Construction of Toilet at Settlement Anganwadi Centre in Ward No. 81, Hubballi-Dharwad
DMA/2025-26/BD/WORK_INDENT54918
DMA/2025-26/BD/WORK_INDENT54918
Reserved
Buildings
Electronic Documents, First(One Cover)
DMA City Corporation Hubballi-Dharawada
10 documents required · 10 mandatory
₹500
₹7,500
13 Feb 2026
13 Feb 2026
23 Feb 2026
Construction of Toilet at Settlement Anganwadi Centre in Ward No. 81, Hubballi-Dharwad
code vol 2 page 187 item 19.7.3 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-... 0.87 Cum
code vol 1 page 16 item 2.4.2 Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 ... 8.62 Cum
Code vol 1 page 111 item Addendum I As per recommendations of Technical working group, rates for formwork shall be added on percentage basis to the finished concrete item rate. For Column form works consider 70 3rd Corrigendum and 2nd... 1.66 Cum
Code vol 1 page 111 item Addendum I As per recommendations of Technical working group, rates for formwork shall be added on percentage basis to the finished concrete item rate. For Beam & Lintel form works consider 60% 3rd Corrigendum ... 2.57 Cum
Code vol 1 page 111 item Addendum I As per recommendations of Technical working group, rates for formwork shall be added on percentage basis to the finished concrete item rate. For Chejja form works consider 45% 3rd Corrigendum and 2nd... 0.55 Cum
Code vol 1 page 111 item Addendum I As per recommendations of Technical working group, rates for formwork shall be added on percentage basis to the finished concrete item rate. For Slab form works consider 50% 3rd Corrigendum and 2nd A... 3.84 Cum
Code vol 1 page 18 item 2.11a Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tyi... 1.03 Tonne
Code vol 2 page 13 item 6.2 Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour... 17.35 Cum
Code vol 2 page 41 item 8.1.1 Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, in... 22.57 Cum
Code vol 2 page 41 item 8.2.2 Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and remov... 155.66 Sqm
Code vol 2 page 46 item 8.33.1 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of... 376.75 Sqm
Code vol 2 page 48 item 8.4 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and for... 11.19 Sqm
Code vol 2 page 86 item 11.34A Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel... 60.48 Kg
Code vol 2 page 112 item 12.97.1 Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsatura... 3.78 Sqm
Code vol 2 page 112 item 12.96 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall b... 12.00 m
Code vol 2 page 60 item 9.9 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Iv... 19.52 Sqm
Code vol 6 page 2 item 1.2.1 Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab... 25.00 m
Code vol 6 page 2 item 1.3.1 SupplyingheavygaugePVCConduitPipe....dia.......mmthickwithsuitablesizebends,metaljunctionboxesadhesivepasteetc.,bygroovecuttinginthewallandfixingbybracingUorJhooksandcementplasteringuptothewallsurface... 25.00 m
Code vol 6 page 5 item 2.2.1 Point wiring using Copper wire without switch.
Supplying and wiring adopting loop system in existing PVCConduit / casing capping using 2x1.5Sqmm(Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLSmulti st... 3.00 Point
Code vol 6 page 5 item 2.2.2 Point wiring using Copper wire without switch.
Supplying and wiring adopting loop system in existing PVCConduit/ casing capping using 2x1.5Sqmm(Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLSmulti str... 3.00 Point
Code vol 6 page 5 item 2.2.3 Point wiring using Copper wire without switch.
Supplying and wiring adopting loop system in existing PVCConduit/ casing capping using 2x1.5Sqmm(Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLSmulti str... 2.00 Point
Code vol 6 page 5 item 2.3.2 Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 2.3.2)1.5 mm2PWD,Elc... 50.00 Point
Code vol 6 page 5 item 2.3.3 Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 2.3.3)2.5 mm2PWD,Elc... 100.00 Point
Code vol 6 page 8 item 3.4.1 Supplying and flush mounting powder coated / galvanizedmetal box suitable for mounting modular switch plates. Thebox should be firmly flush mounted after due groovecutting in Brick/Stone/C.C wall ... 3.00 Each
Code vol 6 page 8 item 3.4.5 Supplying and flush mounting powder coated / galvanizedmetal box suitable for mounting modular switch plates. Thebox should be firmly flush mounted after due groovecutting in Brick/Stone/C.C wall ... 1.00 Each
Code vol 6 page 8 item 3.5.1 Supplying and fixing superior quality modular switchmounting polycarbonate plate with necessary supportingback plate with required nos. of machine screws, bolts nutsetc., complete on the existing meta... 3.00 Each
Code vol 6 page 8 item 3.5.5 Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supportingback plate with required nos. of machine screws,boltsnutsetc.completeontheexistingmetal/PVCbo... 1.00 Each
Code vol 6 page 9 item 3.6.1 Supplying and fixing of modular switch & connectedaccessories on existing modular switch plate as per IS 3854and IS 1293. 3.6.1)6Amps one way switchPWD,Elct, SR 2023-24 Page No.9 IItem code 3.6.1 8.00 Each
Code vol 6 page 9 item 3.6.2 Supplying and fixing of modular switch & connectedaccessories on existing modular switch plate as per IS 3854and IS 1293. 3.6.12)6Amps two way switchPWD,Elct, SR 2023-24 Page No.9 IItem code 3.6.... 2.00 Each
Code vol 6 page 10 item 3.14.7 Supplying and fixing/replacing of 6/16/32Amps electricalaccessories on existing switch board.3.14.7) 6 Amps batten holderPWD,ElctSR 2023-24 Page No. 10 IItem code 3.14.7 4.00 No
Code vol 6 page 9 item 3.6.3 Supplying and fixing of modular switch & connectedaccessories on existing modular switch plate as per IS 3854and IS 1293. 3.6.3)6Amps 3way socketPWD,Elct, SR 2023-24 Page No.9 IItem code 3.6.3 1.00 Each
Code vol 6 page 43 item 11.3.2 Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. PowerInput: 220-240V @ 50/60Hz & ... 2.00 Each
Code vol 6 page 56 item 13.7.1 Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling /rafters / girders using 23/0.0076” twin twisted PVC insulatedwires,... 2.00 Each
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
54918 tech.pdf
Technical Information / Worksheet • 2.47 MB
kw-1 indent 54918.doc
Tender Document • 0.93 MB
government notification bc loc letter to be issue.pdf
Others - Government Notification • 1.75 MB
54918 admin.pdf
Others - administrative approval copy • 1.84 MB
All Formats which are to be attached.pdf
Others - All format • 0.29 MB
GENERAL AND TECHNICAL CONDITIONS.docx
Others - genral conditions • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].