| 1 | L1₹21.4 LAccepted-AOC 520C MAIN ROAD WARD NO 12 METTU STREET ELAMBALUR PERAMBALUR | PERAMBALUR | PERAMBALUR | TAMIL NADU | 621220 | ₹21.4 L Quoted ₹21.8 L | L1 | Accepted-AOC Lowest value |
| 2 | L2₹24.0 LRejected-Finance | ₹24.0 L | L2 | Rejected-Finance highest value |
| Sl No | Description | Qty | Unit | sri diksha electricals L2 | KDM BUILDERS AND CONTRACTORS L1 |
|---|---|---|---|---|---|
| 1.00EXCAVATION of POLE/STAY PIT | |||||
| 2.00 | Excavation of pole pit upto 27" (8.0 m ) Pole by using JCB or manual | 250 | Each Pit | 450 ₹1.1 L | 450 ₹1.1 L |
| 3.00 | Excavation of pole pit upto 30" RCC Pole / (9.0 m ) Pole by using JCB or manual | 150 | Each Pit | 550 ₹82,500 | 500 ₹75,000 |
| 4.00 | Excavation of stay pit 4.5' to 5' depth by using JCB or manual | 300 | Each | 450 ₹1.4 L | 450 ₹1.4 L |
| 5.00 | Erection of PSC/RCC Pole upto 8.0m (27") by using crane or manual | 250 | Each | 550 ₹1.4 L | 540 ₹1.4 L |
| 6.00 | Erection of PSC/RCC Pole upto 9.14m (30") by using crane or manual | 150 | Each | 650 ₹97,500 | 630 ₹94,500 |
| 7.00 | Erection of Stay set complete | 300 | Each | 240 ₹72,000 | 210 ₹63,000 |
| 8.00 | Fixing of HT V cross arms | 200 | Each | 180 ₹36,000 | 162 ₹32,400 |
| 9.00 | Channel cross arms / guarding Cross arm | 20 | Each | 200 ₹4,000 | 162 ₹3,240 |
| 10.00 | Fixing of LT 3Ph cross arm | 550 | Each | 120 ₹66,000 | 100 ₹55,000 |
Tender Value
Refer Docs
EMD Value
₹25,000
Closing Date
28 Jan 2026, 2:30 pmClosed
SE/SEDC/Udayapatty/Salem
O/o The SE/SEDC/SALEM
Works contract for Thammampatty Sub Division in Gangavalli Division
2026_EB_643144_1
SE/SEDC/WC.047/25-26 dt.8.1.26
Open Tender
Electrical and Maintenance Works
365 days
Gangavalli
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹25,000
11 Jun 2026
13 Jan 2026
29 Jan 2026
13 Jan 2026
28 Jan 2026
13 Jan 2026
Excavation of pole pit upto 27" (8.0 m ) Pole by using JCB or manual
Excavation of pole pit upto 30" RCC Pole / (9.0 m ) Pole by using JCB or manual
Excavation of stay pit 4.5' to 5' depth by using JCB or manual
Erection of PSC/RCC Pole upto 8.0m (27") by using crane or manual
Erection of PSC/RCC Pole upto 9.14m (30") by using crane or manual
Erection of Stay set complete
Fixing of HT V cross arms
Channel cross arms / guarding Cross arm
Fixing of LT 3Ph cross arm
Fixing of LT 1Ph cross arm
Fixing of HT/LT TI Fittings
Fixing of HT Pin Insulators (11/22/33KV)
Fixing of HT Strain Disc 22KV
Fixing of LT Pin insulators
Fixing of LT Shackle
Fixing of Aluminium Knob
Paving and stringing of 7/3.35 mm ACSR, 7/3.30mm AAAC
Paving and stringing of 7/2.59 mm ACSR, 7/2.59mm ACSR
Earthing of pole with pin and cross arm including burying looping and binding.
Erection of Double Pole Transformer structure completed in all respects with wiring Earthing ,fixing of open type fuse units, HT/LT/LAS, structure poles, fixing of top channel seating channel, belting angle (Except erection of transformer)
Erection of Single Pole Transformer structure complete in all respects with wiring, Earthing, fixing of open type fuse units, HT/LT LAS and jumpering 3 Nos. Earth pit with collar including painting of metal parts, structure poles, fixing of tapping channel, transformer bed structure including concreting (Except erection of Transformer)
Transport of Materials. Below 8 Kms.
Transportation of Poles from road side to pole Pit up to 1.0 KM 7.5/8.0m (RCC &PSC Poles)
Transportation of Poles from road side to pole Pit up to 1.0 KM 9.14m & 9.00 Mtr (RCC&PSC Poles)
Loading of poles upto 27'-0"
Unloading of poles upto 27'
loading of poles upto 30'/RSJ pole
Unloading of poles upto 30'/RSJ pole
Loading or unloading of line Material
Loading & unloading of Transformer upto 200 KVA for each
Erection of New Transformer upto 200 KVA
Replacement of failed Transformers upto 200 KVA
Drilling of hole in channel only 3/4" & 1" per hole
Cutting of channel
Releasing of grills from RCC Poles/PSC Poles
Dismantling of RCC pole 9.14mtr/RSJ pole
Dismantling of RCC/PSG pole 8.0mtr/7.5mtr
Dismantling of 'V' X arm)
Channel X arm, Guarding X arm (all types)
Dismantling of LT 3 phase X arm
Dismantling of LT single phase X arm
Dismantling of HT/LT TI fitting
Dismantling of 22KV strain disc
Dismantling of 22KV pin insulator
Dismantling of LT shackle
Dismantling of LT pin insulator
Dismantling of Aluminium knob
Dismantling of stay set
Dismantling of ACSR 7/3.35mm conductor
Dismantling of ACSR 7/2.59mm/ 7/2.11mm conductor
Pole concreting
Relesing and reusing Single phase service wire
Relesing and reusing three phase service wire
Erection of street light fitting and service
G.S.T. @18% should be Entered by the Bidder
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
BOQ_770644.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid