Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.1 LAccepted-AOC | ₹7.1 L | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹7.2 L+₹8,549 (1.20%)Rejected-Finance | ₹7.2 L+₹8,549 (1.20%) | L2 | Rejected-Finance Being Not Lowest |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
31 Aug 2020, 6:00 pmClosed
SHRI PRABHAT KUMAR SINGH, AGE I AF MANAURI
AGE (I) AF Manauri ALLAHABAD- 212212
PROVISION OF BATTERY ROOM AND IMPROVEMENT TO FALSE CEILING AT 24 ED AF STATION MANAURI
2020_MES_362790_1
8827/E8
Open Tender
Civil Works
Item Rate
182 days
Manauri, Allahabad
Class E, Cat a (i)
7 documents required · 7 mandatory
₹500
AGE (I) AF Manauri
₹16,000
Yes
30 Sept 2020
3 Aug 2020
2 Sept 2020
3 Aug 2020
31 Aug 2020
18 Aug 2020
Amount
Surface excavation n.exc 30cm deep and averaging 15 cm deep and getting out in soft/loose soil etc
Excavating in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for wall foundation etc or for manholes etc not exceeding 10 Sqm area on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil.
Returning filling in foundation/trenches including spreading leveling, watering and well ramming in layers not exceeding 25cm thick complete.
Earth filling under floor in layers not exceeding 25cm thick & well ramming and watering as required.
Removing excavated surplus soil n. exc 50 metre and deposited where directed at a level n.exc 1.5 metre above the starting point complete.
M&L for hard core of broken stone or boulders guage not exceeding 63mm, deposited, spread and levelling in layers not exceeding 15 cm thick, watered and rammed to true surface
M&L for provide Cement concrete 1:4:8 type D-2 (Using 40mm graded crushed stone aggregate) in foundations, filling and mass concrete
M&L for RCC M-25 (design mix) using graded crushed stone aggregate in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, basement slabs, under-reamed piles and mass concrete etc. Note :- Reinforcement and formwork shall be measured and paid for separately under respective items of this schedule 'A'.
M&L for RCC M-25 (design mix) using graded crushed stone aggregate as in column, pillar and struts etc. Note :- Reinforcement and form work shall be measured and paid for separately under respective items of this schedule 'A'.
M&L for RCC M-25 (design mix) using graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span. Note :- Reinforcement and form work shall be measured as paid for separately under repective items of this schedule.
M&L for provide PCC (1:2:4) type B-0 (using 10/12.5mm graded crushed stone aggregate) as in hold fast of grill work & for preessed steel door frame including necessary form work.
M&L for provide PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in coping, cills etc including necessary form work.
M&L for brick work with fly ash bricks (old size) straight or curved on plan exceeding 6 metre mean radius, built in cement and sand mortar (1:6) complete
M&L for provide 40 mm thick damp proof course 1:2:4 using 12.5mm graded crushed stone agreegate mixed with liquid water proofing compound as per manufacturers instructions including necessary form work complete as directed. Note:- liquid water proofing compound shall be measured & Paid separately under respective item of this schedule as supply only.
Supply only integral water proofing compound.
Form work for flat rough finished surfaces of sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work, vertical or to batter.
Form work to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work not exceeding 200mm thick (horizontal or slooping) flat rough finished surfaces of concrete complete.
Form work to sides and sofit of beam, lintelover 1.5metre span including supports, rough finishing to surface of concrete
Form work for flat rough finished surfaces of concrete to column, pillar, struts etc.
Form work to edge of concrete flats, roof/ shelves not exceeding 200mm wide, sides of bands in walls and similar work exceeding 100mm but not exceeding 200mm wide, rough finished surface of concrete.
S&F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides etc including teak wood beading on all edges. Note :- Thickness of beading for hinge sides shall be 25 mm and on other three edges 6mm thick.
S & F 30 mm thick 2nd class hard wood glazed and skelton door shutter, open rebated and prepared to receive glass, gauze, etc (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for scuring glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, section 8, clause 8.24 (a), supplied and fitted to chowkats complete all as specified. Note :- (i) Quoted rates deem to be included cost of wooden beading to fix glass panes/ wire cloth. (ii) Glass panes/ wire cloth shall be measured and paid for separately and supply only under respective item of this schedule.
S&F extruded aluminium alloy handles anodised 125mm long fabricated type complete all as specified & directed.
Supply & Fixed 150mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified & directed by Engineer-in-Charge.
S&F sliding door bolts clip type aluminium anodised with hasp & staple type, including bright bolts not less than 12mm dia with and including minimum 6 bolts & nuts, four on bolt plate and two on staple plate; length of bolts 300 mm long complete all as specified & directed by Engineer-in-Charge.
S&F mild steel cold rolled butt hinges 100 mm medium weight fixed with screws to PVC or wooden frames or with welding in steel frame complete as specified & directed.
S&F mild steel framed work such as grills, grating etc with ends of bars shoulded, framed guard bars and similar work conforming to Fe-290 Gde E-165 fixed to frame.
S&F mild steel flat iron as in hold fasts for grill work etc confirming to Fe-290 Gde E-165.
S&F for 125x60mm size pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed Note:- Filling hollow of frame with plain cement concrete and/or with cement mortar shall be measured and paid separately.
S & F Steel windows with side hung shutters including projecting type hinge with steel handle and steel peg stay complete with glazing bars, dovetailed or welded joints complete as specified & directed by Engineer-in-Charge.
S & F Steel ventilator with top hung shutters including hinge with steel handle and steel peg stay complete as specified & directed by Engineer-in-Charge.
Supply only sheet glass 3 mm thick ordinary quality in Square or rectangular in shape not exceeding 0.5 Sqm each pane and glazing with oil putty or steel pins complete all as specified & directed by Engineer-in-Charge.
Supply only galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm complete as specified & directed by Engineer-in-Charge.
S&F for steel reinforcement mild steel TMT bars, 10mm dia and over cut to length, bent to shape required, including cranking, bending, spiralling for hooping for columns, hooking and binding with and including mild steel wire (annealed) not less than 0.9mm dia.
S&F for steel reinforcement mild steel TMT bars, 8mm dia, cut to length bent to shape required crankng, hooking end and binding with and including mild steel wire (annealed) not lkess than 0.90 mm dia.
S&F for steel reinforcement mild steel TMT bars, of 8mm, 10mm dia as in stirrups, spacers and binders cut to length bent to shape required cranking, hooking end and binding with and including mild steel wire (annealed) not less than 0.90mm dia.
Supply & Fixed 300mm mild steel, ordinary rat tail rod double action pattern springs including roller and roller plate complete fixed to steel or wooden door frame including necessary welding cutting opening of wall for fixing brackets complete as specified & directed by Engineer-in-Charge.
Supply & Fixed floor door stopper aluminium alloy body and toungue anodised with rubber shoes at bottom fixed with screw to body and fixed to door shutters overall length of cover plate 140 mm complete as directed by Engineer-in-Charge.
M&L for PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate , as in roof padding (approx avg 50 mm thick or more) etc complete all as specified and directed by Engr-in-charge.
M&L for cleaning the roof surface (padding) from dust/dirt and provide water proofing treatment using APP modified polymeric membrane complete with as per following operations and all as specified in particular specifications. (i) 10 mm thick plaster in CM 1:3 mixed with polimer based liquied water proofing compound. (ii) Appling bituminous based primer conforming to IS:3384 @ 0.3 Kg per Sqm over plaster. (iii) Laying APP modified polymeric membrane and bonded to the sub-strata by heat process, over laps shall be sealed/ fused by flame torch as per manufacturer's instructions. (iv) Appling bituminous based aluminum paint @ 0.2 Kg per Sqm in two coats over APP modified polymeric membrane. Note:- (i) Water proofing treatment shall be carried out through authorized applicators. (ii) The work shall be strictly as per manufacturer’s instructions. (iii) Rate shall be deem to be include cost of polimer based liquied water proofing compound under this item.
M&L for 75mm thick cement concrete type D-2, 1:4:8 (40mm graded stone aggregate) as sub base to floor over rammed earth
M&L for 75 mm thick PCC (1:3:6) type C-2 , using 40 mm graded crushed stone aggregate as in plinth protection laid in panel not exceeding 3 metre surface shall be finished even and fair.
50mm thick plain cement concrete, type B-1, 1:2:4 (using 20mm graded crushed stone aggregate, laid in bays, as in floor surface finished even a smooth with using extra cement. Note :- Glass dividing strip shall be measured and paid for separetely under respective item of this schedule as supply only.
Supply only 3mm thick glass dividing strips, 38mm width etc complete.
M&L for 15mm thick rendering in cement and sand mortar (1:6) on fair faces of brick work surfaces finished even and fair without using extra cement.
M&L for 15mm thick rendering in cement and sand mortar (1:4) on fair faces of brick work, surfaces finished even and fair without using extra cement.
M&L for 10mm thick rendering in cement and sand mortar (1:3) on ceiling surface finished even and smooth without using extra cement
M&L for preparing new plastered surfaces of ceiling and applying three coat of white wash on ceiling
M&L for preparing of new plastered surface of wall and apply two coat of cement paint over a coat of primer.
M&L for preparing of new plastered surface of wall and applying two coat of oil emulsion distemper over a coat of alkali resistant primer on surfaces of wall
M&L for preparing new or previously untreated surfaces of wood or wood based materials of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete.
M&L for preparing new or previously untreated steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete.
S&F for false ceiling work with Armstong (optra-FG microlook) Accoustical ceiling board of size 600x600,15mm thick @1.5 Kg/Sqm with superfine 15mm exosecd steel angle, the tiles should have humidity resistance> 88% thermal conductivity k=0.032 w/m, colourwhite and fibre performance class 0/class 1(BS476 class 6/7). the steelangle should be of armstrong make with 15mm wide T- section flanges colour white having rotary stitching on all T-section i.e main runner 1200mm & 600mm cross tees. the T section (powder coated) have a galvanising of 90 gms per M-2 perimeter trim to be armstrong wall angles of size 3000x19x19mm secured to walls at 450mm maximum centres complete all as per manufacturer's instructions and approved by Engineer-in-Charge.
M&L for preparing of old distempered surface of wall and applying two coat of oil emulsion distemper .
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade FRLS PVC cable IS:694 with multi stranded copper conductor of size 1.5 sqmm (Nominal area) drawn through and including rigid PVC conduit/ metelic conduit ISI marked not less than 20 mm dia with all PVC conduit fittings such as Tees, elbows, bend, reducers etc, concealed conduit wiring fixed on wall with all fittings including tee, junction boxes and provision of pressed steel terminal box 1.6 mm thick of suitable size with 3 mm thick plastic laminated sheet cover for mounting switch sockets and regulators and drawn continuous earth wire with and including PVC insulated unsheathed 1100 volts grade cable with multi stranded copper conductor of size 1.5 sqmm (Nominal area) connected to earth dolly complete all as specified and as directed by Engr-in-Charge for the followings:- Note :- (i) The cost of chases cutting on wall for concealing conduit, boxes, plate etc are included in the unit quoted rate. (ii) Switches, sockets, etc shall be measured and paid for separately.
(a) one light/fan/bell point controlled by one switch
(b) one 3 pin 5 amps socket out let on same board controlled by one switch
(c) one 3 pin 5 amps socket outlet on independent board controlled by one switch
All as per item No 56 above but for one power point 3 pin 16 amps socket outlet on independent board with FRLS PVC insulated unsheathed 1100 volt grade cable with multi stranded copper conductor of size 2.5 sqmm (Nominal area) including provision of earth wire FRLS PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 2.5 sqmm (Nominal area) cable common connected to earth dolly all as specified for one 3 pin 16 amps socket outlet controlled by one switch complete all as specified and as directed by Engr-in-Charge.
All as per item No 56 above but for one power point 3 pin 20 amps socket outlet on independent board with FRLS PVC insulated unsheathed 1100 volt grade cable with multi stranded copper conductor of size 4.0 sqmm (Nominal area) including provision of earth wire FRLS PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 4.0 sqmm (Nominal area) cable common connected to earth dolly all as specified for one 3 pin 20 amps socket outlet controlled by one switch complete all as specified and as directed by Engr-in-Charge.
S&F of switch piano flush type 5/6 Amps single pole one way 230/250 volts complete for one light/fan point/ 5 amp socket outlet controlled by one switch all as specified and directed by Engr-in-Charge
S&F socket outlet 5 pin, 5/6 amps flush type complete all as specified and directed by Engr-in-Charge.
S&F switch piano flush type single pole one way 16 amps complete all as specified and directed by Engr-in-charge.
S&F socket outlet 2 in 1 combination, 5 pin 6/16 amps flush type complete all as specified and directed by Engr-in-Charge
S&F Ceiling rose, surface bakelite, 60 x 50, mm two to three terminals.
S&F modular type power unit single phase 220 volts 32 Amps socket with control switch ISI marked 4 module complete.
S&F Stepped type electronic fan regulator make flush type and connecting up. Regulator shall be of Cat part No 14502 of Anchor / Cat part No 675530 of Legrand or equivalent model of make specified in appendix 'B' to particular specifications.
S&F factory made sheet metal enclosure distribution boards, (protection class IP-43) double door, verticle type suitable for mounting MCCBs/ RCCBs/ MCBs conforming to IS : 13032, IS : 8623, BS : 5484 with 200 Amps rating copper bus bar, triple pole and neutral, 4 ways, 415 volts. Note :- MCCBs/ RCCBs/ MCBs shall be measured and paid for separately under respective item of this schedule.
S&F MCCB, four pole, 415 Volt ,63 Amp rating, 16 KA ultimate breaking capacity fixed in DBs catered herein before.
S&F MCB, Single pole and neutral, 230 volt, 40 Amp rating 10KA, C series fixed in DBs catered herein before.
S&F MCB, SP, 230 volts, 40 Amp rating, 10 KA, C series fixed in DBs catered herein before.
Supply and fixed ceiling fan in size 1200mm sweep white colour 5 star rated copper wound energy saving with set of sweep/ extension rod / "U" clamp and other accessories single phase 50 Hzs incl making necessary electric connection using three core copper cable drawn through in PVC flexible conduit pipe complete. Make : Bajaj cat part No 250524 equivalent model of make Crompton Greaves / Havells/ Khaitan /Bajaj/ Orient
Supply and fixing exhaust fan single phase 240 volts 300 mm sweep steel body heavy duty with louver mounting bracket ISI marked 5 star rated energy saving less noise capacitor type incl making hole in brick wall plastering colour coading and all site required work for disturbed surface matching with existing and making electric connection using three core copper cable drawn through in PVC conduit pipe complete all as specified and directed. Make : Bajaj cat part No Model No MAXX AIR equivalent model of make Crompton Greaves / Havells/ Khaitan /Bajaj/ Orient
S&F LED surface mounting 2x2 light fitting 43 watt energy saving including making connection with three core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge. Note:- fiitings shall be of Make : Model No BCTBLS 43 W Z T WH of Bajaj or equivalent model of make Philips/Wipro. Light fitting of other make of higher capacity may be used without any price adjustment.
Supply and fixing of 60 watt LED security light fitting energy saving IP 66 protection in warm white colour with pressure die- cast housing with toughened glass and individual LEDs with secondary optics including making electric connection using three core copper flexible cable drawn through in PVC flexible conduit complete all as specified and directed. Note :- (i) Fitting shall be of Bajaj Cat No BRTFG 60W LED V3 WW ( EDGE) or equivalent model of make Philips/Wipro. Light fitting of other make of higher capacity may be used without any price adjustment. (ii) Cable from MCB/control Box to fitting shall be included in unit rate quoted by contractor.
M&L for sand cushioning (dry sand) to under ground cable for cable protection with layer of 8 cm deep before laying the cable and 15 cm depth after laying the cable, complete all as specified and as directed by Engr-in-Charge. Note : Only punned thickness of sand will be measured and paid.
M&L for brick, sub class 'B' well burnt, laid dry flat in trenches for protection of cable over LT/HT cable, complete all as specified and directed by Engr-in-Charge.
Supply and laying galvainesd steel tubing light grade 40 mm dia of bore fixed with pole/ surface of wall / laid in trench etc as site using 02 Nos clamp made out by GI strip in size 25x4 mm with nut bolt and washer etc all as directed.
Supply and laying XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 35 sqmm 4 core (earthed) in trenches including providing aluminium lugs suitable size and cable glands and nut bolts etc with electrical connection in terminal box and testing and commissioning complete all as specified and as directed by Engr-in-Charge.
Earthing complete with galvanised mild steel earth electrode plate 600 X 600 X 6 mm thick buried directly and vertically in ground connected to galvanised iron earth strip 25x4mm size by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth strip protected by galvanised iron 32 mm bore medium grade pipe with all fittings from the earth electrode fixed along pole with and including 25 x 6mm flat iron clamp, bolts, nuts and washers and watering pipe shall be 20 mm bore GI medium grade from top of the earth electrode to bottom of the earth pit including all excavation and earth work in any type of soil and removal of surplus soil upto 50 metre, PCC pit with pre-cast RCC cover with handle, charcoal/salt, funnel , CI frame etc complete all as directed. Notes :-(i) The concrete pit shall be made in PCC 1:3:6 type C-1, 40mm thick precast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate with suitable MS handle in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. Reinforcement in RCC cover shall be of 8mm dia TMT bars laid @150mm c/c both ways. (ii) Item includes the cost of 7.5 metre GI pipe for protection of earth strip. Any variation in length shall be adjusted through deviation order. (iii) Item includes cost of 7.5 metre earth strips. Any variation in length shall be adjusted through deviation order. (iv) Plate electrode shall be surrounded by adequate quantity of charcoal dust & salt to a packed thickness of 15 cm on all sides.
Supply, install, fixing and commissioning split type air conditioner copper of capacity 1.5 TR, five star rated with cordless remote control unit and in built air ioniser, plasma filter for better indoor air quality, star rated suitable for wall mounted, single phase, 230/250 volt AC including breaking necessary hole in wall for fixing indoor and outdoor unit and making good to disturbed surfaces with cement mortar to match with existing after commissioning, making necessary connections unplasticised PVC pipes medium duty 20mm dia for draining out condensed water all as required including necessary connection through making necessary connections through wall mounting voltage stabilizer copper wound for automatic operation single phase, naturally air cooled indoor type and designed for input voltage between 140 volt to 280 volts with output voltage stabilized at 230 V +/-2.5% with time delay relay and suitable for fixing / mounting on wall of capacity 5 KVA complete as per appproved by AGE (I) Manauri . Note :- (i) Quoted rates deem to be included cost of backet, drain pipe, voltage stabilizer, hole in brick wall etc. (ii) Make of Air conditioner & voltage stabilizer shall be as per Appendix 'B' to particular specifications.
singrourenterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .