Loading…
Loading…
Tender Value
₹7.3 Cr
EMD Value
₹14.7 L
Closing Date
1 Jun 2026, 3:30 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
SIG WORKS
15 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less ; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. As per Clause No. 10.2 of Tender Form (second Sheet) of Annex.I of Part-I of GCC2022,updated as per RB Letter No.2022/CEI/CT/GCC2022/Policy Dated-14.07.22 with up to date correction slip.
a) The tenderer must have successfully completed or substantially completed anyone of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work each costing not less than the amount equal to 60% of advertised value of the tender. (b) (1) In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges substructure, superstructure etc.), tenderer must have successfully completed or substantially completed anyone of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or (iii) One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(1): Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. (b) (2) In such cases, what constitutes a component in a composite work shall be clearly pre-defined with estimated tender cost of it, as part of the tender documents without any ambiguity. (b) (3) To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 7 of the Standard General Conditions of Contractor through subcontractor fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Signal & Telecom Engineer in writing. However, if required in tender documents by way of Special Conditions, a formal agreement duly notarised, legally enforceable in the court of law, shall be executed by the main contractor with the subcontractor for the component(s) of work proposed to be executed by the subcontractor(s), and shall be submitted along with the offer for considering subletting of that scope of work towards fulfillment of technical eligibility. Such subcontractor must fulfill technical eligibility criteria as follows: The subcontractor shall have successfully completed at least one work similar to work proposed for subcontract, costing not less than 35% value of work to be sub-letted, in last 5 years, ending last day of month previous to the one in which tender is invited through a works contract.
Note: for subletting of work costing up to Rs 50 lakh, no previous work experience of subcontractor shall be asked for by the Railway. In case after award of contract or during execution of work it becomes necessary for contractor to change subcontractor, the same shall be done with subcontractor(s) fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract, with prior approval of Chief Signal & Telecom Engineer in writing. Note for Item 15.1: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organization, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Meaning of similar works:" The similar nature of work defined is "Any RRI/PI/EI/MACLS Supply, Installation Testing, Commissioning Signalling work OR Any RRI/PI/EI/MACLS Alterations Signalling work OR Any CTC/TMS Work"
6 conditions · 5 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Submission of undertaking by the tenderer that "Authorization of OEM's of EI system (RDSO Spec No. RDSO/SPN/192/2019 Ver. 2 with latest amendment) (for Supply, Installation, Testing, Commissioning and support after commissioning from OEM for trouble free working of installed EI system will be submitted before the supply of materials to confirm compliance with extent RDSO guidelines and to meet contract specific requirements." at the time of bidding. Non submission of undertaking will lead to summarily rejection of the bid. Note: The successful tenderer shall submit OEMs authorization before the supply of materials to confirm compliance with extent RDSO guidelines and to meet contract specific requirements.
Ajmer Division: - Providing Design, manufacture, supply, installation, testing and commissioning of Electronic Interlocking (EI) systems along with execution of indoor and outdoor complete MACLS work with Std-III to suit RE standards at Khemli station in C/W Development of common user facility for line no. 4 at Khemli (KLH) station, CONCOR siding and development of rail siding (UCWL) at Khemli (KLH) station in Ajmer Division of NWR
SNT-AII-14-2026-27
SNT-AII-14-2026-27
Open
Works - General
270 Days
Ajmer, Rajasthan
₹0
₹14.7 L
1 Jun 2026
6 May 2026
18 May 2026
470 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 7,25,38,416.28 | ||
| — | 238.00 | Per Functional Vital Bit | — | ||
| Design, manufacture and supply of Electronic Interlocking (EI) system complete as per RDSO specification No. RDSO/SPN/192/2019 Ver. 2 or RDSO/SPN/203/2011 Ver. 1 for Big Yard having more than 200 Routes or latest, and as per description given in NWR S&T SOR-2026, item no. 01010100, and detail mentioned in the tender document. Note: Detailed description of item may be seen in NWR S&T SOR 2026. Inspection: RDSO for EI supply items. Inspection charges: Borne by Railways Payment terms:100% after Supply For Station with routes more than 50 and less than 200 | — | — | — | 1,69,21,688.14 | |
| — | 1.00 | — | — | ||
| Installation, wiring, testing and commissioning of EI System with 'Hot Standby' architecture as supplied upto 6 (six) line station. It includes transportation of material from consignee's depot to the site, erection and grouting of EI Relay Racks, fixing and wiring of all the interfacing relays (Vital & Non-Vital), installation and wiring of Microprocessor equipments, interface equipments, power supply equipments and all other associated accessories to make complete EI system to be functional. Note: (i) Technical Requirements are attached with tender document (ii) Contractor has to arrange simulator/simulation testing panel for testing and commissioning by Selection Table and Square Sheet for each Signalling function.(iii) Installation, wiring, testing and commissioning of EI system will be done by OEM after following all the guidelines/directives issued by RDSO from time to time. Inspection: Consignee Inspection charges: None Payment terms: 100% after commissioning | — | — | — | 7,51,843.88 | |
| — | 1.00 | — | — | ||
| Supply of Instruments and Tool Kits required for Trouble Shooting and repair of hardware and software for EI system should be supplied for stations. (This includes tools required for EI maintenance sorts of crimping, insertion, removal, general purpose tools like screw drivers, spanners, PCB extractor, temp. controlled soldering iron, wire cutter, nose pliers etc. & measuring instruments with carrying case/ holders/ cabinet for technicians/ J.E. for testing, Maintenance and repair at site). Each set comprises of the following :- * Crimping tool for all types of special cable assembly used in EI system. * Insertion tool for all types of special cable assembly used in EI system. *Removal tool for all types of special cable assembly used in EI system. * Digital multi-meter (Fluke 111 or better) * Steel cabinet/ Almira, Size: 1980mm height, 915 mm width and 485 mm depth (Godrej Make/Jalaram) of good quality to store tool, spare cards and documents. * Steel Book rack Size: 1850mm height, 900 mm width and 316 mm depth for keeping documents. (Godrej Make/Jalaram) * Clamp Earth Tester. (as per specs mentioned in tender document.) * Clamp Current Meter (fluke 362 or superior) * Ferrule tagging printer for cable/wires (Supported label tape sizes: 6 / 9 / 12 / 18 / 24 mm). Inspection: Consignee Inspection charges: None Payment terms: 100% after supply | — | — | — | 1,51,338.52 | |
| — | 3.00 | Man-Days | — | ||
| Training of Technician/ Jr. Engineer for installation, Commissioning, Testing, Repairs & Troubleshooting of EI system. (Hard copies of training material/ course modules to be given to each participant). Inspection: Consignee Inspection charges: None Payment terms: 100% after execution | — | — | — | 3,994.05 | |
| — | 1.00 | — | — | ||
| Design, preparation & supply of drawings in computer print copies and original tracing in AUTO CAD FORMAT for Electronic Interlocking at each station. After completion of the work, the completion drawings incorporating completion details are to be supplied as per Technical Specifications given in tender document (upto 6 Line). The technical specifications are as per ANNEXURE-01010100 of SOR. Inspection: Consignee Inspection charges: None Payment terms: 100% after execution | — | — | — | 2,11,776.71 | |
| — | 2.00 | — | — | ||
| Supply of embedded fanless PC based VDU control terminal as per RDSO spec. No. RDSO/SPN/192/2019 Ver. 2 or latest & RDSO TAN No. - STS/E/TAN/3007 version 1 dated:02.11.12. The size of VDU shall be minimum 42 inch. Note: (i) Technical requirements shall be mentioned in the tender document. (ii) One revolving chair should be supplied with control terminal. Inspection: Consignee Inspection charges: None Payment terms:100% after supply | — | — | — | 9,86,482.96 | |
| — | 2.00 | — | — | ||
| Installation, wiring, testing and commissioning of embedded fanless PC based VDU control terminal as per RDSO spec. No. RDSO/SPN/192/2019 Ver. 2 or latest & RDSO TAN No. - STS/E/TAN/3007 version 1 dated:02.11.12. Note: (i) Technical requirements shall be mentioned in the tender document by tendering authority. Inspection: Consignee Inspection charges: None Payment terms:100% after commissioning. | — | — | — | 2,46,620.74 | |
| — | 1.00 | — | — | ||
| Supply of embedded fanless PC based Maintenance terminal as per RDSO spec. No. RDSO/SPN/192/2019 Ver. 2 or latest & RDSO TAN No. - STS/E/TAN/3007 version 1 dated:02.11.12. The size of VDU shall be minimum 42 inch. Note: (i) Technical requirements shall be mentioned in the tender document by tendering authority. (ii) One table of suitable size along with revolving chair should be supplied with Maintenance terminal. Inspection: Consignee Inspection charges: None Payment terms:100% after supply | — | — | — | 4,64,279.54 | |
| — | 1.00 | — | — | ||
| Installation, wiring, testing and commissioning of embedded fanless PC based Maintenance terminal as per RDSO spec. No. RDSO/SPN/192/2019 Ver. 2 or latest & RDSO TAN No. - STS/E/TAN/3007 version 1 dated:02.11.12. Note: (i) Technical requirements shall be mentioned in the tender document. Inspection: Consignee Inspection charges: None Payment terms:100% after commissioning. | — | — | — | 1,16,069.88 | |
| — | 1.00 | — | — | ||
| Supply of offline domestic sine wave type inverter of 1000VA or above with suitable rating tubular batteries and UPS make of Su-KAM, Luminous, Microtek or other reputed brand for the backup of Maintenance VDU of EI. Inspection: Consignee Inspection charges: None Payment terms:100% after Supply. | — | — | — | 25,101.59 | |
| — | 1.00 | — | — | ||
| Installation, testing and commissioning of offline domestic sine wave type inverter of 1000VA or above with suitable rating tubular batteries and UPS make of Su-KAM, Luminous, Microtek or other reputed brand for the backup of Maintenance VDU of EI. Inspection: Consignee Inspection charges: None Payment terms:100% after commissioning. | — | — | — | 6,275.4 | |
| — | 3.00 | — | — | ||
| Preparation of SWR literature in English along with associated mid-section interlocked gate with all corrections as per approved SWRD & approved SIP. For these all-technical corrections, editing, grammatical correction etc. are to be carried out and one rough print to be given to railways for approval before printing, as required for final processing of CRS sanction. This also includes preparation of maintenance cards in format provided by Rly. Inspection: Consignee Inspection charges: None Payment terms:100% after execution. | — | — | — | 12,992.82 | |
| — | 3.00 | — | — | ||
| Translation of Station Working Rules from English to Hindi and framing out in DIGLOT form (or similar software) as per extant Rly practice. The required SWR in English will be provided by the contractor and has been covered separately in item no. 01011800 of Chapter 1 of SOR. Inspection: Consignee Inspection charges: None Payment terms:100% after execution. | — | — | — | 16,168.47 | |
| — | 16.00 | — | — | ||
| Making photocopies & binding of the SWR literature in English/Hindi/Diglot form as per Railway practice. Inspection: Consignee Inspection charges: None Payment terms:100% after execution. | — | — | — | 3,437.6 | |
| — | 900.00 | — | — | ||
| Preparation and supply of laminated one set of all the completion plans including circuit diagrams and indoor as well as outdoor completion documents on standard 75-micron polyester film for station in Auto CAD. 6 (Six) sets xerox copies will also be provided for each of the documents mentioned below: Cable Route Plan, Cable Core Chart, Location details plan for all the locations, Cable termination details, Signalling Plan, SWR Diagram, Wiring Diagrams, Selection table, Locking table, Contact analysis, Fuse and Tag Block analysis of Relay Rack, CT rack, Control cum Indication Panel/VDU Diagram, Power Panel Diagram, Track circuit plan, rack erection plan and Junction Box details etc. Inspection: Consignee Inspection charges: None Payment terms:100% after execution. | — | — | — | 1,74,465 | |
| — | 1.00 | — | — | ||
| Supply, Installation, testing & commissioning of new modular control desk size 4102x2576 mm for provision of 02 Nos. Monitors made in "XLAT" system as per approved drawing by Engineer in charge. The control desk should be ANSI-BIFMA e3-2019 certified/tested at least for level 3 (from UL/Intertek). 1. Table Top: The material of the working surface shall be made of thermally treated Aluminium - Trihydrate and acrylic resin material supported on minimum 25mm thick MDF base. 2. Structure: Powder Coated Aluminium Sturdy Structure and extreme side Aesthetic Legs. The structure shall be rigid enough to withstand BIFMA X5.5: 2014 (Latest Edition) 3. Monitor Arm: - UL certified monitor arm assembly shall have auto lock, push & remove feature for quick release of VESA mounts and modular arm extensions for ease in maintenance and fixing of monitor by one technician within 30 seconds without using any tools. 4. Shutters & Side Legs: - Front and back shutters hall be of 18 mm Laminated MDF Board with premium finish. Side leg shall be of 25mm of the same finish. Entire console must be Greenguard Gold certified. 5. Slat Wall shall be made of approx. 2mm thick Extruded Aluminium (HE9WP aluminium alloy) and designed in such a way that no joints or gaps are visible in the entire width of the console. The control desk will be provided for storage in the XLAT system, this includes space for housing two numbers of embedded PC, 2 nos. of inverter, 2 nos. of FDMS and their power supply arrangement with proper ventilation & cooling arrangement for CPR cabinet. (To be got approved from Engineer in Charge before supply). Inspection: Consignee Inspection charges: None Payment terms:100% after execution. | — | — | — | 1,54,988.05 | |
| — | 3.00 | — | — | ||
| Supply & Installation of Modular power supply arrangement for VDU and industrial PC (Embedded PC) with input and output redundancy arrangement and Hot pluggable Modules as per RDSO specification. Make Gallant or similar. One set consists of 1. Input O- ring diode module with potential free -1 No contacts (PFC) for two 110 V DC sources from IPS and single 110 VDC bus Qty 1 No. 2. Isolated Inverters (Master / slave) - Input-110 V DC Output: 120 V AC/220V A500VA - 02 Nos. 3. Isolated DC-DC convertors- Input: 110 v DC Output: 24 V DC/ 10A, Qty -10Nos. 4. 3 U SS rack with back panel mother board /front panel power connectors inverter auto change over switch and all required over switch and all required protection circuits (3U height for main rack 132.5mm +/-10% & 1U height for mounting 44.5mm +/- 10%) Qty - 1 No. Make Gallant or similar. (This item is for Operating VDUs of EI system) Inspecting Agency : (i)for inverters and converters : RDSO (ii) for other items : Consignee Inspection Charges: (i) Borne by Railways (ii) None For Supply of Modular power supply arrangement. Payment Terms: 100% after Supply | — | — | — | 6,54,868.8 | |
| — | 3.00 | — | — | ||
| Supply & Installation of Modular power supply arrangement for VDU and industrial PC (Embedded PC) with input and output redundancy arrangement and Hot pluggable Modules as per RDSO specification. Make Gallant or similar. One set consists of 1. Input O- ring diode module with potential free -1 No contacts (PFC) for two 110 V DC sources from IPS and single 110 VDC bus Qty 1 No. 2. Isolated Inverters (Master / slave) - Input-110 V DC Output: 120 V AC/220V A500VA - 02 Nos. 3. Isolated DC-DC convertors- Input: 110 v DC Output: 24 V DC/ 10A, Qty -10Nos. 4. 3 U SS rack with back panel mother board /front panel power connectors inverter auto change over switch and all required over switch and all required protection circuits (3U height for main rack 132.5mm +/-10% & 1U height for mounting 44.5mm +/- 10%) Qty - 1 No. Make Gallant or similar. (This item is for Operating VDUs of EI system) Inspecting Agency : (i)for inverters and converters : RDSO (ii) for other items : Consignee Inspection Charges: (i) Borne by Railways (ii) None For Installation of Modular power supply arrangement. Payment Terms: 100% after Commissioning | — | — | — | 1,63,717.2 | |
| — | 170.00 | — | — | ||
| Addition/alteration in existing relay room wiring. It includes supply of PVC insulated indoor Railway signalling cable @ 40<45@Core/40-Core) of (1/0.6) sqmm as per RDSO Spee. No. IRS/S-76/89 (Amnd.2 or latest) for wiring between relay room and SM's/Panel room & Relay room to DP in SM office for block working. This also includes supply of PVC insulated jumper wires of multi strand 16/.2 mm, tinned in all colours as per RDSO Specn.No.IRS-S-76/89(Amnd.2 or latest). This item will include bringing all the power supplies from power room to respective bus bars on relay racks by using 10/6 sqmm copper flexible wire as per instructions of engineer incharge. This will include wiring between control panel and relay room if required. All wiring will be done as per standard practice of North Western Railway with neat dressing & threading. The item includes supply & wiring of tag block, fuse with bases (G-Type and ND Type) and all other related material required for complete indoor wiring in relay room. Inspection: Consignee Inspection charges: None Payment terms:100% after execution. | — | — | — | 1,07,227.5 | |
| — | 1.00 | — | — | ||
| Supply of Micro Processor based Data Logger System with 4096 digital and 32 analog inputs as per RDSO Spec. No. IRS (S) 99/2006 or latest with laser printer 22 ppm (Only branded HP/Brother/Canon). It includes supply of all the items required for complete indoor relay room wiring from data logger to relay rack tag blocks, drawing/extension of power supply upto Data Logger. It includes relay room door lock checking arrangement, commercial power supply monitoring arrangement & monitoring of DG sets, ELD, IPS, UFSBI, BI, interlinking and networking of Data logger. It also includes supply of leased line MODEM, suitable online UPS (minimum 6 hours backup) and other interfacing cards, if required for networking of Data Logger. This also includes supply of one no. composite computer and printer table (Godrej work station table or similar) for keeping processor module and one number Godrej operator chair Model PCH7001 or similar. Note: Total numbers of relays and other signalling functions/gears required to be wired as per list circulated vide RDSO Letter No. STS/E/Data logger dtd.12.09.2011 or latest guidelines. Inspection: RDSO Inspection charges: Borne by Railways Payment terms:100% after supply | — | — | — | 20,03,980.1 | |
| — | 1.00 | — | — | ||
| Installation, wiring, testing & commissioning of Micro Processor based Data Logger System with 1024/1280/ 4096 digital and 32 analog inputs as per RDSO Spec. No. IRS (S) 99/2006 or latest. It cover complete indoor relay room wiring from data logger to relay rack tag blocks, drawing/extension of power supply upto Data Logger. It includes relay room door lock checking arrangement, commercial power supply monitoring arrangement & DG sets, ELD, IPS, UFSBI, BI interlinking and networking of Data logger. All material required for wiring, networking, power supply monitoring, door-locking arrangement etc will be supplied by contractor. Note: Total numbers of relays and other signalling functions/gears required to be wired as per list circulated vide RDSO Letter No. STS/E/Data logger dtd.12.09.2011 or latest guidelines. Networking of data logger includes extraction of data report from test room. For networking, required communication channel (Quad/ OFC cable) will be arranged/provided by Rly in SM/ASM's room or in OFC Porta Cabin and it will be extended by contractor upto location of data logger by using CAT-5/6 telecom cable with proper casing and capping. The contractor will supply all the material like CAT-5/6 telecom cable, casing & capping, nuts, bolts etc. The final commissioning will be done after filling up of Pre- Commissioning checklist (circulated by RDSO) with the OEM representative. Inspection: Consignee, Inspection charges: None Payment terms:100% after commissioning | — | — | — | 1,46,220.7 | |
| — | 1.00 | — | — | ||
| Supply of Failure Analysis & Fault Diagnostic software for data logger upto 4096 digital inputs at a station. Inspection: Consignee, Inspection charges: None Payment terms:100% after supply. | — | — | — | 47,083.83 | |
| — | 1.00 | — | — | ||
| Installation and commissioning of Failure Analysis & Fault Diagnostic software for data logger upto 4096 digital inputs. Inspection: Consignee, Inspection charges: None Payment terms:100% after commissioning | — | — | — | 11,770.95 | |
| — | 1.00 | — | — | ||
| Supply of Failure Analysis System (FAS) as per Technical Specifications. The specification of FAS should be got approved from the Engineer in charge before supply. Note: The Specification of FAS shall be as per technical specification given in contract Agreement or higher version as approved by Engineer In-Charge. (Technical specification shall be provided in tender documents.) Inspection: Consignee Inspection charges: Borne by Railways Payment terms:100% after supply | — | — | — | 1,97,325.1 | |
| — | 1.00 | — | — | ||
| Installation, testing and commissioning of Failure Analysis System (FAS) as per Technical Specifications. The specification of FAS should be got approved from the Engineer in charge before supply. Note: The Specification of FAS shall be as per technical specification given in contract Agreement or higher version as approved by Engineer In-Charge. (Technical specification shall be provided in tender documents.) Inspection: Consignee, Inspection charges: None Payment terms:100% after commissioning | — | — | — | 49,331.27 | |
| — | 1.00 | — | — | ||
| Supply of 750 VA Off line UPS with battery backup 3 Hours for Failure Analysis System of reputed make of Emerson/APC or superior as per Engineer in-charge. Inspection: Consignee, Inspection charges: None Payment terms:100% after supply | — | — | — | 31,591.88 | |
| — | 8.00 | — | — | ||
| Relay fail safe electronic time delay device with fixed timing (0 @ 45<41@ seconds and conforming to RDSO Specn.No.IRS:S-61/2000 with Amnd.1 or latest mounted on Q-series relay base & covered complete with connectors, retaining clip etc. The interlocking code for this unit shall be "AFHKY". Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply. | — | — | — | 20,160.16 | |
| — | 110.00 | — | — | ||
| Q-Series Neutral Line Relay (QN1 Type), 12F/4B, 24V DC complete with plug board (base plate), connectors and retaining clips etc and conforming to BRS- 930 and RDSO Specn.No.IRS:S-34 & S-23 or latest. The interlocking code for this unit shall be "ABCDE". Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply. | — | — | — | 5,22,067.7 | |
| — | 100.00 | — | — | ||
| Q-Series Neutral Line Relay (QN1 Type), 8F/8B, 24V DC complete with plug board (base plate), connectors and retaining clips etc and conforming to BRS- 930 and RDSO Specn.No.IRS:S-34 & S-23 or latest. The interlocking code for this unit shall be "ABCDF". Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply. | — | — | — | 4,56,051 | |
| — | 90.00 | — | — | ||
| Q-Series Twin Neutral Line Relay (QNN1 Type), 6F/2B, 24V DC complete with plug board (base plate), connectors and retaining clips etc and conforming to BRS-960 and RDSO Specn.No.IRS:S-34 & S-23 or latest. The interlocking code for this unit shall be "ACDEK". Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply. | — | — | — | 5,39,986.5 | |
| — | 100.00 | — | — | ||
| Q-Series Twin Neutral Line Relay (QNN1 Type), 4F/4B, 24V DC complete with plug board (base plate), connectors and retaining clips etc and conforming to BRS-960 and RDSO Specn.No.IRS:S-34 & S-23 or latest. The interlocking code for this unit shall be "ACEHJ". Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply. | — | — | — | 4,73,938 | |
| — | 60.00 | — | — | ||
| Q-Series Magnetically Latched Neutral Line Relay (QL1 Type), 11F/4B,24V DC complete with plug board (base plate), connectors and retaining clips and conforming to BRS-935A and RDSO Specn.No.IRS:S-34 & S-23 or latest. The interlocking code for this unit shall be "ABDEG". Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply. | — | — | — | 4,11,702 | |
| — | 105.00 | — | — | ||
| Q-Series LED ECR (Universal Type i.e. QECX-61), 4F/4B complete with plug board (base plate), connectors, retaining clips etc and conforming to BRS:941A STS/E/RELAYS/AC LIT LED SIGNAL/09-2002, Amdt.-1 and RDSO Specn.No.IRS:S-34 & S-23 or latest. The interlocking code for this unit shall be "ABDHK". Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply. | — | — | — | 6,29,756.4 | |
| — | 125.00 | — | — | ||
| Q-Series Line Relay (QNA1 Type), AC immunized, 8F/8B, 24V DC along with plug board (base plate), connectors, retaining clips etc and conforming to BRS-931A and RDSO Specn.No.IRS:S@ 45"44@ S-23 and S-60 or latest. The interlocking code for this unit shall be "ABDGH". Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply. | — | — | — | 5,88,762.5 | |
| — | 115.00 | — | — | ||
| Q-Series Line Relay (QNA1 Type), AC immunized, 12F/4B, 24V DC along with plug board (base plate), connectors, retaining clips etc and conforming to BRS-931A and RDSO Specn.No.IRS:S@ 45"44@ S-23 and S-60 or latest. The interlocking code for this unit shall be "ABDFH". Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply. | — | — | — | 5,26,690.8 | |
| — | 35.00 | — | — | ||
| Q-Series Track Relay (QTA2 Type), AC immunized, 9 Ohms, 2F/1B along with plug board (base plate), connectors, retaining clips etc and conforming to BRS:939A & 966(Appendix F2) or latest. The interlocking code for this unit shall be "FGHKX". Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply. | — | — | — | 1,57,314.85 | |
| — | 50.00 | — | — | ||
| Q-Series Neutral Line Relay (QSPA1 Type), 24V DC,8F/4B along with plug board (base plate), connectors, retaining clips etc and conforming to BRS-933A and RDSO Specn.No.IRS:S@ 45"44@ S-23 & S 60 or latest. The interlocking code for this unit shall be "ABDEJ". Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply. | — | — | — | 3,13,588.5 | |
| — | 8.00 | — | — | ||
| Key Lock Relays (KLCR), 24 V DC, 2F/2B as per RDSO No. IRS:S-46, S-34 &S-23 or latest. Details of ward plates KLCR of all wards manufactured by firm except I and X preferably in equal number are required. Firm shall supply 2 nos. of ward plates extra with each relay in the metallic enclosure. Inspection: - For bare relay -RDSO, for key lock housing- consignee Inspection charges: -Borne by Railways Payment Terms: - 100% after supply. | — | — | — | 76,687.04 | |
| — | 30.00 | — | — | ||
| Contactor Unit (QBCA1 Type), 24 V DC, 2HF/4B complete with plug board (base plate), connectors, retaining clips etc and conforming to BRS- 943 and RDSO Specn.No.IRS:S-34 & S- 23 or latest. The interlocking code for this unit shall be "BCEJK". Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply. | — | — | — | 2,55,623.4 | |
| — | 897.00 | — | — | ||
| Fixing of Q series relay base plate/metal to metal relay mini group and major group base plate, laying, bunching, lacing, dressing & packeting of 60/40 core PVC indoor cable/flexible wire and termination of 60/40 core cable/flexible wire on tag block/base plate & base plates & soldering. This includes fuse wiring, bus bar looping etc. required for keeping installation ready for circuit wiring work & panel troughing work. The work shall be done as per approved plan, extant practice on NWR & the instruction of Rly. Engineer at site. Inspection: - Consignee Inspection charges: - None Payment Terms: - 100% after execution | — | — | — | 4,21,419.57 | |
| — | 60.00 | — | — | ||
| Sealing wire used for sealing of signalling relays & equipments. Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply. | — | — | — | 12,655.8 | |
| — | 25.00 | — | — | ||
| Supply of QNNA1, AC immunized relay 24V DC, 4F-4B/6F-2B contacts, along with plug board, retaining clip and connectors. Conforming to BRS: 960, IRS: S60, IRS: S34 & IRS: S23. (No of each configuration will be decided by Engineer In-charge). Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply. | — | — | — | 1,50,990 | |
| — | 6.00 | — | — | ||
| Supply of PVC insulated multi strand, single core copper conductor of size 16/0.2 mm (0.5sqmm) as per IS 694:2010 and RDSO Specn.No.IRS:S-76/89 (Amnd-3) or latest. Each coil should be of 100/200/500 meters length. Colour of the wire which is required will be specified by the Engineer incharge. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | — | — | — | 41,977.56 | |
| — | 4.00 | — | — | ||
| Supply of indoor PVC jumper wire (1x 0.6 mm) of all colours as per RDSO Specn.No.IRS:S-76/89 (Amnd.3) or latest. Note: wires colours will be specified/decided by site Engineer incharge. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | — | — | — | 11,617.24 | |
| — | 4.00 | — | — | ||
| Supply of Powder Coated Relay Racks as per Drg. No. CSTE/ S&T/SOR/01 with scaffolding and suitable grouting arrangements. The relay racks shall be supplied & completed with scaffolding, bus bars, fuse strips, fuses (G/NDT), fuse bases, resistors, capacitors, insulators and 200- Way tag blocks with poly carbonate covers, grouting bolts, tripods etc. It includes supply of Tag Blocks as per RDSO Specn.No.IRS:S-77/2006 (Rev.1) or latest and RDSO Drg.No.SA-24751. The top of relay racks will be supported through an angle iron with one side fixed on supporting wall. Inspection: (i) RITES if value of item in work more than 10 lakhs (ii) Consignee Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | — | — | — | 2,23,340.92 | |
| — | 4.00 | — | — | ||
| Erection of Powder Coated Relay Racks as per Drg. No. CSTE/ S&T/SOR/01 with scaffolding and suitable grouting arrangements. The relay racks shall be completed with scaffolding, bus bars, fuse strips, fuses (G/NDT), fuse bases, resistors, capacitors, insulators and 200-Way tag blocks with poly carbonate covers, grouting bolts, tripods etc. It includes fixing of Tag Blocks as per RDSO Specn.No.IRS:S-77/2006 (Rev.1) or latest and RDSO Drg.No.SA-24751. The top of relay racks will be supported through an angle iron with one side fixed on supporting wall. After installation of relay racks, one coat of paint will be done by contractor before fixing the fuses. Scaffolding should include 1 relay rack position as spare at every Station/ Level Crossing Gate for future expansion. Inspection: Consignee Inspection Charges: None Payment Terms: 100% on execution | — | — | — | 55,835.24 | |
| — | 5.00 | — | — | ||
| Supply of Cable Termination (CT) racks as per Drg. No. CSTE/S&T/SOR/02 complete along with fitting arrangements and also with arrangement for fixing four 8-way terminal strips/ Screw less terminals/ ARA terminals on each row having 16 such rows. Supply of 8 way terminal strips/ Screw less terminals / ARA terminals not covered under this item. Cable termination rack shall be Powder Coated. Inspection: (i) RITES if value of item in work more than 10 lakhs (ii) Consignee if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | — | — | — | 1,36,792.3 | |
| — | 5.00 | — | — | ||
| Installation of Cable Termination Racks assembly complete including wall supports, scaffolding and suitable grouting arrangements with installation of 8 way/ARA terminals /Screw less connectors, Tag blocks & other necessary accessories etc. The work shall be done as per approved plan, extant practice on NWR & the instruction of Rly engineer at site. Inspection: Consignee Inspection Charges: None Payment Terms: 100% on Commissioning. | — | — | — | 52,274.75 | |
| — | 11000.00 | — | — | ||
| Supply of ARA Terminal Block (M-6) made of PBT/Poly Carbonate as per RDSO Specn.No.IRS:S-75/2006 (Rev.2) or latest and RDSO Drg. No. SA-23741A (Alt. 4) or latest. Inspection: RDSO. Inspection Charges: Borne by Railways. Payment Terms: 100% on supply. | — | — | — | 11,57,200 | |
| — | 220.00 | — | — | ||
| Supply of Cartridge Fuse Block made of PBT and as per RDSO Drg. No. SA-23748 (Alt. 4) or latest and RDSO Specn.No.IRS:S-75/2006 (Rev.2) or latest. Inspection: RDSO. Inspection Charges: Borne by Railways. Payment Terms: 100% on supply. | — | — | — | 40,504.2 | |
| — | 2.00 | — | — | ||
| Supply of PVC insulated Railway Signalling multi-core Indoor Cable 60core (0.6mm Dia) conforming to IRS:76/89(Amd3) or latest. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs(ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | — | — | — | 3,71,745.7 | |
| — | 17000.00 | — | — | ||
| Termination of Outdoor Cables (Main Cables /tail cables) at both ends in location boxes, cable termination rack in relay room, station building, generator room etc. The item includes dressing of cables and wires with dressing threads as per standard practice. All material required for this item will be supplied by contractor. The outdoor cable shall be terminated in Relay Room, DG Room, ASM Room etc under supervision and instructions issued by Engr. incharge of the work. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after execution | — | — | — | 1,73,060 | |
| — | 3.00 | — | — | ||
| Supply of PVC insulated Railway Signalling multi-core Indoor Cable 24 core (1 mm Dia) conforming to IRS:76/89(Amd3) or latest. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | — | — | — | 5,74,576.86 | |
| — | 1700.00 | — | — | ||
| Supply of Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004(Modular Terminal Blocks, Fuse Terminal Blocks &Miniature fuse link of international standard for Railway signaling) With latest amendments. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply Supply of Disconnect Terminal Block, Screw less type, 4-wire front entry (Two in-put & Two out-put) The colour will be decided by Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3) | — | — | — | 1,11,775 | |
| — | 750.00 | — | — | ||
| Supply of Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004(Modular Terminal Blocks, Fuse Terminal Blocks &Miniature fuse link of international standard for Railway signaling) With latest amendments. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply Supply of End plate for above item (04012601) 2.5mm/0.091 in thick as per site requirement. | — | — | — | 9,240 | |
| — | 350.00 | — | — | ||
| Supply of Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004(Modular Terminal Blocks, Fuse Terminal Blocks &Miniature fuse link of international standard for Railway signaling) With latest amendments. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply Supply of End Stopper for above item (04012601) 10mm/0.0394 in width as per site requirement. | — | — | — | 4,312 | |
| — | 160.00 | — | — | ||
| Supply of Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004(Modular Terminal Blocks, Fuse Terminal Blocks &Miniature fuse link of international standard for Railway signaling) With latest amendments. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply Supply of Carrier Rails for above item (04012601) 35mm x 7.5mm, 1mm/0.039 in thickness un-slotted type as per site requirement. | — | — | — | 20,600 | |
| — | 350.00 | — | — | ||
| Supply of Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004(Modular Terminal Blocks, Fuse Terminal Blocks &Miniature fuse link of international standard for Railway signaling) With latest amendments. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply Supply of Markers strip for above item (04012601) | — | — | — | 6,709.5 | |
| — | 19.00 | — | — | ||
| Supply of Fuse auto changeover system for used in Railway Signalling System as per RDSO/SPN/209/2012 rev.1 with latest amendments. One Automatic changeover Unit comprise 32 nos. of external Non-Deteriorating Type or 'G' type fuses from 0.6 Amp to 4 Amp capacities which are in signalling circuits. System shall have 8 cards with monitoring arrangement of 4 fuses in one card. Inspection:(i) RDSO/RITES: if value of item in work more than 10 lakhs (ii) Consignee: subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs or as per extant policy. Inspection charges:(i) Borne by Railways (ii) None Payment Terms: 100% after supply. | — | — | — | 6,69,476.78 | |
| — | 7.00 | — | — | ||
| Supply of Fuse auto changeover system for used in Railway Signalling System as per RDSO/SPN/209/2012 rev.1 with latest amendments. One Automatic changeover Unit comprise 24 nos. of external Non-Deteriorating Type or 'G' type fuses from 4 Amp to 10 Amp capacities which are in signalling circuits. System shall have 6 cards with monitoring arrangement of 4 fuses in one card. Inspection: (i) RDSO/RITES: if value of item in work more than 10 lakhs (ii) Consignee: subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs or as per extant policy. Inspection charges: (i)Borne by Railways (ii) None Payment Terms: 100% after supply. | — | — | — | 4,06,777.21 | |
| — | 26.00 | — | — | ||
| Installation wiring testing and commissioning of Fuse change over system (FACS). This includes provision of common Buzzer & indication at ASM Room & ESM Duty Room and painting of fuse details. This also includes fabrication of frame for installation of FACS at Station/ LC gate where installation of relay racks not feasible. Inspection: Consignee Inspection charges: None Payment Terms: 100% on commissioning | — | — | — | 27,706.38 | |
| — | 1.00 | — | — | ||
| Installation, Wiring and testing of Integrated Power Supply System. This includes power distribution connection to bus bars and relay racks in the room with contractor's own wiring materials and fabrication and fixing of AC/DC power distribution board made on 10mm thick Phenolic hylam sheets or any standard make with connections suitable for 32 A. Wiring to be done considering site requirement, depending upon the load with suitable wires, lugs & glands as per instructions of Engineer-in-charge. The work includes installation of Thermo flasher relay, ELD's, fixing & wiring of change over switch (program switch) for selection of DG set supply (DG1 & DG2) and wiring of change over switch (program switch) for selection of mains or DG supply. This item also includes supply & fixing of ladder along the wall for carrying power supply wires/cables from IPS room to Relay room/power room etc. Any masonry work required will be carried out by contactors own material. It includes transportation of IPS from consignee depot to work site/station/ LC gate. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after execution For Station | — | — | — | 1,24,501.93 | |
| — | 1.00 | — | — | ||
| Supply of Self-Regulating Type Battery Charger,230V AC/24V DC,30 Amps as per RDSO Specn.No.IRS:S-86/2000 (Amnd.4) or latest. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% on Supply | — | — | — | 57,693.09 | |
| — | 260.00 | — | — | ||
| Supply of uncharged Low Maintenance Lead Acid (LMLA) secondary cell, shelf mounting type conforming to RDSO Specn.No.IRS:S-88/2004 or latest with inter cell connectors, nuts and bolts etc. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after Supply. 2V, 80AH | — | — | — | 6,47,075 | |
| — | 13.00 | — | — | ||
| Supply of uncharged Low Maintenance Lead Acid (LMLA) secondary cell, shelf mounting type conforming to RDSO Specn.No.IRS:S-88/2004 or latest with inter cell connectors, nuts and bolts etc. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after Supply. 2 V, 200AH | — | — | — | 88,638.94 | |
| — | 230.00 | — | — | ||
| Charging of Lead Acid Batteries with contractors own battery grade sulphuric acid and distilled water with minimum two charge - discharge cycles, installation of charged batteries in groups & their connection & wiring. The work shall be done as per extant practice of N.W.Rly & instruction of Engineer-in-charge. Detailed measurements of initial charging shall be recorded jointly by contractor & Rly's site-in-charge. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Execution. 2V, 80AH | — | — | — | 1,02,699.6 | |
| — | 12.00 | — | — | ||
| Charging of Lead Acid Batteries with contractors own battery grade sulphuric acid and distilled water with minimum two charge - discharge cycles, installation of charged batteries in groups & their connection & wiring. The work shall be done as per extant practice of N.W.Rly & instruction of Engineer-in-charge. Detailed measurements of initial charging shall be recorded jointly by contractor & Rly's site-in-charge. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Execution. 2V, 200AH | — | — | — | 14,233.92 | |
| — | 1.00 | — | — | ||
| Installation, wiring, testing and commissioning of Diesel Generator Set 20 KVA, Single Phase, 240V, 1500 RPM, 50 Hz, 30 BHP (minimum) mounted with air cooled double cylinder diesel engine with acoustic enclosure complete silent type DG sets confirming to RDSO Spec. No. IRS(S) 69/86 with latest. (CPCB Noise and Emission Complaint) Kirloskar make engine/alternator. This also includes supply of standard AMF control panel, supply of 12V/120 AH battery set along with battery charger of suitable rating for charging the batteries to ensure self-starting arrangement of DG sets. It also includes supply of start/stop buttons, Volt/Ampere/Frequency meters and 63 AMP MCB (minimum). Note: DG set will be procured from OEM or authorized dealer of OEMs with the warranty certificate of minimum 1 year. All masonry work required for installation of DG set will be done by contractor under supervision/instructions issued by site engineer incharge. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Commissioning | — | — | — | 1,16,755.7 | |
| — | 1.00 | — | — | ||
| Supply of active lightening arrester of Class A for building protection as per standard NFC-17-102. It shall work on early streamer emission principle & shall be made of stainless steel with a T of 60 microseconds. Non resettable type counter shall also be supplied to count the number of lightening occurrences. It also includes supply of electrolytic copper tape of 25mmX2mm or better for connecting class A device to the earth pit. This includes installation, testing and commissioning of Class A device on the top of the building. This device shall be installed at suitable height on the roof of the building using a GI mast as per instructions of Railway engineer at Site. The device shall be connected to earth pit using a copper tape of 25mm x 2mm or better. This copper tape shall be run firmly only the site of the mast with the help of spacers. It shall also be ensured that the down conductor shall not touch the building throughout. the down conductor shall be connected to the earth electrode using exothermic welding. A counter shall be installed at appropriate space to count the number of occurrences. All the accessories like spacers, welding material etc. required for installation shall be arranged by the contractor. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after commissioning. | — | — | — | 80,624.99 | |
| — | 2.00 | — | — | ||
| Supply of maintenance stand for relay room / battery room as per samples /drawings approved by the site engineer incharge. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after supply. | — | — | — | 5,754.28 | |
| — | 45.00 | — | — | ||
| Supply of Insulation Rubber Mat for electrical purpose 2.5mm thick size 2m*1m suitable for 3.3KV to 11KV (Class B) conforming to IS I5652-2006 Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Supply. | — | — | — | 4,814.1 | |
| — | 23.00 | — | — | ||
| Supply of Electric Point Machine 143 mm stroke AC immunity 160V AC complete with lock detector and slides for lock detector non -trailable to operate on 110V DC rotary locking with crank handle universal type as per RDSO Spec. No. IRS:S-24/2002 (Amnd 1) RDSO Drg. No. S-10800 (Alt.5) with junction box telescopic. The motor will be as per RDSO Spec. No. IRS: S-37/82 (Amnd. 3) with RDSO Drg. No. S-10910. This includes supply of Set of tools as per para 20.1 & 20.2 of RDSO SPECN. NO. IRS:S-24/2002 (Amnd 1) 20.1 The following set of tools in a suitable tool box shall be supplied along with every set of eight point machines or less. i) Hand operated square drive socket wrenches of 12.5 mm driving square (short type) as per IS: 7381 for M8, M10, M12 & M18 threads. (One 250 mm long 12.5 mm square extension bar as per IS: 7991 alongwith compatible Tee handle Square drive as per IS: 7975 suitable for above socket wrenches shall also be provided.) ii) Open jaw wrenches (spanners) for M10, M12, M20, M24 & M33 threads as per IS: 2028. iii) Adjustable wrench. iv) Screw driver 300 mm long. 20.2 Junction box and two numbers of telescopic pipes of approved type shall be supplied as an integral part of the point machine. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after Supply. | — | — | — | 16,72,239.84 | |
| — | 2.00 | — | — | ||
| Supply of Electric Point Machine 143 mm stroke AC immunity 400V AC complete with lock detector and slides for lock detector non -trailable to operate on 110V DC rotary locking with crank handle universal type as per RDSO Spec. no. IRS:S-24/2002 (Amnd 1) RDSO Spec. no S-10800 (alt.5) with junction box telescopic. The motor will be as per RDSO Spec. no. IRS: S-37/82 (amnd. 3) with RDSO Spec. no. S-10910. This includes supply of Set of tools as per para 20.1 & 20.2 of RDSO Spec. no. IRS:S-24/2002 (Amnd 1). 20.1 The following set of tools in a suitable tool box shall be supplied along with every set of eight point machines or less. i) Hand operated square drive socket wrenches of 12.5 mm driving square(short type) as per IS: 7381 for M8, M10, M12 & M18 threads. (One 250 mm long 12.5 mm square extension bar as per IS: 7991 alongwith compatible Tee handle square drive as per IS: 7975 suitable forabove socket wrenches shall also be provided.) ii) Open jaw wrenches (spanners) for M10, M12, M20, M24 & M33 threads as per IS: 2028. iii) Adjustable wrench. iv) Screw driver 300 mm long. 20.2 Junction box and two numbers of telescopic pipes of approved type shall be suppliedas an integral part of the point machine. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after Supply. | — | — | — | 1,74,387.16 | |
| — | 25.00 | — | — | ||
| Fixing, wiring, testing and commissioning of Electrical Point Machine on the extended sleepers at points as per std. practice and as per RDSO Drg No. SA 9151-52 or 9710 or 9161 or 10800 or 11000 as per section of rails used. Item includes fixing switch extension bracket, providing insulation for switch extension bracket, fixing ground connection, adjusting opening of the switches and adjusting the point machine with crank handle. The item also includes : (i) Complete material for installation like point insulation material, I pipes, wiring materials, various fixing nuts & bolts including castle nuts, spring washers (ii) All smithy & fitting works required at site for complete installation. (iii) Installation of gauge tie plate & providing insulation for gauge tie plate (Insulation in William Stretcher Bar will be Provide by Railways). (iv) Wiring inside the point machine, insertion and termination of tail cable in point machine and junction boxes / location box /cable hut as per extent practice on NWR and the instruction of Railway Engineer at site. (v) Supply and fixing of suitable size GI pipes with flange for taking cable into point machine. Note ; Electrical Point Machine and M-6 / Screw less terminals will be supplied by Railways / covered in Schedule separately. Inspection: Consignee Inspection charges: Borne by Railways Payment terms: 90% after Installation & 10% after commissioning. | — | — | — | 4,19,657 | |
| — | 25.00 | — | — | ||
| Gauge Tie plate insulations per RDSO/SPN/168/2005 as per RDSO drg No: T- 10372Alt2, T- 10368, T- 10371 Alt. 2, T-15083/88/Alt2 & T-11690/Alt2 and as per RDSO/SPN/168/2005 with latest amendments as applicable. Gauge tie plates (52 Kg/60Kg as per site requirement) Insulation for (BG) complete with insulating bush and washereach set comprising of: (a) Insulating plate for insulated tie plate BG as per RDSO Drg. No. T-10372-1 No. (b) Insulating bushing for insulated stretcher bar BG as per RDSO Drg. No. T10368 - 3 Nos. (c) Insulating Washer for insulated stretcher bar BG to IRS 40/84 as per RDSO drg. No. T-10371 - 6 Nos. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | — | — | — | 34,790.5 | |
| — | 24.00 | — | — | ||
| Ground connections, complete set suitable for IRS type / approved point Machine for ordinary turnout with tongue attachment insulation and other insulation as per RDSO Drg. S/3361@ 47>47@ 63 (for IRS type point machine) or RDSO Drg No.SA-9151/52 (for Siemens point machine) with latest amendments. However, the ground connection shall be procured only after confirmation from Railway engineer as per site condition /type of machine/turnout. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | — | — | — | 1,97,270.16 | |
| — | 13.00 | — | — | ||
| Ground connections, complete set suitable for IRS type/approved point Machine for derail switch with tongue attachment insulation as per RDSO Drg. S/3361@ 47>47?40@for IRS type point machine) or RDSO Drg No. SA 9151/52 (for Siemens point machine) with latest amendments. However the ground connection shall be procured only after Confirmation from Railway engineer as per latest site condition /type of machine/turnout. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | — | — | — | 91,488.02 | |
| — | 31.00 | — | — | ||
| Supply of William Stretcher Insulation Set (complete) as per RDSO/SPN/168/2005 with insulating bush and washer to suit point layout and conforming to RDSO Drg.No.T-10372 or latest, T- 10368 or latest and T-10371 or latest. 1.1 Insulation for Leading stretcher bars(BG) each set comprising of: (a) Insulating plate for leading insulated stretcher bars BG as per RDSO Drg.No.T- 10384 - 2 Nos. (b) Insulating bushing for leading insulated stretcher bars for BG as per RDSO Drg.No.T-10535- 4 Nos. (c) Insulating Washer for insulated stretcher bar BG as per RDSO drg.No.T- 10371 - 6 Nos. 1.2 Insulation for following stretcher bars BG. Each set comprising of: (a) Insulating side plate for insulated stretcher bars BG as per RDSO Drg.No.T-10367 - 3 No. (b) Insulating bushing for insulated stretcher bars BG as per RDSO Drg.No..T-10368 - 6 Nos. (c)Insulating washer for insulated stretcher bars BG as per RDSO Drg.No.T10371 - 12 Nos Inspection: (i) RITES if value of item in work more than 10 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | — | — | — | 14,406.01 | |
| — | 49.00 | — | — | ||
| Supply of Track feed Battery Charger as per RDSO Spec. No. IRS: S-89/2013 Ver.1.0 or latest. Charging Capacity Rating 10 Amps for Charging 80 AH Battery. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after Supply | — | — | — | 2,65,673.59 | |
| — | 51.00 | — | — | ||
| Supply of Adjustable Track Feed Resistance 30 Ohms (Disc Type) as per RDSO Drg. No.SA-20161-66/M or latest. Inspection: RDSO Inspection Charges: None Payment Terms: 100% after Supply. | — | — | — | 88,334.04 | |
| — | 49.00 | — | — | ||
| Fixing and wiring of DC track circuit equipments i.e. track feed charger, resistance, track relay, battery, B type choke etc., in the Apparatus Case and battery box as per standard practice. Termination of tail cable on M 6 / Screw less terminals WAGO or FINOLEX or similar approved make terminals/ fuse blocks / HRC fuse. Item includes testing /commissioning of track circuit. Complete wiring material will be supplied by contractor. (Supply of Track feed battery charger, track feed battery, resistances & 'B' type choke & Track relays, ARA terminal/Modular terminals Wago/phoenix contact type will be supplied by Railways / covered in Schedule separately). Inspection: Consignee Inspection Charges: None Payment Terms: 100% after execution. | — | — | — | 3,74,705.45 | |
| — | 49.00 | — | — | ||
| Installation of DC track circuits covering all types of Track circuits including points zones also. The item includes provision of doubled continuity GI wire bonds on rail joints after drilling bond-hole of 7.0/7.2 mm Dia, skimming of fish plate, insertion of insulated block joint( if required), fixing of TLJB (separate for positive & negative rails) with angle iron for track feed/jumper/track relay ends of track circuits and also for fixing jumper cables as per approved Track Circuit Plan, making rail connections through suitable insulated sleeves from TLJB at TF, jumper & TR end with GI wire, rail clips for fixing bond wire on the TLJB as per standard practice, termination of tail cables on TLJB terminals etc. TF/TR wiring shall be fixed on the suitable arrangement on PRC sleepers with the help of Hooks. In case Engineer at site desires that jumpering from TLJBs is to be done using signalling cable 2 core X 2.5 sq. mm, contractor shall provide the jumpering cable using 2 X 2.5 sq. mm signalling cable. The signalling cable will be supplied by Railways. Hooks shall be provided on PRC sleepers with the help of suitable steel bracket. This item also includes fixing & supply of channel pins, Hooks etc. The item does not include includes supply of TLJB as per RDSO Drg. No. RST-11509 or latest as per technical specs Installation of Track Lead Junction Box (TLJB) as per Drg.No.RST- 11509 or latest made from FRP material including brass bolts and hylam board sheet with terminals etc. (a) Installation and commissioning of TLJB complete with cover to be in black/red having approximate weight of 4.0 Kg with L-262mm W-212mm and H 90 mm and all the holes required for mounting on FRP stump (vertical two for each FRP angle) HDPE pipe, cable etc. (b) Installation and commissioning of Each TLJB having two Bakelite terminal block fitted horizontally: each Bakelite terminal block shall have two nickel chrome plate M10 brass terminal, 50mm long. Along with each TLJB, nickel chrome plated brass links (two nos.0f adequate strength for vertical linking of the terminals to be wired and fixed properly. (c) Installation of HDPE pipe of size 32/35mm, 380 mm long along with two nuts for fixing on the TLJB hole. (d) Installation of the FRP stump for mounting the TLJB to be made of one-meter long 30mm X30mmX 4mm angle (2 nos.) and 300mm long 30mm X30mmX 4mm angle (1 no.) fixed at 50 mm from the bottom using galvanised nuts and bolts. The TLJB and the angles for stump should be fixed in given holes on them for fixing using galvanised nuts and bolts. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after execution. | — | — | — | 4,68,994.68 | |
| — | 340.00 | — | — | ||
| Supply of Track Lead Junction Box (TLJB) as per Drg.No.RST-11509 or latest made from FRP material including brass bolts and hylam board sheet with terminals etc. The technical specifications are as follows: (a) TLJB complete with cover to be in black/red having approximate weight of 4.0 Kg with L-262mm W-212mm and H 90 mm and all the holes required for mounting on FRP stump (vertical two for each FRP angle) HDPE pipe, cable etc. (b) Each TLJB shall have two Bakelite terminal block fitted horizontally: each Bakelite terminal block shall have two nickel chrome plate M10 brass terminal, 50mm long. Along with each TLJB, nickel chrome plated brass links (two nos.0f adequate strength for vertical linking of the terminals to be supplied. (c) HDPE pipe of size 32/35mm, 380 mm long alongwith two nuts for fixing on the TLJB hole. (d) The FRP stump for mounting the TLJB to be made of one-meter long 30mm X30mmX 4mm angle (2 nos.) and 300mm long 30mm X30mmX 4mm angle (1 no.) fixed at 50 mm from the bottom using galvanised nuts and bolts. The TLJB and the angles for stump should come alongwith holes on them for fixing using galvanised nuts and bolts of adequate strength to be supplied alongwith TLJB drawing no. 11509. Inspection: (i) RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | — | — | — | 7,27,702 | |
| — | 340.00 | — | — | ||
| Erection, Fitting and Rail connection of Track Lead Junction Box on two supports (FRP stumps) with contractor's fixing material. This will include drilling of holes for track lead/side connections on rail. The work shall be done as per instructions of Rly engineer at site. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after execution. | — | — | — | 5,38,345.8 | |
| — | 98.00 | — | — | ||
| Supply of B Type Choke as per RDSO Specn.No.IRS:S-65/83 (Amnd. 1) or latest. Inspection: RDSO Inspection Charges: Borne by Railways. Payment Terms: 100% after supply. | — | — | — | 4,83,440.86 | |
| — | 12000.00 | — | — | ||
| Supply of Channel Pins MS (Galvanized) single groove, 7 mm suitable for 4mm Dia bonding wire as per spec No IRS S 17 & RDSO Drg No. S-69/M. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Supply. | — | — | — | 82,200 | |
| — | 60.00 | — | — | ||
| Supply of GI wire 8 SWG (4mm Dia) suitable for track circuit rail bonding. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Supply. | — | — | — | 4,766.4 | |
| — | 230.00 | — | — | ||
| Provision/Installation of bonding with GI wire 4mm Dia (8 SWG) for track jumper & fish plate joints bonds. This will include drilling of 7.0/7.1/7.2 mm Dia holes in rails (4 Nos.) and provision of two jumpers for each bond, clipping of bonds etc. with contractors own tools as per instruction of Rly. Engineer at site. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Execution. | — | — | — | 49,774.3 | |
| — | 3.00 | — | — | ||
| Supply of hand operated track drilling machine for bonding hole. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after supply. | — | — | — | 29,068.65 | |
| — | 2.00 | — | — | ||
| Supply of Microprocessor based Solid State Block Proving by Axle Counter (Digital) [SSBPAC(D)] complete for Single line operation as per RDSO Spec. No. RDSO/SPN/175/2005Ver.1 or latest including Station Master's Block Panel, Wired Relay Racks with Relays, necessary Lightening & Surge Protection Devices for Power Lines 24V DC & Data Lines and Block Telephone as per RDSO/SPN/191/2005 or latest (Per Unit = Set Per Block Section). Inspection: RDSO Inspection Charges: Borne by Railways. Payment Terms: 100% after Supply. | — | — | — | 25,52,544 | |
| — | 2.00 | — | — | ||
| Installation, Testing and commissioning of SSBPAC(D) complete including Station Master's Block panel and Automatic Media Changeover Card for Single line operation a s per RDSO Spec. No. RDSO/SPN/175/2005 Ver.1 or latest. [All miscellaneous items required for commissioning shall be supplied by contractor] (Per Unit = Set Per Block Section) Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after commissioning. | — | — | — | 1,13,380 | |
| — | 2.00 | — | — | ||
| Supply of Automatic Media changeover Card for SSBPAC(D) which includes One Voice Modem Circuit and O n e E 1 Converter Circuit, for working on redundant channels f o r data transmission on OFC/ Quad. Necessary Lightning & Surge protection devices for data lines need to be provided. Inspection: RDSO Inspection Charges: Borne by Railways. Payment Terms: 100% after Supply. | — | — | — | 2,28,830 | |
| — | 360.00 | — | — | ||
| Installation and wiring of LED signals lamps for auxiliary/subsidiary signals/main signals (i.e. route, shunt, calling on, Red, Yellow, Green) as per instructions given by engineer incharge. Complete wiring inside the signal unit with 2.5 sq. mm multi strand wire of different colour according to signal aspect with copper lug as per standard practice. The contractor will supply all materials required for installation. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after execution. | — | — | — | 77,504.4 | |
| — | 19.00 | — | — | ||
| Supply of Colour Light Signal Complete. This includes: - (1) Post Tubular 140 mm Dia, as per IRS: S-6/81 or Latest & RDSO Drg. No. SA-24625 (Advance). (2) CI Base (As per IRS S-10 & RDSO Drg. No. 2011/M with latest assembly). (3) Number plate to Drawing No. S 23149 Alt.1 =1 No, Number plate clamps to Drawing No. S 23148 Alt.1 =2 no (4) Ladder Assembly, as per RDSO Drg. No. SA-23156, with Base, Ladder Guard rail (complete) to Drawing No. SA 23138 Alt.1(1No), Platform to Drawing No. SA 23134 Alt.1(1 No), Front Maintenance Platform, MS Supporting bracket to Support Ladder. Ladder stay (small) to Drawing No. S 23159 Alt. 1 (2 Nos.) , Ladder stay (large) to Drawing No. S 23160 Alt. 1 (2 Nos.) , Ladder section to Drawing No. SA 23157 Alt. 1(1 Nos.)Stay clamp to Drawing No. SA 2062/M (2 no), Rail Clamp to Drawing No. S 2066/M (1 No.) (5) Signal Front Staging Complete Assembly for CLS Unit. (6) Signal back staging as per extent NWR Practice. Note: Height of the Post shall be 5.5 Long. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee- if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | — | — | — | 2,46,763.07 | |
| — | 14.00 | — | — | ||
| Supply of Offset brackets for Main Signal, made of tubular steel, outer diameter 140 mm, thickness of pipe 4.5 mm. horizontal length of pipe 545 mm & vertical length of pipe 324 mm with fixing arrangement on Main Signal post as per Drawing No SW/554/G/R. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee- if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | — | — | — | 75,188.54 | |
| — | 7.00 | — | — | ||
| Supply of Offset brackets for Shunt Signal, made of tubular steel, outer diameter 89 mm, thickness of pipe 4.5 mm. horizontal length of pipe 324 mm & vertical length of pipe 324 mm with fixing arrangement on Shunt Signal post as per Drawing No SW/354/I. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee- if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | — | — | — | 36,529.99 | |
| — | 6.00 | — | — | ||
| Erection of CLS Post with base and signal unit on top or on OFFset Bracket, fixing of front and back staging, ladder and guards, signal name plates / boards if any with contractor's own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any. The work shall be done as per instructions of Rly engineer at site. It also includes provision & fixing of maintenance platform as per design given by Engineer -In-Charge at site. The Item includes cutting of Signal post if required by Site In charge. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after installation. 2/3/4 aspect signal unit mounted on offset bracket with junction type route indicator 1/2/3/4/5/6 or multi-lamp lamp route indicators/Stencil type rout indicator mounted on signal post. | — | — | — | 23,306.88 | |
| — | 18.00 | — | — | ||
| Erection of CLS Post with base and signal unit on top or on OFFset Bracket, fixing of front and back staging, ladder and guards, signal name plates / boards if any with contractor's own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any. The work shall be done as per instructions of Rly engineer at site. It also includes provision & fixing of maintenance platform as per design given by Engineer -In-Charge at site. The Item includes cutting of Signal post if required by Site In charge. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after installation. 2/3/4 aspect signal unit mounted directly on signal post. | — | — | — | 47,386.26 | |
| — | 14.00 | — | — | ||
| Supply of Non-Metallic (FRP) colour light signal housing multi-unit type for railway signalling suitable for RE area TWO Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23001/A/M Adv. Alt- S and as per SPEC. No. RDSO/SPN/194/2006 (Rev 2.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee- if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | — | — | — | 4,51,015.88 | |
| — | 8.00 | — | — | ||
| Supply of Non-Metallic (FRP) colour light signal housing multi-unit type for railway signalling suitable for RE area THREE Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23001/A/M Adv. Alt- S and as per SPEC. No. RDSO/SPN/194/2006 (Rev 2.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee- if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | — | — | — | 2,69,995.92 | |
| — | 8.00 | — | — | ||
| Supply of Position Light Shunt Signal Unit Complete with Post (made of GI Pipe of 80 mm Diameter Medium Class IS Spec. No. IS: 1239 Pt. 1/1990, Base, Hood, Cover etc as per Drg. No. SA-23840 suitable for LED Signal Lighting Unit. (Supply of LED Unit is not covered in this item) Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee- if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | — | — | — | 41,376 | |
| — | 8.00 | — | — | ||
| Erection of Position Light Shunt signal with Base, Post, Signal unit and fixing of Number Plates. The work shall be done as per instructions of Rly engineer at site. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after installation. | — | — | — | 17,137.76 | |
| — | 11.00 | — | — | ||
| Supply of Position Light Shunt Signal Unit Complete, with offset bracket, hood, Cover etc as per Drg. No. SA-23840 suitable for LED Signal Lighting Unit. (Supply of LED Unit is not covered in this item) Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee- if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | — | — | — | 44,461.89 | |
| — | 11.00 | — | — | ||
| Erection of Position Light shunt signal on Offset bracket on main signal. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after installation. | — | — | — | 26,050.42 | |
| — | 4.00 | — | — | ||
| Supply of Junction route indicator unit 2 way (Without Lenses & Holder) as per Drg. No. RDSO SA 23402 suitable for LED Signal Lighting Unit & as IRS:S-66/84 amndt-1 or latest.(Supply of LED Unit is not covered in this item) Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee- if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i) Borne by Railways (ii) None Payment Terms: 100% on Supply | — | — | — | 98,640.56 | |
| — | 1.00 | — | — | ||
| Supply of Junction route indicator unit 3 ways (Without Lenses & Holder) as per Drg. No. RDSO SA 23403 suitable for LED Signal Lighting Unit & as IRS:S-66/84 amndt-1 or latest.(Supply of LED Unit is not covered in this item) Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee- if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i) Borne by Railways (ii) None Payment Terms: 100% on Supply | — | — | — | 28,945.94 | |
| — | 5.00 | — | — | ||
| Fixing of Junction type Route Indication 1-Way/2-Way/3-Way/4-Way/5-Way/6-Way on the top of the signal post. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after installation. | — | — | — | 3,554.4 | |
| — | 2.00 | — | — | ||
| Supply of Calling ON Signal Unit with Brackets & Fixing accessories. Calling On Signal Unit shall conform to RDSO Drg no 24351(Adv) Alt1 suitable to LED Signal Lighting Unit. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee- if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i) Borne by Railways (ii) None Payment Terms: 100% on Supply | — | — | — | 6,139.02 | |
| — | 3.00 | — | — | ||
| Fixing of Calling-on Signal/A-Sign/AG-Sign unit on signal post. The item includes fixing of Co- On signal /'A' sign/ 'AG' sign unit on signal post with bracket, hood etc. Item includes supply of bracket & fixing materials etc. by the contactor. The item also includes termination of cables & wiring inside Co- On signal /'A' sign/ 'AG' sign unit as per standard practice. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after installation. | — | — | — | 8,394.9 | |
| — | 5.00 | — | — | ||
| Supply of Stop Board as per RDSO Drg No 7235/B / Block Section Limit Board/Shunting Limit Board as per RDSO Drg. No. SA2375 (Adv.). This includes Painting and retro reflective arrangement should be as per SEM. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after installation. | — | — | — | 12,902.6 | |
| — | 7.00 | — | — | ||
| Supply of Different warning Boards / Calling on Board used for Railway Signalling system as per latest specification. This includes Painting and retro reflective arrangement should be as per IRSEM. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after installation. | — | — | — | 39,070.78 | |
| — | 11.00 | — | — | ||
| Fixing of Stop Board, Block section limit Board, Shunting Limit Board, goods warning board, Calling on Board with contractors own material. This excludes supply of Stop Board / Block section limit Board / Goods warning board/Calling on board. The work shall be done as per instruction of Rly Engineer at site. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after installation. | — | — | — | 4,429.59 | |
| — | 50.00 | — | — | ||
| Supply, Fabrication and fixing of Signal Number Plate 'A' Marker, 'AG' Marker, 'P' Marker, Arrow Marker, 'G' Marker, 'C' Marker as per IRSEM drawings. All material required for this work shall be supplied by Contractor. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after installation. | — | — | — | 73,621.5 | |
| — | 26.00 | — | — | ||
| Supply and fixing of protective screen of expanded metal 12 SWG of size 1200 x 1500 mm on signals as per std. practice in RE Area. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after installation. | — | — | — | 1,59,197.48 | |
| — | 23.00 | — | — | ||
| Casting of CC Foundation for Signal Post in the ratio of 1:3:6 as per Drg. No. CSTE/NWR/SOR/21/A using standard size of foundation/galvanized holding down bolts required for erection of colour light signal post. Item includes excavation, ramming of CC using vibrator, curing and plastering with 1:4 cement-sand mixture (aggregate will not exceed 3.8 cm). Aggregate, cement, sand and holding down bolts will be supplied by contractor. Any machines & tools, if required for execution of this item, will be arranged/provided by contractor. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after installation. | — | — | — | 2,59,130.88 | |
| — | 9.00 | — | — | ||
| Casting of C.C. Foundation for Position Light Shunt Signal/ Indicator/SPI as per Drg. No. CSTE/NWR/SOR/22 in ratio 1:3:6 by using standard size of galvanized holding down/foundation bolts. Item includes excavation, ramming of CC using vibrator, curing and plastering with 1:4 cement sand mixture. Aggregate cement, sand and holding down bolts, will be supplied by contractor. Any machines and tools, if required for execution of this item, will be arranged/provided by contractor. Note: As per available site conditions, if sizes of foundations are required to be decreased/ increased and same has been approved/agreed by engineer incharge then variation in CC work will be calculated on volumetric basis as per rates of these items. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after installation. | — | — | — | 68,349.6 | |
| — | 90.00 | — | — | ||
| Cement concrete work for miscellaneous items in the ratio 1: 3: 6. Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand to be supplied by the contractor)(cum is Cubic Meter). Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution | — | — | — | 3,92,994.9 | |
| — | 1.00 | — | — | ||
| Installation, testing and commissioning of electrically operated lifting barrier, complete with Casting of cement concrete foundation for pedestal and boom rest post, cabling, power supply connection & wiring with complete outdoor work as per approved drawing, wiring etc. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Commissioning | — | — | — | 56,250.98 | |
| — | 2.00 | — | — | ||
| Supply of Dual Tone Bell /Buzzer with Flasher arrangement and 20Watt horn working on 24 V DC/ 110 V AC for warning road users at LC gates. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Supply | — | — | — | 12,489.74 | |
| — | 24.00 | — | — | ||
| Supply, installation testing and commissioning of Heat and smoke multi sensor as per RDSO/SPN/217/2025 ver-3.1 or latest. along with its base, back-box and all accessories incompliance with IS:2175 and IS:11360 standard sand Under writers Laboratory (UL) listed. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after execution. | — | — | — | 1,50,624 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing and commissioning Fault isolator as per RDSO/SPN/217/2025 ver-3.1 or latest with backbox and all other accessories Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after execution. | — | — | — | 12,104 | |
| — | 300.00 | — | — | ||
| Supply of Analogue linear heat sensing (LHS) cable as per RDSO/SPN/217/2025 ver- 3.1 or latest Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after Supply. | — | — | — | 4,26,000 | |
| — | 300.00 | — | — | ||
| Supply of Fire survival cable 2x1.5 sq.mm unarmoured as per RDSO/SPN/217/2025 ver-3.1 or latest Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after Supply. | — | — | — | 48,300 | |
| — | 1.00 | — | — | ||
| Supply, installation, testing and commissioning of Networkable s i n g l e loop addressable Fi r e alarm Control panel expandable up to 4 loops with GSM interface as per RDSO/SPN/217/2025 ver-3.1 or latest. This work involves supply, fixing, installation and testing of control panel. The control panel shall be networkable t o Zonal /Divisional headquarters preferably over TCP/lP and shall have clock synchronization facility. This includes Networking module (TCP/IP) for control panel along with power supply unit and battery set of required capacity for 24 hours backup as per RDSO specification. The panel should support degrade mode operation in compliance with IS: 2189, EN54 standards and Underwriters Laboratory (UL) listed. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after execution. | — | — | — | 2,10,156 | |
| — | 1.00 | — | — | ||
| Supply, installation, testing and commissioning of GSM module for Control panel with backbox and all other accessories as per RDSO/SPN/217/2025ver- 3.1 or latest. with auto dialer function to SMS during failure or fire situation. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after execution. | — | — | — | 34,185 | |
| — | 3.00 | — | — | ||
| Supply, installation, testing and commissioning of Manual call point (resettable) with backbox and all other accessories as per RDSO/SPN/217/2025ver-3.1 or latest Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after execution. | — | — | — | 24,027 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing and commissioning of Relay module with backbox and all other accessories as per RDSO/SPN/217/2025 ver-3.1 or latest. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after execution. | — | — | — | 8,732 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing and commissioning of Hooter and Visual strobe alarm units with backbox and all other accessories as per RDSO/SPN/217/2025 ver-.3.1 or latest along with its power supply unit. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after execution. | — | — | — | 29,214 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing and commissioning of Control module with backbox and a l l other accessories a s p e r RDSO/SPN/217/2025 ver-3.1 or latest. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after execution | — | — | — | 11,222 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing and commissioning of EOL as per RDSO/SPN/217/2025 ver-3.1 or latest as directed by the site engineers Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after execution | — | — | — | 6,978 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing and commissioning of Monitor module for 3rd party with backbox and all other accessories as per RDSO/SPN/217/2025 ver-3.1 or latest. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after execution | — | — | — | 7,172 | |
| — | 10.00 | — | — | ||
| CO2 Fire Extinguisher: Supply, installation, testing and commissioning of CO2 fire extinguisher 6.5kg capacity conforming t o IS15683 w ith I S I mark provided with all fittings and accessories. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after execution | — | — | — | 2,52,670 | |
| — | 300.00 | — | — | ||
| Supply of Fire survival cable 2x 1.5 sq.mm armoured as per RDSO/SPN/217/2025 ver- 3.1 or latest. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after Supply. | — | — | — | 38,100 | |
| — | 1.00 | — | — | ||
| Supply of aspiration-type smoke detector. Highly sensitive smoke aspiration system for monitoring of rooms and equipment for earliest possible fire detection For Relay rooms a s per RDSO spec. No. RDSO/SPN/217/2025 ver3.1or latest. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after Supply | — | — | — | 6,30,843 | |
| — | 1.00 | — | — | ||
| Supply and Installation of Air Sampling CPVC Pipes with all required accessories for the Aspiration System. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after execution | — | — | — | 2,57,648 | |
| — | 1.00 | — | — | ||
| Supervision, Programming, Installation, Testing and Commissioning o f Aspiration Smoke detection Supplied. | — | — | — | 72,212 | |
| — | 10.00 | — | — | ||
| Automatic Fire Ball for Fire-Extinguishing of Medium size - the weight of the agent is not less than 1.0 kg but less than 1.8kg. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after Supply. | — | — | — | 3,910 | |
| — | 5.00 | — | — | ||
| Supply of Steel Plain Almirah with 4 adjustable shelves Size: 1980mm height, 915 mm width and 485 mm depth. Make: Godrej Storewel Plain Large or Similar of reputed brand. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Supply. | — | — | — | 97,913.25 | |
| — | 1.00 | — | — | ||
| Supply of Panel cum Block Instrument table complete as per approved drawing. It includes any modification to it if required by Engineer-in-charge at site. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Supply. | — | — | — | 41,593.78 | |
| — | 25.00 | — | — | ||
| Supply of Apparatus Case Single (Large) NE Rly Type as per Drg. No. CSTE/6088 fitted with two nos of E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376 and Key to Drg. No. 3377 as per RDSO drawing No. RDSO/S-11500. Note: This item includes the supply of 2 Nos E Type Lock fitted on both doors, along with two Keys. Inspection: (i) RITES if value of item in work more than 10 lakhs or as per extant instructions by Railway Board. (ii) Consignee if value of whole item in work less than 10 lakhs or as per extant instructions by Railway Board. Inspection Charges:(i) Borne by Railways (ii) None Payment Terms: 100% after Supply. | — | — | — | 4,49,673.5 | |
| — | 50.00 | — | — | ||
| Installation of Apparatus Cases Single (Large) with 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. Supply of 'E' Type lock has been covered in supply of Apparatus case separately. It covers fixing of lamp holder, switch and lamp etc. in Apparatus Case. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. | — | — | — | 62,527 | |
| — | 17.00 | — | — | ||
| Supply of Apparatus Case half (Medium) NE Rly Type as per Drg. No. CSTE/6088 fitted with two nos of E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376 and Key to Drg. No. 3377 as per RDSO drawing No. RDSO/S-11507. Note: This item includes the supply of 2 Nos E Type Lock fitted on both doors, along with two Keys. Inspection: (i) RITES if value of item in work more than 10 lakhs or as per extant instructions by Railway Board. (ii) Consignee if value of whole item in work less than 10 lakhs or as per extant instructions by Railway Board. Inspection Charges:(i) Borne by Railways (ii) None Payment Terms: 100% after Supply. | — | — | — | 1,93,125.44 | |
| — | 27.00 | — | — | ||
| Installation of Apparatus Cases Half (Medium) with 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. Supply of 'E' Type lock has been covered in supply of Apparatus case separately. It covers fixing of Location lamp holder, switch and lamp etc. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. | — | — | — | 20,562.12 | |
| — | 50.00 | — | — | ||
| Excavation and Casting of Apparatus Case foundation in ratio 1:3:6 with contractor's own materials including cement and galvanized anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. The item also includes additional masonry work as well as earthwork if required on bank where there will be possibilities of foundation sinked, fallen or tilted. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. Single (Large) Case Apparatus case / SS location box as per Drg No. CSTE/5074 | — | — | — | 4,14,540.5 | |
| — | 27.00 | — | — | ||
| Excavation and Casting of Apparatus Case foundation in ratio 1:3:6 with contractor's own materials including cement and galvanized anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. The item also includes additional masonry work as well as earthwork if required on bank where there will be possibilities of foundation sinked, fallen or tilted. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. Half (Medium) Case Apparatus case / SS location box as per Drg No. CSTE/5074 | — | — | — | 1,70,893.8 | |
| — | 25.00 | — | — | ||
| Supply of Phenolic laminated Sheet, grade P3 in standard size of 1220 X 1220 x 20 mm as per spec. No IS 2036 of 1995 or latest. Test report of manufacture to be supplied. Inspection: (i) RITES if value of item in work more than 10 lakhs or as per extant instructions by Railway Board. (ii) Consignee Inspection Charges:(i) Borne by Railways(ii) None Payment Terms: 100% after Supply. | — | — | — | 2,87,740.5 | |
| — | 50.00 | — | — | ||
| Fabrication and fixing of phenolic laminated sheet of size 10/12/20 mm thick in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per instructions of Rly engineer at site. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. Single Case (Large Case) | — | — | — | 1,41,079.5 | |
| — | 27.00 | — | — | ||
| Fabrication and fixing of phenolic laminated sheet of size 10/12/20 mm thick in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per instructions of Rly engineer at site. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. Half Case (Medium Case) | — | — | — | 22,226.13 | |
| — | 400.00 | — | — | ||
| Supply of Round head type non deteriorating type low voltage cartridge fuse as per Spec No IRS/S/78/92 with latest amendments 2A/4A/6A capacity. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after supply. | — | — | — | 28,488 | |
| — | 14000.00 | — | — | ||
| Fixing of ARA(M-6) Terminals /Screw less connectors / modular disconnect terminal blocks and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry. (Supply of all above terminals have been covered separately in Chapter 4 of SOR) Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. | — | — | — | 2,10,980 | |
| — | 250.00 | — | — | ||
| Supply of HRC fuses block complete with 2A fuse link as per IS 9224/79 Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after supply. | — | — | — | 19,175 | |
| — | 18.00 | — | — | ||
| Fixing of KLCR relays in field in half location boxes if Gate lodge is not provided or at any other location as decided by engineer in charge. Item includes supply and fixing of MS sheet and wiring of KLCR relays, push buttons and LEDs for KLCR circuit. The KLCR relays, push buttons, LEDs will be fixed on a MS sheet of min. 3mm in the half location box. The MS sheet will cover full length and breadth of the half location box and divided in two pieces of approx. 48cm x 46cm and 80cm x 46cm. The first piece to be fitted on top and will contain the KLCR relays, LEDs and push buttons. The second piece to be fitted below the first piece. (Supply of KLCR relays covered in separate item of SOR). Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. | — | — | — | 47,511.36 | |
| — | 720.00 | — | — | ||
| Supply of Medium class GI pipes 100 mm Dia (4.5 mm thickness) as per IS 1239 (Part 1): 2004 with coupling on culverts bridges as per Drg. No. CSTE/NWR/SOR/06 to 12 or at any other locations as decided by Site Engineer. It includes supply of all material required for fixing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Supply. | — | — | — | 6,59,124 | |
| — | 1020.00 | — | — | ||
| Fixing of Medium class GI pipes 100 mm dia(4.5 mm thickness) as per IS 1239 (Part 1): 2004 with coupling on culverts bridges as per Drg. No. CSTE/NWR/SOR/06 to 12 or at any other locations as decided by Site Engineer. It includes installation of all material required for fixing arrangement. Contractor will install flexible/corrugated HDPE pipe at the end of GI pipe along with any masonry work (if required) to protect the cables from sharp edges and sudden bends. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after installation. | — | — | — | 2,33,447.4 | |
| — | 11000.00 | — | — | ||
| Supplying and placing of one layer of standard size of 'B' grade quality bricks of the local make spreading on cables laid. (minimum size of brick 200mm X 100mm X 70mm) Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Installation. Length wise (up to 2 cables). | — | — | — | 1,95,910 | |
| — | 36000.00 | — | — | ||
| Supplying and placing of one layer of standard size of 'B' grade quality bricks of the local make spreading on cables laid. (minimum size of brick 200mm X 100mm X 70mm) Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Installation. Width wise (more than 2 cables) | — | — | — | 13,80,960 | |
| — | 380.00 | — | — | ||
| Supply of Double Walled Corrugated (DWC) HDPE Pipe/duct with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non- flame propagating type in 6 meters straight length and of size 120 mm outer Dia & 103.5 mm inner dia. (The manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One of the following coupling arrangements should also be supplied with each pipe as per the site requirement.1) Suitable snap fit coupler with rubber O- Ring 2) Spacers3) Tees4) Bend,5) End-cap(The total quantity of above items is equal to no. of pipes supplied.)DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vendor name and year of manufacture can be easily identified. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs or as per extant policy (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs or as per extant policy Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% after Supply | — | — | — | 8,22,369.4 | |
| — | 3390.00 | — | — | ||
| Supply of Double Wall Corrugated (DWC)-HDPE pipe/duct of size 200 mm outer Dia, & 175 mm inner dia. It includes supply of Double Wall Corrugated -HDPE pipe/duct as per RDSO Spec. No. RDSO/SPN/ 204/2011 (version 1.1) or latest and conforming to ISI Spec. No.IS:14930, Part- II. (The manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One of the following coupling arrangements should also be supplied with each pipe as per the site requirement.1) Suitable snap fit coupler with rubber O- Ring 2) Spacers3) Tees4) Bend,5) End-capDWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vendor name and year of manufacture can be easily identified. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs or as per extant policy (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs or as per extant policy Inspection Charges: (i)Borne by Railways(ii) None Payment Terms: 100% after Supply | — | — | — | 15,64,518.9 | |
| — | 10800.00 | — | — | ||
| Placing of DWC HDPE/RCC/GI pipes along with collars in trenches at places near track and road, crossings, platform cuttings etc. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution | — | — | — | 3,84,588 | |
| — | 50.00 | — | — | ||
| Supply of Thermo shrink Universal Jointing kit for Quad Cable (for straight joints) as per RDSO spec IRS/TC-77/2012 revision 3 With latest Amd. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after Supply | — | — | — | 1,29,300 | |
| — | 3700.00 | — | — | ||
| Horizontal direction drilling/boring without damage of surface road /track using Auger Machine (HDD machine) or by Closed trench Method. The bore shall be upto 200 mm Dia & shall be done at the depth of minimum 1200 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. The length of the bore shall be minimum 4 Mtrs long. This includes insertion of different Dia DWC-HDPE pipe/ GI pipes coupling etc. as per direction of Engineer In charge. Note: - Pipe Supply is not covered under this item. Contactor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution | — | — | — | 53,56,749 | |
| — | 10.00 | — | — | ||
| Supply of galvanized cable markers as per Drg. No. CSTE/NWR/SOR/15. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Supply. | — | — | — | 2,903.8 | |
| — | 10.00 | — | — | ||
| Transportation at site and fixing of galvanized cable markers as per Drg. No. CSTE/NWR/SOR/15. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution | — | — | — | 726 | |
| — | 25.00 | — | — | ||
| Transferring of Signalling/Telecom cables from existing Location box to New Location box. The work includes breaking/ Dismantling of Existing foundation of locations, excavating and removing / segregating coils of 2C/6C/12C/19C/24C/30C/Quad cables which may be about 10 mtrs. in length. These cables are to be disconnected and removed from the existing location one by one as per the instruction and under the supervision of Railway staff present at site. The cable is then to be inserted and terminated in new location box. The item includes neatly dressing of cable, making wiring tree etc. The material required to dressing /lacing will be arranged by contactor. The work is required to be done systematically and with due precaution during the block or disconnection within the time that may be allowed. The excavation work to be done carefully without damaging the cable to avoid undue failure. (Termination charges will be given separately). Note: Proportionate payment will be made if cable of other length. One No unit = One cable of 10 m length) Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Execution | — | — | — | 10,889.25 | |
| — | 55.00 | — | — | ||
| Removal of excavated/slip earth/ debris/ malba from the site of works to any other place outside Railway land/premises, including all excavations, handling, re-handling, loading, unloading and leading, etc. all labour and material as a complete job. Removal of Earth (all kinds of soils)/ROCKS, BOULDERS including mud/slush, slipped earth in catch water drains, side drains, over berms in cutting, water way of bridges, over coping of toe/breast/retaining walls etc. including crossing of nallah, railway tracks, making/repairing approach roads if required, all lead, lift, ascent, descents, or any other obstruction. Earth spoils to be dumped outside the cutting or railway embankments as per direction of Engineer in charge. (cum is Cubic Meter) Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Execution | — | — | — | 9,143.75 | |
| — | 9000.00 | — | — | ||
| Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom as per RDSO sketch No. SDO/CABLE LAYING/003 or latest alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc, covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on North Western Railway and instructions of Railway Engineer at site. In case 1.2m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1.2m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1.2m. (cum is Cubic Meter) Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution | — | — | — | 29,70,900 | |
| — | 1800.00 | — | — | ||
| Digging of trench 1.2 Mtrs. deep from rail flange/ road level and 0.3 Mtrs to 0.6 Mtrs wide and back filling after placing of DWC/ RCC/GI pipe. (Placing of DWC/RCC/GI pipe covered separately). The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. For track crossing, Drg. No. CSTE/3644 Pg.7 of 11 and for Road Crossing, Drg. No. CSTE/3644 Pg. 5 of 11 are to be followed. (cum is Cubic Meter) Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution | — | — | — | 5,94,180 | |
| — | 1440.00 | — | — | ||
| Digging of cable trench 0.3 Mtrs. Deep and 0.3 Mtrs. Wide on Asphalted Platform / Road / Hard rocky area. Refilling with earth levelling of trenches & restoring the original surface of trenches. The sharp edges will be smoothened out in bottom of the chase and will be levelled properly. In hard rocky ground area, cables will be laid normally on layer of shifted earth of 0.05 mtrs thickness previously deposited at bottom of the trench and cables will be covered with layer of sand or shifted earth of 0.1 mtr thickness. In case sharp edges of rocky ground cannot be protected from shifted earth then GI/ CI /PVC /DWC/ HDPE pipes will be used, if numbers of cables are small. In case number of cables are large RCC duct will be used. In isolated cases, it can be given smooth surface by using either masonry bricks or cement concrete. A row of bricks shall then be placed length wise on the top and jointed with cement mortar and layer of concrete with cement plaster shall be provided on top of the same. Note: This item in hard rocky area will be operated only where normal depth i.e.l.2 mtr is not possible and it will be decided by site engineer/unit officer incharge of work. (cum is Cubic Meter) Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution | — | — | — | 8,71,790.4 | |
| — | 3.00 | — | — | ||
| Digging of cable pit (min 2x2x1m) as per instruction of Site Engineer, supplying and filling of sand before and after coiling the cables, covering top of the cable pit with stones and providing brick masonry on all four sides of the cable pit and plastering thereafter. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Execution | — | — | — | 45,155.01 | |
| — | 124500.00 | — | — | ||
| Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trunking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of coloured plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each Gantry Post/hectometer post. (Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution | — | — | — | 13,63,275 | |
| — | 70.00 | — | — | ||
| Providing brick masonry in ratio 1:6 cement and mortar including plastering with 1:4 cement and sand mixture both sides, 20 mm thick each with contractor's owned class II bricks, including excavation, curing, grouting, bolting etc. wherever required. Bricks sand and cement to be supplied by the contractor.(cum is Cubic Meter) Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution | — | — | — | 1,67,692.7 | |
| — | 6.00 | — | — | ||
| Video recording of cable trench using minimum 720P and above HD camera and submit one copy in New removable hard disks (With capacity as per requirement). Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution | — | — | — | 20,904 | |
| — | 4.00 | — | — | ||
| Supply of Earth Leakage Detector (ELD), LEVEL-3, as per RDSO Spec. RDSO/SPN/256/2025 or latest., with Earth Fault Localization system. The engineer-in-charge to specify the distribution of number of channels of DC or AC voltage on the bus bar/ conductor for which earth leakage detector is required. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after Supply 12 Channel Earth Leakage Detector | — | — | — | 7,62,745.68 | |
| — | 4.00 | — | — | ||
| Wiring, installation, testing and commissioning of Earth Leakage Detector (ELD), 12/16 Channels as per RDSO Spec. RDSO/SPN/256/2025 or latest. This includes supply of fuse terminal strip for incoming power supply wires. On job training at site will be given by OEM engineer for installation and maintenance of ELD. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after commissioning. | — | — | — | 1,90,686.44 | |
| — | 25.00 | — | — | ||
| Supply of basic material to construct unit maintenance free earth as per RDSO Specs. No. RDSO/SPN/197 Version 1.0 dtd. 04.07.2016 or latest and conforming to RDSO Drg. No. SDO/ RDSO/E&B/001. It consist of following: (a) Copper bonded steel electrode of 3.0 m long, 17 mm Dia with copper bonding thickness of minimum macrons and UL listed and marked = 1 no. (b) Earth enhancement material supplied in sealed bags of minimum 10 kg = 3 nos. (c) Copper strip of 150x25x6 mm, to terminate earth rod = 1 no. (d) Copper strip of 300x25x6 mm (MEEB) = 1 no. (e) Copper strip of 150x25x6mm (SEEB) = 1 no. (ii) Supply of 35 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting main earth electrode to MEEB in the equipment room in duplicate.(minimum 10 meter) (iii) Supply of 16 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting MEEB to SEEB and SPD to MEEB (minimum 10 meter ) (iv) Supply of 10 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting various equipments to SEEB (v) Supply of copper lug sleeve for 3/16 cable Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after Supply | — | — | — | 5,27,455.75 | |
| — | 25.00 | — | — | ||
| Installation of Unit Maintenance Free Earth as supplied under item no. 13010300 above It includes: ( i ) Digging the earth to the required depth. (ii) Insertion of electrode. (iii) Filling of earth enhancing compound (Approx.30 Kg) (iv) Provision of exothermic weld connections to copper tape of 25 mm x 6 mm x 150 mm to the earth electrodes. All material tools and features required for weld will be arranged by contractor. (v) This also includes CC cover 1.5 ft x 1.5 ft. 1 ft wall thickness 2 inch with cover 3-inch thickness. Cables 35 Sq mm/ 16 Sq mm/10 sq mm for connecting earth to busbar, busbar to busbar and busbars to various equipments. Earth electrode of 17.20 mm Dia and 3.00 meter long high tensile low carbon steel circular rods molecularly bonded with copper and outer surface (minimum copper bonding thickness of 250 microns to made requirement of under writer's laboratories (UL) 467-2007 or latest. Copper strips of 150 mm x 25 mm x 6 mm to be welded with each earth electrode, copper strips of 300 mm x 25 mm x 6 mm for main equip- potential busbar, copper strips of 150 mm x 25 mm x 6 mm sub equip-potential busbar in relay room, power room and panel room. GI strip 25 mm x 2 mm for ring formation of earth pits Earth enhancement material in bags for each Earth Electrode. Inspection chamber of site 300 mm x 300 mm x 300 mm (Inside dimension) of approximate 50 mm thick with pulling hooks to cover the earth pits. Note: The installation of this item shall be carried out by the contractor as per RDSO/SPN/197 Version 1.0 dtd. 04.07.2016 or latest and conforming to RDSO Drg. No. S DO/RDSO/E&B/001 or latest. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after execution and testing. | — | — | — | 2,36,538.25 | |
| — | 90.00 | — | — | ||
| Supply and Installation of earth electrode including MS flat for signalling equipments on lever frame, apparatus cases, signal, relay racks, cable termination rack, block instrument etc. (supply & installation of earth electrode as per drawing no. RE/S&T/DRG/Tender/SK/398/94 for apparatus cases, signal post & other equipments as per instruction on earthing of S&T equipment. Laying of earth lead mild steel flat of size 35mmx6mm and fixing of lead MS flat to earth electrode and lever frame, signal post & apparatus cases as per Drg. No. CORE/S&T/ALD/SK/591/2008, 592/2008 and 593/2008 respectively and instructions on earthing at S&T equipment and providing cement enclosure for earth electrode as per drawing no. RE/S&T/Sig./Tender/SK/13/85 Alt. A) Note: This item requires for earthing of all the A/Cases & Signal as per RE standard. Inspection: Consignee Inspection charges: None Payment terms: 70% after supply, 20% after installation & 10% after commissioning | — | — | — | 7,37,987.4 | |
| — | 1.00 | — | — | ||
| Provision of Ring Earth for EI system which includes supply of all components of earthing & bonding system like earth electrode, earth enhancement material, earth pit, Equi- potential earth busbar, connecting cables and tape/strips and other associated accessories in accordance with RDSO/SPN/197 Version 1.0 dtd. 04.07.2016 or latest, consisting minimum 8 Nos. of earth pits connected in a ring to achieve less than 1 Ohms earth resistance for connecting EI equipments, relay racks, panel, power equipments as per Signal Engineering Practice. Diagram of ring earth should be supplied to Railway for Approval before execution. All related material as recommended by RDSO in Spec. No. RDSO/SPN/197 Version 1.0 dtd. 04.07.2016 or latest, will be supplied by the contractor. basic material for one earth pit is given below: (a) Copper bonded steel electrode of 3.0 m long, 17 mm Dia with copper bonding thickness of minimum macrons and UL listed and marked = 1 no. (b) Earth enhancement material supplied in sealed bags of minimum 10 kg = 3 nos. (c) Copper strip of 150x25x6 mm, to terminate earth rod = 1 no. (d) Copper strip of 300x25x6 mm (MEEB) = 1 no. (e) Copper strip of 150x25x6mm (SEEB) = 1 no. (f) Supply of 35 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting main earth electrode to MEEB in the equipment room in duplicate.(minimum 10 meter) (g) Supply of 16 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting MEEB to SEEB and SPD to MEEB (minimum 10 meter ) (h) Supply of 10 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting various equipments to SEEB (i) Supply of copper lug sleeve for 3/16 cable Note: Earthing arrangement for EI must be as per RDSO guidelines issued by RDSO vide TAN/3006 dated 30.06.2025 or latest. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after Supply. | — | — | — | 1,82,923.54 | |
| — | 1.00 | — | — | ||
| Installation, testing and commissioning of Ring Earth for EI system which includes installation of all components of earthing & bonding system like earth electrode, earth enhancement material, earth pit, Equi- potential earth busbar, connecting cables and tape/strips and other associated accessories in accordance with RDSO Spec. No. RDSO/SPN/197 Version 1.0 dtd. 04.07.2016 or latest consisting minimum 8 Nos. of earth pits connected in a ring to achieve less than 1 Ohms earth resistance for connecting EI equipments, relay racks, panel, power equipments as per Signal Engineering Practice. Diagram of ring earth should be supplied to Railway for Approval before execution. Installation of one earth pit includes ( i ) Digging the earth to the required depth. (ii) Insertion of electrode. (iii) Filling of earth enhancing compound (Approx.30 Kg) (iv) Provision of exothermic weld connections to copper tape of 25 mm x 6 mm x 150 mm to the earth electrodes. All material tools and features required for weld will be arranged by contractor. (v) This also includes CC cover 1.5 ft x 1.5 ft. 1 ft wall thickness 2 inch with cover 3-inch thickness. Cables 35 Sq mm/ 16 Sq mm/10 sq mm for connecting earth to busbar, busbar to busbar and busbars to various equipments. Earth electrode of 17.20 mm Dia and 3.00 meter long high tensile low carbon steel circular rods molecularly bonded with copper and outer surface (minimum copper bonding thickness of 250 microns to made requirement of under writer's laboratories (UL) 467-2007 or latest. Copper strips of 150 mm x 25 mm x 6 mm to be welded with each earth electrode, copper strips of 300 mm x 25 mm x 6 mm for main equip- potential busbar, copper strips of 150 mm x 25 mm x 6 mm sub equip-potential busbar in relay room, power room and panel room. GI strip 25 mm x 2 mm for ring formation of earth pits Earth enhancement material in bags for each Earth Electrode. Inspection chamber of site 300 mm x 300 mm x 300 mm (Inside dimension) of approximate 50 mm thick with pulling hooks to cover the earth pits. Note: Earthing arrangement for EI must be as per RDSO guidelines issued by RDSO vide TAN/3006 dated 30.06.2025 or latest. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after commissioning. | — | — | — | 45,730.88 | |
| — | 18.00 | — | — | ||
| Supply of Professional AC/DC clamp meter 3 ¾ digit, true RMS measurement, For Measurement of DC/AC currents up to 60A, AC/DC Voltage up to 600V, resistance up to 40 M, Current resolution 0.1mA for low current measurements, frequency up to 60 KHz and non-contact voltage measurement function with set of leads & carrying case. Model - SCM222 or equivalent/ higher make. Motwane/Stanlay/Fluke/Megger Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Supply. | — | — | — | 3,02,118.3 | |
| — | 2.00 | — | — | ||
| Standard Tool kit for signal maintenance (suitable for RE area working) with following items (with small size canvas log) (i) Insulated combination plier of 8" = 1no. (ii) Insulated long nose plier of (road wise) 6" =1 no. ( iii) Insulated wise stroper plier of 6"=1 no ( iv) Insulated screw driver set(5 piece) =1 set (v) Side cutting plier 6" =1 no (vi) Hex with frawise 12"= 1 no (vii) Double end spanner set (6 to 32mm) = 1 set (viii) Adjustable spanner set 8" =1 no (ix) Ball pin hammer 200 gm =1 no (x)Soldering iron 25 watt =1 no ( xi)Torch cell LED (3 cell) Eveready/jeep = 1no (xii) Auto ranging digital multi-meter (Branded) =1 no (xiii) Crow bar steel/ tommy bar =1 no Inspection: Consignee Inspection charges: None Payment terms: 100% after supply | — | — | — | 12,663.48 | |
| — | 1.00 | — | — | ||
| Dismantling of existing lever frames/signal fittings/point fittings/lifting barriers (within station limit)/indoor and outdoor equipment and all other released material of S&T at way-side station (3/4 Line). All the released material will be transported to the place/location as decided by site engineer. The item includes: i) Mechanical Signalling gears like levers, down rods, locking trough, Rodding, wire transmission, signal posts and hoods etc. ii) Electrical Signalling gears like relays, batteries, indicators, SM slide control and all released wire transmission for slot, telephone, selector control and their related items etc. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Execution | — | — | — | 64,088.45 | |
| — | 100.00 | — | — | ||
| Transportation of S&T material Transportation of S&T material leading up to 1 Km including Loading from Starting point, unloading & stacking at destination. The work is to be done as per the instructions of Railway Representative at site. Consignee will also provide gate pass / road permit to the transporter. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Execution | — | — | — | 75,607 | |
| — | 400.00 | — | — | ||
| Transportation of S&T material Extra for each additional 1 Km or part thereof. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Execution | — | — | — | 2,740 | |
| — | 1.00 | — | — | ||
| Complete painting and varnishing work at a station (5/6 or more Line). This includes painting of signal posts and fittings, apparatus cases, point machines, junction boxes, rail post etc. This also includes varnishing, letter writing on relays, terminal Nos., apparatus cases, point machine, Signal Nos. and other details as per Signal Engineering Manual and instructions of Engineer at site. The item includes painting of distances of main cable run from G.P nearest to cable run and painting of distances of signals from nearest line on the signals base. At least two coats of paint are to be applied besides primary coating of red oxide. This includes supply of paints, varnishes and all other material required for complete painting work at a station. This includes painting on existing functional units also. The painting shall consist of initial red oxide / base paint followed by at least two coats of the paint as per standard painting scheme. This item also includes painting of interlocked gate attached to the station. Location box no. shall be painted on both sides. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Execution | — | — | — | 60,929.22 | |
| — | 2.00 | — | — | ||
| Designing and Plotting of Signalling Interlocking Plan (SIP) in AUTOCAD. Two copies of prints with soft copy will be submitted to Railway for checking. If alterations are suggested/proposed by Railways then again two copies of prints will be submitted for advance approval after carrying out all the alterations as suggested/proposed by the Railways. Tracings will be submitted for all the diagrams mentioned above for the purpose of approval by Railway prior to commissioning of station. Inspection: Consignee Inspection charges: None Payment terms:100% after execution. | — | — | — | 67,545.24 | |
| — | 23.00 | — | — | ||
| Design of circuits in connection with preparation of wiring diagrams as per approved Signalling Plan and submission of indoor as well as outdoor completion documents. It includes Route Section Plan (RSP), Selection Table (ST), Locking Table (LT) and Control Panel Diagram (CPD)/VDU Diagram. Two copies of prints with soft copy will be submitted to Railway for checking. If alterations are suggested/proposed by Railways then again two copies of prints will be submitted for advance approval after carrying out all the alterations as suggested/proposed by the Railways. Tracings will be submitted for all the diagrams mentioned above for the purpose of approval by Railway prior to commissioning of station. All drawings will be prepared in CAD. The wiring diagrams will consist relay rack analysis, relay contact analysis, fuse details. Tag block analysis etc. A separate CD/Pen drive will be submitted to Railway for each station along with original tracings. It also includes preparation and supply of laminated one set of all completion plans including circuit diagrams and indoor as well as outdoor completion documents on standard 75-micron polyester film for station in Auto CAD. 6 (Six) sets xerox copies will be submitted for each of the documents mentioned below: Cable Route Plan, Cable Core Chart, Location details plan for all the locations, Cable termination details, Signalling Plan, SWR Diagram, Wiring Diagrams, Selection Table, Locking Table, Contact Analysis, Fuse and Tag Block Analysis of Relay Rack and CT Rack, Control Cum Indication Panel/VDU diagram, Power Panel Diagram, Track Circuit Plan, Rack Erection Plan and Junction Box details etc. Note: Total cost of design and completion documents for a station/yard will be calculated on basis of total possible movements/routes as per Selection Table (ST). Inspection: Consignee Inspection charges: None Payment terms:100% after execution. | — | — | — | 1,14,982.52 | |
| — | 10.00 | — | — | ||
| Key Lock Checking Relay (KLCR) working on 24V DC, AC Immunized with different ward combinations and contact configuration 4F/4B with 2 extra ward plates and with case, RDSO spec no. RDSO/SPN/219/2016 ver 1.0 or latest, confirming to IRS S-23, S-34 & S@ 45<44@ IRS S:46. Inspection: - Consignee. Inspection charges: - None. Payment Terms: - 100% after supply. | — | — | — | 1,13,610.4 | |
| — | 100.00 | — | — | ||
| Supply & installation of copper tape 25x3mm for perimeter bonding in S&T rooms as per RDSO Drg. No. SDO/RDSO/E&B/001 or latest. Inspection: Consignee Inspection charges: Borne by Railways Payment terms: 70% after supply, 20% after installation & 10% after commissioning | — | — | — | 37,644 | |
| — | 10.00 | — | — | ||
| Jointing of 4 / 6 quad /Signalling cable with Heat Shrinkable straight through Jointing Kit. All the material required for the work are to be arranged by contractor himself at his own cost except Thermo shrinkable Joint Kit/Rapid Joint kit. After jointing the cable through test such as insulation test, continuity cable losses etc. to be carried out jointly with Railway Engineer. If any defect or any damage is observed during jointing, the contactor has to redo the joint free of cost. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution | — | — | — | 13,929.9 | |
| — | 100.00 | — | — | ||
| Supply of VF Transformer (1120:470/1120:1120/ 470:470/470:600/ 1200:600 Ohm) as per Specification No. IRS-TC-76/2021 Ver 1.0 or latest (Cylindrical type) or IRS/TC/22/ 2021 Ver 1.1 or latest (Rectangular type). Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Supply. | — | — | — | 1,07,700 | |
| — | 4.00 | — | — | ||
| Supply of various OFC joint enclosures Supply, preparation, splicing and installation of straight joint for 48 fibers along with enclosures with heat shrinkable splice protection sleeve as per TEC Specn. TEC 87080:2025 or latest. Splice losses in no case should be more than 0.1 dB. Inspection: Consignee Charges: None. Payment Terms: 100% after execution. | — | — | — | 59,484.68 | |
| — | 2.00 | — | — | ||
| Supply of permanently Pre-lubricated HDPE duct, 40 mm OD, 33 ID as per RDSO specification No. RDSO/SPN/TC/45/2013 Rev. 2.0 Amdt. 3 or latest. The item also includes supply of all the accessories of HDPE duct like end caps, collars, bends, couplers etc. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | — | — | — | 1,16,290.02 | |
| — | 2.00 | — | — | ||
| Laying of permanently Pre-lubricated HDPE duct, 40 mm OD, 33 ID as per RDSO specification No. RDSO/SPN/TC/45/2013 Rev. 2.0 Amdt. 3 or latest. The item also includes installation of all the accessories of HDPE duct like end caps, collars, bends, couplers etc. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution. | — | — | — | 29,072.5 | |
| — | 2.00 | — | — | ||
| Blowing/drawing of OFC cables in the HDPE duct along with all the protective work as per instructions of engineer incharge at site. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution. | — | — | — | 26,007.08 | |
| — | 2.00 | — | — | ||
| Construction of Brick Chamber/RCC of optical fibre cable straight through joint as per Drg. No. CSTE/NWR/ SOR/23. It also includes supply and provision of all the material required for this item like bricks, sand, cement etc. The cement and sand should be in ratio 1:6. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution. | — | — | — | 12,670.14 | |
| — | 50.00 | — | — | ||
| Supply of RCC cable route marker engraved and painted on both side along the route at every 50 meter and route diversion as per Drg. No 4014/00/CC4 or latest/ Stone marker. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Supply | — | — | — | 19,778.5 | |
| — | 1000.00 | — | — | ||
| Supply of indoor PVC cables Supply of 10 pairs annealed tinned copper conductor PVC insulated colour coded twisted pair switch board telephone cables PVC sheathed with nylon rip size 0.5 mm Each coil length of 100 mts of reputed make as per specification TEC GR/WIR-06/03.Mar 2002 (TEC 68080:2002) or latest. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after supply. | — | — | — | 76,000 | |
| — | 4.00 | — | — | ||
| Supply of various OFC termination boxes / FDMS Supply, installation, termination and testing of Rack/Wall mountable FDMS and termination as per TEC Specifications TEC 87020:2010 (TEC/GR/TX /FTB 01/03/ MAY-2010) or latest. IN and OUT 48 fiber OFC cables (with all connecting materials) routing/dressing fiber as per direction of engineer/In charge. This work includes termination/splicing of fibers and testing of fibers in the section/block and report of fiber to be submitted in hard and soft copy. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution. | — | — | — | 1,18,308 | |
| — | 29.00 | — | — | ||
| Supply of various DP boxes Supply of 20 Pairs Krone type D.P. box as per Tech spec, make Hensel or superior. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Supply. | — | — | — | 68,514.53 | |
| — | 19.00 | — | — | ||
| Supply of various DP boxes Fixing and wiring of 20 Pairs Krone type D.P. box as per Tech spec, make Hensel or superior. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after execution. | — | — | — | 11,222.16 | |
| — | 1.00 | — | — | ||
| 19-inch rack items Supply of covered 19" racks 42 U complete conforming to IEC 60297, with all fitting for housing the subrack LER, LSR, SDH ADMs & PD Mux or other equipments as per instruction of Railway Engineer fully wired including, Power supply distribution system, DDF, Internal wiring and other accessories, runway ladder etc. or for other application as per Drg. No. CSTE/NWR/SOR/24. The components of the rack are specified below- (i) Rack size 2035H X 600W X 600D (ii) Fixed side panels 42U X 600D (iii) Front glass door plain 42U X 600D (iv) Rear MS door plain 42U X 600W (v) Levelling screws-4 Nos. (vi) Compact Fan Module working with 48V DC or other voltage - 2 Nos. (vii) Earth connecting kit-1 No. (viii) Cable manager with cable loops-2 Nos. (ix) Krone mounting bracket-01 No (x) Caster with breaks-2Nos (xi) 20" length 1" width 5 mm thickness copper strip with 12 Nos. of holes including SS bolts & nuts for every hole to connect cables-2 Nos. (xii) 10A single pole DC MCB-2 Nos. (xiii) 6 A single pole DC MCB-2 Nos etc. The rack shall be completely wired and equipped with integrated protection modules for all channels as per technical specifications and other stipulations of tender document. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Supply. | — | — | — | 35,914 | |
| — | 1.00 | — | — | ||
| 19-inch rack items Installation, testing & commissioning of 24U/42U rack with 19-inch standard dimension as per instruction of Engineer in charge. It includes all the accessories for fixing of the same. | — | — | — | 1,955 | |
| — | 610.00 | — | — | ||
| Supply of CAT Cables / Patch Cord items Supply of STP (Shielded Twisted Pair) CAT-6 Cable compliant with TIA/EIA-568-B2-1 or latest. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Supply. | — | — | — | 24,400 | |
| — | 1.00 | — | — | ||
| Shifting and installation of Telecom equipment control and other telecom equipments like control phone, magneto phone, auto phone, VHF sets, VF Repeaters etc from old station building to new station building as per instructions of site engineer. All the material required for fixing and installation will be supplied by the contractor. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after execution. | — | — | — | 10,725.86 | |
| — | 100.00 | — | — | ||
| DLP Trunk items Fixing & wiring (Laying) of DLP trunk 80X50mm with required all changeable internal/external angle, changeable flat angle, flat junction. Clips, joint for cover, end cap etc. make Legrand or superior. Cable will be supplied by Railway and all other fixing material will be supplied by contractor. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after execution. | — | — | — | 19,700 | |
| — | 200.00 | — | — | ||
| DLP Trunk items Supply of DLP trunk 80X50mm with required all changeable internal/external angle, changeable flat angle, flat junction. Clips, joint for cover, end cap etc. make Legrand or superior. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Supply. | — | — | — | 1,57,604 | |
| — | 2.00 | — | — | ||
| Electronic LC Gate Telephone system Supply of Electronic LC gate telephone system in 1+6 configuration with inbuilt voice recorder. It includes supply of 'surge protection and line connection unit/circuit and centralised power supply system with battery as per RDSO Spec no. RDSO/SPN/TC/51/2021 Rev 1 or latest. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs or as per extant policy (ii) Consignee if value of whole item in work less than 10 lakhs or as per extant policy Inspection Charges: (i)Borne by Railways Payment Terms: 100% after Supply | — | — | — | 1,57,667.1 | |
| — | 1000.00 | — | — | ||
| Supply of indoor PVC cables Supply of 6 pairs annealed tinned copper conductor PVC insulated colour coded twisted pair switch board telephone cables PVC sheathed with nylon rip size 0.5 mm Each coil length of 100 mts of reputed make as per specification TEC GR/WIR-06/03.Mar 2002 (TEC 68080:2002) or latest. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after supply. | — | — | — | 37,000 | |
| — | 5.00 | — | — | ||
| 48 volts Batteries Banks & Chargers Supply of 48Volt/200AH maintenance free VRLA Batteries duly charged as per IRS Spec. No. S-93/96(A) with amendments-1 or latest Inspection: RDSO Inspection Charges: Borne by Railways. Payment Terms: 100% after Supply. | — | — | — | 4,63,515.8 | |
| — | 1.00 | — | — | ||
| Supply of Programmable Primary Digital drop insert Multiplexer complete with all accessories as per RDSO Specification IRS: TC: 68/2012, Rev.0 (Amdt. No. -1), including Connectors and cables required for installation including 100 Pair Krone type MDF. Each channel card shall have minimum four channels per card. The single sub rack shall be capable of being equipped up to min. 60 Channels without additional power supply unit. The MUX shall be wired & equipped for 30 channels, with following circuits: - 20 Nos of VF 2W/4W E&M Circuits; 4 Nos of 2 Wire FXO/Exchange Interface Circuits; 6 Nos. of 2W Subscriber /Hotline circuits along with ringer cards. Inspection:(i) RDSO if value of item in work more than 10 lakhs or as per extant policy (ii) Consignee if value of whole item in work less than 10 lakhs or as per extant policy Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% after Supply | — | — | — | 2,13,153 | |
| — | 10.00 | — | — | ||
| — | 6.00 | — | — | ||
| — | 1000.00 | — | — | ||
| — | — | — | 84,030 | ||
| — | 4.00 | — | — | ||
| — | — | — | 6,727.56 | ||
| — | 4.00 | — | — | ||
| — | — | — | 8,092.56 | ||
| — | 20.00 | — | — | ||
| — | — | — | 2,877.4 | ||
| — | 2.00 | — | — | ||
| — | — | — | 65,570.54 | ||
| — | 1.00 | — | — | ||
| — | — | — | 24,069.8 | ||
| — | 50.00 | — | — | ||
| Supply of UL standard PPTC fuses complies to UL Thermistor standard 1434 with rating- 2/4 Amps. Capacity wise distribution will be decided by Consignee. Inspection: Consignee. Inspection Charges: None. Payment Terms: 100% after supply. | — | — | — | 2,500 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TENDER DOCUMENT
ATTACHMENT
SNT-AII-14-2026-27EIATKHEMLI.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .