Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.6 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹15 L+₹1.6 L (11.5%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹16.1 L+₹2.6 L (19.4%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹16.2 L+₹2.8 L (20.7%)Rejected-AOC B XXIII 56 A PREM NAGAR SAINGARGH PATHANKOT 145001 PUNJAB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-AOC L4 | |
| 5 | L5₹16.6 L+₹3.1 L (23.3%)Rejected-AOC HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L5 | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
4 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Jammu
HQ CWE Jammu Pin 900172 C/o 56 APO
REPAIR AND MAINT OF ELECTRIC SUPPLY CABLES AND ALLIED WORKS UNDER AGE E and M OF GE SATWARI
2021_MES_459418_1
CWE/JP-26/2021-22
Open Tender
Support/Maintenance Service
Item Rate
180 days
AOR of GE Satwari
Class E, Cat b(ii)
9 documents required · 9 mandatory
₹500
GE Satwari
₹40,000
Yes
28 Aug 2021
13 Jul 2021
11 Aug 2021
13 Jul 2021
4 Aug 2021
28 Jul 2021
90 days
Amount
Taking out serviceable/unserviceable XLPE HT/LT cable aluminum conductor of any size 2/3/4 core from excavated trench/pole/over ground etc and retreived material to store kept in safe custody for reuse at site or for taking credit of cable to be replaced with new one all as specified and dirrected. (Excavation, sand coushning, removing and return filling will be measured and paid saperately).
Taking out old bricks from excavated trenches, full bricks to be kept in safe custody for reuse at site. Broken bricks shall be removed by contractor at no extra cost, complete all as specified and as directed by Engineer-in-Charge.
Relaying of old serviceable cable of any size retrived from Sl Item No 1 above after repair, making proper jointing and making connection using thimbles/lugs of suitable size as required at site, complete all as specified and as directed by Engineer-in-Charge.
Taking out GI protection pipe from the pole /passsing through road/existing trenches for reuse at site or for taking credit of pipe to be replaced with new one all as directed, complete all as specified and as directed by Engineer-in-Charge.
Relaying of old serviceable GI pipe for cable protection in trenches/road/pole, complete all as specified and as directed by Engineer-in-Charge.
Relaying full bricks retrieved from Sl Item No 2 above for cable protection all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified and as directed.
Excavation in trenches in any type of soil not exceeding 1.5m wide and n.exc 1.5 mtr in depth for laying of under ground electric cable and getting out complete all as specified.
Sand cushioning to underground cables provided with a layer of sand 8cm thick before laying the cable in trenches and 15cm thick after laying the cable in trenches complete all as specified. Note:- 1.Dry fine sand of best available quality shall be used. 2.Punned thickness shall be measured and paid.
Supply and laying sub class `B` bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid, complete all as specified and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in any type of soil complete all as specified.
Removal of excavated surplus materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified.
Material and labour for replacement of double compression brass cable gland suitable for LT cable of size 25 to 95 sqmm 4 core, complete all as specified and as directed.
Material and labour for replacement of double compression brass cable gland suitable for LT cable of size 95 to 300 sqmm 4 core, complete all as specified and as directed.
Supply and laying for replacement of unserviciable underground LT cable of size 25 Sqmm, 3.5 core, 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium stranded conductor, Armoured confirming to IS-7098 Part-I (1988) with latest amendments, complete all as specified and as directed.
Supply and laying for replacement of unserviciable underground LT cable of size 35 Sqmm, 3.5 core, 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium stranded conductor, Armoured confirming to IS-7098 Part-I (1988) with latest amendments, complete all as specified and as directed.
Supply and laying for replacement of unserviciable underground LT cable of size 50Sqmm, 3.5 core, 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium stranded conductor, Armoured confirming to IS-7098 Part-I (1988) with latest amendments, complete all as specified and as directed.
Supply and laying for replacement of unserviciable underground LT cable of size 70 Sqmm, 3.5 core, 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium stranded conductor, Armoured confirming to IS-7098 Part-I (1988) with latest amendments, complete all as specified and as directed.
Supply and laying for replacement of unserviciable underground LT cable of size 95 Sqmm, 3.5 core, 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium stranded conductor, Armoured confirming to IS-7098 Part-I (1988) with latest amendments, complete all as specified and as directed.
Supply and laying for replacement of unserviciable underground LT cable of size 120 Sqmm, 3.5 core, 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium stranded conductor, Armoured confirming to IS-7098 Part-I (1988) with latest amendments, complete all as specified and as directed.
Supply and laying for replacement of unserviciable underground LT cable of size 150 Sqmm, 3.5 core, 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium stranded conductor, Armoured confirming to IS-7098 Part-I (1988) with latest amendments, complete all as specified and as directed.
Supply and laying for replacement of unserviciable underground LT cable of size 240 Sqmm, 3.5 core, 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium stranded conductor, Armoured confirming to IS-7098 Part-I (1988) with latest amendments, complete all as specified and as directed. Note for Sl Item No 15 to 22 :- Earthwork and excavation for Sl Item No 15 to 22 Shall be measured and paid seperately in the respective item of this schedule.
Material and labour in replacement of cable straight through type jointing kit outdoor type, heat shrinkable including all jointing material & accessories suitable for 1100 Volt grade aluminium conductor cables of size 25 to 35 Sqmm 4/3.5 core cables, complete all as specified and as directed.
Material and labour in replacement of cable straight through type jointing kit outdoor type, heat shrinkable including all jointing material & accessories suitable for 1100 Volt grade aluminium conductor cables of size 50 to 95 Sqmm 4/3.5 core cables, complete all as specified and as directed.
Material and labour in replacement of cable straight through type jointing kit outdoor type, heat shrinkable including all jointing material & accessories suitable for 1100 Volt grade aluminium conductor cables of size 120 to 185 Sqmm 4/3.5 core cables, complete all as specified and as directed.
Material and labour in replacement of cable straight through type jointing kit outdoor type, heat shrinkable including all jointing material & accessories suitable for 1100 Volt grade aluminium conductor cables of size 240 to 300 Sqmm 4/3.5 core cables, complete all as specified and as directed.
Supply and fixing for replacement of GI steel tubing light grade complete under Road, Path drain, fixed on walls etc of size 100mm bore, complete all as specified and as directed.
Supply and fixing for replacement of GI steel tubing light grade complete under Road, Path drain, fixed on walls etc of size 80mm bore, complete all as specified and as directed.
Supply and fixing for replacement of GI steel tubing light grade complete under Road, Path drain, fixed on walls etc of size 40mm bore, complete all as specified and as directed.
Supply laying and testing for replacement of XLPE insulated, Armoured, electric cable heavy duty with alumimium conductor 11000 volt (Earthed) grade of size 95 Sqmm x 3 core, complete all as specified and as directed.
Supply laying and testing for replacement of XLPE insulated, Armoured, electric cable heavy duty with alumimium conductor 11000 volt (Earthed) grade of size 120 Sqmm x 3 core complete all as specified and directed.
Supply laying and testing for replacement of XLPE insulated, Armoured, electric cable heavy duty with alumimium conductor 11000 volt (Earthed) grade of size 185 Sqmm x 3 core complete all as specified and directed.
Supply laying and testing for replacement of XLPE insulated, Armoured, electric cable heavy duty with alumimium conductor 11000 volt (Earthed) grade of size 240 Sqmm x 3 core complete all as specified and directed.
Supply and Fixed for replacement of outdoor type cable end termination jointing kit heat shrinkable complete with all accessories and jointing materials suitable mounting on channel/angle iron for 3 core 50 to 95Sqmm XLPE HT cable (kit shall be not older than 3 months from the date of manufacture), complete all as specified and directed.
Supply and Fixed for replacement of indoor type cable end termination jointing kit heat shrinkable complete with all accessories and jointing materials suitable mounting on channel/angle iron for 3 core 50 to 95 Sqmm XLPE HT cable (kit shall be not older than 3 months from the date of manufacture), complete all as specified and directed.
Supply and Fixed for replacement of outdoor type cable straight through jointing kit heat shrinkable complete with all accessories and jointing materials with and incl cable pieces of suitable size length and line type size for 3 core 50 to 95 Sqmm XLPE HT cable (kit shall be not older than 3 months from the date of manufacture), complete all as specified and directed.
Supply and Fixed for replacement of outdoor type cable end termination jointing kit heat shrinkable complete with all accessories and jointing materials suitable mounting on channel/angle iron for 3 core 120 to 185 Sqmm XLPE HT cable (kit shall be not older than 3 months from the date of manufacture), complete all as specified and directed.
Supply and Fixed for replacement of indoor type cable end termination jointing kit heat shrinkable complete with all accessories and jointing materials suitable mounting on channel/angle iron for 3 core 120 to 185 Sqmm XLPE HT cable (kit shall be not older than 3 months from the date of manufacture), complete all as specified and directed.
Supply and Fixed for replacement of outdoor type cable straight through jointing kit heat shrinkable complete with all accessories and jointing materials with and incl cable pieces of suitable size length and line type size for 3 core 120 to 185 Sqmm XLPE HT cable (kit shall be not older than 3 months from the date of manufacture), complete all as specified and directed.
Supply and Fixed for replacement of outdoor type cable end termination jointing kit heat shrinkable complete with all accessories and jointing materials suitable mounting on channel/angle iron for 3 core 240 Sqmm XLPE HT cable (kit shall be not older than 3 months from the date of manufacture), complete all as specified and directed.
Supply and Fixed for replacement of indoor type cable end termination jointing kit heat shrinkable complete with all accessories and jointing materials suitable mounting on channel/angle iron for 3 core 240 Sqmm XLPE HT cable (kit shall be not older than 3 months from the date of manufacture) complete all as specified and directed.
Supply and Fixed for replacement outdoor type cable straight through jointing kit heat shrinkable complete with all accessories and jointing materials with and incl cable pieces of suitable size length and line type sizee for 3 core 240 Sqmm XLPE HT cable (kit shall be not older than 3 months from the date of manufacture), complete all as specified and directed.
Supply and Fixed for replacement of 1100 volt grade heavy duty cable 6 sqmm, 2 core flat or circular, PVC insulated aluminium conductor as in service connections suspended by insulated hangers not more than 1.0 m apart with and including 4mm dia GI wire, suspension wire, complete all as specified and directed.
Supply and Fixed for replacement of 1100 volt grade heavy duty cable 10 sqmm, 2 core flat or circular, PVC insulated aluminium conductor as in service connections suspended by insulated hangers not more than 1.0 m apart with and including 4mm dia GI wire, suspension wire, complete all as specified and directed.
Supply and Fixed for replacement of 1100 volt grade heavy duty cable 16 sqmm, 2 core flat or circular, PVC insulated aluminium conductor as in service connections suspended by insulated hangers not more than 1.0 m apart with and including 4mm dia GI wire, suspension wire, complete all as specified and directed.
Disconnecting HT supply from HT panel / 2 pole / 4 pole structures / transformer and reconnecting HT supply and testing complete. Locating the fault through cable fault locating machine to pin point the exact location of the fault length cable (200RM to 1000RM), complete all as specified and directed by Engr - in - Charge.
M/S ASHOK KUMAR SURI
M/S S K Electricals Regd
SATISH AND CO
SUMEET TRADING CORPORATION
kailu construction co
bamral builder
vishesh engineers
LAL CONSTRUCTIONS
R K BUILDERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .