CWE SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
SOIL INVESTIGATION FOR PROVN OF 2.2KM SECURITY WALL WITH LIGHTENING ARRANGEMENTS AND 02 X GUARD ROOM ALONG THE PERIMETER OF 176 MILITARY HOSPITAL AT SRI GNAGANAGAR MILITARY STATION (3RD CALL)
2023_MES_581884_3
3005/E-PROCURE/CWE SGNR/JOB-04/E3
Limited
Survey
Works
90 days
HQ CWE SRI GANGANAGAR
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹0
₹4,260
Yes
10 May 2023
8 Apr 2023
24 Apr 2023
8 Apr 2023
22 Apr 2023
15 Apr 2023
Amount
Consultancy services for providing and detailing for "SOIL INVESTIGATION FOR PROVN OF 2.2KM SECURITY WALL WITH LIGHTENING ARRANGEMENTS AND 02 X GUARD ROOM ALONG THE PERIMETER OF 176 MILITARY HOSPITAL AT SRI GNAGANAGAR MILITARY STATION" with all the details as under:- (i) Grain size analysis/identification & classification of soil. (ii) Unit weight (bilk density), natural moisture content, liquid limit, plastic limit, Shrinkage limit, Plastic index, Specific gravity. (iii) Dry density, degree of saturation of soil. (iv) Free swelling index & swelling pressure if expansive soil is encountered. (v) Shear Parameters (C- analysis) (vi) Consolidation test & Permeability test. (vii) Depth of water table below ground level. (viii) Presence of loose soil, if any and its depth. (ix) If weak soil with lesser N value as specification in table-1 if IS 1893 (Part) 2016 is encountered then evaluation of liquefaction potential shall be assessed and remedial action to be adopted shall be specified. (x) SPT test shall be done at 1.0 m interval. (xi) Recommendation for filling under floor and filling under protection including plinth protection. (xii) For open foundation, calculation of net SBC at 1.5 m, 2 m, 3.0 m from sgear as well as settlement criteria. SBC values shall be calculated based on C-analysis as well as SPT value. For calculation formula given in IS 694036 shall be used. (xiii) Recommendation regarding type of foundation to be adopted and net SBC/pile capacity to be adopted. Also, recommendation shall be given regarding stability of soil stabilization required, if any. (xiv) Bore hole position duly marked on plan and their distance from adjacent prominent reference points. Plan size of bldgs, shall also be marked in the plan. This plan be signed be GE, AGE & soil consultant. (xv) Undisturbed soil sample shall be collected at 1.5 m interval and at change of strata. K-value of soil 0.5 m depth required in case of swimming pool and water retaining structure. Modules of subgrade reaction direct shear test on disturbed soil sample.
Research and Engineer Enterprises
National Soil Testing and Research Laboratories
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .