| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹16.0 LAccepted-AOC 4TH FLOOR C BLOCK RMZ CENTENNIAL PLOT NO 8A 8B 8C 8D DODDANAKUNDI INDUSTRIAL AREA T PL ROAD MAHADEVAPURA POST BANGALORE 560048 | BANGALORE | BANGALORE | KARNATAKA | 560048 | ₹16.0 L | 1 | Accepted-AOC Lowest Rate Offered |
| 2 | Not Admitted-Finance | - | - | Not Admitted-Finance Price Bid not complied |
| 3 | Not Admitted-Fee/PreQual/Technical SRINAGAR JAMMU KASHMIR 190001 UDYAM JK 21 0009179 | SRINAGAR | JAMMU AND KASHMIR | 190001 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | Agilent Technologies India Pvt. Ltd. L1 |
|---|---|---|---|---|
| 1.00Viscometer | ||||
| 1.01 | Dynamic Viscosity range: 15 mPa.s to 6M mPa.s, Torque range (10% to 100%): 0.00673 mNm to 0.0673 mNm, Torque resolution: ± 0.1 %of FSR (i.e. 0.0673 µNm), Accuracy:
±1.0 % of FSR (i.e 0.673µNm), Repeatability: ±0.2%, Speed range: 0.01 rpm to 250 rpm, Number of speeds: Speed list with 18 standard speeds - 1 fixed custom speed C0 (200 rpm) - Freely selectable speeds within the speed range - Speed resolution: 0.01 rpm to 9.99 rpm: 0.01 rpm - 10 rpm to 59.9 rpm: 0.1 rpm - > 60 rpm: 1 rpm, Spindle Coupling, Magnetic Spindle Coupling, Spindle Recognition, Instrument should automatically recognise Spindle, MOC of Spindle, SS316 Measurement Modes: Manual Mode, Stop at Time, Stop at Torque/Temperature/Viscosity Speed/Time Scan, All methods with: QC-limit function, User Instructions, User Interface: 7” color touchscreen, Data Storage: Data memory (upto 999 measurements) Print/Export from data storage, Data Transfer: PDF Export, CSV Table, Page Printer (USB or network), Temperature Measurement: Pt-100 Temp probe, Speed/Spindle Selection Mode: In stand-alone mode, the instrument should automatically run at different speeds to determine ideal speed needed to reach 80% torque. If torque cannot be reached with the attached spindle, the instrument should make spindle suggestions. Compatibility for Keyboard and Mouse: It should be possible to connect wireless keyboard and mouse directly to the viscometer, No of Ports: There should be minimum three USB ports and One Ethernet port in instrument, Measuring System SC4-18, Sample Volume : 6.7 ml, Viscosity range: 1.5 to 30K, DIN Adaptor, Required for measurement with a concentric cylinder (CC). Double-gap (DG) measuring system, Visco check VC 500, Viscosity standard for calibration | 1 | Nos | - |
| 2.00Florescence Spectrophotometer | ||||
| 2.01 | ● Measurements mode & Applications: Fluorescence, phosphorescence, chemiluminescence, and bioluminescence - Excitation, emission, constant wavelength synchronous, and constant energy synchronous spectral scanning;3D excitation/emission scans, 3D synchronous and kinetic scans, Chopper or suitable mechanism should be offered to block the beam when measuring luminescence or phosphorescence. Single or multiple wavelength kinetics along with Below Typical performance - Light Source: Xenon lamp 150 W or better - Monochromator: Czerny-Turner/ modified Rowland monochromator - Grating: Excitation: min.1200 lines/mm or better, Detectors: High performance room temperature PMT detector. The spectrometer should be equipped with a reference photodiode or PMT to monitor excitation lamp intensity fluctuations or reference signals. Spectral bandwidth :1.5 to 20 nm or better (continuously variable and computer controlled) Wavelength range: Excitation range (200 to 850 nm or better) & Emission range (200 to 850 nm or better) Wavelength accuracy: 1-1.5 nm or better Wavelength Repeatability: ± 0.2 or better Typical Signal to noise ratio: > 750:1 RMS sensitivity @ 350 nm excitation, excitation and emission slits 10 nm, 1 s Signal Averaging time Resolution :1.5-2 nm or better, Wavelength scan speed :> 24000 nm/min, or better, Certification: CE, Sample compartment and measurement modes: a) Sample compartment should be suitable for analyzing liquid (Right angle) and solid samples. b) A solid sample holder for recording the emission of powder and thin films samples should be provided. Software should be User friendly, original licensed Windows based operating software in the form of CD ROM/ flash drive, it should have built in features like have facility for scan application, kinetics. The software should be able to automatically collect a series of excitation, emission, or synchronous scans in all x modes. The 3-D data can be sliced to produce single excitation or emission scans, or contour plots can be created to show the number of emitting species. Upgradations: System must be upgradable Microplate Reader Accessory, fiber optics probe & Stop Flow accessories etc. Warranty: Two years including PC for the instrument and 10 years warranty for the Xenon Source Accessories:
• Cuvette pairs 3.5 mL– 1No and 350 µL– 1 No should be provided.
• Solid Sample Accessory: Should include dedicated attachment to hold Film Samples,
Powder Samples and 10 mm Cuvettes.
• Five Additional genuine License of fluorescence Software’s for students.
• 96 well microplate reader (optional).
• Suitable Factory configured PC.
• Vendor or OEM shall have repair/ service Centre in India.
• OEM/ vendor shall have demonstration facility/online support in India. | 1 | Nos | 16,02,626.07 ₹16.0 L |
Tender Value
Refer Docs
EMD Value
₹6 L
Closing Date
2 Jan 2026, 2:00 pmClosed
PRINCIPAL GOVT. DEGREE COLLEGE BANDIPORA
Govt. Degree College Pulwama
Supply of Florescence spectrophotometer and Rotational Viscometer for Govt. Degree College Pulwama
2025_HED_298685_1
02 of 2025
Open Tender
Laboratory and scientific equipment
45 days
Govt. Degree College Pulwama
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
Govt. Degree College Pulwama
₹6 L
Yes
13 Jan 2026
19 Dec 2025
3 Jan 2026
19 Dec 2025
2 Jan 2026
19 Dec 2025
Amount
Viscometer
Florescence Spectrophotometer
● Measurements mode & Applications: Fluorescence, phosphorescence, chemiluminescence, and bioluminescence - Excitation, emission, constant wavelength synchronous, and constant energy synchronous spectral scanning;3D excitation/emission scans, 3D synchronous and kinetic scans, Chopper or suitable mechanism should be offered to block the beam when measuring luminescence or phosphorescence. Single or multiple wavelength kinetics along with Below Typical performance - Light Source: Xenon lamp 150 W or better - Monochromator: Czerny-Turner/ modified Rowland monochromator - Grating: Excitation: min.1200 lines/mm or better, Detectors: High performance room temperature PMT detector. The spectrometer should be equipped with a reference photodiode or PMT to monitor excitation lamp intensity fluctuations or reference signals. Spectral bandwidth :1.5 to 20 nm or better (continuously variable and computer controlled) Wavelength range: Excitation range (200 to 850 nm or better) & Emission range (200 to 850 nm or better) Wavelength accuracy: 1-1.5 nm or better Wavelength Repeatability: ± 0.2 or better Typical Signal to noise ratio: > 750:1 RMS sensitivity @ 350 nm excitation, excitation and emission slits 10 nm, 1 s Signal Averaging time Resolution :1.5-2 nm or better, Wavelength scan speed :> 24000 nm/min, or better, Certification: CE, Sample compartment and measurement modes: a) Sample compartment should be suitable for analyzing liquid (Right angle) and solid samples. b) A solid sample holder for recording the emission of powder and thin films samples should be provided. Software should be User friendly, original licensed Windows based operating software in the form of CD ROM/ flash drive, it should have built in features like have facility for scan application, kinetics. The software should be able to automatically collect a series of excitation, emission, or synchronous scans in all x modes. The 3-D data can be sliced to produce single excitation or emission scans, or contour plots can be created to show the number of emitting species. Upgradations: System must be upgradable Microplate Reader Accessory, fiber optics probe & Stop Flow accessories etc. Warranty: Two years including PC for the instrument and 10 years warranty for the Xenon Source Accessories: • Cuvette pairs 3.5 mL– 1No and 350 µL– 1 No should be provided. • Solid Sample Accessory: Should include dedicated attachment to hold Film Samples, Powder Samples and 10 mm Cuvettes. • Five Additional genuine License of fluorescence Software’s for students. • 96 well microplate reader (optional). • Suitable Factory configured PC. • Vendor or OEM shall have repair/ service Centre in India. • OEM/ vendor shall have demonstration facility/online support in India.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.66 MB
TenderDocEquipment.pdf
Tender Documents • 1.65 MB
BOQ_968206.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid