Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 CrAdmitted-Finance | ₹3.5 Cr | L1 | Admitted-Finance |
| 2 | L2₹3.5 Cr+₹81,624.50 (0.24%)Admitted-Finance C 9 53 IIND FLOOR SECTOR 08 ROHINI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | ₹3.5 Cr+₹81,624.50 (0.24%) | L2 | Admitted-Finance |
| 3 | L3₹3.5 Cr+₹5.2 L (1.50%)Admitted-Finance 15 HOSHIYAR SINGH PARK KIRBY PLACE DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | ₹3.5 Cr+₹5.2 L (1.50%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Shivom Projects Private limited L3 | L G BUILDERS L2 | n s kumar and sons L1 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down chowkats or frames not exc. 1.5 sq. m with shutters (without taking off shutters from the frames) , complete all as specified and directed. | 136 | Each | 20 ₹2,720 Lowest | 40 ₹5,440 | 50 ₹6,800 |
| 2.00 | Taking down chowkats or frames exc. 1.5 sq. m but not exc 4 sqm each with shutters (without taking off shutters from the frames) , complete all as specified and directed. | 204 | Each | 50 ₹10,200 | 40 ₹8,160 Lowest | 60 ₹12,240 |
| 3.00 | Taking down shutters of any description exc 1 sq. m and not exc 2 sqm each, complete all as specified and directed. | 272 | Each leaf | 25 ₹6,800 | 40 ₹10,880 | 15 ₹4,080 Lowest |
| 4.00 | Taking down old window / ventilators with frame, any description, including guard bars not exc 1.5 sqm each , complete all as specified and directed. | 348 | Each | 25 ₹8,700 Lowest | 40 ₹13,920 | 60 ₹20,880 |
| 5.00 | S&F powder coated anodised aluminium frame for windows, ventilators, grill with one or more rebates including necessary joining cleat, powder coated aluminium snap beading, screws for fixing etc. complete all as spd & directed.
Note: (1) Only aluminium frame items to be measured.
(2) Glass, wiremesh, handles to be measured & paid separately.
(3) Minimum thickness of powder coating to be 50 micron. | 1,302.3 | Kg | 350 ₹4,55,805 Lowest | 395 ₹5,14,408.5 | 440 ₹5,73,012 |
| 6.00 | S & F powder coated anodised aluminium ventilator/sliding window comprising of sliding runner of two way aluminium frame section (weight not less than 0.80 Kg/RM) as per series-A, consisting of two/three sliding shutters made out of section (weight not less than 0.55 Kg/RM) with 4mm thick glass/wiremesh fixed with rubber and aluminium beading including down push type locking arrangement in shutter, fixed the frame with rawl plug shutter complete all as specified. | 306 | Sqm | 3,800 ₹11,62,800 Lowest | 4,500 ₹13,77,000 | 4,500 ₹13,77,000 |
| 7.00 | S & F for mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors, angle iron chowkhats; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed. . | 2,520 | KG | 85 ₹2,14,200 | 72 ₹1,81,440 Lowest | 79 ₹1,99,080 |
| 8.00 | S & F for Bands, straps, supports or stays for rainwater , Ventilating pipes, including bolts , if required; hooks ( stay), heavy, for large gates; hook and pintol hanges; large hasps and staples ; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters ; knee piece inserts; two way and three ways straps , plate washers and similar small articles conforming to Fe-290 Gde E-165, complete all as specified and directed. | 306 | KG | 90 ₹27,540 | 80 ₹24,480 Lowest | 90 ₹27,540 |
| 9.00 | M & L for 1mm thick Mild steel, plain, black sheet in hearths ; covering to door shutters; covering to door chowkhats ( frames); chullah hoods ; water tanks; water troughs; ducts;urinal troughs and funnels, etc. cut to size , edges beaded if directed, holes punched; including round headed screws , clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/ riveted seams, including bending, turning up, mitred angles, stopped ends, outlets , etc. as required, complete all as specified and directed.. | 122 | Sqm | 800 ₹97,600 Lowest | 1,150 ₹1,40,300 | 880 ₹1,07,360 |
| 10.00 | S&F factory made 35 mm thick 2nd class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, cla-use 8.24 (a); supplied and fitted to chowkats incl one shop coat of pink primer as speicifed and directed. | 258 | Sqm | 1,800 ₹4,64,400 | 1,550 ₹3,99,900 | 1,400 ₹3,61,200 Lowest |
Tender Value
Refer Docs
EMD Value
₹3.4 L
Closing Date
22 Feb 2021, 6:00 pmClosed
CHIEF ENGINEER DELHI ZONE
HQ CHIEF ENGINEER DELHI ZONE
SPECIAL REPAIR TO BLDG NO P-07, P-09, P-18, P-19 AND P-22 AT BASANTAR LINE UNDER GE (WEST) DELHI CANTT-10
2020_MES_390015_1
CEDZ-27 OF 2020-2021
Open Tender
Civil Works
Item Rate
270 days
DELHI CANTT
MES contractor enlisted in MES under class B cat a i having deposited Standing Security of Rs 4.00 lakh with department. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
10 documents required · 10 mandatory
₹2,000
GE WEST DELHI CANTT
₹3.4 L
Yes
1 Mar 2021
28 Oct 2020
24 Feb 2021
28 Oct 2020
22 Feb 2021
8 Feb 2021
Amount
Taking down chowkats or frames not exc. 1.5 sq. m with shutters (without taking off shutters from the frames) , complete all as specified and directed.
Taking down chowkats or frames exc. 1.5 sq. m but not exc 4 sqm each with shutters (without taking off shutters from the frames) , complete all as specified and directed.
Taking down shutters of any description exc 1 sq. m and not exc 2 sqm each, complete all as specified and directed.
Taking down old window / ventilators with frame, any description, including guard bars not exc 1.5 sqm each , complete all as specified and directed.
S&F powder coated anodised aluminium frame for windows, ventilators, grill with one or more rebates including necessary joining cleat, powder coated aluminium snap beading, screws for fixing etc. complete all as spd & directed. Note: (1) Only aluminium frame items to be measured. (2) Glass, wiremesh, handles to be measured & paid separately. (3) Minimum thickness of powder coating to be 50 micron.
S & F powder coated anodised aluminium ventilator/sliding window comprising of sliding runner of two way aluminium frame section (weight not less than 0.80 Kg/RM) as per series-A, consisting of two/three sliding shutters made out of section (weight not less than 0.55 Kg/RM) with 4mm thick glass/wiremesh fixed with rubber and aluminium beading including down push type locking arrangement in shutter, fixed the frame with rawl plug shutter complete all as specified.
S & F for mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors, angle iron chowkhats; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed. .
S & F for Bands, straps, supports or stays for rainwater , Ventilating pipes, including bolts , if required; hooks ( stay), heavy, for large gates; hook and pintol hanges; large hasps and staples ; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters ; knee piece inserts; two way and three ways straps , plate washers and similar small articles conforming to Fe-290 Gde E-165, complete all as specified and directed.
M & L for 1mm thick Mild steel, plain, black sheet in hearths ; covering to door shutters; covering to door chowkhats ( frames); chullah hoods ; water tanks; water troughs; ducts;urinal troughs and funnels, etc. cut to size , edges beaded if directed, holes punched; including round headed screws , clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/ riveted seams, including bending, turning up, mitred angles, stopped ends, outlets , etc. as required, complete all as specified and directed..
S&F factory made 35 mm thick 2nd class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, cla-use 8.24 (a); supplied and fitted to chowkats incl one shop coat of pink primer as speicifed and directed.
S & F factory made 35 mm thick 2nd class hardwood Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated incl one shop coat of pink primer complete all as specified and directed.
S&F factory made 25mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides as shutter of cupboard complete all as spd & directed.
S&F Aluminium anodised 100mm hasp and staple including bolt to hinges plate and fixed with screws all as spd & directed.
S&F Solid PVC door frame of size 50mm x 95mm made out of 5mm wood grain printed PVC sheet reinforced with M.S square tube, complete all as specified and directed.
S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30 mm thick (stiles),with 2, 4, or 6 raised panel design with 2mm thick 3D wood grain Moulded PVC Sheet Polyurethane painted on the front face & 2mm Plain colour PVC Sheet on back face complete all as specified and directed.
S & F stainless steel butt hinges 100mm long medium weight etc complete all as specified and directed.
S & F stainless steel butt hinges 75mm long medium weight etc complete all as specified and directed.
S&F PVC butt hinges 100mm size and fixed to chowkhat complete all as spd & directed.
S&F PVC barrel tower bolt 200mm size.
S&F PVC handle D-type of 125mm size.
S & F 300mm long aluminum, anodized barrel sliding bolts of extruded section complete all as specified & directed.
S & F 200mm long aluminum, anodized barrel tower bolts of extruded section complete all as specified & directed.
S & F aluminum anodised handle 150 mm long cast type complete all as specified & directed.
S & F floor door stoper 150mm (Overall length of cover plate) of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor
S & F Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed complete all as specified and directed.
S & F 20mm dia 600mm long chromium plated towel rail with brackets, fixed to wall with plugs and steel screws complete all as specified & directed.
S&F in repair stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples (for steel windows and gauzed doors) all as specified and directed
Hacking out old broken glass any thickness, size quality or description from wooden/steel frame fixed with wooden beads/metal pinning and S&F 3 mm thick sheet glass in square not exc. 0.50 sqm in each pane, fixed with pin headed beads or putty (in metal frames etc) complete complete all as specified and directed.
S&F 3 mm thick pin headed or figured glass and glazing with oil putty in square n exc 0.5 sq. m in each pane including hacking out old broken glass any description, complete all as specified and directed.
S&F for Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, fixing of nuts and bolts as necessary, gusset plates, riveting, etc., conforming to Fe -290 Gde E-165 complete all as specified and directed.
S&F for Pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/chajjas covering, cladding to wall fixed with self tapping screws incl cutting of chase in wall and inserting 50 mm deep, and making good and matching the surface with existing finish, complete all as specified and directed.
M&L for preparation of new steel surfaces over 10 cm width or girth, not otherwise described and applying two coat of synthetic enamel painting over a coat of red oxide primer etc all as specified and directed.
S&F in repair110 mm bore PVC (SWR) pipes single socket in any length with rubber ring/ cement solvent cement jointsfixed to walls including PVC clamp including taking down old unsv pipes complete all as specified and directed.
S&F PVC bend/tee suitable for 110mm bore pipe complete all as directed
S&F Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths confirming to Fe 410W (Gde E250) all as specified and directed
M&L rendering 15 mm thick in cement mortar 1:4 on fair faces of brick or concrete surfaces finished fair and even with using extra cement incl water proofing compound @ 3% by weight of cement and taking down old cement plaster of any description, complete all as specified and directed. Note:- (i) The rendering is to be done in cement and sieved badarpur sand only (1:4).(Supplying integral WPC is included in this unit rate.) (ii) Cost for necessary steel formwork & shuttering of the above aspects shall be deemed to be included in the quoted rate of the respective item and nothing extra shall be paid on any account.
M&L for rendering 15 mm thick in cement mortar 1:6 on fair face of brick work/ concrete surfaces and finished even and smooth without using extra cement incl taking down old plaster, complete all as specified and directed.
M&L for complete removal of existing treatment on walls to the entire satisfaction of Engr-in-Charge including preparation of surfaces and applying two coat of cement base paint complete all as specified and directed.
M&L for preparing newly plastered surfaces on walls and applying two coat of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls applying birla white putty 2mm on wall even and smooth surface and applying two coat of oil bound distemper over a coat of alkali resistance primer (of approved quality and tint) on wall using painting roller, complete all as specified and directed.
M&L for complete removal of existing treatment by brooming down or steel wire brushing, scrapping down smoke, mass, efflorescent salt and oil and greesy spot etc. washing rubbing down distemper surfaces and applying birla white putty 2mm on wall even and smooth surface and applying two coat of oil bound distemper over a coat of primer (of approved quality and tint) on wall using painting roller, complete all as specified and directed.
M&L for preparation of old decorated surfaces and applying two coats of white wash on ceiling complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying two coats of white wash on wall complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying three coats of white wash on ceiling complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying three coats of white wash on wall complete all as specified and directed.
M&L for green marble 18mm thick (table rubbed and polished) in cooking platfarm/ floor, machine cut laid over 20mm thick screed bed or bedding layer in CM 1:6 and jointed and pointed with grey cement mixed with colour pigment to match the shade of the slab including rubbing and polishing and making edges chamfered and demolition of old stone slab of any description , complete all as specified and directed.
Material and labour Kota stone slab flooring 20-25 mm thick laid over & including 20mm thick cement screed bed 1:6, and jointed with grey cement slurry mixed with pigment to match the shed of the slab including rubbing and polishing incl rounding to nosing on front side of treads complete all as specified and directed.
All as per Ser No. 47 here-in-before but 15-20mm thick in risers, skirting, dado over and including 10mm thick cement screed in CM 1:4.
Demolition of cement concrete In ground floor and paving n.exc 15CM thickness (below or above ground level) complete all as specified and directed.
M&L for Plinth protection 75 mm thick in PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) laid in alternate bays(not exc 2 Sqm each) finished even and fair at top using extra cement and providing joints throughout the thickness of plinth protection, filled with mastic filling comprising one part of bitumen 85/25 graded and three parts of sand by weight all as directed.
S&F in repair 100mm dia cast iron (sand cast) soil, waste and vent pipes in any length, with or without ears, with cement joints, fixed to walls including dismantling of old unsv pipes, complete all as specified and directed.
S&F in repair 75mm cast iron (sand cast) soil, waste and vent pipe in any length with or without ears with cement joints fixed to walls, including dismantling of old unsv pipes complete all as specified and directed.
S&F in repairs 100mm bore spun cast iron bends/Tee (any radius) diminishing pieces or tapers (larger bore to be measured) with oval access doors complete all as spd and directed.
S&F CI Cowl for 100mm bore of CI spun pipe.
S & F 75mm dia CI floor trap with grating including jointing to waste pipe with lead joint, fixed complete all as specified & directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.50m depth, for foundation etc. and getting out in any type of soil.
Returning/ filling in excavated approved earth in to trenches around pipe etc after laying of pipes and testing complete including watering and well ramming in 25 cm layers.
Removing surplus soil to a distance exceeding 1.50KM and n.exc 5KM , depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and directed.
M & L for 100mm nominal size double wall corrugated HDPE pipes stiffnesss class SN 8 high density, polyethelene pipe resistent to chemicls, easy and light weighted, long living, low friction, flexible, sun resistant pipe and laid in trenches including demolition of old pipes, including connecting to existing manhole, complete all as specified and directed.
M & L for preparation of old painted wood or wood based surface of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint (approved tint) complete as specified and directed.
Material and labour for preparation of old steel surface of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint (approved tint) complete as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar incl all quoins, arches, pillars etc but excluding ashlars facings dressed stone work and Precast concrete articles,complete as specified and directed
M&L for Brick work with Sub class 'B' bricks straight or curved on plan exceeding 6m mean radius, built in Cement mortar 1:6 complete as specified and directed
M&L for Brick work with Sub class 'B' bricks straight or curved on plan to any radious in half brick thick walls, built in Cement mortar 1:4 complete all as specified and directed.
M&L for Providing precast cement concrete type B0 1:2:4 (12.5 mm graded agg) louvres and jallies, 25mm thick (mea-sured solid), including all mouldingsfixed to brick/concrete surfaces with cement mortor 1:4 complete all as specified and directed.
S&F in repair GI tubing 15mm bore medium grade galvanised with all fittings and fixed complete to wall and ceiling or laid in floors incl taking down old steel GI tubing complete all as specified and directed.
S&F in repair GI tubing 20mm bore medium grade galvanised with all fittings and fixed complete to wall and ceiling or laid in floors incl taking down old steel GI tubing complete all as specified and directed.
S&F in repair vitreous chinaware wash hand basin flat back of size 550mm x 400mm complete including provision of pair of mild steel angle iron brackets of suitable size duly painted, (including 32 mm dia chromium plated waste coupling, PVC waste pipe) and cutting for pinning in ends of brackets in wall etc complete all as specified and directed.
S&F in repair viterous china squatting pan (orissa pattern) long pan size 580x440mm white with integral footrest with 'P' or 'S' trap complete (excluding flushing cistern and flush pipe), complete all as specified and directed.
S&F in repair curtain rail (drapery rod ) 20 to 25 mm dia coloured with pair of suitable brackets, fennals and also making good the wall surface to match the existing surfaces complete all as specified and directed.
S&F in repair looking mirror fitted to wooden plug with CP brass screws, complete all as specified and directed. Make- Prayag
S&F in repair 15 mm bore angle valve, cast copper alloy screwed down high pressure with capstain head with long shank & cup complete all as specified and directed.
S&F in repair 15mm dia bib tap long body fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe, fancy type, cast copper alloy, chromium plated long body with flange complete all as specified and directed.
S&F in repair 15mm dia chromium plated pillar tap fancy type with fly nut capstan head screwed for 15mm dia pipe, complete all as specified and directed.
S&F in repairs 15 mm bore concealed stop cock, regular body with adjustable wall flange, complete all as specifed and directed.
S & F stainless steel sink without drainage board made of stainless steel of 1 mm thick for kitchen with plugs, washer of over all size 495mm x420mm and bowl size 410mm x 330mm x 160 mm, complete all as specified and directed.
Dismantling of PVC water storage tanks exc 500 ltrs & n.exc 1000 ltrs capacity and removing from site all as specified.
S&F rotational moulded polythylene water storage tanks 1000 Ltrs capacity, white coloured, triple layered (cylindrical vertical with closed top) hoisted including nipple, brass float valve suitable for water tank connection and fixed in position complete all as spd & directed.
S&F in repairs over head shower rose of size 150x150mm square, single flow (ABS Body chrome plated with grey face plate) with rubit cleaning system along with CP brass shower arm 190mm long flat shape for wall mouned shower with flange complete all as specified and directed.
S&F in repairs PVC low level white flushing cistern, valveless syphonic action type 10 ltr capacity with inlet, ball valve, float and handle including PVC flush pipe 32mm dia bend and a pair of mild steel iron brackets of suitable size including making necessary connection to water supply pip line and, complete all as specified and directed.
S & F PVC connection 15mm dia and 60 cm long with 2 Nos PTMT check nuts with washers complete all as specified and directed.
S & F in repair 32mm dia and 60 cm long PVC waste pipe complete all as specified and directed.
Dismantling of floor, hearth or walling including cement mortor bedding (but not backing removing serviceable to store and rubbish off the premises complete all as specified and directed.
M&L for Glazed ceramic colour tiles in vertical surface of size 350 x250x 7 mm or 450x 350x7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick cement plaster in CM 1:4 all as specified and directed.
M&L for Non Skid ceramic tiles 7 to 8 mm thick(square/ rectagular) area of each tile exceeding 0.11 sq m but not exceeding 0.18 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 20mm thick screed bed or bedding layer in CM 1:6, all as specified and directed.
All as per Ser No. 85 (here-in-before) but in skirting/ dado all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and paving not exc. 15cm thickness (below or above ground level), complete all as specified and directed.
M&L for 75 mm thick, PCC (1:4:8), type D-2 (using 40 mm graded stone aggregate), as in sub base under floor complete all as specified.
M&L for 50mm thick fine sand layer spread uniformly over sub base complete all as specified.
M&L for Machine pressed precast concrete interlocking tiles/paver block any colour, shape and size (as approved by GE) conforming to IS 15658 of 80mm thickness M-40 grade with grey cement and no pigment including filling the joints upto full depth with fine sand, complete all as specified and directed.
S&F in repair stainless steel utensil rack (plate rack) as per sample fixed in qtrs of Basantra line all as specified and directted.
M & L for providing and injecting chemical emulsion for post construction antitermite treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the substructure to a depth of 300 mm including excavating channel along the wall and rodding etc. complete.
M & L for treating of soil under existing floors using emulsion @ one litre per hole, 300 mm apart including drilling and plugging 12 mm dia. Holes with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors complete as specified and directed
Impregnating cream for injection into masonry or concrete wall 230mm thick against capilary rising humidity. Rising bar super srong (Product No. 201) of chowgale building chemicals or equivalent piilite/Drfixit/sika/fosroc complete all as specified and directed. Method of Application :-Methodology (a) The surface must be sound, absorbent, clean, free of dust, oil, paint, curing agents, loose cement or lime plaster & concrete, debris, or any separation layers. (b) The plaster must be knocked off at least 50cm beyond the visibly penetrated area. (c) Damaged mortar joints are to be scraped out to a depth of approximately 2-3cm. All sharp edges/joints needs to be levelled, loose concrete to be removed. (d) Drill boreholes at ground level horizontally. The boreholes are drilled horizontal into the masonry. (e) The holes should be drilled until a depth of approx 5cm (for a 6cm thick wall) before the end of the all is reached. The boreholes should have a diameter of 12mm upto a maximum of 15mm and should be spaced approx 100 to 120mm apart and the vertical offset is 6cm max. (f) Before inserting Rising Bar Super Strong or equivalent the boreholes must be cleaned from boring dust by using air pressure, it is not necesary to pre-wet the borehole. (g) For applying of Rising Bar Super Strong or equivalent the dosing system inserted as far as possible into the borehole. While dosing the product uniformly, the injection nozzle is pulled out leading to a completely filled borehole. (h) Treatment of highly absorbent masonry might require repeated filling of the borehole. Depending upon extent of damage, Rising Bar Super Strong or equivalent can be re-injected into the same hole after 24hrs. Depending on abosrbency, application or masony thickness 0.1 to 0.15 litre/m with 10cm wall thickness.
M & L for 18/19mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified & directed.
S&F 100mm size stainless steel handle, bow shaped as per sample for cupboards complete all as specified and directed.
S & F in repair 50mm drawer lock (as approved) gde-I complete all as specified and directed.
M&L PCC 1:5:10 Type E-2 (using 40 mm graded stone aggregate ) in mass concrete incl demolition of unreinforced lime concrete exc 15cm thickness for sunken portion of WC, complete all as specified and directed.
Water proofing treatment to sunken RCC Slabs (i) Apply a coat of cement sullry @ 0.488 Kg/sqm mixed with tapecrete @ 0.253 Kg/sqm after surface preparatin all as per manufacturer's insturctions. (Make of tapecrete : M/s CICO Engg Services) (ii) Apply hot bitumen 30/40 (Grade S-35) conforming to IS-73-1961 @ 0.70 kg/Sqm and providing transparent polythene film 200 micron (heavy duty) conforming to IS-2508-1977 laid with 150mm overlaps. (iii) Then apply 1.5mm thick layer of cement slurry @ 1.288 kg/Sqm mixed with tapecrete @ 0.570 kg/sqm and course sand @ 1.289 kg/sqm. Allow the treatment to air curing for 4 hours followed by water curing for 48 hours. The whole treatment shall be taken upto full depth of parapet wall and tuck into groove in parapet alround. (iv) Sunken floor shall be filled with graded cinder.
REPAIRING & REHABILITATION OF RCC STRUCTURES
Work for repair and rehabilitation shall be executed with close suppervision of qualified engineer, especially qualified in structural rehabilitation work and the following requirements shall be fulfilled by the contractor without any extra cost, the rates quoted for respective item shall be deemed to be inclusive of these aspects:-
(i) Propping and supporting the structural members and its adjoining areas with steel props (adjustable or as required) steel prop of up to 5 MT capacity and up to 3.2 m height, bracings, steel/timber runners etc to relieve the structural member of the required load coming over it as per the standard pattern & approved by GE.
(ii) Providing and fixing temporary engineered steel tubular standard double scaffolding system on the exterior side, maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc with suitable working platforms at required locations with essential safety features for the workmen etc complete as per directions and approval of GE.
(iii) Providing and fixing plywood covering panels as per the directions of Engineer-in-charge with necessary backing framework to shield windows etc. from falling debris and removing and taking away the material after completion of work including making good any incidental damage(s) to the existing building or its finishes etc complete.
(iv) Providing, erecting, maintaining and removing temporary protective screens made out of Woven PVC cloth with all necessary fixing arrangement to ensure that it remains in position for the work duration as required by Engineer in charge.
(iv) Providing, erecting, maintaining and removing temporary protective screens made out of Woven PVC cloth with all necessary fixing arrangement to ensure that it remains in position for the work duration as required by Engineer in charge.
Chipping of unsound/weak concrete material from slabs, beams, columns etc. with standard power driven percussion type or pneumatic chisel of standard make including tapering all edges, making square shoulders of cavities etc of average depth of 25mm complete and disposal of debris up for all lifts and leads complete all specified and directed.
Chipping of unsound/weak concrete material from slabs, beams, columns etc. with standard power driven percussion type or pneumatic chisel of standard make including tapering all edges, making square shoulders of cavities etc of average depth of 50mm complete and disposal of debris up for all lifts and leads complete all specified and directed.
Cleaning of reinforcement from rust including from behind the reinforcing bars to give it a totally rust free finished steel surface by hammering the rebar, using wirebrushes, chiseling and using applying rust remover cum passivator Sika rustoff 100 or equirment of Fosroc / BASF @ 0.20kg/Sqm/per coat with brush or as per manufacturer's specifications to remove rust from existing reinforcement and removing loose particles after 24 hrs of its application with wire brush and thoroughly washing with water and allowing it to dry; applying a epoxy based zinc rich rebar corrosion protection system @ 0.15Kg/Sqm/coat or as per manufacturer's instruction complete all as specified and directed.
Supply, mixing and applying bonding coat, including cost of material, on prepared non-metallic surface of parent material as per specifications and direction of Engineer-in-Charge complete. SBR polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area with its proportion as specified and directed.
Providing, mixing and applying SBR polymer (of approved make) modified cement mortar in proportion of 1:4 (using coarse sand) with polymenr min 2% by weight of cement in layers, each layer not exceeding 15mm thick, of average thickness 25mm (in two layers) including trowelling with wooden tools etc. complete as per specifications and directions of Engineer-in-charge (75mm size cube crushing strength at the end of 28-day to be not less than 25N/sqmm)
Providing, mixing and applying SBR polymer (of approved make) modified cement mortar in proportion of 1:4 (using coarse sand) with polymenr min 2% by weight of cement in layers, each layer not exceeding 15mm thick, of average thickness 50mm (in three layers) including trowelling with wooden tools etc. complete as per specifications and directions of Engineer-in-charge (75mm size cube crushing strength at the end of 28-day to be not less than 25N/sqmm)
M & L for providing rebar of required length & upto &including 12 mm dia with Sika Anchor Fix ® -3/Mungo/Fischer FISV 390/Hilti RE-500 epoxy resin whereever required in RCC members including power drilling for holes (of size 16mmx160mm ), cleaning of holes, filled with epoxy to ensure the bond as per manufacturers instructions, complete all as specified and directed.
M & L for providing rebar of required length & 12-20 mm dia with Sika Anchor Fix ® -3/Mungo/Fischer FISV 390/Hilti RE-500 epoxy resin whereever required in RCC members including power drilling for holes (of size 20mmx200mm ), cleaning of holes, filled with epoxy to ensure the bond as per manufacturers instructions, complete all as specified and directed.
M&L for use & waste of special water tight form work using steel/aluminium sheets, centering and shuttering with steel tubular members including strutting, propping, bracing bolting etc so as to withstand a pressure of 0.1 Mpa including removal of forms for all locations including beams, columns, slabs, walls, foundations, footings, landings, stairs, balconies etc. complete all as specified and directed. Note : Form work shall be 100% leak proof , for pupose of payment area in touch with concrete shall be measured.
Providing and placing in position ready to use non shrink, cementitious free flow micro-concrete, which shall be cement based prepacked single component, chloride free, non-shrink, free flow, self compacting, ready to use after mixing water in specified proportion obtained from approved manufacturer having compressive strength not less than 30N/mm2 (28 days) according to ASTM C 1107-99, complete all as specified and directed.
Providing and laying SBR polymer modified (of approved make @min 2% by weight of cement) plain/reinforced concrete jacket for the structural members e.g. columns, pillars, piers, beams etc with concrete having the specified minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria]with specifiedaverage thickness all-round existing core of RCC member. Rates shall be for finished surface area of concrete and shall include the cost of making holes in existing RCC slab, if required, for pouring concrete in shuttering mould of jacket and appropriate approved super-plasticiser for rendering concrete as flowable, self compacting but shall exclude cost of reinforcement, bond coat, shear keys, centering and shuttering, strutting, propping etc (Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument) 100 mm thick in Grade M 25 with cement content not less than 350 Kg per Cu M
Providing and inserting 10 mm dia. 200 mm long mild steel shear key bars of required length and diameter in reinforced/plain concrete as per drawing and directions of Engineer-in-charge including power drilling holes of appropriate diameters to a minimum depth of equal to 12 times the diameter of shear key bar/levelling gauge, cleaning the drilled holes of loose dust by blowing, insertion of epoxy from cartridge, placing the shear key bar in position and allowing it to stay undisturbed for 24 hours. (Rate shall include cost of labour, all materials, T&P for power drilling in concrete, epoxy cartridges, plastic nozzle etc complete including cleaning the drilled holes of loose dust by blowing air.
Providing and inserting 12mm dia Aluminium/ galvanized iron injection nipples along crack lines or honey-comb area, including: i) drilling holes of required diameter up to depths from 40mm to 80mm or half the thickness of member (whichever is less), at required spacing of 300 mm ii) Making grooves of size 12mm x 12mm along the crack line. iv) Sealing the distance between the injection nipples with approved putty(Polymer modified cement mortar /polyester putty/epoxy putty) etc and allow it to cure. v) If cementitious grout material proposed to be used, washing and saturating the cracked surface with water by pumping from top most nipple and downwards complete as per the direction of Engineer-in-charge. (The rate shall include all material, labour and all operations above. The cost of grout material shall be paid separately on the basis of actual quantity consumed)
Supply & injecting shrinkage free low viscous epoxy resin based injection grout. Product: SikaduR-52 as per manufacturers instructions and as directed
Supply & injecting stirrer mixed SBR Polymer modified cement slurry made with shrinkage compensating cement in masonry work as per manufacturers instructions and as directed.
Dismantling of brick tiles or terracing tiles single layer on roof complete all as spd & directed.
Demolition of mud phuska on roof slabs, any thickness incl cleaning of roof surfaces and removing the debris upto the distance exc. 1.00Km but n. exc. 1.5Km complete all as spd & directed.
Demolition of reinforced cement concrete as in roof slabs, floor slabs, beams, staircases, landing, chajjas and similar suspended work , above ground level (reinforced cut to facilitate demolition) using chisel and hammer or Mechanically using power driver/pneumatic percussion chisels/hammers carefully without damaging remaining structure complete all as specified and directed.
M & L for reinforced cement concrete design mix M-25 (using 20mm graded stone aggregate) as in foundations, inlcuding rafts, footings, foundation beams etc complete all as specified and directed.
M&L for reinforced cement concrete design mix M-25 (using 20mm graded stone aggregate) as in columns and the like complete all as specified and directed.
M&L for reinforced cement concrete design mix M-25 (using 20mm graded stone aggregate) as in staircase and the like complete all as specified and directed.
M&L for ready mix concrete (RMC) of design mix M-25 (using 20mm graded stone aggregate) as in slabs supported on walls and beams, roof slabs landings, balconies canopies, deck slabs and the like including connected beams complete all as specified and directed.
S&F TMT bars 10mm dia and over, cut to lenght, bent to shape required, including cranking, bending spirally for hooping for coloums, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips as specified and directed.
S&F TMT bars 6mm to 8mm dia and over, cut to lenght, bent to shape required, including cranking, bending spirally for hooping for coloums, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips as specified and directed.
All as per Srl item No. here-in-before above but TMT bars 6mm and over upto and including 8mm as in stirrups, spacers and binders.
M&L form work to soffits of suspended slab such as roof slabs, balconies, floor slabs, cover slab, shelves, landings and similar work including beams, not exc. 200mm thickness finished rough (horizontal or sloping) as specified and directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions and the like complete all as specifed and directed.
Formwork to staircases with sloping or stepped soffits including risers and stringers (excluding landing), complete all as specified and directed.
M&L form work to sides & soffits of floor or roof beams, haunchings, griders bressummers lintels, cantilevers shelves including sup-ports, overhangs, etc also splays between floors and beams etc, complete all as specified and directed.
M&L formwork to edges of concrete flats, treads, breaks in floors, windows cills, concrete railings, opening in concrete walls, floor and roofs n.exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n.exc 20cm wide rough finished surfaces complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) on roof padding with water proofing compound surface finished even and smooth without using extra cement complete all as spd & directed. (Rate of WPC shall be included in unit rate)
M&L for water proofing treatment in following stages:- 1. Rendering in CM 1:3 with waterproofing liquid as per manufacturer's instruction over concrete surface finished even and smooth without using extra cement. 2. First coat of bitumen primer confirming to IS-3384@ 0.40 Kg/Sqm over plastered surface.(Bitumen primer shall be TANK MASTIC of M/S STP Ltd or ‘EMW FLATE’ of M/S Texas India Ltd). 3. Second coat of binding material using blown type bitumen confirming to IS-702 Gde 85/25 @ 1.2 Kg/Sqm applied over bitumen primer. 4. Third layer of APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.0 Kg/Sqm with a centre core of 90 micron high density polyethylene film protected on both sides with a high quality polymeric asphaltic mix, the polymeric asphaltic mix will be protected on both sides with thermo fusable HMHDPE film of make super thermolay manufactured by STP Ltd or ‘Hyper Plas’ (Polyster) manufactured by M/S IWL Ltd or ‘Shaliplas’ (polyester) manufactured by M/S Capital Steels and chemicals Pvt Ltd as approved by GE, black finish reinforced with non-woven polyester matt, with a thermo fusable finish.torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at the sides and 100mm at the ends complete all as specified and as directed.
M & L for PCC tiles of size 250mm x 250mm x 22mm thick with grey cement and no pigment, set and jointed in neat cement slurry over and including 15mm thick dcreed bed in cement mortar 1:4 complete all as specified and directed.
Description of Work / Item(s)
Amount
Taking down carefully copper/aluminium any type of point wiring (light/fan/socket /power) (fittings such as switches, ceiling roses, holders, sockets, light fittings) and deposit the same to MES Store and making good the disturbed surfaces of wall/floors/ceiling etc) complete all as specified and directed by Engineer-in-Charge
M&L concealed point wiring with PVC FRLS insulated multi stranded unsheathed cable 1.5 sqmm size with stranded copper conductor, 1100 volts grade conforming to IS-: 694 drawn in and including concealed PVC rigid conduit 20 mm dia including cutting of chases for laying conduit making good the surfaces as per existing surfaces or as directed with concealed sunk in pressed steel terminal boxes of 1.6mm thick factory made and painted with stove enameled black paint covered with 3mm thick plastic laminated sheet of required colour fixed with brass screws and cup washers including single core stranded copper conductor 1.5 sqmm PVC insulated unsheathed cable as earth wire to common earth and connected to earth dolly drawn in same concealed conduit complete all as specified and directed by Engineer-in-Charge for the following :-
(a) One light/fan/bell point controlled by one way switch 5 amps.
(b) One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
(c) One 3 pin 5 Amps socket outlet point controlled by one way switch on same board.
(d) One light controlled by two way switch 5 amps.
All as per item No. 2 (a) above but with 2x4 Sqmm and 1x 4 sqmm cable for earth connection for one 3 pin socket outlet 15 amps independent board complete all as specified and directed.
S&Fof switch piano type 5 amps single pole one way complete all as specified and directed.
S&F switch piano type 15 amps single pole one way complete all as specified and directed.
S&F of socket outlet multipurpose 2/3 pin 5 amps flush button type complete all as specified and directed.
S&F socket outlet multipurpose 2 in 1, 5 and 15 Amps complete all as specified and directed.
S&F of two way switch complete all as specified and directed.
S&F bell push flush type 5 Amps complete all as specified and directed.
S&F of ceiling fan regulator step type for 1200/1400 mm sweep ceiling fan including connections complete all as specified and directed.
S&F of electric bell Ding-Dong AC 230 Volt SP with brass screws and cup washers complete all as specified and directed.
S & F of LED bulb of 7 watt complete all as specified and directed.
S&F of bulk head LED light fitting 10 Watt deep drawn anodised aluminium body, epoxy white powder coated, heat resistant prismatic glass cover with gasket complete all as specified and directed.
M&L for decorative wall light fixture made up of polycarbonate, spiral B-22 Base Suitable for 7 watt LED Bulb complete Watts, Havells CITY 3.
S & F for Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings with connections complete all as specified and directed.
Supply, laying sub main wiring and drawing in and including 20 mm dia concealed PVC rigid conduits including cutting of chases for laying conduit making good the surfaces as per existing surfaces or as directed on walls 02 runs of IC x 6.00 sqmm (Main Cable and neutral) and one run of IC x 6.0 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforming to IS : 694 of 1990 including connection including taking down old wiring complete all as specified and directed.
M&L for Taking down ceiling fan, ceiling cable removing fan blades and deposited to MES store yard complete all as specified and directed.
S&F factory made epoxy polyster poweder coated distribution board SP & N8 way fabricated from minimum 1.6 mm thick CRCA sheet with metal double door (IP-43 protection) fixed flush to wall and suitable for universal mounting and including 200, Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one conforming to IS : 8623 alongwith cable end box for above DB all as specified and directed. NOTE : (a) MCB's Shall be measured and paid separately. (b) All cabels terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch
S&F single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 including taking down old MCB's complete all as specified and directed by Engineer-in-Charge (Make Standard Cat Part No DSMSCSPF006-32 or equivalent)
S&F single pole MCB 40 Amps, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘B’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 including taking down old MCB's complete all as specified and directed by Engineer-in-Charge
S&F double pole MCB 32 Amps, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘B’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 including taking down old MCB's complete all as specified and directed by Engineer-in-Charge
S&F in repair surface mounting 20 watt LED tube light fitting of 4 ft length connected with 23/.0076 twin core PVC flexible cable complete all as specified and directed.
S&F MCCB 125 Amp 3 pole 16 KA at 415 V with fixed thermal megnatic release complete all as specified and directed by Engineer-in-Charge
S&F in repair new generation energy saving and environmental friendly long life versatile pressure die cast alumonium IP-65 road way luminaire with high power 25 watt LED security light complete all as specified and directed by Engineer-in-Charge Make Havells LETBXU7PA6025 or equivalent
S&F factory made epoxy polyester powder coated distribution board TPN 4 way (VTPN MCCB DB) with metal double door (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for DPX 160, 4 pole MCCB and ELM as incommer and 12 SP MCBs outgoings complete all as specified and conforming to IS: 8623 along with cable end box for above DB including taking down old DBs complete all as specified and directed by Engineer-in-Charge NOTE :- (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
S&F metal type exhaust fan single phase 230/240V of 300mm sweep including cutting of holes in a round shape and including fixing the exhaust fan complete all as specified and directed by Engineer-in-Charge
M&L for earthing complete with galvanised steel earth plate electrode 60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed by Engineer-in-Charge
S&F of BLDC ceiling fans complete with remote and accessories 230 V, 1200 mm sweep BEE 5 star rated complete all as specified and directed.
S&F of electric storage water heater of capacity 25 Ltr with vitreous enamel coating with all accessories and fittings arrangements and testing after installation complete all as specified and directed.
M&L in repair GI Strip 25x4 mm galvanised iron strip complete all as specified and directed by Engineer-in-Charge
n s kumar and sons
Shivom Projects Private limited
n s kumar and sons
L G BUILDERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .