Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.1 LAccepted-AOC B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹48.6 L+₹7.4 L (18.0%)Rejected-AOC | L2 | Rejected-AOC Not Accepted | |
| 3 | L3₹48.7 L+₹7.6 L (18.4%)Rejected-AOC T 16 1 SHETTY HOTEL OLD NAVY NAGAR COLABA MUMBAI 400005 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | L3 | Rejected-AOC Not Accepted | |
| 4 | L4₹53.3 L+₹12.1 L (29.4%)Rejected-AOC | L4 | Rejected-AOC Not Accepted |
Tender Value
₹45 L
EMD Value
₹94,000
Closing Date
5 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer North Mumbai
Garrison Engineer North Mumbai Military Engineer Services Santacruz East, Mumbai 400029
CERTAIN REPAIRS TO ROOF AND COLUMNS AT BLDG NO. NP-03 (GROUP-I) STORAGE SHED AT AFMSD KANDIVALI UNDER GE NORTH MUMBAI
2022_MES_516826_1
8967/E8
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer North Mumbai
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer North Mumbai
₹94,000
Yes
13 May 2022
6 Apr 2022
7 May 2022
6 Apr 2022
5 May 2022
21 Apr 2022
7 Apr 2022 - 20 Apr 2022
60 days
Amount
Dismantling Asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings including ridges all as specified and as directed
Supply and fix Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick as per approved profile of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws or L type or J type or cranked hook bolts or as per manufacture instruction complete all as specified and as directed by Engineer-in-Charge Make: JINDAL / INDALCO / HINDALCO / ASSOCIATED Profiles and Aluminium Ltd / ESSAR colour coated sheets
Supply and fix Pre- painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick as per approved profile of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws or L type or J type or cranked hook bolts or as per manufacture instruction complete all as specified and as directed by Engineer-in-Charge. Make: JINDAL / INDALCO / HINDALCO / ASSOCIATED Profiles and Aluminium Ltd / ESSAR colour coated sheets
Demolition of brick work masonry built in cement mortar or cement lime mortar and removing of debris outside MD land complete all as specified and as directed by Engineer-in-Charge.
Material and labour for brick work with sub class "B" bricks straight or curved on plan exceeding 6 metre mean radius with old size bricks and built in cement mortar (1:6) complete all as specified and as directed by Engineer-in-Charge.
Taking down cement plaster of any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc and removing debris outside MD land complete all as specified and as directed by Engineer-in-Charge
Material and labour for rendering 10mm thick on internal wall surfaces using factory manufactured pre mix/ready mix plaster of 'Roofit Mix' of M/s Premier Floor to Roof Materials Pvt Ltd/'Easy plast' of M/s Walplast Products Pvt Ltd/'Readiplast' of M/s Ultratech Cement Ltd' / Sound last PMC-1 of M/s Sound buildcare Pvt Ltd/or other approved equivalent make, having minimum composition of C:S : 1:6 using fully treated dry, well graded natural sand confirming to IS 383 suitable for plastering, having low rebound properties, low water demand for curing properties mechanical mixing with water in a metallic tray only to make good consistency as per the specification of the Manufacturer and applied over masonry and concrete surfaces and finishing with sagol finish not less than 1mm thick, including cleaning the surfaces, curing etc complete all as specified & directed by Engineer-in-Charge.
Material and labour for rendering 15 mm thick cement plaster in CM 1:4, two coats using factory manufactured pre mix/ready mix of 'Roofit Mix' of M/s Premier Floor to Roof Materials pvt ltd/ 'Easy plast' of M/s Walplast Products pvt.ltd/ 'Readiplast' of M/s Ultratech Cement Ltd/'Soundplast PMC-1' of M/s Sound buildcare pvt Ltd/ or other approved equivalent make, having minimum composition of C:S : 1:4 using fully treated dry, well graded natural sand conforming to IS 383 suitable for external plastering, having low rebound properties, low water demand for curing properties, mechanical mixing with water in a metallic tray only to make good consistency as per the specification of the Manufacturer and applied over exterior masonry and concrete surfaces with base coat of 10 mm thick and finishing coat of 5 mm thick final rendering with water proofing compound @ 3% by weight of cement or as per manufacturer's instructions, including using richer mix for making corners if necessary, at all floors and level, including making grooves of existing size wherever required, including cleaning the surfaces, curing including provide of 150mm chicken wire mesh fixed with nails at the junction of RCC columns/walls/ beams/ lintels and brick masonry at external faces before plastering including scaffolding at any height and all safety materials required for execute work etc. complete all as per specifications & as directed by the Engineer-in-Charge.
Supply only water proofing compound, ISI marked complete all as specified and as directed by Engineer-in-Charge. Make : Pidilite Industries Ltd, Taloja /Super Aquacem (India) Ltd /FOSROC/Siko/Dr Fixit
Material and labour for new plastered surface of wall and applying two coats of distemper oil emulsion over a coat of priming plastered with alkali resistance priming paint complete all as specified and as directed by Engineer-in-Charge. Make: M/s SHALIMAR / M/s BERGER / M/s NEROLAC /M/s ASIAN (Tractor Brand)
Material and labour for applying 1.5mm thick wall care putty over surfaces complete all as specified and directed by Engineer-in-Charge. Make : Birla cement/JK white/ Golden Mohar
Material and labour for applying two coats of cement based paint on new wall surface complete all as specified and as directed by Engineer-in-Charge. Make : Snowcem/Duracem/Aquacem/Berger/Shalimar
Demolition of reinforced cement concrete of any description in any position including necessary scaffolding arrangement (reinforcement cut as required to facitate demolition) and removing concrete debris and depositing outside MD land all as specified and as directed by Engineer-in-Charge. Note : Reinforcement obtained from this item shall be handed over to contractor on account of sch of credit .
Material and labour for surface preparation of structural part by gentle chipping by manually to make the surface rough and thoroughly cleaned with air as per standard practice and directions of Engineer-in-charge, (including removal of external plaster, wherever exists) costs inclusive of transportation, labour, conveying debris away from the site (max 50m) tools and tackles, lead and lift etc, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix mild steel TMT bars, 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge. Note: Cutting of rusted reinforcement & welding shall be inclusive in this item of work
Supply and fix mild steel TMT bars, 8 to 10mm dia in stirrups, spacers and binder cut to length bent to shape required inch cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge. Note: Cutting of rusted reinforcement & welding shall be inclusive in this item of work
Supply and fix MS/TS dowel pins/staple/shear pins including drilling holes in concrete and providing labour and but excludes the materials for grouting the pins.etc complete all as specified and as directed by Engineer-in-Charge.
Repairing of excessively damaged concrete portion of column, beam, lintel etc by using superfluid dual shrinkage compacted and providing, casting with micro concrete of grade M-30 at all levels with all leads and lift as directed including mixing, laying, levelling, finishing including curing and formwork of steel or marine ply complete all as specified and directed by Engineer-in-Charge. Make: Fosroc / SIKA / BASF / Krishna Conchem or equivalent approved.
Material and labour for providing and applying rust cleaner (Re-backler solution) to exposed corroded reinforcement @ 0.20 Litre/Sqm or approved make over prepared reinforcement, including removing concrete all around reinforcement including from behind the reinforcing bars by manual methods such as hammering the rebar, using wire brushes, chiselling, etc. and applying rust removing solution of approved make with cotton waste swab to reinforcements etc complete as directed by Engineer-In-Charge. Make- Dr FIXIT/ FOSROC/ Krishna Conchem/BASF/Sika
Material and labour for providing and applying two coats of anticorrosive epoxy phenolic rebar protective system IPNet RB or equivalent of approved make and quality comprises of resin and hardener mixed in equal proportion by volume with minimum 9-10 hours between the coats, sprinkling dry sand when 2nd coat is tacky so as to provide rough finish and ensuring air curing of minimum 10 hours after the top coat before any subsequent treatment etc. including scaffolding etc complete all as specified and as directed by Engineer-in-Charge. Note: (a) New Reinforcement shall be measured and paid separately under respective item. (b) Cost of welding deemed to be inclusive in this item of work. Make- Dr FIXIT/ FOSROC/ Krishna Conchem/BASF/Sika as approved by GE
Material and labour for providing and applying a priming cum bonding coat of two component Epoxide Resin conforms to ASTM-C-882-91 of approved make and quality to clean and sound concrete area by brush or any other established method by mixing Base and curing agent in 2:1 proportion by weight for joining old and new concrete as per technical specifications of manufacturer. Work shall be carried out as per the manufacturers specifications & certificate on this account shall be taken from consultant and as approved by Engineer-in-charge Make- Dr FIXIT/ FOSROC/ Krishna Conchem/BASF/Sika as approved by GE Note for item Nos 15 to 21:- (i) The work shall be carried out by authorised applicator only. (ii) Defect liability for these items shall be 5 years from certified date of completion. (iii) Amount of 5% of these items shall be retained during RAR and FB. This amount shall be released after successful completion of Defects liability period as mentioned above. (iv) Non destructive testing shall be got carried out through IIT / NIT / College of Engineering Pune to decide fulfilment of fitness criteria of structure after completion of work. (v) The test shall be carried out at each discrete location or locations decided by GE or testing authority. (vi)The cost of testing shall be deemed to be included in the rate quoted by the contractor. Completion shall be issued by GE after only getting structural stability certificate of each respective building from testing authority.
Material and labour for providing and laying 20 mm thick POLYMER MODIFIED MORTER over identified R.C.C. members in One layer in proportion of 1:5:15 by weight of polymer of approved make, cement and filler material of approved make, blended to a required consistency and applying and finishing by floating, curing after initial setting time, including providing and inserting 10 mm mild steel shear key bars (minimum 3 nos per sqm), wherever required, bonding slurry, etc complete all as specified and as directed by Engineer-in-Charge. Make- Dr FIXIT/ FOSROC/ Krishna Conchem/BASF/Sika as approved by GE
Dismantling of wall and ceiling boards(fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness including cover fillets all as specified and as directed
Supply and fix false ceiling of GI powder coated ceiling exposed grid system 'UNILOCK' comprising main runner 38 x 24 x 0.35mm, cross Tee 28 x 24 x 0.35mm and angle alongwith wall shall be in size 24 x 24 x 0.40mm including 3mm dia GI suspended fixed to ceiling at every 1200mm c/c on both direction and including mineral fibre acoustic ceiling board USG of size 600 x 600 x 15mm all as per manufacturer's instruction etc complete all as specified and as directed by Engineer-in-Charge. Make : Anchor Ceiling Tiles / Arm Strong / Gypboard / Bison Panel / Lagyp
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed by Engineer-in-Charge.
Material and labour for rolled mild steel sections as in roof trusses (framed), trussed, purlins, crane gantries, rails, and fastenings and heavy bracket framing, (beam, tee, angle, channels or flat sections) including notching, drilling, fitting, riveting and / or welding or connecting with bolts and nuts (including rivets or bolts and nuts) conforming to Fe 410 W Gde E- 250, Quality B complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparation of new steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of zinc chrome primer with necessary scaffolding / shuttering etc complete all as specified and as directed. Make : Asian paints/ Nerolac paints/Berger paints/ Shalimar paints/ Dulux
Material and labour for preparation of old steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of zinc chrome primer with necessary scaffolding / shuttering etc complete all as specified and as directed. Make : Asian paints/ Nerolac paints/Berger paints/ Shalimar paints/ Dulux
Material and labour for 1mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and as directed by Engineer-in-Charge.
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc., removing materials out side MD land in case of Credit and making good disturbed surfaces of walls, floors, etc., all as specified and as directed.
Material and labour for Point wiring for complete with PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor conforming to IS-694, 1.5sqmm (nominal area) drawn through and including non metallic PVC casing / capping (not less than 20mm wide) (ISI marked) and accessories on surface of wall/roof with sunken type pressed steel/welded terminal boxes made out of 1.6mm mild steel sheet, 3mm thick laminated sheet cover for mounting of switches, socket outlets, regulators etc., including provision of PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor 1.5sqmm as earth continuity conductor and connecting to common earth dolly complete all as specified and as directed by Engineer-in-Charge.
All as per iteam No 31 here in before One 5 pin 5/6 Amps switch socket combination point on independent board
All as per iteam No 31 here in before One 5 pin 5/6 Amps switch socket combination point on the same board with other switches controlled by one switch.
All as per item No 31 described here in before but for 5 pin 15/16 Amps switch socket combination on independent board with 2.5sqmm copper cable and provision of 2.5sqmm PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor for earth continuity conductor connected to common earth dolly connecting up to fittings complete.
Material and labour for Point wiring for complete with PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor conforming to IS-694, 1.5sqmm (nominal area) drawn through and including non metallic PVC conduit 20mm dia (ISI marked) and accessories laid on surface of wall/roof with sunken type pressed steel/welded terminal boxes made out of 1.6mm mild steel sheet, 3mm thick laminated sheet cover for mounting of switches, socket outlets, regulators etc., including provision of PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor 1.5sqmm as earth continuity conductor and connecting to common earth dolly complete all as specified and as directed by Engineer-in-Charge.
All as per item No 35 described here in before One 5 pin 5/6 Amps switch socket combination point on independent board
All as per item No 35 described here in before One 5 pin 5/6 Amps switch socket combination point on the same board with other switches controlled by one switch.
All as per item No 35 described here in before but for 3 pin 15/16 Amps switch socket combination on independent board with 2.5sqmm copper cable and provision of 2.5sqmm PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor for earth continuity conductor connected to common earth dolly connecting up to fittings complete.
Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by Engineer-in-Charge. Make:Havells Cat Part LHEXACP7UN1W020 or equivalent of Philips / Bajaj / Crompton greaves / Wipro
Supply and fixing in repairs LED tube rod fitting 1x 20W, 220V, complete all as specified and as directed by Engineer-in-Charge. Make:Havells Cat Part LHLDDCXCML8Q020 or equivalent of Philips / Bajaj / Crompton greaves / Wipro
Supply and fixing round shape 20 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-Charge. Make:Havells Cat Part LHEBLEP5IN1W020 for round and LHEBHEP7IZ1W018 for square or equivalent of Philips / Bajaj / Crompton greaves / Wipro
Supply and fix Switch Piano, flush type, single pole, one way, 5/6 Amps, 240 volts, ISI marked complete all as specified and as directed by Engineer-in-Charge. Make: Anchor / Legrand / L&T
Supply and fix Ceiling rose, surface type Bakelite, three terminal 65x32mm, ISI marked complete all as specified and as directed by Engineer-in-Charge. Make: Anchor / Legrand / L&T
Supply and fix switch socket outlet, combination 2 in 1, 5 Pin, 6Amps, flush type, universal ISI marked complete all as specified and as directed by Engineer-in-Charge. Make: Anchor / Legrand / L&T
Supply and fix switch socket outlet, combination 5 in 1, 5 Pin, 6/16Amps, flush type, universal ISI marked complete all as specified and as directed by Engineer-in-Charge. Make: Anchor / Legrand / L&T
Supply and fix stepped type electronic fan regulator on existing phenolic laminated sheet etc complete all as specified and as directed by Engineer-in-Charge. Make: Anchor / Legrand / L&T
Supply and fix in repairs MCB SPN, 6 Amps to 32 Amps, 240 volts,10 KA complete all as specified and as directed by Engineer-in-Charge. Make : Legrand / L&T / Havells / ABB / Siemens / Schneider
Material and labour for Earthing complete with Galvanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of earth the plate not less than 1.5 metres below normal ground level, connected to and including galvanised earth lead wire 4 mm dia, 7.5m long, by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel with provision of charcoal & common salt packed upto minimum 150 mm all around the earth plate, and protected by 15 mm bore light grade galvanised iron pipe and connected to control board / panel / equipment complete all as shown in electrical plate No.3 of MES schedule Part I with PCC pit in PCC 1:2:4 type B1 using 20 mm graded stone aggregate, MS angle iron frame of size 50mm x 50mm x 5mm, cast iron cover with locking arrangements, GI 20 mm bore medium grade pipe and CI funnel with wire mesh for watering arrangement including necessary excavaion and earth work in any type of soil/strata & testing complete all as specified and as directed by Engineer-in-Charge.
K Vani Construction
Shetty Construction Co
SHANTI CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .