| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | Rejected-Technical | - | Rejected-Technical L2 |
Tender Value
₹22.6 L
EMD Value
₹41,500
Closing Date
10 Sept 2020, 5:00 pmClosed
XEN Electrical Division No.II
XEN Elect Division No II
Providing power wiring therein
2020_PWD_39968_1
ED.II.GA.Tender/20-21-3141-42 dated 18.08.2020
Open Tender
Electrical Works
Item Rate
365 days
District Kinnaur
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
EE Elect Division No II
₹41,500
19 Oct 2020
25 Aug 2020
11 Sept 2020
25 Aug 2020
10 Sept 2020
25 Aug 2020
Amount
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required.
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-
Single pole 16 Amp. Cat-A.
Providing and fixing following rating, double pole (single phase & neutral) 10 KA breaking capacity 240 volts, Residual Current Breaker with Overcurrent Protection (RCBO), having a sensitivity current up to 300 miliampers, suitable for protection against leakage current, short circuit & over load, the existing MCB DB complete with connections, testing and commissioning etc. as required. Make: L&T, Havells, Schneider or any other approved by Engineer-in-Charge.
Double Module RCBO 40 Amp.
Four Module RCBO 63 Amp.
Providing, fixing and installation of following rating and breaking capacity MCCB with Thermal Release Having inbuilt Overload and Short Circuit Protection in the existing cubical panel board suitable for input voltage: 415/500 Volt AC, 50 Hz, complete with all accesories, including making connections, testing and commissioning etc. as required. Make: L&T, Havells, Schneider, Standard or any other approved by Engineer-in-Charge.
MCCB DU100H 3-Pole 32 Amp Breaking Capacity 30-KA
MCCB DU100H 3-Pole 63 Amp Breaking Capacity 30-KA
Distribution Board : -Supplying and fixing of following way L&T make MCCB incomer 3-PHASE 7- Segment SEGREGATED DB, of suitable dimensions made from 1.6 mm thick CRCA sheet on surface / recess with Incomer MCCB spreader links, busbar, 4 module sub-incomer in each phase and SP MCBs as outgoing, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, cable, identification labels interconnections, phosphatized and powder painted,Metal Door IP 43 including earthing etc. as required.
Double door-4 way (Cat.No. DBPGL004DD)
Double door-6 way (Cat.No. DBPGL006DD)
Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, unarmoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:-
Unarmoured cable 16 sq. mm (four core)
Providing and fixing 8 SWG (4 mm dia.) copper wire on surface or in recess for loop earthing along with existing surface/recessed conduit/sub-main wiring/cable as required.
Supplying & erection of Wiremesh HDG cable tray with EDRN fast coupler RCSN, Wall mounting brackets etc. as required complete in all respect. Make: legrand or its equivalent to the best satisfaction by Engineer-in-Charge.
Supplying and fixing electrical switch board, having 4 No. of 5/6 amp. Modular Switches and Modular Socket on suitable size of G.I. modular boxes of 12 modules (205mmx135mmx60mm) deep ( nominal size) on surface or in recess with suitable size along with modular base and cover plate for modular switches in the front including providing and fixing 4 No. 5 pin 5/6 amp modular socket outlet and 5/6 amp modular switch, connection, painting etc.as required. (For Light Plug/Computer Points)
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.
2x2.5 Sq. mm.
2x6.0 Sq. mm.
Wiring for circuit/sub-main with 4x2.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.2.5 Sq.mm.(4X2.5+2X2.5) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, unarmoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:-
Unarmoured cable 10 sq. mm (four core)
Unarmoured cable 16 sq. mm (four core)
Providing and fixing 8 SWG (4 mm dia.) copper wire on surface or in recess for loop earthing along with existing surface/recessed conduit/sub-main wiring/cable as required.
Supplying and fixing sheet metal bus-bar chamber suitable for 100 Amp. 415 volts capacity with 4 No. aluminium alloy or wrought aluminium strip bus-bars each of length 450mm & cross-sectional area (25mmx6mm), enclosure made from 1.6 mm thick M.S. sheet having overall dimensions (530mmx400mmx150mm) nominal with all accessories including connections, earthing the body etc. as required:-
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-
Single pole 6 Amp. Cat-A.
Providing and fixing following rating, double pole (single phase & neutral) 10 KA breaking capacity 240 volts, Residual Current Breaker with Overcurrent Protection (RCBO), having a sensitivity current up to 300 miliampers, suitable for protection against leakage current, short circuit & over load, the existing MCB DB complete with connections, testing and commissioning etc. as required. Make: L&T, Havells, Schneider or any other approved by Engineer-in-Charge.
Double Module RCBO 25 Amp.
Double Module RCBO 40 Amp.
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-
Triple pole & Neutral. 40 Amp.Cat-A.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-
Double door-4 way
Double door-6 way
Double door-8 way
Supplying and fixing G.I. Modular box with 1-module plate and cover in recess including providing and fixing RJ 45, Cat-6 Internet Socket 1-modular complete with connections etc. as required. Make: L&T, Havells or any other approved by Engineer-in-charge.
Supplying and fixing of following type of Input/Output switch for computer internet connectivity complete with RJ45 connector & enclosers including all accessories making connections, testing & Commissioning etc. as required. Make: D-link or any other approved by Engineer-in-Charge.
8-Port Input/Output Switch
16-Port Input/Output Switch
Wiring for UTP CAT-6 computer LAN cable with star seprator Electrolytic grade solid annealed bare copper conductor, 4 Pair unshielded twisted pair (UTP) Industrial cables for LAN Network including PVC conduit in surface/recessed complete with connection etc. as required. Make: Havells or any other approved by Engineer-in-charge.
ARUN KUMAR SHARMA
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.PDF
finance_59009.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .