Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹17.3 L+₹40,909 (2.42%)Rejected-Finance GROUND FLOOR SUIT NO 2 SARITA APARTMENT KHARIDA MAIN ROAD KHARAGPUR 721 301 DIST PASCHIM MIDNAPORE WEST BENGAL | KHARAGPUR | PASCHIM MIDNAPORE | WEST BENGAL | 721301 | L2 | Rejected-Finance not being L1 | |
| 3 | L3₹19.7 L+₹2.8 L (16.6%)Rejected-Finance MALANCHA ROAD KHARAGPUR 721304 DIST WEST MIDNAPORE WEST BENGAL | KHARAGPUR | WEST MIDNAPORE | WEST BENGAL | 721304 | L3 | Rejected-Finance not being L1 | |
| 4 | L4₹19.8 L+₹2.9 L (17.1%)Rejected-Finance VILL SAROT PALLY PO SANKRAIL DIST HOWRAH PIN 711313 WB | SANKRAIL | HOWRAH | WEST BENGAL | 711313 | L4 | Rejected-Finance not being L1 | |
| 5 | L5₹19.8 L+₹3.0 L (17.5%)Rejected-Finance 193 E SHANTI PALLI PUSHPAHAR CO OPERATIVE KOLKATA 700107 | KOLKATA | WEST BENGAL | 700107 | L5 | Rejected-Finance not being L1 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
29 May 2021, 6:00 pmClosed
GE (AF) Kalaikunda
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore St West Bengal Pin 721303
DAY TO DAY MAINTENANCE OF E/M SERVICES AND REPLACEMENT OF ELECTRICAL FITTINGS, REWIRING AND ALLIED WORKS AT AF STN KALAIKUNDA
2021_MES_441554_1
8661/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) Kalaikunda
AS PER NIT
6 documents required · 6 mandatory
₹500
GE (AF) Kalaikunda
₹50,000
Yes
14 Jul 2021
8 May 2021
31 May 2021
8 May 2021
29 May 2021
24 May 2021
8 May 2021 - 11 May 2021
Amount
Supply and fix in repair switch piano, flush button, single pole, one way, 5 Amps, complete all as specified and directed.
Supply and fix switch piano, flush button, single pole, one way, 5 Amps, complete all as specified and directed. (Note : Item to be measured if executed under new point wiring)
Supply and Fix, in repair switch socket combination 2 in 1, 5A,flush type, complete all as specified and directed.
Supply and Fix, switch socket combination 2 in 1, 5A,flush type, complete all as specified and directed. (Note : Item to be measured if executed under new point wiring)
Supply and Fix in repair switch socket combined outlet 2 in 1, 3 pin, flush type 5 and 15 Amp universal multi purpose complete all as specified and directed.
Supply and Fix switch socket combined outlet 2 in 1, 3 pin, flush type 5 and 15 Amp universal multi purpose complete all as specified and directed. (Note : Item to be measured if executed under new point wiring)
Supply and fix in repair Ceiling Rose, three terminal, PVC/ Polycarbonate insulated body, complete all as specified and directed.
Supply and fix Ceiling Rose, three terminal, PVC/ Polycarbonate insulated body, complete all as specified and directed. (Note : Item to be measured if execuated under new point wiring)
Supply and fix in repairs,bell push, flush type, single pole, 5 Amps, complete all as specified and directed.
Supply and fix ,bell push, flush type, single pole, 5 Amps, complete all as specified and directed. (Note : Item to be measured if executed under new point wiring)
M&L in repair Buzzer electric single phase suitable for 230 Volt complete including taking out u/s : Make : Anchor / L& T/ Havells
Supply and Fix in repairs, Bell Ding Dong, AC 230 volts, single pole, complete all as specified and directed.
M&L bell ding dong type,AC, 230 volts, single pole on PVC box complete all as specified and directed (Note : Item to be measured if executed under new point wiring)
M&L in repair lamp holder , PVC/Poly carbonate type with back plate suitable for batten fittings to be fixed on PVC box with and including 10 watt LED lamp complete all as specified and directed Make For holder : Anchor / L& T/ Havells. LED lamp : Philips/ Bajaj/ Crompton/ Havells/ Century
M&L lamp holder , PVC/Poly carbonate type with back plate suitable for batten fittings to be fixed on PVC box including supply and fixing 10 watt LED lamp. Make For holder : Anchor / L& T/ Havells. LED lamp : Philips/ Wipro/ Crompton/ Surya (Note : Item to be measured if executed under new point wiring)
S&F LED 18 Watt tube light fitting (T8 type) ,single end connection type including LED retrofit tube lamp 18 W , 240 Volt, PF > 0.90, colour Temp 6500 K, System Luminious efficacy > 100Lm/W, complete with powder coated CRCA decorative box type batten suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting complete. Make :- Bajaj (Batten Cat No. BLRB DB 118 box type batten suitable for 18/20 watt retofit LED tube single side connection type). LED lamp : Make : Bajaj Cat No. BLRB 18W CW LED (retrofit LED tube lamp 18 Watt, Single end connection) or equivelent in Century /Philips as approved by GE. Note : Make of batten and LED tube lamp should be of same make. (Note : Item to be measured if executed under new point wiring)
Taking down old unserviceable TPN / SPN MCB DB's incl MCB of any size and any discription complete all as specified and directed .
S & F sheet metal enclosure for MCB, DB, VTPN 415 Volts,IP-43, 100 amps rated copper busbar 4 way Double door ( Vertical DB with MCB as incomer) Confirming to IS as per IEC 61439-3 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing complete all as specified and directed by Engr-in-charge. Make Legrand/ Seimens/ Schinder/L&T. Note: DB and MCCB/MCB shall be of same make.
S&F sheet metal enclosure for VT DB TPN, MCB DB TPN 4 way (with provision for MCCB as INCOMER and MCB as out going), Confirming to IS as per IEC 61439-3, IP 43,double door including 63 Amp, 25 kA,TP MCCB as incomer (Vertical type double door, 63 Amps MCCB rate inclusive) including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing complete all as specified and directed by Engr-in-charge. Make Legrand/ Seimens/ Schneider/ L&T. Note: DB and MCCB/MCB shall be of same make.
S & F sheet metal enclosure MCB, DB, SPN, 240 Volts, 100 Amps rated copper busbar, Confirming to IS as per IEC 61439-3, 12 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge.Make- Legrand/ Seimens/ Schinder/L&T. Note: DB and MCCB/MCB shall be of same make.
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 Amps rated busbar, Confirming to IS as per IEC 61439-3, 8 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43 , IK 09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge.Make- Legrand/ Seimens/ Schinder/ L&T. Note: DB and MCCB/MCB shall be of same make.
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 Amps rated busbar, Confirming to IS as per IEC 61439-3, 4 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, Ik09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed .Make- Legrand/ Seimens/ Schinder/ L&T.
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 2 way, single door without bus bar, enclosure made up of CRCA sheet steel RAL 9003 powder coated, IP 30 complete all as specified and directed.
S&F in repair MCB FP 50 to 63 Amps, 10 KA 'C' Curve breaking capacity, including connection with suitable size copper lugs complete all as specified and directed.
S&F in repair MCB FP 100 Amps, 16 KA 'C' Curve breaking capacity, including connection with suitable size copper lugs including complete all as specified and directed.
S&F in repair MCB SP 240 volts 6 to 32 Amps, 10 KA breaking capacity, 'C' Curve including connection with suitable size copper lugs complete all as specified and directed by Engr-In-Charge.
S&F in repair MCB SPN 6 to 32 amps 10 KA , 'C' Curve including connection with suitable size copper lugs complete all as specified and directed Make- Legrand/ Seimens/ Schinder/L&T/ABB.
Supply and fixing in repair of stepped type electronic fan regulator 100 watt flush type (delux) on the existing hylem laminated sheet etc as required complete all as specified and directed. Make: Anchor (Delux) / L&T/ Havells
Supply and fixing of stepped type electronic fan regulator 100 watt flush type (delux) on the existing phenolic laminated sheet etc as required complete all as specified and directed Make: Anchor (Delux) / L&T/ Havells (Note : Item to be measured if executed under new point wiring)
S&F LED 18 Watt tube light fitting (T8 type) ,single end connection type including LED retrofit tube lamp 18 W , 240 Volt, PF > 0.90, colour Temp 6500 K, System Luminious efficacy > 100Lm/W, complete with powder coated CRCA decorative box type batten suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting complete including taking down old unserviceable complete all as specified and directed . Make :- Bajaj (Batten Cat No. BLRB DB 118 box type batten suitable for 18/20 watt retofit LED tube single side connection type). LED lamp : Make : Bajaj Cat No. BLRB 18W CW LED (retrofit LED tube lamp 18 Watt, Single end connection) or equivalent in Crompton /Philips/ Century as approved by GE. Note : Make of batten and LED tube lamp should be of same make.
S&F in repair LED 2 X 18 Watt tube light fitting (T8 type) , including LED retrofit tube 2 x 18 W , 240 V, PF > 0.90, colour Temp 6500 K, System Luminious efficacy > 100Lm/W, complete with powder coated CRCA decorative box type batten suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round block white colour x 2 Nos for mounting of fitting complete all as specified & directed. Make Bajaj, Cat Part Batten : BLRB DB 218, Cat Part : LED refrofit tube : BLRB 18W CW LED or equivalent in Wipro/ Crompton. Note : Batten and tube shall be of same Make.
S&F in repair LED tube lamp 18 Watt (reterofit type, T8 pattern, single side connection) 240 V, PF > 0.90, colour Temp 6500 K, System Luminious efficacy > 100Lm/W, to be fixed in existing or new batten/ patti including changing the wiring suitable for T8 LED retrofit lamp in existing tube light fitting complete. Make :- Bajaj Cat No. BLRB 18W CW LED or equivalent in Philips/CG/Wipro as approved by GE.
S&F in repair LED 9/10 Watt tube light fitting intergated type, 240 v, PF > 0.90, colour Temp 6500 K, suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm three core, and PVC round block white colour x 2 Nos for mounting of fitting complete all as specified & directed. Make :- Bajaj/ Crompton/Wipro/Philips as approved by GE.
S&F in repair LED lamp 18 Watt 4 Pin type, colour Temp 6500K, retrofit type in existing fitting with necessary change in wiring complete all as specified and directed by Engineer in charge. Make : Bajaj/ Crompton/Philips/Wipro as approved by GE.
S&F in repair LED light with pressure die-cast housing along with prismatic polycarbonate diffuser and LED's with secondary optics and IP-65 protection of 25 watt,PF>0.9, luminaire efficacy not less than 110 lm/ W for building security light complete all as specified and directed by Engineer in charge. Make : Bajaj Cat Part no. ENXT P 30L WH or equivalent in Crompton/Wipro/ Havells as approved by GE.
S&F in repair LED bulkhead light of 10W with pressure die-cast housing along with polycarbonate diffuser and LED's IP-65 protction of watt,PF>0.95 complete all as specified and directed by Engineer in charge. Make : Crompton/Philips/Wipro as approved by GE.
Taking down carefully copper/ aluminium submain wirings of any size (2 runs single core including earth continuity) complete including PVC casing capping/ PVC conduit/Steel Conduit with fittings etc, removing materials from site and making good disturbed surfaces of walls, floors etc., complete all as specified and directed.
M&L for Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 6.0 Sqmm size as per IS 694: 2010 with multistranded copper conductor, FRLSH cable drawn in but including non metallic rigid PVC conduit of 25 mm dia ISI marked as per IS 9537 (Part-III): 1983 including PVC insulated unsheathed 6.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete complete all as specified and directed.
M&L for Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 4.0 Sqmm size with multistranded copper conductor FRLSH cable as per IS 694: 2010 (with colour code), drawn in but including PVC casing capping not less than 25 mm ISI marked including all accessories of casing caping as approved by EIC, including PVC insulated unsheathed 4.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete all as specified and directed.
M&L for Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 6 Sqmm size with multistranded copper conductor, FRLSH cable as per IS 694: 2010 drawn in but including PVC casing capping not less than 25 mm ISI marked including all accessories of casing caping as approved by EIC including PVC insulated unsheathed 6.0 Sqmm cable with multistranded copper conductor green PVC insulated as continous earth conductor cable connected to earth dolly complete all as specified and directed. .
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 10.0 Sqmm as per IS 694: 2010 (with colour code), drawn in but including PVC casing caping not less than 32 mm width ISI marked double locking type including one including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 10.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface/ recess complete all as specified and directed by EIC.
M&L for Sub main wiring with Four single core (3 phase) PVC insulated unsheathed cable 1100 volts grade, 6.0 Sqmm size with multistranded copper conductor, FRLS cable drawn in but including PVC casing capping not less than 32 mm ISI marked including all accessories of casing caping as approved by EIC including two run of PVC insulated unsheathed 6.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete ( 4 x 6.0 sqmm + 2 x 6.0 Sqmm earth wire) complete all as specified and directed
M&L for Sub main wiring with Four single core (3 phase) PVC insulated unsheathed cable 1100 volts grade, 10 Sqmm size with multistranded copper conductor, FRLS cable drawn in but including PVC casing capping not less than 40 mm ISI marked including all accessories of casing caping as approved by EIC including two run of PVC insulated unsheathed 10.0 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete ( 4 x 10.0 sqmm + 2 x 10.0 Sqmm earth wire) complete all as specified and directed
M&L for repairing distribution box(DB's) of any rating, any size by proper dressing of wirings,providing lugs, screw, nuts , cleaning of the burned surfaces etc, tightening of all the connections of incoming and outgoings from the MCB's/ DB, connecting Earthing connection to each earth dolly including fixing of DB cover by providing screws etc complete all as specified and directed by Engr-in-Charge.
S&F in repair PVC casing caping of min 25 mm dia exclusive of boxes (junction/ terminals) but inclusive of all tees, bends, elobows, reducers, bell mouth tube ends and fixing accessories such as coupler, lock nuts, saddles , pipe hook etc to be fixed on surface for dressing of wiring in neat presentable condition by proper relaying of existing PVC cables including removing of cables/ wires and relaying after fixing of new casing capping all as specified and directed,
Supply and fixing in repair PVC insulated multistranded Copper conductor, sheathed round cable ISI marked 2.5 sqmm x 3 core complete all as specified and directed .
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants,regulators, sockets etc. to be measured separately), removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls, floors, etc.complete all as specified and directed by Engr-in-charge.
M & L point wiring with 1.5 Sqmm multi stranded copper conductor 1100 V grade, ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLSH cable drawn in & including PVC casing caping of 25 mm wide, with double locking type, including all accessories casing caping as approved by EIC, with PVC 1.5 mm multi stranded insulated unsheathed copper wire, ISI marked of green colour for continous earth, including sunken in cast iron/MS/GI terminal box duly painted with aluminium paint inside and anticorrosive paint out side with 2.8 mm thick bakelite hylam sheet cover, ISI marked with CM/L no. for mounting switch & sockets for the following:- Note : (i) Contractor has to make the surface good after flushing the sunken box as existing without any extra cost (ii) Length or wiring 15 mtrs from switch board to be considered as one point wiring. (iii) Rate of circuit wiring from DB to switch board is included in unit rate of item. (iv) Sub circuit from MCB DB to Switch board should be of 3x2.5 Sqmm Cable and the length of 20 Mtr from the distribution board. Beyond this length it shall not be considered as point wiring and the whole length to be measured in sub main wiring
(a) One light/fan/ call bell point controlled by one switch.
(b) One 3 pin socket outlet 5 Amps on independent board.
(c) All as per item No-48 here-in-before but for switch socket combination 15 Amps 3/6 Pin on independent board with 2.5 Sqmm (Nominal area) PVC insulated unsheathed, stranded copper conductor FRLSH cable (1100 Volts grade) complete.
(d) M & L for power point wiring with 4.0 Sqmm multi stranded copper conductor 1100 V grade, ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLSH cable drawn in & including PVC casing caping of 25 mm wide, with double locking type, including all accessories casing caping as approved by EIC, with PVC 4.0 sqmm multi stranded insulated unsheathed copper wire, ISI marked of green colour for continous earth, for industrial metal clad socket power point. Note : (i) Length of power point wiring from DB to industrial socket upto 20mtrs distance shall be considered as one point wiring.
Supply and Fix in repair of 3 pin plug top AC-230 v 15 Amp complete all as specified and directed.
Taking down carefully, existing defective storage type water heater (geyser) of any Capacity and Make for repairing, including replacement of defective spares as required and including replacement of terminals with defective connection wires and reinstallation of the geyser in original position,removing the scale (white presipated) deposited in it, cleaning the inner tank properly including testing and commissioning, complete all as specified and directed. NOTES:- (i) Spares for replacement will be measured and paid separately.
Supply only the following spares suitable for storage type water heaters (Geyser) as per Existing.
(a) Thermostat, stem type, adjustable upto 75 Degree Celcius, ISI Marked (IS 3017). Make : Danfoss / Ranco / Indfoss
(b) Heating element 1.5 KW, ISI marked as per OEMs specifications Make : Bajaj / Usha/Theta
(c) Heating element 2 KW, ISI marked as per OEMs specifications Make : Bajaj / Usha/Theta
(d) Indicator lamp with flexibe copper wire of suitable size as per OEMs specifications
(e) PVC Connection with steel reinforced pipe for hot water connection of Size 18" x 1/2" including rubber washers.
(f) Copper Apperture plate suitable for 25/50 ltrs geyser along with rubber gasket, nuts, bolts,etc as per OEMs specifications complete.
S&F in repairs Heating element 1.5 KW, ISI marked ,model as per existing as per OEMs specifications type Make : Bajaj / Usha/Theta/ Havels/ Crompton. (Note heating element replaced other than in item No. 51.02 is measured under this item).
S&F in repairs Heating element 2.0 KW, ISI marked, model as per existing type as per OEMs specifications Make : Bajaj / Usha/Theta/ Havells/ Crompton. (Note heating element replaced other than in item No.51.03 is measured under this item.
M&L for complete servicing of solar hot water system (solar water heater, flate plate collector type), with cleaning of sluge deposited in pipe line of solar pannel by using cleaning regent, check and repair of pipe line for any leakage, including carring out brazing of copper pipe for leakage, cleaning of glass shell, cleaning of hot water tank, replacement of u/s clamps, adopter, hose pipe including filling of distilled water and coolent in reservior including complete sevicing to keep the plant functional of capacity up to 200 LPD. NOTES:- (i)Servicing shall be carried out through authorised technicians of the OEMs as approved by GE.
M&L in repair for replacement of thermostate, long body, ISI marked of solar water heater of cap up to 200 LPD as per OEMs specifications .
M&L in repair for replacement of electrical heating element of 2.0 KW (long thread type, as per existing), ISI marked, of solar water heater of cap up to 200 LPD as per OEMs specifications . Make: Solar Element or equivelent as approved by GE.
M&L for replacement in repair hot water pipe insulation with glass wool and aluminium cladding 20 mm bore including all material as required and directed by EIC.
S&F in repair single phase direct connection type KWH meter , temper proof, plastic body with LCD display, 230/240V, 5-30 Amp, accuracy class I, 50 Hz, Conf to IS 13779, IP 54, with ( parameters to show Date, time, current reading, KW, PF) in existing position by providing Polycarbonate box cover, including making complete electric connections all as directed specifed and directed by EIC Make : Secure (Model Saral) or eqivelent in L&T Note : Old meter to be deposite in AGE E/M store.
S&F in repair three phase, 4 wire direct connection type KWH meter , temper proof, plastic body with LCD display, 230/240V( P-N) and 400/415V (P-P), 20-100 Amp, sprint 350, accuracy class I, 50 Hz, Conf to IS 13779, IP 54, with ( parameters to show Date, time, current reading, KW, PF) in existing position by providing Polycarbonate box cover, including making complete electrical connections, connecting PVC cable by providing suitable size copper lugs etc, all as directed specifed and directed by EIC Make : Secure (Model Sprint 350) or eqivelent in L&T Note : Old meter to be deposite in AGE E/M store.
S & F single pole and neutral enclosure with two pin and earth, plug and socket , suitable for single phase 240 V,complete with one single pole MCB of capacity 20 amps having `C` charactristic, breaking cap 10 KA, including industial plug top, including taking down old u/s one complete all as specified and as directed. Make : Legrand cat part No. 607841 or equivelent in Schinder/ L&T.
S&F in repairs laminated hylam sheet cover, ISI marked with CM/L no., cut with grooves for mounting of fittings like switches, sockets, fan regulators etc. including fixing in loc with new galvanised screw and cup washer complete all as specified and directed by EIC of following sizes.
11 x 13 inches
9 x 11 inches
5 x 8 inches
5 x 5 inches
S&F Hylam sheet ISI marked min 2.8 mm sheet of suitable size as per site requirement to cover the DB box including cut with grooves for operation of MCB including fixing of sheet with providing steel /brass screw and cup washers as required at site complete as directed by Engineer in Charge.
Taking down old ceiling fan/Exhaust fans/Wall mounting fan of any cap/sweep after disconnecting the electric supply from any site, checking for its electrical defect and opening fans for checking of mechanical defect after dismentlling of fan, carried out repair/over hauling including removing dust and grease, and cleaning of internal mechanical parts of fan with kerosene oil, checking of alignment of shaft, oiling and greasing, checking of worn out bearing and other defective parts, winding, condenser etc and re-assembling, and connecting/refixing of fans in its original position by providing new GI nut bolt, lock washer and lock/split pin complete all as specified and directed by Engr-in-charge. NOTE: (i) Rewinding and replacement of defective parts etc shall be measured and paid seperately
Supply only the following items for fixing against defective parts of fan taking down under item No.63 herein before as per OEM Specification complete all as specified and directed by Engr-in-Charge.
(a) Bearing No.6201 as per OEM Specification, Make - SKF/ NBC/ FAG
(b) Bearing No.6202 as per OEM Specification, Make - SKF/ NBC/ FAG
(c) Bearing No.6203 as per OEM Specification, Make - SKF/ NBC/ FAG
(d) Bearing No. 6204 as per OEM Specification, Make - SKF/ NBC/ FAG
(e) Condenser 2.5 mfd Make : Epcos/Tibcon /Havells
(f) Condenser 4.0 mfd Make : Epcos/Tibcon /Havells
Taking down carefully ceiling fan 1200 mm sweep, dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts,re-assembling, hanging in original position including testing and commissioning, complete all as specified and directed. NOTES:- (i) Spare parts for replacement will be deemed to be included in Quoated rates.
M&L for Rewinding of Pedestal fan of sweep 400-600 mm including dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts,re-assembling, hanging in original position including testing and commissioning, complete all as specified and directed. NOTES:- (i) Spare parts for replacement will be deemed to be included in Quoated rates.
M&L for Rewinding of Exhaust fan of 280/300 mm any make any model , 1400 rpm including taking down ,dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts,re-assembling, hanging in original position including testing and commissioning, complete all as specified and directed. NOTES:- (i) Spare parts for replacement will be deemed to be included in Quoated rates.
M&L for Rewinding of Wall mounting fan of 300 to 400 mm sweep any make any model including taking down ,dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts,re-assembling, hanging in original position including testing and commissioning, complete all as specified and directed. NOTES:- (i) Spare parts for replacement will be deemed to be included in Quoated rates.
Taking down existing unserviceable CFL light fitting any type (600 mm x 600 mm) recess mounting/surface and S&F LED light fitting 36 watt recess mounting of size 600 mm x 600 mm , white powder coated CRCA housing with LEDs, seam less front frame with flat white high transmission acrlyic cover, classic design with glare free soft illumination, cool white, having lumen efficacy not less than 100 Lumen/ watt including making electric connection from source with PVC sheathed copper conductor wire and fixing light in celing by all providing all arrangements complete all as specified and directed .Make : Crompton Part No. LCTLRNE36FOCDL or equivalent in Philips/ Wipro/ Syska LED
Supply and Fix in repairs, Modular Switch, one way, 6 Amps, 1 Module, complete all as specified and directed.
Supply and Fix in repairs, Modular Switch, one way, 16 Amps, 1 Module, complete all as specified and directed.
Supply and Fix in repairs, Modular Bell Push, 6 Amps, 1 Module, complete all as specified and directed.
S&F in repair modular socket 6A/16A 2/3 Pin combined -2 module including repairing/replacement of whole modular fittings and frame with new one as per existing fittings complete all as specified and directed.
S&F in repair modular switch socket combination 16A , 6 Pin combined -3 module including repairing/replacement of whole modular fittings and frame with new one as per existing fittings including complete all as specified and directed.
Supply and Fix in repairs, Modular Fan step regulator, 120W - 2 module,complete all as specified and directed.
S&F in repairs PVC insulated, Single core, unsheathed, HRFR copper conductor flexible cable, 1100 Volt, Conf to IS 694, ISI marked of size 16 Sqmm including copper lugs, brass nut and bolt with washer of suitable size as per site requirement to connect the cable complete all as specified and directed
Supply and fixing in repairs wall mounted bed side study lamp aluminium body, 3 W LED type warm white including LED driver with on /off button switch ,flexible pipe with lamp head 360 degree rotating type, 220 Volts as per sample complete all as specified and directed by Engr- in- charge.
S & F bracket made of GI light grade pipe 1.2 Mtr long of size 32 mm bore bend to shape as per site requirment fixed to pole with 40 x 5 MM -02 Nos, size clamps bolts, Nuts, washers incuding painting two coats of aluminium paint over a coat of primer all as specified and directed Note :(i) For item to be replaced under repair (day to day complaint) contactors trade man shall report to E/M complaint cell daily and take complaint from concren JE E/M and after attending complaint he should give feedback and return the complaint slip to concern JE E/M in the evening at 17.30 Hrs on same day. (ii) Tradesman deployed for work should wear proper uniform with full shirt and full Pant. Colour code will be decided by EIC. (iii) Gyser complaint to be attend within 48 Hrs from the receiving of complaint , other wise panalty of Rs 200 per complaint per day will be imposed on contractor. In this decision of GE will final ,conculusive and binding. (iv) Being a maintenance contract site will be handover to contractor as per complaint received from user and as per site requirement. Though if the complaint given is of minor nature and if not attended within 48 hours, Penalty of Rs100.00 per day per complaint will be imposed on contractor. In this decision of GE will final ,conculusive and binding.. Full site cannot be handover to contactor at once . (v) For any minor repair required in wiring or their is any fault in circuit where the item under repair is to be replaced, contractor has to identify and recitified the fault without any extra cost.
Lotas Engineers
T K Construction
M/s Santosh Industrial Corporation
Ultimate Solution Company
SUMAN CONSTRUCTION
M/S ELECTROVISION
Universal Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .