| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹32.2 LAccepted-AOC AURI BEHIND SAHARA INDIA PO ANPARA DISTT SONBHADRA U P | ANPARA | SONBHADRA | UTTAR PRADESH | 231225 | L-1 | Accepted-AOC As per NIT/TC | |
| 2 | Rejected-Technical PLOT NO 17 18 EWS COLONY DISTT SINGRAULI M P PIN 486889 | SINGRAULI | SINGRAULI | MADHYA PRADESH | 486889 | - | Rejected-Technical Not, evaluated as not L-1 | |
| 3 | Rejected-Technical 10 NIGAHI MODE POST NIGAHI DISTT SINGRAULI M P 486684 | SINGRAULI | SINGRAULI | MADHYA PRADESH | 486684 | - | Rejected-Technical Not, evaluated as not L-1 |
Tender Value
₹44.4 L
EMD Value
₹55,500
Closing Date
29 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Staff Officer (EM)
Office of the General Manager Khadia Area Sonbhadra 231222 (UP)
Please refer NIT for description of work
2024_NCL_298457_1
KHD/EM/E-Tender/23-24/473 DT 13.01.2024
Open Tender
Electrical and Maintenance Works
Item Rate
730 days
Khadia Project
Please refer NIT
4 documents required · 4 mandatory
₹55,500
17 Apr 2024
13 Jan 2024
30 Jan 2024
13 Jan 2024
29 Jan 2024
14 Jan 2024
13 Jan 2024 - 20 Jan 2024
Amount
Part-I :Shifting/reorientation of 33kV OHL of Khadia Project in view of railway expansion, construction of new CHP & new switching station of Bina Project. DISMANTLING AND STACKING (Sl. No. 1.01 to 1.09)
13 m to 16 m tubular pole/rail pole
Earth wire of size 7/14 SWG
ACSR wolf or equivalent size conductor
11 kV garde disc insulator with hardware
11 kV grade pin insulator with pin
22 kV grade post insulator with hardware
Stay set with stay wire, stay clamp and stay insulator
Steel materials such as MS channel bracket, angle, clamp, suport plate, pipe, nut and bolts etc. as required
Cradle guards with brackets
ERECTION/INSTALLATION (Sl. No. 2.01 to 2.19)
Survey pegging/jungle cleaning including tree branch cutting and removing it ouside the pheriphery of OHL for maintenacne or other work as required
Erection of steel tubular pole/rail pole ranging from 11 m to 16 m in brick blast/local hard stone and concreting it with cement, mine gravels and sand in ratio of 1:4:8 including excavation of pit of size 0.8 m x0.8 mx 1.6 m ( for erection of pole)
Excavation of stay pit of size 0.6m x0.6 mx1.2 m and refilling in with all kind of soil including soft rock
Concreting of stay pit with cement, mine gravels and sand in the ratio of 1:4:8
Erection of 11 kV grade disc insulator with hardware
Erection of 11 kV grade pin insulator with pin
Erection of 22 kV grade post insulator with hardwae and fixing arrangement
Erection of complete stay set including binding, tensioning with 7/10 SWG stay wire and stay insulator with back clamp on pole
Laying, stringing and tensioning of ACSR wolf or equivalent conductor
Laying, stringing and tensioning of 7/14 SWG GI earth wire
Fabrication of steel materials such as MS channel bracket, angle, clamp, supoort etc. ( steel material, welding rod and gas cylinder will be provided departmentally and other equipment such as welding machine, cutting set etc. shall be arranged by the contractor)
Erection/installation of steel materials such as MS channel, angle, clamp, support, plate, pipe, nut and bolt etc. as required
Installation/fixing of 33 kV grade lightning arrestor complete with earthing arrangement etc. ( 3 nos. in one set)
Providing of cradle guard below the OHL including fixing of brackets as per required
Opening the jumper and rejumpering ( 3 nos. in one set)
Erection of danger boards with bracket and fasteners on required height of poles and isolators as required
Installation/fixing of anticlimbing device or barbed wire by wounding around the poles at suitable height as required
Making of maintenace free earth pit with 4 inch dia GI pipe of length alteast 3 m with 50x 6m GI strip for connection and all other necessary arrangement to comply with IS 3043 (all materials such as GI pipe, earth strip/wire, nut bolt, Bentonite powder etc. shall be provided by the contractor)
Painting of tubular/rail poles with two or more coats of aluminium paint to give an even shade
Part-II : Day to day dismantling, shifting, erection etc. of 33 kV OHL as required including repairing and maintenance of existing 33 kV OHL on day to day basis as well during faults. DISMANTLING AND STACKING (Sl. No. 3.01 to 3.11)
13 m to 16 m tubular pole/rail pole
Earth wire of size 7/14 SWG
ACSR wolf or equivalent size conductor
11 kV garde disc insulator with hardware
11 kV grade pin insulator with pin
22 kV grade post insulator with hardware
Stay set with stay wire, stay clamp and stay insulator
33 kV grade Lightning arrestor
Danger board with clamp, bracket and nut bolts
Steel materials such as MS channel bracket, angle, clamp, suport plate, pipe, nut and bolts etc. as required
Cradle guards with brackets
ERECTION/INSTALLATION (Sl. No. 4.01 to 4.21)
Survey pegging/jungle cleaning including tree branch cutting and removing it ouside the pheriphery of OHL for maintenacne or other work as required
Erection of steel tubular pole/rail pole ranging from 11 m to 16 m in brick blast/local hard stone and concreting it with cement, mine gravels and sand in ratio of 1:4:8 including excavation of pit of size 0.8 m x0.8 mx 1.6 m ( for erection of pole)
Excavation of stay pit of size 0.6m x0.6 mx1.2 m and refilling in with all kind of soil including soft rock
Concreting of stay pit with cement, mine gravels and sand in the ratio of 1:4:8
Excavation of earth and refilling it with any type of soil as and when required
Concreting of old pole/stay including muffing with cement, mine gravels and local sand in the ration of 1:4:8
Erection of 11 kV grade disc insulator with hardware
Erection of 11 kV grade pin insulator with pin
Erection of 22 kV grade post insulator with hardwae and fixing arrangement
Erection of complete stay set including binding, tensioning with 7/10 SWG stay wire and stay insulator with back clamp on pole
Laying, stringing and tensioning of ACSR wolf or equivalent conductor
Laying, stringing and tensioning of 7/14 SWG GI earth wire
Fabrication of steel materials such as MS channel bracket, angle, clamp, supoort etc. ( steel material, welding rod and gas cylinder will be provided departmentally and other equipment such as welding machine, cutting set etc. shall be arranged by the contractor)
Erection/installation of steel materials such as MS channel, angle, clamp, support, plate, pipe, nut and bolt etc. as required
Installation/fixing of 33 kV grade lightning arrestor complete with earthing arrangement etc. ( 3 nos. in one set)
Providing of cradle guard below the OHL including fixing of brackets as per required
Opening the jumper and rejumpering ( 3 nos. in one set)
Erection of danger boards with bracket and fasteners on required height of poles and isolators as required
Installation/fixing of anticlimbing device or barbed wire by wounding around the poles at suitable height as required
Making of maintenace free earth pit with 4 inch dia GI pipe of length alteast 3 m with 50x 6m GI strip for connection and all other necessary arrangement to comply with IS 3043 (all materials such as GI pipe, earth strip/wire, nut bolt, Bentonite powder etc. shall be provided by the contractor)
Painting of tubular/rail poles with two or more coats of aluminium paint to give an even shade
Total impact of GST for the purpose of CTC
M/S SARCO ENGINEERING WORKS
S D SINGH CONSTRUCTION
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .