| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.0 CrAccepted-AOC 84 A VIJAY NAGAR COLONY LALGHATI PO NAYAPURA BHOPAL 462032 | 462032 | ₹1.0 Cr | 1 | Accepted-AOC Lowest and reasonable |
| 2 | 2₹1.2 Cr+₹13.3 L (12.8%)Rejected-Finance NEAR OLD POST OFFICE SUJANPUR TEH DISTT PATHANKOT PATHANKOT 145001 | PATHANKOT | PUNJAB | 145001 | ₹1.2 Cr+₹13.3 L (12.8%) | 2 | Rejected-Finance Other than lowest |
| 3 | 3₹1.2 Cr+₹13.5 L (12.9%)Rejected-Finance | ₹1.2 Cr+₹13.5 L (12.9%) | 3 | Rejected-Finance Other than lowest |
| 4 | 4₹1.2 Cr+₹13.7 L (13.1%)Rejected-Finance 13 29 3RD FLOOR EAST PATEL NAGAR NEW DELHI 110 008 | WEST | DELHI | 110008 | ₹1.2 Cr+₹13.7 L (13.1%) | 4 | Rejected-Finance Other than lowest |
| 5 | 5₹1.2 Cr+₹14.5 L (13.9%)Rejected-Finance | ₹1.2 Cr+₹14.5 L (13.9%) | 5 | Rejected-Finance Other than lowest |
Tender Value
₹1.4 Cr
EMD Value
₹2.1 L
Closing Date
9 Sept 2021, 6:00 pmClosed
CWE Mhow
HQ CWE Mhow Cantt Mhow 453441
PROVISION OF ENERGY SAVING LED LIGHTS AT OTM ACCN AND SECURITY LIGHTS AT INFANTRY SCHOOL MHOW
2021_MES_466109_1
CWE(MHOW)/13(T) OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
HQ CWE Mhow
Please refer tender documents
8 documents required · 8 mandatory
₹1,000
GE (M) Inf School Mhow
₹2.1 L
Yes
6 Nov 2021
7 Aug 2021
11 Sept 2021
7 Aug 2021
9 Sept 2021
27 Aug 2021
Amount
Supply and fix in repairs integrated LED tube light fitting 1x18/20 Watt, 6000K complete fitting with all accessories duly connection with three core flexible copper cable duly fixed on two nos of PVC square boxes including taking down the existing complete all as specified and directed. (Make:- Havells Cat No. LHEXBLP7PN1W018 , Crompton Cat Pt No. LDL-20-CDL, Bajaj Cat Pt No BCLSB 18WH or equivalent in wipro) .
Supply and fix in repairs integrated LED tube light fitting 1 x 9/10 Watt, 6000K complete fitting with all accessories duly connection with three core flexible copper cable duly fixed on two nos of PVC square box including taking down the existing complete all as specified and directed. (Make:- Havells Cat No. LHEXBLP7IN1W009 , Crompton Cat Pt No. LDL-10-CDL, Bajaj Cat Pt No. BCLSB 10WH).
Supply and fix in repairs integrated LED NU Bulb 9/10 Watt, 6500K, B22 base, 3 star, adjustable typecomplete fitting with all accessories duly connection with three core flexible copper cable duly fixed onwall including taking down the existing complete all as specified and directed. (Havells Cat Pt No. LHLDEUECNL8R009 or equivalent in Bajaj,Crompton, wipro).
Supply and fix in repairs Maxoled LED tube light T-8 type, 1x20 Watt, 6500K with extruded Al heat sink for efficient heat dissipation including taking down the existing complete all as specified and directed. (Make:- Havells Cat No. LHLDDCXCML8Q020 , Bajaj Cat Pt No. BLRB 20 CW LED, Crompton Cat No. LT8-20-865-2 or equivalent in wipro)
Supply and fix in repairs batten for retrofit type LED tube upto 1x22 Watt, pre-wired for LED tube complete with all accessories duly connection with three core flexible copper cable and duly fixed on and including two Nos PVC square boxes including taking down the existing complete all as specified and directed. (Make:- Crompton Cat No. IGP161LT8-16, Havells Cat No. LHFXCENNTN1W020, Bajaj Cat Pt No.BLRB-DB 118I,) or equivalent in wipro) Note for item Nos. 04 & 05:- Makes of these items should be same and compatible with eath other.
S&F in repairs LED fittings 36watt , 6000K ceiling lights recessed mounting type panel complete with driver duly connection wire including taking down the existing complete all as specified and directed . (Make, Havells Cat Pt No. PLANO2X2PLR36WLED857S Crompton Cat No.LCTLRN-36-FO-CDL /Bajaj Cat No. BZRSQL36LXE WH OD SD)
Supply and fix in repairs Wall light fittings suitable for & including LED bulb of 7 watt, including connection with all necessary fixing accessories including taking down the existing complete all as specified and directed by Engr-in-Charge. (Make :- Havells Cat Pt No.LHDL06160099or equivalent , Bajaj, Philips, Crompton, Wipro).
Supply & fix in repairs LED Bulk Head luminaire 10W, 6000K pressure die cast housing with IP66 protection complete with electric connection including taking down the existing complete all as specified and directed by Engr-in-Charge. (Make:- Havells Cat No. HEXAFT10WLED857SSYMBOPC, Crompton Cat No. LBH-10-CDL, Bajaj Cat No. BIBWP 10W LED or equivalent in Wipro)
S&F in repairs recess mounting type Octane LED square panel aluminium dia cast edge fixture 18W, 6500K in white finish with opal diffuser with electronic driver duly connection with copper cable including taking down the existing etc. (Make, Havells Cat No. LHEBHEP71Z1W018, Crompton Cat Pt No. LSCSM-18W-CDL/NW/WW, Bajaj Cat Pt No. BPSLR18W WHSQ)
S&F in repairs LED round light fitting fixture of 15W, 6500K recess mounting type complete with driver duly connection with copper cable including taking down the existing etc. (Make, Havells Cat No. LHEBHDP71Z1W015 , Crompton Cat Pt No.LSDEP-18-CDL, Bajaj Cat Pt No. BPSLR15WWH).
S&F in repairs LED 9W Inverter Bulb B22 Base CDL 3 star Lamp including taking down the existing etc. (Make:- Havells Cat No. LHLDEGEDML8O009 or equivalent in Bajaj, Wipro and Crompton)
S&F in repairs LED fittings 36 watt , 6000 K ceiling lights Surface mounting type panel complete with driver duly connection wire including taking down the existingcomplete all as specified and directed by Engr-in-Charge.etc. (Make, Havells Cat Pt No. PLANOSURFACE2X2PLS36WLED857S Crompton Cat No.LCTLSNE-36-FO-CDL ,Bajaj Cat No. BZSSQL36WLED WHi and equivalent in Wipro)
Supply and fix in repairs LED security light fittings 30 Watt, 6500K complete fitting having pressure dia cast aluminium housing with heat resistant toughened glass & IP 66 protection fixed on and including sufficient length and appropriate size GI bracket with all accessories duly connection with three core flexible copper cable including taking down the existingcompletecomplete all as specified and directed . (Make:- Havells Cat No.LHEXAYP7PN6K030 Crompton Cat No. LSTS-30-CDL, Bajaj Cat No. ENXTP30LWH CR PC SD)
S&F in repairs LED round light fitting fixture of 6W, 3000K recess mounting type complete with driver duly connection with copper cable including taking down the existing etc. (Make, Havells Cat No. LHEEGEPB1E1W006 or equivalent in Crompton,Bajaj,Wipro)
Supplying,erecting and fixing steel tublar poles with cast iron base plate of size 300mm x 300 mm x 6 mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 ( 9.0 mtrs long) including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30 cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbring of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2"(inch) wide including taking down old unserviceable PCC poles of any type complete all as specified and directed. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule. (Make :- A) BHARAT CONDUIT (B) JINDAL STEEL (C) BCW KANPUR (D) NATIONAL TUBING CO KANPUR
Discnnecting and dismantling old U/S High Mast light and supply and fix LED Flood Light 150 W housing made out of pressure die-cost aluminium alloy with toughned glass,IP-66 protection, working on 240 volts, 50 HZ, consisting of reflective lens wired with appropriate driver PF>0.98 having over voltage protection upto 440 volts, Surge protection level>10 10 KV, thermal short circuit protection THD< 10 % made up of long life LED chips (SMD) in modular with Ra>70, and LED lumen efficiency > 140 lumen per watt , luminior efficiency> 110 Lumens/watt power LED should be of more than 01 watt CCT should be between 5700 K - 6500 K fixed on swan neck poles or straight poles incl making necessary electric connections complete all as specified and as directed by Engr-in-charge (i) The firm has to give warranty for street light fittings including driver minimum for 03 years for any defect's developed during the period. (ii) The contractor shall submit the third party LM 79 report from any NABAL approved laboratory . (iii) The fitting should have BIS, CRS no (iv) The fitting should have min 40 mm dia and also must fitted in both swaged pole/ swan nek pole. Note:- PVC 1.5 sq mm 3 core/3 run ( red, black and green colour) multistranded copper conductor cable required for street light connection are deemed to be included in the rate quoted. (Make- Havells cat part no- JETAIRISFLS150WLED757PSYMLTG , Bajaj cat part no- BJFL 150W LED or equivalent in Wipro and Philip).
Discnnecting and dismantling old U/S street light and supply and fix LED street/security light fitting 60 W housing made out of pressure die-cost aluminium alloy with toughned glass,IP-66 protection, working on 240 volts, 50 HZ, consisting of reflective lens wired with appropriate driver PF>0.98 having over voltage protection upto 440 volts, Surge protection level>10 10 KV, thermal short circuit protection THD< 10 % made up of long life LED chips (SMD) in modular with Ra>70, and LED lumen efficiency > 140 lumen per watt, beam angle along the drive way, 120 degree, beam angle across the drive way, 80 degree luminior efficiency> 110 Lumens/watt power LED should be of more than 01 watt CCT should be between 5700 K - 6500 K fixed on swan neck poles or straight poles incl making necessary electric connections complete all as specified and as directed by Engr-in-charge (i) The firm has to give warranty for street light fittings including driver minimum for 03 years for any defect's developed during the period. (ii) The contractor shall submit the third party LM 79 report from any NABAL approved laboratory . (iii) The fitting should have BIS, CRS no (iv) The fitting should have min 40 mm dia and also must fitted in both swaged pole/ swan nek pole. Note:- PVC 1.5 sq mm 3 core/3 run ( red, black and green colour) multistranded copper conductor cable required for street light connection are deemed to be included in the rate quoted.(Make :- Bajaj/Philips/WIPRO)
Supply laying & testing of XLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of size 10 Sqmm nominal cross section x 2 core complete. (Make :- Gloster/Havells/Polycab/Finolex)
Excavation in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out complete .
Ditto All as per item No 19 above but for each additional 1.5 m or part thereof in depth beyond the first 1.5 mtr complete.
M&L for Cement concrete 1:2:4 type B 2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete all as specified and directed.
M&L for Cement concrete 1:4:8 type D 2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete all as specified and directed.
M&L for Cement concrete 1:3:6 type C 1 (using 20 mm graded stone aggregate) as in roof kerbs or pole coupling of size 300 x 300 mm or chamfered on edges all as specified and directed.
Returning , filling in includiing spreading levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil comlete all as specified and directed
Removing excavated material (surplus soil) to a distance not exceeding 50 mtrs and depositing where directed at a level not exc 1.5 m above the starting point all as specified and directed.
Material and labour for approved river sand cushioning for under ground cable in trenches 8 cm before laying and 15 cm after laying of cable and punned thickness of sand shall be measured and paid for 18 cm only after punned/consolidated thickness complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type-1, flat, size 250mm x 150mm x 40mm, ISI marked, laid flat across the cable length complete all as specified and directed. (Make: Mahtab tiles / Alankar Tiles/Pearlers Industries/SIND Mozaic Gujrat/JJ Concrete Lucknow).
Supply and fixing GI tube light grade of 15 mm dia size for protection of UG cables along with pole using 25 x 5 mm thick MS FI clamps of required shape with bolts, nuts, washers along the poles complet all as specified & directed. (Make:- TATA JINDAL , SWASTIK)
Supply and fixing Steel tubes, galvanised, light grade, ISI marked 40mm bore for protection of cable under floor, road and on wall complete. (Make:- TATA JINDAL , SWASTIK)
Supply and fix moulding compound Street light junction box of size 250 mm x 200 mm x 105mm complete with shock and rust proof, termite resistant, tamper proof , front openable type and including suitable provision for single phase, two wire cable (size upto 25 Sqmm 2 Core) incomming & outgoing loop -in loop connection and including one no. MCB SP 6 Amp including non metallic clamps and GI nut bolts and washers of suitable size and fixed on pole / wall complete. (Make - Sintex Cat part No GSJB 2520 or equivalent in Hensel/ABB).
Supply, installation testing and commissioning replacement of street light control box as a pole mountable enclosure conforms to IP-64 suitable for 440/230V, AC, 50 Hz, consisting of a light sensitive control system, power contactor for load switching, MCB and terminal suitable for 1 phase, 5 KW load blocks all as specified by (Make:- Swadeep Nature Swith model No 02EC5kW1P or equivalent in CG/L&T/phillips
Supply, installation testing and commissioning replacement of street light control box as a pole mountable enclosure conforms to IP-64 suitable for 440/230V, AC, 50 Hz, consisting of a light sensitive control system, power contactor for load switching, MCB and terminal suitable for 3 phase, 5 KW load blocks all as specified (Make :- Swadeep Nature Swith model No 02EC5kW3P or equivalent in CG/L&T/phillips)
Supply and fixing two single core weather proof cable with multistranded copper conductor of size 2.5 sqmm and drawing into PVC junction box to GI pipe bracket and connect to street light fittings including one run of insulated cable 1.5 sqmm aluminium conductor green coloured connected from PVC junction box to street light fittings for street light fittings earthings. (Make :- Gloster/Havells/Polycab/Finolex)
M&L for street light bracket made out of 40mm dia medium grade GI pipe of 1.2m length bent to required shape suitable for fixing street light / security light fitting on Steel tubular pole / RCC pole / building wall including two Nos clamps made out 30mm X 5mm flat with suitable nuts and bolts (clamp type - as per site requirement ) including two coats of aluminium paint over a coating of red oxide primer and Taking down of existing unserviceable rusted street light brackets with clamps, nuts and bolts etc . ,complete all as directed.
M/S SURINDER KUMAR MAHAJAN
M/s Matadeen Ramchandra Agarwal
Leo Air and Power Solution pvt Ltd.
KR POWER INFRA INDIA PVT LTD.
VEENUS ENGINEERS
C L BHATIA
M/S ANIL KUMAR
M/s Gupta Constructions
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .