Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.2 LAccepted-AOC A T ROAD BOKAKHAT 785612 DIST GOLAGHAT | BOKAKHAT | GOLAGHAT | ASSAM | 785612 | L1 | Accepted-AOC Rate quoted by Lowest Bidder M/S M.P. Agarwalla is accepted. | |
| 2 | Rejected-Technical A T ROAD M HO 2 BOKAKHAT HOUSE NO NIL CITY TOWN BOKAKHAT P O BOKAKHAT P S BOKAKHAT DISTRICT GOLAGHAT PIN 785612 | BOKAKHAT | GOLAGHAT | ASSAM | 785612 | - | Rejected-Technical Valid Electrical License is not submitted |
Tender Value
₹39.3 L
EMD Value
₹78,518
Closing Date
18 Jan 2024, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
O/O the Executive Engineer, PWD, Jorhat Electrical Division, Jorhat
Installation of Lift
2023_PWBNH_34733_1
EE/JED/OTDR/JESD/1 dated 28/12/2023
Open Tender
Electrical Works
Item Rate
45 days
Golaghat
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
₹78,518
Yes
Jorhat
19 Jan 2024
30 Dec 2023
18 Jan 2024
31 Dec 2023
18 Jan 2024
9 Jan 2024
31 Dec 2023 - 7 Jan 2024
8 Jan 2024
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group A
Group B
Group C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch
15/16 amp switch
3 pin 5/6 amp socket outlet
6 pin 5/6 amp socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 1 or 2 Module
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Providing and fixing 25mm x 5mm copper strip 40mmdia G.I pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and refilling etc. as required
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 120 sq. mm
Supplying of following sizes XLPE insulated and PVC sheathed aluminium conductor armoured power cable of 1.1 KV grade conforming to IS 7098(Part-I)/ 1988 with amendment up to date etc as required. (Both generator and Transformer connections) 4 X 25 sq.mm L.T. Armoured U.G. Cable
Supplying 150mm Exhaust Fan( Make- Havells model- ventil Air- DXW)
Providing and fixing 18mm thick gancg saw cul mirror polished. Premoulded and prepolished machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size approved shade, colour and texture land over 20mm thick base cement, mixed with matching pigment, epoxy touch ups,including rubbing, curing moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black. Cherry/Ruby red Area of slab over 0.50 sqm
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .