CEO JSCL
Jammu
Design, Supply, Installation, Testing, Commissioning and Operations and Maintenance of Data Centre and Disaster Recovery Centre for Integrated Command and Control Centre (ICCC) for Jammu Smart City Limited
2023_SPV_218427_1
JSCL-86/06 of 2023-24
Open Tender
Network /Communication Equipments
Item Wise
270 days
Jammu
Please refer Tender documents.
3 documents required · 3 mandatory
₹50,000
CEO Jammu Smart City Ltd
₹1.5 Cr
online
3 Oct 2023
24 Jun 2023
29 Aug 2023
24 Jun 2023
26 Aug 2023
5 Jul 2023
4 Jul 2023
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1IT Components | |||||
| 1.01 | Design, Supply, Installation, Testing, and Commissioning and O&M of Smart Racks (6 Server Racks with three 10 Tr cooling units (N+1) + 2 Network Racks with two 7 KW cooling units) with integrated Cold and Hot Aisle Containment System, Biometric Controlled Doors on both side with all the Accessories along with Modular UPS (minimum 90 KVA) in (N+1) redundancy with chassis supporting more than 100 KVA and UPS modules of minimum 30 KVA each along with required SMF Batteries for minimum 30 mins backup and all associated electrical and civil works | - | Lot | - | - |
| 1.02 | Design, Supply, Installation, Testing, and Commissioning and O&M of HCI Solution (Appliance with required software)
12 Nodes for workload + 2 Nodes for Resource Optimization manager & Centralized Management
Total 728 Cores or above
(Minimum 2*Intel Gold 2.2 GHz processor, minimum 512 GB RAM, minimum 30 TB SSD, minimum 4*3.84 TB HDD, minimum 2*25 GB connectivity ports) per node. | - | Number | - | - |
| 1.03 | Design, Supply, Installation, Testing, and Commissioning and O&M of Internal Switch for HCI with DAC cables as per requirement | - | Number | - | - |
| 1.04 | Design, Supply, Installation, Testing, and Commissioning and O&M of GPU Servers (128 GB RAM, 4.8TB 10K RPM SAS ISE,15TB SSD vSAS Read Intensive 12Gbps, 4*T4/L4 NVIDIA cards) | - | Number | - | - |
| 1.05 | Design, Supply, Installation, Testing, and Commissioning and O&M of GPU Servers (128 GB RAM, 4.8TB 10K RPM SAS ISE,15TB SSD vSAS Read Intensive 12Gbps, 3*T4/L4 NVIDIA cards) | - | Number | - | - |
| 1.06 | Design, Supply, Installation, Testing, and Commissioning and O&M of Fabric Controller | - | Number | - | - |
| 1.07 | Design, Supply, Installation, Testing, and Commissioning and O&M of Internet Router | - | Number | - | - |
| 1.08 | Design, Supply, Installation, Testing, and Commissioning and O&M of Core Router | - | Number | - | - |
| 1.09 | Design, Supply, Installation, Testing, and Commissioning and O&M of Out of Band Switch | - | Number | - | - |
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
BOQ_598368.xls
BOQ Document • 0.26 MB
123767359.pdf
Tender Document • 0.46 MB
RFPdatacentre.pdf
Tender Document • 1.93 MB
123767361.html
Tender Document • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .