| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹26.2 LAccepted-AOC 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹29.0 L+₹1.1 L (3.76%)Rejected-AOC | L-2 | Rejected-AOC L-2 | |
| 3 | L-3₹29.8 L+₹1.9 L (6.88%)Rejected-AOC H NO 90 VILLAGE REWLA KHANPUR PO NAJAFGARH NEW DELHI 110043 | NEW DELHI | WEST DELHI | DELHI | 110043 | L-3 | Rejected-AOC L-3 | |
| 4 | L-4₹30.7 L+₹2.8 L (9.97%)Rejected-AOC D1C 47A JANAK PURI NEW DELHI 110058 | NEW DELHI | DELHI | DELHI | 110058 | L-4 | Rejected-AOC L-4 | |
| 5 | L-5₹32.9 L+₹5.0 L (18.0%)Rejected-AOC | L-5 | Rejected-AOC L-5 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
6 Oct 2022, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICE, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
REPAIR/MAINTENANCE OF EXTERNAL ELECTRIFICATION, MAINTENACE OF TRANSFORMER, VCB AND LT UG CABLE AND ALLIED WORKS AT ZONE B AREA UNDER GE I RnD DELHI
2022_MES_551077_1
GE/RND-56/DLI/2022-2023
Open Tender
Civil Works
Item Rate
180 days
Delhi
Class-D, cat- b (ii)
2 documents required · 2 mandatory
₹500
GE I RND DELHI
₹90,000
Yes
17 Oct 2022
9 Sept 2022
8 Oct 2022
9 Sept 2022
6 Oct 2022
24 Sept 2022
Amount
Taking shut down from main substation and drain out the transformer oil and to be collected in barrel by opening the transformer cover of capacity 200 to 500 KVA by unscrewing the nuts/bolts and washers and kept in safe custody and reuse the same, and checking the any type of leakage from both HT and LT side including cleaning the sludge etc depositing in the core and tank by using soft brushes and clean with old transformer oil, refilling of transformer oil including refixing of top cover including nut/bolts etc and testing the input & output voltage and adjustment of the voltage through tape changer if required to the entire satisfaction of Engr-in-charge complete all as specified and directed.
All as per item ser No 1.00 above but of capacity 630 to 1000 KVA.
Taking shut down from main substation and M&L for painting of transformer with spray gun with two coats of synthetic enamel paint in grey tint including preparation of old painted surfaces/removing old faded/rust/ cemented material of surface of transformer including base frame, connected LT panels, duct covers of including writing MES/SM No of existing size/surface complete all as specified and directed.
Dehydration and filtration of transformer oil with proper dehydration machine to achieve dielectric strength between 45 to 50 KV including testing/recording of dielectric strength result before and after of dehydration complete all as specified and directed.
Supply and topping up transformer oil having dielectric strength not less than 45 KV complete all as specified and directed.
Taking proper shutdown & Isolate the HT electric supply and taking out the trolley of VCB/OCB HT 11KV 400 to 630 Amps of any make and type and servicing of all minor/major parts of the VCB/OCB by cleaning isolating contact moving parts,removing dust particle from the bus bar chamber spout gear mechanism, repair to motor charge spring mechanism,tightening of all nut & bolts of entire trolley component all as directed , inserting the trolley, testing the complete HT electric supply and putting on supply on load complete all as specified and directed. Note:- (i) All cleaning /testing equipment/ safety equipment material shall be provided by the contractor and rate of the same shall deemed to be included in quoted rates.
Calibration of relay of 11KV HT VCB/OCBs and 1.1KV ACBs installed at various sub station at KWC area complete all as specified and directed. Note:- 1. All testing & calibration equipment with all accessories shall be brought by the contractor and rate for same shall deemed to be included in quated rates. 2. The complete test report shall to be submitted by the contractor to Engineer-in-Charge /GE (I) R&D Delhi.
S&F in repair tripping coil suitable for 400 amps VCB/OCB complete all as specified and directed.
S&F in repair DC wiring suitable for 400 amps VCB/OCB complete all as specified and directed.
S&F in repair primary injection suitable for 400 amps VCB/OCB complete all as specified and directed.
S&F in repair TNC wiring suitable for 400 amps VCB/OCB complete all as specified and directed.
S&F LED type indicating lamp suitable for 400 amps VCB/OCB complete all as specified and directed.
S&F in replacement of charging motor suitable for 400 amps VCB/OCB complete all as specified and directed.
S&F in replacement of motor cut limit switch suitable for 400 amps VCB/OCB complete all as specified and directed.
S&F in replacement of limit switch suitable for 400 amps VCB/OCB complete all as specified and directed.
S&F in replacement of limit switch assembly suitable for 400 amps VCB/OCB complete all as specified and directed.
S&F in replacement of DC controling unit suitable for 400 amps VCB/OCB complete all as specified and directed.
S&F in replacement of CT with ratio 300/150/5-5 suitable for 400 amps VCB/OCB complete all as specified and directed.
S&F in replacement of CT with ratio 400/200/5-5 suitable for 400 amps VCB/OCB complete all as specified and directed.
S&F in replacement of AC/DC controlling unit suitable for 400 amps VCB/OCB complete all as specified and directed.
S&F in replacement of tripping and closing coil 24 V DC suitable for 400 amps VCB/OCB complete all as specified and directed.
S&F in replacement of bushing suitable for 400 amps VCB/OCB complete all as specified and directed.
S&F in replacement of bushing rod suitable for 400 amps VCB/OCB complete all as specified and directed.
S&F in replacement of CT with ratio 100/50/5+1 suitable for 400 amps VCB/OCB complete all as specified and directed.
S&F in replacement of 11 KV OCB spout suitable for 400 amps VCB/OCB complete all as specified and directed.
S&F in replacement of 11 KV OCB spout contact suitable for 400 amps VCB/OCB complete all as specified and directed.
S&F in replacement of panel wiring suitable for 400 Amps VCB/OCB complete all as specified and directed.
S&F in replacement of earth fault over current relay IDMT relay suitable for 400 amps VCB/OCB complete all as specified and directed.
S&F in replacement of 5 way RMU CT 400/200/1-1 complete suitable for RMU complete all as specified and directed.
S&F in replacement of CT with ratio 200/100/1-1 suitable for 5 way RMU complete all as specified and directed.
Taking proper shutdown & Isolate the HT electric supply and HT 11KV outdoor 5 way RMU of any make and type and servicing of all minor/major parts of the RMU by cleaning isolating contact moving parts,removing dust particle from the bus bar chamber spout gear mechanism, repair to motor charge spring mechanism,tightening of all nut & bolts and testing the complete HT electric supply and putting on supply on load complete all as specified and directed.
S&F in replacement of HRC/MCB fuse link clip type on fuse link 2 to 20 amps operating voltage 415 Volt complete all as specified and directed.
S&F in replacement of fuse base suitable for cylindrical/DIN type HRC fuse of capacity 2-32 amps complete all as specified and directed.
S&F in replacement of closing spring assembly complete all as specified and directed.
S&F in replacement of tripping spring assembly complete all as specified and directed.
S&F in replacement of charging motor cut off limit switch complete all as specified and directed.
S&F in replacement of spring charging handle motorized mechanism of VCB complete all as specified and directed.
S&F in replacement of push button bracket assembly complete all as specified and directed.
S&F in replacement of bus bar support insulator 75 mm dia including all fixing accessories complete suitable or VCB/HT bus bar chamber complete all as specified and directed.
S&F in replacement of bus bar barrier as per existing (set of three) with nuts bolts complete all as specified and directed.
S&F in replacement of toggle switch for space heater complete with all accessories complete all as specified and directed.
S&F in replacement of charged/ discharged indication assembly complete all as specified and directed.
S&F in replacement of 11 pin anti pumping relay 110 volt DC complete all as specified and directed.
S&F in replacement of bottom terminal with jaw contact complete all as specified and directed.
S&F in replacement of top terminal with jaw contact complete all as specified and directed.
S&F in replacement of space heater 230 volts AC 80 watts complete all as specified and directed.
S&F in replacement of thermostat with all accessories complete all as specified and directed.
S&F in replacement of PT epoxy female bushing suitale for R Y B phase complete all as specified and directed.
S&F in replacement of PT epoxy male bushing suitale for R Y B phase complete all as specified and directed.
S&F in replacement of PT fuse 11 KV complete all as specified and directed.
S&F in repair HT bushing 11 kv suitable for 200 to 1000 kva transformer including brass rod complete with gasket as per matching to existing complete all as specified and directed.
S&F in repair LT bushing 11 kv suitable for 200 to 1000 kva transformer including brass rod complete with gasket as per matching to existing complete all as specified and directed.
S&F in repair head gasket sheet 6 mm thick suitable for transformer 200 KVA to 450 KVA capacity including replacement of nuts bolts washers complete all as specified and directed.
S&F in repair head gasket sheet 6 mm thick suitable for transformer 500 KVA to 1000 KVA capacity including replacement of nuts bolts washers complete all as specified and directed.
S&F in repair temparature gauge analog type complete with all accessories as per matching to existing complete all as specified and directed.
S&F in repair voltmeter digital type for voltage range of 0 to 500 v including all accessories and wiring complete all as specified and directed.
S&F in repair ammeter digital type for current range of 0 to 1000 v including all accessories and wiring complete all as specified and directed.
S&F in repair power factor meter digital type for frequency range 45 to 650Hz as per matching to existing one including all accessories and wiring complete all as specified and directed.
S&F in repair three phase over current earth fault relay MC-61 as per matching to existing one including all accessories and wiring complete all as specified and directed.
S&F in repair three phase over current earth fault relay MC-61A as per matching to existing one including all accessories and wiring complete all as specified and directed.
S&F in repair three phase digital KV volt meter range up to 15 kv as per matching to existing one including all accessories and wiring complete all as specified and directed.
S&F in repair LED type indicating lamp of voltage AC/DC set of RYB as per matching to existing complete all as specified and directed.
S&F battery charger of capacity 12 volts for AMF panel complete all as specified and directed.
S&F battery charger of capacity 24 volts for AMF panel complete all as specified and directed.
S&F in repair Current Transformer as per matching to existing complete all as specified and directed.
S&F in repair Multifunctional meter complete all as specified and directed.
S&F in repair VCB power pack unit 24 volt DC 7 AH with battery bank for backup including panel as per existing matching complete all as specified and directed.
S&F in replacement of push button suitable for 400 Amps VCB/OCB complete all as specified and directed.
Supply and fix in replacement of ACB 4 pole ,415 V , with Thermal magnetic release (Manual fixed type) of capacity 630 Amps complete all as specified and directed.
Supply and fix in replacement of ACB 4 pole ,415 V , with Thermal magnetic release (Manual fixed type) of capacity 800 Amps complete all as specified and directed.
S&F in replacement of ACB 4 pole ,415 V , with Thermal magnetic release (Manual fixed type) of capacity 1250 Amps complete all as specified and directed.
All as per item ser No 71.00 above but capacity 1600 Amps.
Supply and laying XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cable(Heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 400 Sqmm 3.5 core complete including taking down old unserviceable power cable complete all as specified and directed.
All as per item ser No 73.00 above but area 120 Sqmm 3.5 core.
All as per item ser No 73.00 above but area 240 Sqmm 3.5 core.
All as per item ser No 73.00 above but area 150 Sqmm 3.5 core.
All as per item ser No 73.00 above but area 185 Sqmm 3.5 core.
All as per item ser No 73.00 above but area 95 Sqmm 3.5 core.
Material and Labour for earthing complete with Steel earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron earth wire 4.00 mm dia by means of Copper nuts, bolts and washers. GI wire shall be laid in 20 mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a) GI wire of 4 mm dia. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel TMT bar @75mm centre to centre with 2 Nos MS handles of 12mm dia mild steel TMT bars suitable for carrying of pit cover.
Excavation in trenches not exc 1.5 mtr wide and n. exc 1.5 m depth and getting out in soft/loose soil for laying UG cables of various sizes etc complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n. exc25 cm in soft/loose soil complete all as specified and directed.
Removing surplus excavated materials to a distance n. exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and directed.
Supply and laying in trenches burnt brick sub class 'B' standard size for cable protection keeping width of the brick parallel to the length of the cable complete all as specified and directed.
Supply and laying un-reinforced factory made precast concrete cable cover, class HV, type 1, flat size-300x180x40 mm complete all as specified and directed.
Supply and spread clean dry river sand in trenches ,ducts including leveling, punning for cushioning of cables complete all as specified and directed. Note : Punned thickness of sand cushioning shall be measured.
Supply and laying in trenches, fixed to wall / pole/ tray etc UG cable XLPE insulated armoured heavy duty electric UG cable with aluminum conductor 1100 volts grade of cross sectional area of following size complete all as specified and directed.
25 Sqmm 3.5 Core
35 Sqmm 3.5 Core
S&F MCCB 400Amps 4 Pole breaking capacity 36KA including taking down old unserviceable MCCB complete all as specified and directed.
S&F MCCB 250Amps 4 Pole breaking capacity 36KA including taking down old unserviceable MCCB complete all as specified and directed.
S&F MCCB 125Amps 3 Pole breaking capacity 16KA including taking down old unserviceable MCCB complete all as specified and directed.
S&F MCCB 100Amps 3 Pole breaking capacity 16KA including taking down old unserviceable MCCB complete all as specified and directed.
S&F MCCB 630 Amps 4 Pole breaking capacity 50 KA including taking down old unserviceable MCCB complete all as specified and directed.
S&F MCCB 160 Amps 4 Pole breaking capacity 36KA including taking down old unserviceable MCCB complete all as specified and directed.
Supply, installing, testing and commissoining factory made LT panel indoor type approx size 1550mmx1000mmx2075mm, platform mounted, suitable for 415 volts 3 phase and neutral 4 wire 50 Hz AC supply system having bus bar chamber with insulated electrolytic alluminium bus bar TPN of cap 1500 amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof and inner sheet made out of 2.00 mm thick CRCA mild steel sheet and mild steel mounting channel frame work made out of MS angle iron 75x40 mm duly painted with zink metal coating front opening type for installation of separates cable alleys, busbar chamber and switchgear compartments. Provision in cable alleys to be kept for bottom cable entry for incoming and outgoing cables. A clear space of 200 mm to be kept from floor level for switchgear compartments. Extended bus bar links/terminals, air ventilation breathers to be provided for heat dissipation suitable size knock-out holes for cables, gland shall be provided as per respective schematic drg of the following equipment/instruments. Each compartment shall be numbered/letters as per the approved drg affixing MV danger plate as suitable intervals/location, panel board compartment size should be suitable to accomodate the switchgear and other accessories as per IE rules, with proper ferrule & cable gland, internal wiring with pvc insulated multistranded copper conductor FRLSH cable of adequate size but not less than 2.5 sq mm complete. All steel metal works including frame shall be painted with anticorrosive coating with seven tank process and finally epoxy based make as per shade approved by Engr-in-charge, including taking down the old rusted panel from its position after taking proper shutdown including taking down old unserviceable complete all as specified and directed with comprising of followings:-
(a) Bus bar chamber:- (a) 1500 amps 3 phase & 1 neutral 1500 amps, alluminium conductor E-91 grade with color coded heat shrinkable sleave and shall be mounted on, non combustible, track resistance, high strength DMC material, interconnection of all incomings & outgoings. Instrument chamber:- (i) Digital multi function meter with LED display for measurement of voltage, current, frquency, power factor 3 phase - 01 set. (ii) C.T's of capcity 800/5A CI 1.0- 01 set(set of 3) (iii) Red, Yellow, Green phase indicating lights LED type 220 volt 50 Hz - 01 set (set of 3). (iv) Suitable protection MCB c series-01 set ( set of three). Incoming supply:- (i) ACB 800 amps breaking capacity 50 KA 4 pole, manual draw out (MDO) with microprocessor based LCD protection release 415 volts, 50 Hz- 02 No. Bus coupler:- (i) ACB 1250 amps breaking capacity 50 ka 4 pole, manual draw out (MDO), thermal release 415 volts 50 Hz - 01 No. Interlocking:- Complete electrically and mechanically inter locking between incoming supply & bus coupler - 01 set.
(b) Outgoing supply:- (i) MCCB 400 amps ,36 ka, 4 pole, adjustable type, thermal magnetic release 415 vilts, 50 Hz , ICS-100% ICU-02 Nos. (ii) MCCB 250 amps ,25 ka, 4 pole, adjustable type, thermal magnetic release 415 vilts, 50 Hz , ICS-100% ICU-04 Nos (iii) MCCB 200 amps ,25 ka, 4 pole, adjustable type, thermal magnetic release 415 vilts, 50 Hz , ICS-100% ICU-02 Nos Note: 1. Before fabrication of panel the contractor shall submit detailled general arrangement drawing and single line diagram of all panel for approval. A drawing shall also show foundation details, list of component in the manufacturer's refernce and bill of materials. 2. Panel should be manufactured by CPRI approved and manufacture's CPRI test certficate to be produced. 3. All civil works including foundations required shall deemed to be included in quoted rates.
S&F in repair end termination joint 11 kv indoor type, end termination heat shrinkable of size 3x95 sq mm including thimbling, nut/bolts & washers, HV insulating tape etc, complete all as specified and directed.
S&F in repair jointing kit for 11 kv ( earthed) grade cable for indoor termination, heat shrinkable of size 95 to 185 sq mm including thimblling, nut/bolts & washers, HV insulating tape etc complete all as specified and directed.
S&F in repair straight through joint 11 kv heat shrinkable of size upto 95 sq mm including thimbling, nut/bolts & washers, HV insulating tape etc complete all as specified and directed.
S&F in repair straight through joint 11 kv heat shrinkable of size 120 to 185 sq mm including thimbling, nut/bolts & washers, HV insulating tape etc complete all as specified and directed.
Supply and laying XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cable(Heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 120 Sqmm 3 core including taking down/out old unserviceable cable complete all as specified and directed.
Supply and laying XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cable(Heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 95 Sqmm 3 core including taking down/out old unserviceable cable complete all as specified and directed.
S&F in repair dehydrating breather assembly with silica gel grains in the breather assembly suitable for transformers 200 kva to 1000 kva as per matching to existing complete all as specified and directed.
Material and Labour for earthing complete with Steel earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron strip of 25x4 mm by means of Copper nuts, bolts and washers. Strip shall be laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a) GI strip of size 25mm x 4mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly be tightened on GI watering pipe and embeded in PCC earth pit with open top suitable for watering of earth pits) (c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel TMT bar @75mm centre to centre with 2 Nos MS handles of 12mm dia mild steel TMT bars suitable for carrying of pit cover.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as of size 25 x4 mm earth strip including taking out old unserviceable complete all as specified and directed.
S&F in replacement of RMU protection relay Frequence-50Hz, UN-in-1A, UV-18-60 volt DC and control rating-5A @ 220 volt AC and making as per existing make with all connected accessories complete all as specified and directed.
M&L for painting of LT panel indoor/outdoor type area of front face of panel exc 1.5 sqm but n. exc 2.5 sq m each with spray gun with two coats of synthetic enamel heat resistant grey paint including preparation of old painted surface/ removing old faded/rust/cemeted material of surface of complete LT panel complete all as specified and directed.
S&F in repair angle iron work and fixing/fabrication of angle iron frame for LT panel complete including welding work at site complete all as specified and directed.
S&F in repair 2mm thick CRCA sheet for LT panel including cutting, welding as per site requirement complete all as specified and directed.
All as per item ser No 107.00 above but 3.15 mm thick.
S&F in repair of aluminium bus bar PVC insulated in red,yellow, blue & black colours of rating 400 amps complete all as specified and directed.
S&F in repair of aluminium bus bar PVC insulated in red,yellow, blue & black colours of rating 800 amps complete all as specified and directed.
S&F in repair of aluminium bus bar PVC insulated in red,yellow, blue & black colours of rating 1500 amps complete all as specified and directed.
M&L for taking down shutdown the LT panel and disconnecting the power cable for necessary repair and servicing of ACB 800 amps to 1600 amps including testing complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 (using 20 mm graded stone aggregates) for repairing of LT pole/ panel foundation etc including filling in road cuts/hard standing etc complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40 mm graded stone aggregates) for repairing of LT pole/ panel foundation etc including filling in road cuts/hard standing etc complete all as specified and directed.
S&F in repair of APFC relay for 10 KVAR 10 stages complete all as specified and directed.
BLANK
S&F in repair of capacitor bank MP-05 KVAR capacity rated 440 volts AC, 3 phase, 50 Hz delta connection round type complete all as specified and directed.
S&F in repair of capacitor bank MP-10 KVAR capacity rated 440 volts AC, 3 phase, 50 Hz delta connection round type complete all as specified and directed.
S&F in repair of capacitor, contactor MO C5 complete all as specified and directed.
S&F in repair of capacitor, contactor MO C12.5 complete all as specified and directed.
S&F in repair of capacitor, contactor MO C25 complete all as specified and directed.
S&F in repair of capacitor, contactor MO C50 complete all as specified and directed.
S&F in repair ON load change over switch 440 volts 4 pole of rating 400 amps with encloser fixed on wall/ panel including nut/bolts/washers complete all as specified and directed.
Taking down repairable potential transformer of HT VCB 11 kv/110v of any make opening & dismentaling the complete unit and refixing after carry out the following repairs / replacement:- (a) Rewinding of transformer as per existing gauge and pattern. (b) Cleaning and servicing of PT. (c) Replacement of wornout nuts/bolt other parts including HRC fuse. (d) Soldering/tightening of loose connections. (e) Replacement of potential transformer oil having dieletric strength upto 50kv. (f) Painting of outer portion of PT with synthetic enameled paint of grey colour of approved make. (g) Testing of the PT for proper funcing to the entire satisfaction of the Engr-in-charge.
S&F in replacement of potential transformer of HT VCB 11 kv/110 volts of existing make complete all as specified and directed.
M&L for preparation of new steel surface over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
INDIAN CONSTRUCTION CO.
Ish Engineers and Contractors
Pradeep Bros
M/S GUPTA ENTERPRISES
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .