete with Copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to copper earth strip 20 x 3 mm by means of bolts, nuts, checknuts & washers of copper and connecting to test point , providing charcoal and common salt and last layer of 60 cm of MagnesiumSalphate,all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs, including copper earth strip 20 x 3 mm , 7.5 meter long, etc complete all as specified. Note- (i) Vendors are bound to get earthing result less than or upto1 Ohm with or without the grid of earthing.(Maximum number of new earthings in grid are restricted to 3 nos) Any additional work and material required to achieve the required result is included in the cost. (ii) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled. (iii) Refill the pit with black cotton soil. (M&L for black cotton soil must be included in the quoted rate)
AMC FOR DG set 500 KVA Make Kirloskar through authorise service agency of OEM. Location: Site AF Stn Kanheri Hills, Note:- spares required for above maint will be measured and paid separately under relevent items . Scope Of Work :-
Srl Item NO 98.00 Contd../- (a) Engine Cooling System :- Checking of radiator conditions (check for radiator clogging, cooling fins condition, V belts, etc. Checking of K-Cool Super level, piping corrosions & any sign of radiator leaks. Checking of hoses & connections deterioration / wear & tear. C Checking of fan pulley mis-alignment / deterioration, defective bearings, corroded surface, grease condition. Checking the water pump leaks, noisy operation, abnormal vibration, impeller defects, cracked housing, worn out shaft, etc Checking of belts tension & deterioration. Checking thermostat for proper functioning. Checking water level sensor in radiator for K-Series Engines . b) Engine Fuel System :- Checking fuel lines connections (any signs of fuel leak, loose connections, corroded piping, fuel restrictions, defective clamps, deteriorated hose, etc.). Checking governors & controls conditions (any sign of deterioration, loose connections & system malfunction/ not responding etc.). Checking governors & controls conditions (any sign of deterioration, loose connections & system malfunction/ not responding etc.) Checking actuator of electronic governing system. Checking priming pump condition. Checking fuel filter condition – replace the filters as found necessary. Checking water separator condition. Checking fuel tank condition (any sign of water contamination, no water drain, corrosions / deteriorations, etc. Checking exhaust smoke condition to identify health of the engine. (c) Engine Lubricating System Inspection :- Checking oil lines connections (any signs of oil leak, loose connections, corroded piping, defective clamps, deteriorated hose, etc. Checking oil pressure condition (any sign of erratic operation, defective gauges, defective pressure sensors, defective wiring harness, etc. Checking oil level & oil quality condition.Checking last oil change & oil filter replacement. Checking make up oil availability at site.
Srl Item NO 98.00 Contd../-(d) Engine Air Induction System :-Checking air filter indicator reading (any sign of defective sensor, erratic operation).Checking air filter (any sign of filter clogging, dirt accumulation, air obstruction, defective seal, damage/ deteriorated housing etc.Checking turbocharger condition (any sign of excessive end play, oil/ gas leak, abnormal operating noise, excessive vibration, overheating etc.)Checking hoses & connections deterioration / wear & tear.Checking Charge Air cooler condition- if any (sign of clogged core/ fins, air leaks at connections, damaged gaskets, etc. (e) Engine Exhaust System :- Checking the exhaust manifold condition (any sign of gas leak, missing bolts and nuts, red hot manifold, oil leak, deterioration etc.Checking the flexible bellow/ hoses & connections deterioration / wear & tear.Checking muffler condition (any sign of support insufficiency, corrosion, drain pipe valve not installed, not shielded, etc). Checking exhaust pipe insulation condition / deterioration.Checking smoke emission quality (any sign of excessive black smoke, bluish smoke, white smoke, restricted gas flow etc.
Srl Item NO 98.00 Contd../-(f) Engine Electrical System :- Checking batteries condition (electrolyte level, distilled water level, defective plate, voltage drop during cranking-refer to manufacturer acceptable voltage drop, etc..), Battery capacity evaluation this can be done by battery discharge test. Replacement of batteries is to be planned. Checking the starting motor condition (any sign of defective solenoid, defective brushes, grounded / shorted connection, struck up rotor etc. Checking the wiring harness condition (any sign of defects, grounded, loose connections, shorted, open circuit, any deterioration. (g) Generator Control Panel System Inspection :- Checking “start / stop / manual switch condition & functionality. Checking “voltmeter”, “Ammeter”, “frequency “ meter for proper functionality.Checking “voltmeter”, “Ammeter”, “frequency “ meter for proper functionality. Checking “Contactors, ACB for proper functioning /operations. Checking “wiring termination for proper tightness. Checking indicating lamps for proper functioning. Checking if fault/tripping circuits are working satisfactory. Checking if doors are closing properly. Checking if there is no blockage of air from rear ducts. Checking if the front opening is directing the hot air outside room.
Srl Item NO 98.00 Contd../-(h) AMF Panel : Checking the all connection of contractor, MCCB, cable connection and rectify the defect if found any. NOTE:- any spare parts required for maintenance will be measured and paid separately in under relevent items. ) all as specified and directed.
Material and labour for Calibration of FIP and fuel injector from the authorized dealer, including petty repairs and replacing the suction & delivery valves, rollers to make the FIP and injectors functional for the capacities of DG set 500KVA ( calibration and repair to be carried out through authorized MICO test bench and test certificate to be submitted by the contractor
Supply and filling in replacement/topping up engine oil multi grade 15W to 40W in engine all as specified and directed. (Make KEOL Oil / Castrol /HP)
Supply and filling Coolant for radiators
Supply & fixing Fuel filter 500KVA Kirloskar P/N 4005400218 all as directed. Make : Kirloskar Green.
Supply & fixing Oil filter 500KVA Kirloskar P/N 65.05510.5020B all as directed. Make : Kirloskar Green.
Supply & fixing Air filter 500 KVA kirloskar P/N KV0.505.02.0.00 all as directed. Make : Kirloskar Green
Supply & fixing Fuel filer Prelimary 500 KVA 5 Ltr all as directed.Make: Kirloskar Green
Supply & fixing Belt Kirloskar 500 KVA P/N. 65.968001.0195A all as directed. Make Kirloskar Green
Supply & fixing Fuel Hose set Kirloskar 500 KVA all as directed . Make : Kirloskar
Supply & fixing Feed Pump as sly 500 KVA all as directed. Make : Kirloskar green
Supply & fixing Coolant Hose set Kirloskar 500 KVA all as directed. Make : Kirloskar Green
Supply & fixing return oil pipe with suitable size nozzle for DG 500 KVA Make Kirloskar set of any capacity.
Supply & fixing Lube oil pressure pipe with suitable size nozzle for DG Set 500 KVA Make Kirloskar
Supply & fixing Fuel pipe with suitable size nozzle for DG set 500 KVA capacity.
Supply & fixing Nut M-8 for DG set 500 KVA Make Kirloskar complete all as specified and as directed
Supply and fixing Stop solenoid switch 24 Volts suitable for 500 KVA Make Kirloskar .
Supply and fixing Oil pressure gauge 500 KVA Make Kirloskar complete all as directed
Supply and fixing AVR for 500 KVA Kirloskar Green make alternator all as directed.
Taking down and Supply and fixing self starter 24 volt DC for DG Set 500 KVA Make Kirloskar
Supply & fixing Digital Meter suitable for AMF panel for DG set 500 KVA Make Kirloskar
Supply & fixing Indicator lamp suitable for AMF panel for DG Set 500 KVA Make Kirloskar
Supply & fixing Three pole power contractor ,Type -MNX ,Aux contacts 2NO=2NC ,Catno-CS94137 suitable for AMF panel for DG Set 500 KVA Make Kirloskar
Supply & fixing AC control contractor -MO -25 AC-25 45A at 415 volt ,Catno-CS94567 suitable for AMF panel for DG Set 500 KVA Make Kirloskar
Supply & fixing DC control contractor -MNO22(2NO+2NC) AC-15 4A at 415 volt, Catno-CS94667 suitable for AMF panel Make: L&T DG Set 500 KVA Kirloskar
Taking down unserviceable change over switch and Supply and fixing on load change over switch 630 amps ,415 volt AC, Make Havells for DG Set 500 KVA complete all as directed.
Taking down and Supply and fixing Battery terminal made with brass for 24 volt battery for DG Set 500 KVA complete all as specified and as directed
Taking down sylencer pipe of the DG set of any capacity and dismentling asbestous rope decarbonizing the sylincer and Supply and fixing heat proof asbestors rope 12mm dia on engine exhaust pipe including dismantling of worn out Asbestors rope and minor welding/tightening in leakage exhaust conforming to ISI specification fire proof/flame proof all as specified and directed.
Supply & fixing starter push bottom for 500 kva DG set complete all as specified and as directed
Taking down and Supply Battery 12 V, 180 H, 24 Plate compl;ete all as specified and directed
Taking down and Supply and fixing self starter 24 volt DC
Material with labour for painting the aquistic enclosure, Diesel engine , alternator, AMF panel with two coat of synthatic enamel paint after necessary scrapping the old paint, denting the damage portion complet all as directed.
Taking down unserviceable change over switch and Supply and fixing on load change over switch 200 amps, 415 volt AC, Make Havells for DG Set 500 KVA complete all as directed.
S&F Solar LED Street Light Fitting of capacity 50 Watt with Motion Sensor based, Peak Lux Sensor on 37@7M, Eco friendly, User friendly, no UV/Mercury, Pressure Die Cast Aluminium Body, Maintenance Free Lithiumion Batteries of suitable capacity dully intenally fitted, Solar Panel Mono Crystalline Photo Voltaic Module of capacity 75 Watt with all Accessories and connecting up with Copper Conductor Cable of suitable size including Taking down unserviceable Street Light Fittings from Pole, complete all as specified and as directed. MAKE : AXXON/ BAJAJ/ CROMPTO GREAVES/ PHILIPS
M&L Sub-main Wiring with 2-Runs of 1.5 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable and 1-Run of 1.5 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty, drawn through and including Non-metalic Rigid PVC Conduit of size 25mm dia, medium grade, ISI marked with necessary Conduit Accessories, Concealed/grouting Conduit on Brick Walls, etc. and Making Good disturbed Surfaces of Brick Walls, Ceilings, Floors, etc. in Cement Mortar 1:3 and necessary Surface Treatments so as to match with the Existing Finishes, complete all as specified and as directed.
Disconnecting the electric connection of Alternator of capacity 500 KVA DG set ,taking out the accumulator and cleaning the core assembly through air blower, heat varnishing with insulating material and refixing the same in position complete all as directed.
Supply & fixing Digital LED display three phase energy meter panel mounted, square shape, with accuracy level class-1 all as directed.
Supply, install, testing and commissioning and fire alarm control panel complying with BS EN 54 double loop panel of capacity from 99 detectors & 99 modules upto 200 detector and modules complete all as specified and as directed
Supply, install, testing and commissioning Detectors Complying with and type certified to EN-45 Addressable type smoke detector Photoelectric/Optical with base with self built intelligence as per IS:11360 complete all as specified and as directed.
Supply, install, testing and commissioning Detectors Complying with and type certified to EN-45 Addressable type Heat detector Photoelectric/Optical with base with self built intelligence as per IS:11360 complete all as specified and as directed.
Supply and laying in rigid non-metallic PVC conduit of size 20 mm(external dia) exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and as directed
SAI SERVICE
Safe Construction Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .