Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.4 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED BEING LOWEST BIDDER | |
| 2 | L2₹31.8 L+₹2.8 L (9.68%)Rejected-Finance | L2 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 3 | L3₹37.2 L+₹8.2 L (28.3%)Rejected-Finance FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L3 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 4 | L4₹40.0 L+₹11.0 L (38.0%)Rejected-Finance 1 NEAR AKBARIYA MASJID WIMBERLYGUNJ SOUTH ANDAMAN ANDAMAN NICOBAR 744206 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744206 | L4 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 5 | L5₹40.4 L+₹11.5 L (39.6%)Rejected-Finance SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L5 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER |
| Sl No | Description | Qty | Unit | Mahindra Electric Stores L7 | Nexus Infratech L1 | Priyanka Power line L6 | Rama Electricals L5 | SKS Electricals L3 | Sunhari Electricals L2 | SBS Enterprises L4 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | S&F in replacement Switch Air break Gang operated HT 22 KV Volt grade out door type, triple pole of capacity 200 amps rating mounted on Polymer based 9 insulator and fitted on steel frame horizontally mechanically operated mechanism from ground level consisting of operating rod of 25 mm bore Heavy grade GI pipe of suitable length worked from ground level and with locking arrangements incl pad locks with key flat iron clamp 50 mm x 6 mm including taking down old unserviceable one complete all as specified and as directed by Engr-in-charge.
Make: Atlas /Jaipuria Brothers / MEC Trivandrum/Pactil | 1 | Each | 22,500 ₹22,500 | 13,000 ₹13,000 Lowest | 26,700 ₹26,700 | 26,500 ₹26,500 | 16,000 ₹16,000 | 18,000 ₹18,000 | 24,500 ₹24,500 |
| 2.00 | Supplying, installing, fixing, connecting and testing of Polymer based Drop-out fuse set (set of 3 nos), mounted on insulators with steel frame 200 Amps capacity, suitable for 22 KV, HT system, out door type, including Expulsion fuse carriers and fuse element Upto 25 Amp, including taking down old unserviceable one complete.
Make: Atlas /Jaipuria Brothers / MEC Trivandrum/Pactil | 1 | Each | 12,500 ₹12,500 | 7,500 ₹7,500 Lowest | 18,700 ₹18,700 | 16,500 ₹16,500 | 8,000 ₹8,000 | 9,000 ₹9,000 | 9,100 ₹9,100 |
| 3.00 | M&L for Lightning arrester high tension expulsion type complete in repair with all fittings transmission class, discharge capacity 30 Kilo amps suitable for 22000 Volts supply including taking down old lightning arresters complete all as specified and as directed by Engr-in-charge.
Make: Elpro/ Jayshree / Mysore/Areva | 2 | Set of three | 5,000 ₹10,000 | 3,200 ₹6,400 Lowest | 4,800 ₹9,600 | 6,500 ₹13,000 | 5,000 ₹10,000 | 3,600 ₹7,200 | 3,850 ₹7,700 |
| 4.00 | M&L for Lightning arrester high tension expulsion type complete in repair with all fittings transmission class, discharge capacity 30 Kilo amps suitable for 11000 Volts supply including taking down old lightning arresters complete all as specified and as directed by Engr-in-charge.
Make: Elpro/ Jayshree / Mysore/Areva | 2 | Set of three | 5,000 ₹10,000 | 2,800 ₹5,600 | 4,500 ₹9,000 | 6,500 ₹13,000 | 5,000 ₹10,000 | 2,400 ₹4,800 Lowest | 3,500 ₹7,000 |
| 5.00 | Taking down unserviceable / damaged HT cable of 11KV/22 KV, of size 95 Sqmm and 120 Sqmm from the trench /pole/wall complete all as specified and as directed by Engr-in-charge.
Note:- Earth work shall be measured and paid separately under relevant item of schedule. | 390 | RM | 50 ₹19,500 | 1 ₹390 Lowest | 20 ₹7,800 | 5 ₹1,950 | 6 ₹2,340 | 10 ₹3,900 | 14 ₹5,460 |
| 6.00 | Supply and laying of HT underground cable XLPE insulated, PVC bedded round wire armoured electric power cable heavy duty with stranded aluminium conductor 22000 volts grade and cross section area 95 sqmm 3 core confirming to IS 7098/(part-II) 1985 laid in trenches/passing through pipes or fixed on poles/wall/floor etc complete all as specified and as directed by Engr-in-charge. | 35 | RM | 1,275 ₹44,625 | 1,440 ₹50,400 | 1,475 ₹51,625 | 1,727 ₹60,445 | 1,100 ₹38,500 Lowest | 1,200 ₹42,000 | 1,470 ₹51,450 |
| 7.00 | Supply and laying of HT underground cable XLPE insulated, PVC bedded round wire armoured electric power cable heavy duty with stranded aluminium conductor 22000 volts grade and cross section area 120 sqmm 3 core confirming to IS 7098/(part-II) 1985 laid in trenches/passing through pipes or fixed on poles/wall/floor etc complete all as specified and as directed by Engr-in-charge. | 120 | RM | 1,475 ₹1,77,000 | 1,620 ₹1,94,400 | 1,675 ₹2,01,000 | 1,941 ₹2,32,920 | 1,200 ₹1,44,000 Lowest | 1,320 ₹1,58,400 | 1,680 ₹2,01,600 |
| 8.00 | Supply and laying of HT underground cable XLPE insulated, PVC bedded round wire armoured electric power cable heavy duty with stranded aluminium conductor 22000 volts grade and cross section area 300 sqmm 3 core confirming to IS 7098/(part-II) 1985 laid in trenches/passing through pipes or fixed on poles/wall/floor etc complete all as specified and as directed by Engr-in-charge. | 30 | RM | 2,100 ₹63,000 | 2,890 ₹86,700 | 2,750 ₹82,500 | 3,478 ₹1,04,340 | 2,000 ₹60,000 | 1,860 ₹55,800 Lowest | 2,772 ₹83,160 |
| 9.00 | Supply and laying of HT underground cable XLPE insulated, PVC bedded round wire armoured electric power cable heavy duty with stranded aluminium conductor 11000 volts grade and cross section area 95 sqmm 3 core confirming to IS 7098/(part-II) 1985 laid in trenches/passing through pipes or fixed on poles/wall/floor etc complete all as specified and as directed by Engr-in-charge. | 205 | RM | 1,250 ₹2,56,250 | 1,045 ₹2,14,225 | 1,050 ₹2,15,250 | 1,252 ₹2,56,660 | 900 ₹1,84,500 Lowest | 960 ₹1,96,800 | 1,106 ₹2,26,730 |
| 10.00M & L for cable jointing kit for 22 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size and voltage grade including taking down old cable joint kit complete all as specified and as directed by Engr-in-charge. | ||||||||||
Tender Value
₹55 L
EMD Value
₹1.1 L
Closing Date
26 Apr 2025, 6:00 pmClosed
CWE Khadki Pune
Headquarters CWE Khadki, Military Engineer Services, Range Hills Road, Khadki, Pune-411003
REPAIR MAINT OF HT DISTRIBUTION SYSTEM SERVICING OF HT BREAKERS VCB RMUS AND TRANSFORMERS INCLUDING MAINTENANCE OF E M INSTALLATION AT RANGE HILLS AREA AND REPAIR AND MAINTENANCE OF APFC PANEL HT EXTERNAL ELECTRIC SUPPLY DISTRIBUTION SYSTEM INCL
2025_MES_702045_1
CWE/KKE/TOKEN-46 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
CWE Khadki Pune
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹1,000
GE MH AND RH KHADKI
₹1.1 L
Yes
30 Aug 2025
20 Mar 2025
28 Apr 2025
20 Mar 2025
26 Apr 2025
12 Apr 2025
20 Mar 2025 - 6 Apr 2025
Amount
S&F in replacement Switch Air break Gang operated HT 22 KV Volt grade out door type, triple pole of capacity 200 amps rating mounted on Polymer based 9 insulator and fitted on steel frame horizontally mechanically operated mechanism from ground level consisting of operating rod of 25 mm bore Heavy grade GI pipe of suitable length worked from ground level and with locking arrangements incl pad locks with key flat iron clamp 50 mm x 6 mm including taking down old unserviceable one complete all as specified and as directed by Engr-in-charge. Make: Atlas /Jaipuria Brothers / MEC Trivandrum/Pactil
Supplying, installing, fixing, connecting and testing of Polymer based Drop-out fuse set (set of 3 nos), mounted on insulators with steel frame 200 Amps capacity, suitable for 22 KV, HT system, out door type, including Expulsion fuse carriers and fuse element Upto 25 Amp, including taking down old unserviceable one complete. Make: Atlas /Jaipuria Brothers / MEC Trivandrum/Pactil
M&L for Lightning arrester high tension expulsion type complete in repair with all fittings transmission class, discharge capacity 30 Kilo amps suitable for 22000 Volts supply including taking down old lightning arresters complete all as specified and as directed by Engr-in-charge. Make: Elpro/ Jayshree / Mysore/Areva
M&L for Lightning arrester high tension expulsion type complete in repair with all fittings transmission class, discharge capacity 30 Kilo amps suitable for 11000 Volts supply including taking down old lightning arresters complete all as specified and as directed by Engr-in-charge. Make: Elpro/ Jayshree / Mysore/Areva
Taking down unserviceable / damaged HT cable of 11KV/22 KV, of size 95 Sqmm and 120 Sqmm from the trench /pole/wall complete all as specified and as directed by Engr-in-charge. Note:- Earth work shall be measured and paid separately under relevant item of schedule.
Supply and laying of HT underground cable XLPE insulated, PVC bedded round wire armoured electric power cable heavy duty with stranded aluminium conductor 22000 volts grade and cross section area 95 sqmm 3 core confirming to IS 7098/(part-II) 1985 laid in trenches/passing through pipes or fixed on poles/wall/floor etc complete all as specified and as directed by Engr-in-charge.
Supply and laying of HT underground cable XLPE insulated, PVC bedded round wire armoured electric power cable heavy duty with stranded aluminium conductor 22000 volts grade and cross section area 120 sqmm 3 core confirming to IS 7098/(part-II) 1985 laid in trenches/passing through pipes or fixed on poles/wall/floor etc complete all as specified and as directed by Engr-in-charge.
Supply and laying of HT underground cable XLPE insulated, PVC bedded round wire armoured electric power cable heavy duty with stranded aluminium conductor 22000 volts grade and cross section area 300 sqmm 3 core confirming to IS 7098/(part-II) 1985 laid in trenches/passing through pipes or fixed on poles/wall/floor etc complete all as specified and as directed by Engr-in-charge.
Supply and laying of HT underground cable XLPE insulated, PVC bedded round wire armoured electric power cable heavy duty with stranded aluminium conductor 11000 volts grade and cross section area 95 sqmm 3 core confirming to IS 7098/(part-II) 1985 laid in trenches/passing through pipes or fixed on poles/wall/floor etc complete all as specified and as directed by Engr-in-charge.
M & L for cable jointing kit for 22 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size and voltage grade including taking down old cable joint kit complete all as specified and as directed by Engr-in-charge.
95 sqmm x 3 core
120 sqmm x 3 core to 185 Sqmm x 3 Core
240 Sqmm 3 Core to 300 sqmm x 3 core
M & L for cable jointing kit for 22 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size including taking down old cable joint kit complete all as specified and as directed by Engr-in-charge.
95 sqmm x 3 core
120 sqmm x 3 core to 185 Sqmm x 3 Core
240 Sqmm 3 Core to 300 sqmm x 3 core
M & L for heat shrinkable HT 22 KV (earthed) straight through joint cable kit suitable for aluminium conductor cable of following size complete all as specified and as directed by Engr-in-charge.
95 sqmm x 3 core
120 sqmm x 3 core to 185 Sqmm x 3 Core
M & L for cable jointing kit raych 22 KV Touch proof kit for HT 22 KV (Earthed) grade cable for indoor type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm to 300 Sqmm including taking down old cable joint kit complete all as specified and as directed by Engr-in-charge.
M & L for cable jointing kit for HT 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm including taking down old cable joint kit complete all as specified and as directed by Engr-in-charge.
M & L for cable jointing kit for 11 KV of Size upto 3 core 95 sqmm (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm including taking down old cable joint kit complete all as specified and as directed by Engr-in-charge.
M & L for heat shrinkable HT 11 KV (earthed) straight through joint of size upto 95 Sqmm cable kit suitable for aluminium conductor cable of size upto 95 sqmm 3 core complete all as specified and as directed by Engr-in-charge.
M&L for cable route indicator made out of Cast iron of dia 100 mm embossed with HT cable with 25mm x 5 mm GI flat of length 1 mtr including painting with two coats of synthetic enamel red colour paint over a coat of primer to exposed surfaces complete all as specified and as directed by Engr-in-charge.
M & L for detect HT 11 KV/22 KV cable fault for various size of cable with technician around the clock at CQA (FEE), CQE(EE), CQE(tech area) CQA (ME) , HT sub stations at all Insp Org area and other locations under GE (MH & RH) Khadki detect the cable fault including necessary excavation in any type of soil ,returning, refilling the soil, joint the faulty cable with new straight through joint kit, after jointing, testing, and charging of HT cable complete all as specified and as directed by Engr-in-charge. Note:- (i) Cable joint of required size shall be measured and paid separately under relevant item of this BOQ (ii) Each job considered cable fault locator use in one day
Material & labour for erecting in repair steel tubular swaged poles in true vertical position ( or to be fixed in an inclined position as strut pole) steel tubular swaged poles complete with MS base plate of 6 mm thick of size 450x450 mm finial taper plug , pole cap, bolts ,nuts and washer and screwed pole made out of ERW MS tubing confirming to IS -2713 (part-II) 1980 type 410 SP-55 (11 meters long) pole including drilling of holes of required size and Nos for fixing of cross arms, and applying two coats of aluminium paint to exposed surfaces over a coat of red oxide primer and applying two coats of black bituminous paint for portion embedded in concrete, etc complete all as specified and as directed. Note: Excavation , earth work and PCC shall be measured and paid for separately under relevant item of this BOQ.
Material and labour in repair for cross arms, bracing, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washer, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or as directed and applying two coats of aluminium paint for exposed surfaces over a coat of red oxide primer complete all as specified and as directed by Engr-in-charge.
M&L cement concrete M-7.5 grade(Nominal Mix) , using 40 mm graded stone aggregate for pole/struts, stay assembly, foundation filling and mass concrete complete all as specified and as directed by Engr-in-charge.
M&L cement concrete M-10 grade (Nominal Mix) using 20 mm graded stone aggregate as in coping of pole etc complete all as specified and as directed by Engr-in-charge.
M&L for applying two coat of synthetic enamel paint heat resistant paint of same colour including preparation of old surfaces of Transformers of capacity upto 500 KVA complete including writing the MES No, SM No & capacity of transformer in bold letter complete all as specified and as directed by Engr in charge .
M&L for applying two coat of aluminium paint over a coat of red oxide primer after preparation of old surfaces on two pole structure along with connected MS stays, bracings, C-channels complete at height upto 11 mtrs complete as existing and complete all as specified and as directed by Engr-in-charge.
M&L for applying two coat of aluminium paint over a coat of red oxide primer after preparation of old surfaces on on four pole structure with connected MS stays, bracings, C- channels complete at height upto 11m including complete removal of old paint, filling cavities with filler on exposed surface of steel complete all as specified and as directed by Engr-in-charge.
M&L for applying two coats of synthetic enamel aluminium paint(as per existing colour) over a coat of red oxide primer including preparation of old painted surface by scrapping or complete removal of old paint, filling cavities with filler on exposed surface of steel tubular pole (HT pole) 11m long complete all as specified and as directed by Engr-in-charge.
Disconnecting the HV side 22 KV & LV side 0.415KV of transformer and removing electrical connections including neutral earth strip of existing step down transformer, drain out the complete oil of transformer and store carefully in clean container. Cleaning of all HV/LV windings terminals, cleaning of conservator tank, cooling fins/tubes, tank, etc. Thoroughly inspecting of core and winding complete, reinsert the core coil assembly into the transformer tank, replacing 5/3 mm thick rubberised cork sheet gasket of top cover complete and refilled with filtered transformer oil upto the desired level marked in conservator tank and record the insulation resistance of the winding both HV/LV side between earth and HV/LV winding, reconnecting the HV/LV side electric cables complete of following capacity of step-down transformer. Note - Transformer oil filtration and top up shall be measured and paid separately under the relevant item of this BOQ.
Transformer capacity 100KVA to 250 KVA
Transformer capacity 300KVA to 500 KVA
M&L for dehydration of transformer oil with mobile stream line transformer oil filtration plant at site with all accessories connected to transformer and carrying out filtration of oil to desired dielectric strength to achieve electric strength of 60 KV for 1 minute at 2.5 mm gap as per relevant IS for transformer installed at various locations out door/in door type, complete all as specified and as directed by Engr-in-charge. Note : (i)Test certificate shall be submitted for before and after filtration for dielectric strength on the proper format. (ii) Transformer oil used for top up will be measured and paid separately under relevant item.
Supply and topping up new transformer oil confirming to IS-335 of 1993 into the conservator tank/body tank of the transformer at various location complete all as specified and as directed by Engr-in-charge. Make : Power Oil or its equivalent make as approved by GE Note : The transformer oil for topping up shall be with di-electric strength of 60KV
Disconnecting all in coming and outdoor cables removing the transformer from the platform/two pole structure and floor and loading it in the vehicle carefully using the crane and transporting it to the workshop for repairs and transformer transport back to site , reinstall it, reconnecting all incoming and outgoing cable by properly crimping using lugs of suitable size taping the bushes/busbar, using insulation tape and testing of capacity 200 KVA to 500 KVA complete all as specified and as directed by Engr-in-charge. Note :LT/HT side ceramic busing, brass spindle for HT/LT side , Rewinding , Dehydration of oil shall be measured and paid separately in respective Items
Material and Labour for rewinding of HT /LT windings of transformer , winding the defective coils with approved quality copper wire as per IS of same gauge and existing size together with new insulation materials, bracings the terminals before placing into the transformer and assembling the HT / LT coil with new insulation between core and LT coil all as required and fitting the coils in the chamber, testing and commissioning the transformer after providing necessary connections complete all as directed by Engr in charge.
Material and Labour for arrest the leakage of transformer oil from Transformer of capacity upto 500 KVA from the LT/HT side bushings by replacing oil seals , Gaskets of , top cover , conservator tank and other parts of transformer after drain out the transformer at required level , tightening the transformer nut bolts, replacing the gasket nuts , bolts , washer and refilling the stored Transformer oil after completion of oil arrest complete all as specified and as directed by Engr-in-charge. Note:- (i) Spare required such as nut ,bolts,washer,Gasket etc required to oil arrest shall be deemed to be included under unit rate quoted. (ii) Topping up of extra transformer oil required to achieve desired level measured and paid separately under relevant item of this BOQ (Schedule). (iii) HT/LT side complete bushing assemble with brass stud & oil seal shall be measured & paid under relevant item of this BOQ (Schedule).
Supply only HT side bushing 22KV complete with oil seal for 100 to 250 KVA
Supply only HT side bushing 22KV complete with oil seal for 300 to 500 KVA
Supply only LT side bushing 415V complete with oil seal for 100 to 250 KVA
Supply only LT side bushing 415V complete with oil seal for 300 to 500 KVA
M & L in repair for Ashida numerical self powered protection relay ( Over current/ earth fault relay) from the HT VCB of 800 Amps capacity with model No. ADR241S(ASHIDA) including making the relay setting as per the setting given by MESB and taking the trail complete all as specified and as directed by Engr-in-charge.
Replacement of breather assembly complete with silica jel in transparent container with metallic top and bottom cup with pipe entry of 15/20 mm dia, including oil bath tub .
Replacement of existing unserviceable silica gel with new crystal clear silica jel for breather of transformer all as directed.
Supply only brass spindle on LT side as per existing size, shape and specification for capacity range 200 KVA to 500 KVA , complete all as directed by the Engineer-in-charge.
Supply only brass spindle on HT side 22 KV as per existing size, shape and specification for capacity range 200 KVA to 500 KVA , complete all as directed by the Engineer-in-charge.
M & L for overhauling servicing of Tap changer and replacement of unserviceable parts as ordered with new and assembling with old serviceable parts for smooth functioning and operation complete as all specified and directed.
M & L for Servicing HT 22 KV HT RMU (Ring Main Unit), type - RM6, of capacity 630A/800A,22KV, 3 ph,50 Hz Panel, comprising the following works. Make-C&S Note:- (i) check the auxiliary switch, shunt trip assembly, closing/Trip solenoid, limit switch and complete control wiring (ii) Major Spares required for the servicing/overhauling of the RMU shall be measured & paid separately under relevant items of the schedule.
Over hauling and testing of secondary injection of over current and earth fault relay of HT RMU 22 KV panel on each multiple setting , readjustment and calibration the same complete, checking of control wiring including testing on complete all as specified and as directed by Engr-in-charge.
Supply only of the following material for VCBs/RMU complete all as specified and as directed by Engr-in-charge.
Charging motor, single phase working on 240 volts Ac
Closing/tripping coil operated on 110 /30 volt system
Tripping coil operated on 110 /30 volt system
Loading Spring
Latch switch assly
Space heater
Thermostat for Space heater
Refilling onsite SF6 Gas, required for 22 KV VCBs/RMUs
Excavating in trenches n.exc 1.50 m wide and not exc 1.5 m depth and getting out in soft / loose soil complete all as specified and directed by engineer-in-Charge.
Excavating in trenches n.exc 1.50 m wide and not exc 1.5 m depth and getting out in hard / dense soil complete all as specified and directed by engineer-in-Charge.
Excavating in trenches n.exc 1.50 m wide and exc 1.5 m depth and getting out in soft disintegrated soil complete all as specified and directed by engineer-in-Charge.
Returning, filling in including spreading levelling, watering and well ramming in layers not exc 25 cm in soil all as specified and directed.
Removing excavated materials not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point.
M&L for crushed stone grid for cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr in charge. Note:- (i) Measurement shall be taken after gentling punning. (ii) The sand to be laid in cable ducts shall be measured as per the site conditions. (iii) The rates are inclusive of cleaning the cable ducts and removing the old sand as directed.
Supplying and laying reinforced precast concrete cable cover, class EHV, type-1, peak of size 450mmx230mmx50mm laid in trench as protection to cable all as specified and directed
M & L for road cutting for laying GI pipe for protection of cable upto depth 90 cm incl including making good the disturbed road and redressing the disturb surfaces of road filling with concrete M-7.5 grade using 40 mm graded stone aggregate complete all as specified and directed
Supply and fixing GI pipe Light grade (ISI marked) in repair laid in trenches/ path /road crossings/ fixed to poles/ceiling/ along walls/ path /drain/floors with and including all necessary clamps, nuts, bolts, washers etc and all fittings as required, complete all as specified and as directed by the Engineer-in-Charge of following sizes :-
100 mm bore
80 mm bore
Material and labour of Synthetic insulating mat confirming to IS 15652:2006 of size 2mx1m, 3 mm thick for voltage up to 22/33kv all as specified and directed by Engr in charge.
Material and labour of Synthetic insulating mat confirming to IS 15652:2006 of size 2mx1m ,3 mm thick for voltage up to 11 kv all as specified and directed by Engr in charge.
M& L for trimming of tree branches with in 2.0 mtr on either side of the electric line/ poles with suitable T & P and depositing the waste as directed. Note:- Measurements shall be taken once in entire period of contract.
M&L for cleaning of MES electric supply installations/campus/complaint cell area by surface dressing or trimming of natural ground to remove small inequalities (including removing vegetation/ shrubs/brush wood/under growth) and carrying away the rubbish to a distance of not exc 50 mtr away complete for the various sub stations. Note:- Measurements shall be taken once in entire period of contract.
M&L for hardcore of gauge n.exc 63 mm ,deposited, spread, and levelled in layers n.exc 15 cm thickness (below or above ground level),water and rammed to a true shape with broken stone or boulders existing available on site and making good all as specified and directed by Engr-in-Charge. ( Sub Station Yard)
Disconnecting and dismantling the existing indoor type, 11 KV horizontal draw out type VCB trolley of rupturing capacity 250/350 MVA, 400/630/800 Amps from location and repair /overhauling servicing and carrying out with the following activities as mentioned below complete all as specified and directed by Engineer-in-Charge. (i) Inspecting / overhauling servicing of manual / motorised spring drive mechanism by checking mechanism, motor and gear assembly, big gear assembly, stop bolt assembly, main shaft interlocking assembly, closing spring assembly, small cam with screw, motor cut -off limit switch, butter fly switch assembly and apply multi grease lubricant to function smoothly. (ii) Inspecting / overhauling of tripping assembly,earthfault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system. (iii) Inspecting / overhauling /cleaning and inspecting through insulators, vacuum interrupters by carbon cleaner solution and apply dry graphite conductive sealant for electrical contacts to avoid carbon deposits on contact surfaces. (iv) Assembling all items/components parts to the respective position & testing the breaker with High Voltage(DC) and meggering before and after high voltage test complete. (v) Cleaning all busbar by rubbing and by CRC liquid cleaner. (vi)Spraying two coat of anti track paint on CTs. (vi) Applying insulating boots for busbar and cables. (vii) Supply and fixing all missing nut bolts for panels. (viii) Replacement all rusted nut bolts.
Make-CROMPTON 800 Amps
Make-Areva 800 Amps (VCB Trolley Mounted)
Make-ABB 630 Amps
Make-CROMPTON 800 Amps
Make-Areva 800 Amps
Make-ABB 630 Amps
Supply only the following spare for Crompton make of 800 Amps VCB:-
Master trip relay VAJH13
Trip supervision Relay VAX31
Hooter 110 VAC
Digital Ammeter square type of size 96 mm X 96 mm
Digital Voltmeter square type of size 96 mm X 96 mm
Hooter 230 VAC
Local / Remote switch
TNC switch
TTB test terminal Block
Load Manager
AC/DC Fail unit
8 Window Annunciator as per existing size
Aux Relay VAA 33 of suitable size
CG Make VCB Trip Coil of 240 Volt
CG Make VCB Closed Coil of 240 Volt
Spring Charging motor of 240 Volt
Rack-in-rack-out half gear
Rack-in-rack-out handle
CG Make VCB Aux Switch
11 KV CG Make 800 Amp Vacuum bottle
CG Make VCB spring charging handle
Manual Push to trip switch
CG Make VCB finger contact
CG Make VCB poll housing
CG Make VCB Vacuum Interrupter
CT of required size
PT of required size
11 KV 3.15 Amps PT fuse
Spring charging mechanism
Supply only the following spare for AREVA make of 800 Amps VCB of 11 KV :-
11 kv Areva make HWX 230 Volt Spring Charging motor
Tripping coil 30 VAC
Closing coil 30 VDC
Finger contact of 400 Amps
Pool housing
A/B key lock as per existing
Aux switch as per existing
Vacuum bottle of 11 KV
TNC Switch
LR switch
6 window annunciator
Master trip relay VAJH13
Load manager
O/C + E/F Relay as per existing Model No and Make
110 VAC power pack
VAA 33 Aux Relay
CT of required size
PT of required size
Ammeter Digital
Voltmeter Digital
Spring charging mechanism
Spring Charging handle
Rack-in-Rack-out handle
Supply only the following spare for ABB make of 630 Amps RMU + VCB:-
Multi function meter
Digital Voltmeter
RMU ABB safe plus operating handle
11 KV 3.15 Amps PT fuse
ABB Make RMU Tripping Coil
ABB Make RMU Closing coil
Spring Charging motor
O/C + E/F Relay micron P 111
ABB RMU protection relay
CT of required size
PT of required size
S& F 11 KV, SF 6,RMU Panel SF 6 Gas filling up to the indication mark complete all as specified and as directed
Material and labour for Servicing/Repairing of Transformer by disconnecting of LT and HT side cable carefully from Transformer and draining out transformer oil, dismantling transformer top cover and dismantling of 4 Nos LT bushing and 3 Nos of HT bushing including necessary tools and plant for removal of sediments, carbon deposits at bottom of transformer tank, on core, on winding etc cleaning with new transformer oil including cleaning of oil tank and attending leakage problem with oil seal and all gaskets and re assembling complete all as specified and as directed by Engr-in-charge. Note :- New Transformer oil and spare parts shall be measured and paid separately under the relevant item of schedule as supply only excluding oil seal
Transformer 11 KV/433V of capacity 100 KVA to 400 KVA
Transformer 11 KV/433V of capacity 500 KVA to 1000 KVA
Labour for attaining the fault of any type of step down transformer breakdown or HT 11 KV / 22 KV / 0.415 KV cable failure round the clock on call basis when required and directed including detect the cable fault and necessary excavation of soil and refilling the soil, joint the faulty cable with new straight through joint kit, after jointing, testing, commissioning and charging of HT Line complete all as specified and as directed by Engr-in-charge. Note:- (i) Transformer spares and Cable joint required size measured and paid separately under relevant item (ii) The quoted rate shall be deemed to include the special tool charges required for transformer fault testing and cable fault detector machine visit charges (iii) The quoted rate must be included the cable hypot test and demoisturing charges.
M & L for on line Centrifuging (filtration) of transformer oil incl checking initial and after filtration dielectric strength of oil for transformers installed at various locations in MH and Range Hills area under AGE E/M(West) with suitable machine having filtration, heating and pumping facility to improve the dielectric strength/insulation value of oil all as specified and directed by Engr - in- Charge. Note:- (i) Dielectric strength of oil after filtration/dehydration shall not be less than 60 KV. (ii) Oil for toping up shall be measured and paid for separately as supply only. (iii) The contractor will take shut down orders in writing before commencement of the work from Engr - in - Charge. (iv) The contractor shall ensure no wastage of transformer oil. (v) The contractor solely responsible for any damage to the transformer during filtration operations. He is responsible for making good any damage to the transformer at his own cost without any extra cost to the department. (vi) The contractor shall ensure that the conservator tanks are full to its level before starting the dehydration. (vii) The di-electric strength of oil shall be tested before & after filtration. Test results shall be submitted to Engr-in-Charge.
Supply the material in repair or replacement of taking out core assembly of defective winding materials from HV side of the transformer and replacement with super enamelled electrolytic insulated copper wire of suitable gauge to withstand the high voltage including replacement of new cork sheet, neoprene gasket etc and reinstalling the core assembly after re- winding all as directed.
Supply the material in repair or replacement of taking out core assembly of defective winding materials from LV side of the transformer and replacement with super enamelled electrolytic insulated copper wire of suitable gauge to withstand the high voltage including replacement of new cork sheet, neoprene gasket etc and reinstalling the core assembly after re- winding all as directed.
Supply the material in repair or replacement of HT metal parts brass or copper & HT bushing Voltage Grading 11 KV suitable for indoor/outdoor type transformer of capacity 100 KVA to 1000 KVA as required at site all as directed
Supply the material in repair or replacement of LT metal parts (Brass / Copper) & LT bushing grading 50 volts suitable for out door of capacity as required at site all directed for the following capacity of transformer
100 KVA to 400 KVA
500 KVA to 1000 KVA
Supply only Breather / Silica gel
Supply only Oil temperature indicator as per existing size and capacity
Supply only Winding temperature indicator as per existing size and capacity
Supply only 4" Dia thermometer
Supply only Labour for Cleaning, checking and rewiring of the marshalling box
Supply only Oil level glass indicator
Supply only LED indication lamp of any colour 19 /22 mm dia
Supply, laying & testing XLPE insulated screened PVC bedded Aluminium HT Cables, Stranded Compacted Circular Aluminium Conductor, Screen with Extruded Semi Conducting Compound in Combination with Copper Tape, Cores Laid Up, Inner sheath of PVC, Galvanised Steel round Strip Armoured, & Overall PVC Sheathed Cable Conforming to IS 7098 (Part-2) 2011 and laid in trenches / passing through pipe etc complete all as specified and as directed of following sizes.
95 Sq mm to 185 Sq mm X 3 Core 11000 Volts
240 sq mm to 300 sq mm X 3 Core 11000 Volts
Supply only Cable jointing kit for below mentioned voltage (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following sizes
95 Sq mm to 185 Sqmm 11000 Volts
240 sq mm to 300 Sqmm 11000 Volts
Supply only Cable jointing kit for below mentioned voltage (Earthed) grade cable for outdoor termination heat shrink type End joint complete with Jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following sizes
95 Sq mm to 185 Sqmm 11000 Volts
240 sq mm to 300 Sqmm 11000 Volts
Supply only Cable jointing kit for below mentioned voltage (Earthed) grade cable for indoor termination heat shrink type End joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following sizes
95 Sq mm to 185 Sqmm 11000 Volts
240 sq mm to 300 sqmm 11000 Volts
Supply only Cable jointing kit for below mentioned voltage (Earthed) grade cable for Boot Joint termination heat shrink type End joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following sizes
95 Sq mm to 185 Sqmm 11000 Volts
240 Sq mm to 400 Sqmm 11000 Volts
Supply and fix air break gang operated HT 11 KV volt grade out door type, triple pole of capacity 200 Amps rating mounted on polymer based 9 insulator and fitted on steel frame horizotally mechanically operated mechanism from ground level consisting of operating rod of 25 mm bore heavy grade GI pipe of suitable length worked from ground level and with locking arrangement including pad locks with key flat iron clamp 50 mm X 6 mm including taking down old unserviceable Gange operated switch complete as specified and directed. Make: Pactil/ Atlas /Jaipuria Brothers / MEC Trivandrum) Note : The unit quoted rate shall be deemed to be included for removal of cable and cable termination charges to new Gang Operated switch (if any)
Supplying, installing, fixing, connecting and testing of polymer based Drop-out fuse set (set of 3 nos), mounted on insulators with steel frame 200 Amps capacity, suitable for 11 KV, HT system, out door type, including Expulsion fuse carriers and fuse element Upto 20 Amp, including taking down old unserviceable one complete all as specified and as directed by Engr-in-charge.
M&L for Lightning arrester high tension expulsion type complete with all fittings transmission class, discharge capacity 30 Kilo amps suitable for 11000 Volts supply including taking down old lightning arresters complete all as specified and as directed by Engr-in-charge.
M&L for PCC cable cover class LV, type-I, flat size 450x300x40 mm factory casted ISI marked complete all as specified and as directed by Engr-in-charge.
Material and labour for Cement concrete in foundations, filling and mass concrete of PCC M-15 grade (Nominal Mix) using 40 mm graded stone aggregated complete all as specified and directed
Supplying and laying synthetic Rubber insulated blue colour mats 3 mm thick for voltage upto 33 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x1m
Supply and fix in repair / maintenance Space Heater for Panel HT LT Panel Electrical Panel, Switch Gear Panel Boards/Electronic Instruments Panel Space Heater 80 to 120 watt capacity, rust resistance and shock proof along with necessary connection all as directed as specified and directed Make : Airflex, Warmex, as per sample
M & L Painting of Two /four pole structure complete by two coat of aluminium paint directed by Engg in charge
Supply & spreading stone aggregates of size 40 mm in complete area of outdoor substation & 4 pole structure area all as specified.
Supply only Male contact/ Moving contact blade for 11/22 KV complete.
Supply only Female contact/ Fix contact Jaw for 11/22 KV complete.
Supply Only Tinned Copper flexible jumper 200 A, 11/22 KV complete.
Supply only MS jumper carrier for 11/22 KV complete.
Supply only Back connector plate for 11/22 KV complete.
Material and Labour for shifting of transformer of any capacity from one area to another area and placing in position and making all connections including removing and depositing the old transformer to store yard carefully and properly testing and commissioning transformer complete all as specified and as directed by Engr-in-charge. .
Supply and fix, Power pack 30 V suitable for HT VCB of capacity 630A/800A,11KV, 3 ph,50 Hz Panel complete all as specified and as directed by Engr-in-charge. Make-CROMPTON/ AREVA
M&L for cleaning of MES electric supply installations/campus by surface dressing or trimming of natural ground to remove small inequalities (including removing vegetation/ shrubs/brush wood/under growth) and carrying away the rubbish to a distance of not exceeding 50 meters away complete for the various sub station all as specified and as directed.
Sunhari Electricals (BID ID -3288330)
SKS Electricals (BID ID -3288249)
SBS Enterprises (BID ID -3284687)
Rama Electricals (BID ID -3284805)
Priyanka Power line (BID ID -3284792)
Mahindra Electric Stores (BID ID -3283961)
Bidder Name
Rama Electricals
SBS Enterprises
Priyanka Power line
Mahindra Electric Stores
SKS Electricals
Nexus Infratech
Sunhari Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .