Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.1 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹43.5 L+₹7.6 L (21.2%)Rejected-AOC | L2 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 3 | L3₹44.0 L+₹8.1 L (22.4%)Rejected-AOC | L3 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 4 | L4₹45.4 L+₹9.5 L (26.4%)Rejected-AOC VILL PO KUMARHATTI DIST SOLAN HP | SOLAN | SOLAN | HIMACHAL PRADESH | L4 | Rejected-AOC OTHER THAN LOWEST BIDDER |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
28 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
RAHUL MEENA IDSE EE GARRISON ENGINEER
MES OFFICE GE KASAULI DISTT SOLAN
REPAIR TO CGI SHEET, CEILING, PANNELING, MASONARY AND OTHER WORKS IN OTM AND MD ACCN AT DAGSHAI UNDER GE KASAULI
2022_MES_549627_1
GEK-50/2022-23
Open Tender
Civil Works
Item Rate
180 days
DAGSHAI UNDER GE KASAULI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE KASAULI
₹80,000
Yes
18 Oct 2022
2 Sept 2022
5 Oct 2022
2 Sept 2022
28 Sept 2022
16 Sept 2022
Amount
Schedule 'A' Section - I
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed by the Engineer-in-Charge.
Dismantling wall and ceiling board (fibre, pulp, insulation, etc) or insulationboards/kitchen cupboard , any thickness etc. including cover fillets complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frames n.exc. 1.5 Sqm each but without taking off shutters from the frames complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frames exc. 1.5 Sqm and n.exc 4 sqm each but without taking off shutters from the frames complete all as specified and directed by Engineer-in-Charge.
Demolition of brick work or stone masonary built in cement mortar including quions, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles and disposing off the rubbish materials where complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) and disposing off the rubbish materials where complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description any position not otherwise provided complete all as specified.
Dismantling timber scantlings 40 sqcm and under in section, in any position framed / Unframed work complete all as specified by the Engr-in-Charge.
Dismantling unframed timber scantlings 40 sq. cm and over in section, in any position complete all as specified.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) up to a height 12 mtr including necessary scaffolding all as specified and as directed.
M & L for taking down cement or lime plaster of any description on brick or stone walls etc including ranking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
S & F for second class hard-wood(Hollock), timber fixed and clean sawn, in scantlings complete all as specified.
S & F for 0.63mm Galvanised, Corrugated Mild steel sheeting with two corrugations side lap, fixed with L-type or J-type or cranked hook bolts in lieu of screws and bend to curve all as directed.
S & F plain, galvanised, 0.63mm thick, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashing (length and girth as fixed) complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated/semi corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550MPA as in roof covering/cladding to wall, fixed with self tapping screws as specified.
S&F pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/clading to wall, fixed with self tapping screws as specified.
S&F RMP sheeting 1.5 mm thick with 1.5 corrugation side lap fixed with coach screw and PVC washer in roof, wall etc complete all as specified and directed by Engineer-in-Charge.
M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc all as specified and as directed.
Material and Labour Framed work such as grills, gratings,railing etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified.
Material and Labour for Welded steel wire fabric n.exc 4 Kg/Sqm supplied and fixed complete to wood or steel members complete all as specified.
S &F Powder Coated Anodised aluminium frame for doors, windows, parttions , ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified.
S &F powder coated aluminium window and ventilator shutters, side hung type without sash , aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws anodised aluminium fittings such as peg stays 150 mm long (1 no) hinges type B-1 100 m long(2 Nos) suitable handle(1 Nos). and tower bolt 150 mm (2 No)in each shutter complete up to a height of 10 mtr including necessary scaffolding all as specified and as directed .
S&F in repair 9mm thick pre-laminated particle board interior grade, both side lamination of approved colour and pattern fixed to wooden / aluminium frame work as in door/cupboard shutters all as specified.
S &F Anodised aluminum grill of approved pattern / design with approved standard section and fixed to the existing window frame with CP brass / stanless steel screws @200 mm centre to centre including cutting the grill to proper opening size fpor fixing and operation og handles and fixing approved anodiesd aluminium standard section around the opening all complete all as specified and all as dircteded.
S &F for Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples all as specified and directed.
S&L for sheet glass ordinary quality 4.80mm thick in aluminium windows of area of each pane exc 0.50 Sqm complete all as specificed and directed by Engr-in-Charge.
S&LFigured glass, pin head type 5.00 mm thick in aluminium windows of area of each pane exc 0.50 Sqm complete all as specificed and directed by Engr-in-Charge.
M&L for brick work with sub class `B` bricks, in straight or curved on plan in any radius , built in CM 1:6 complete all as specified and directed.
M & L for Rendering 15mm thick in cement plaster 1:4 on fair faces of brick work or concrete surfaces incl finishing surface without using extra cement complete all as specified and directed.
M & L for Rendering 15mm thick in cement plaster 1:6 on fair faces of brick work or concrete surfaces/stone work incl finishing surface w/o using extra cement complete all as specified and as directed by the Engineer-in-Charge.
S&F GI metal suspended ceiling system, GI lay in plain of 600x600x0.5mm (TEGULAR) edge tiles in globel white colour to be laid on strong 24mm Tee section flanges colour white having roatary stiching on the main runner with web height of 38mm complete all as specified and directed Note- (i) To comprise main runner spaced at 1200mm centres securely fixed to the structural soffits at 1200mm maximum centre. The first/last suspension system at the end of each main runner should not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200mmx600mm module. Cut cross tees longer than 600mm required independent support. 600mmx600mm module to be found by fittings 600mm long flush fitting cross tees centrally between the 1200mm cross tees. Perimeter trime to be wall angles of size 3000mm x 19mm x 19mm secured to walls at 450mm maximum centres. (ii) The HCL sleeve anchor fastnor of thread size 6.50mm x 25/5 with soffits cleat made of galvanised steel of size 27x37x25x1.6mm and level clip in dimensions of 85x30x0.8mm with 4mm GI wire complete all as specified and as directed.
M & L for 6 mmPlywood, grade BWR, type BB, fixed with screws to timber frame complete all as specified and directed by Engineer-in-Charge.
Material and Labour for 2nd class hard wood (Hollock) Plain fillets Exc 13 & n. exc 25 sq.cm square, rectangular or triangular in section, clean sawn, secured with nails or brads,complete all as specified.
Material and Labour for 2nd class hard wood (Hollock) Plain fillets Exc6 & n. exc 13 sq.cm square, rectangular or triangular in section, clean sawn, secured with nails or brads,complete all as specified.
S&F PVC rain water half round gutter pipe of size 110 mm dia fixed with clamp up to a height 12 mtr including necessary scaffolding all as specified and as directed .
S&F PVC rain water gutter drop elbow for 110 mm dia pipe fixed to PVC pipe all as specified and as directed.
S & F in repair 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to rain water gutter pipe and fixed to wall with clamp up to height lamp up to a height 12 mtr including necessary scaffolding all as specified and as directed .
S & F in repair 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to rain water gutter pipe and fixed to wall with clamp up to height lamp up to a height 12 mtr including necessary scaffolding all as specified and as directed .
S&F PVC(SWR) bend 110mm dia bore complete all as specified and directed by Engr-in-Charge.
S&F PVC(SWR) bend 75mm dia bore plain in cement concrete type B-1(1:2:4) and jointing to waste pipe complete including taking out old unserviceable floor trap all as specified and directed .
M&L for MS Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required all as specified And as dircted.
Preparation of newly plastered surfaces of wall & applying two coat of cement based paint over a coat of primer complete all as specified and directed.
Preparation of new surfaces applying two coats of oil bound distemper over one coat of primer on walls all as specified and directed by the Engr-in-Charge.
M&L for preparation of new steel surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer all as specified & directed complete all as specified and directed by Engr-in-Charge.
M&L for complete removal existing treatment of steel surfaces and applying two coat of synthetic enamel paint over a coat of primer complete all as specified and directed.
M & L for two coats of synthetic enamel paint over coat of pink primer on new wooden surfaces of any description not otherwise described over 10 Cm width or girth including preparation of surfaces complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of old painted NTP/CGI/PGI or other steel roof surfaces, eaves and gutters etc exc 10 cm width or girth and applying one coat of synthetic enamel paint of any tint as approved complete all as specified.
M&L for complete removal existing treatment on old painted NTP/CGI/PGI or other steel roof surfaces, eaves and gutters etc exc 10 cm width or girth and applying two coat of synthetic enamel paint of any tint as approved over a coat of primer all as complete all as specified.
Taking up or down steel tubing and connections including cleaning for refixing or removal to store upto 15mm bore complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing and connections including cleaning for refixing or removal to store upto 20 mm bore complete all as specified and directed by Engineer-in-Charge.
15mm bore GI tubing (medium grade) with all fittings and fixed complete to walls and ceiling or laid in floors/roofs etc complete all as specified.
20mm bore GI tubing (medium grade) with all fittings and fixed complete to walls and ceiling or laid in floors/roofs.etc complete all as specified.
M & L for 500 Litres rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including PTMT float valve of 15 mm dia and taking down old unserviceble PVC water tank all as specified in SSR Part-I completed and as directed by the Engr-in-Charge
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) all as specified and as directed.
Preparation of surface of wood and wood based material, new or old of any description and girth, not otherwise described and treated with creosote complete all as specified & directed.
Excavating in post holes (or similar holes) each not exc 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25cm, watering, and removing surplus soil to a distance n.exc 50 m and making good surface in hard/ dense soil etc complete all as specified.
Dismantling posts or struts (Wood, steel or RCC) any section including taking out embedded portion in concrete, brick work, masonary etc, and making good disturbed ground complete all as specified and directed.
Amount of credit of Rs. 176361.00 for retrived old material as mentioned in Schedule 'A' section-II of tender document in pdf form, will be deducted offline while acceptence of tender.
Varindera And Varindera Construction
P.G.INFRASTRUCTURE
Vishal Builder
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .