Financial Eligibility Criteria: (Ref: RB letter No. 2022/CE-I/CT/GCC- 2022/POLICY : Advance Correction Slip No.-1 dt 14.07.2022) The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-I, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The intending tenderers should possess a valid electrical contractor license at the time of opening of tender, issued by any state government & same should be submitted along with tender documents by all bidders including working contractors of this unit otherwise offer shall be summarily rejected....... IT SHOULD BE NOTED BY THE TENDERER THAT ELECTRICAL LICENSE UNDER RENEWAL AT THE TIME OF TENDER OPENING WILL NOT BE CONSIDERED AND OFFER WILL BE SUMMARILY REJECTED. IT IS THE RESPONSIBILITY OF TENDERER TO UPLOAD VALID ELECTRICAL CONTRACTOR LICENSE ON THE DATE OF TENDER OPENING.
All requisite documents mentioned in clause 3.7 of tender document attached pertaining to constitution of firm/concern. (As applicable).
31 conditions · 4 needing a document upload
The rate to be quoted by tenderer shall be inclusive of all state/central taxes including GST. THE TENDERER SHOULD UPLOAD VALID GST REGISTRATION CERTIFICATE ALONG WITH THE OFFER.
The tender shall comply with General Condition of contract (GCC),2022 of Indian Railways (file attached). and its latest amendment, if any. The tenderer shall submit the offer after duly satisfying himself/herself with the GCC,2022 in general.
Tenderers are required to upload the Bank details as per Annexure-XII (Real Time Gross Saving (RTGS)/National Electronic Fund Transfer (NEFT) Model Mandate Form)of tender document.
Tenderers are required to upload requisite details as per Annexure-VIIB (DETAILS OF CONTRACTUAL PAYMENT RECEIVED IN LAST THREE FINANCIAL YEARS AND CURRENT FINANCIAL YEAR) without which the offer is liable to be rejected.
Tenderers are compulsorily required to upload Affidavit as per Annexure-XXIV along with tender document, without which the offer will be considered incomplete and will be rejected summarily.
All requisite documents/credentials mentioned in clause 3.5 of tender document attached pertaining to his/their technical and financial eligibility. (As applicable).
All requisite documents mentioned in clause 3.7 of tender document attached pertaining to constitution of firm/concern. (As applicable).
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
After opening of tender, any document/credential pertaining to technical, financial eligibility and available Bid Capacity constitution of firm etc. shall neither be asked nor be entertained/ considered under any circumstances and no claim or representation whatsoever from the tenderer in this regard shall be entertained. Scanned copy of the documents, uploaded by the tenderer shall be clear & readable. However Railway reserves the right to ask for any clarification on the documents/credentials already submitted by the tenderer along with the offer. ii)Tenderer may have to produce the original Documents in physical form at short notice whenever asked by Railway at any stage of tender evaluation process or even after finalization of tender. iii)In E-tender, all submissions of documents are to be uploaded on web-site. There may be last minute hic-cups and delay in uploading the Documents and payment of Earnest Money etc. Tenderer's/Prospective bidders are advised to upload their offer well in time. Railway will not be responsible for any delay/non submission of offer due to any reason whatsoever
No post tender correspondence for submission of additional documents shall be entertained after opening of the Technical & Commercial offers. Even suo-moto post tender letters of the tenderer/s shall be treated as Null & Void.
Payment clause as per special conditions 100% payment will be done after successful supply, installation, testing and commissioning of actual work done by the tenderer and on certification by the Railway representative. No part payment shall be made for supply of material.
This tender complies with Public Procurement Policy (Make in India) Order 2017, dated 15/06/2017, issued by Department of Industrial Promotion and Policy, Ministry of Commerce, circulated vide Railway Board letter no. 2015/RS(G)/779/5 dated 03/08/2017 and 27/12/2017.
IF ANY DISCREPANCY IS FOUND IN THE TENDER DOCUMENT, NAMELY SOR ITEM DESCRIPTION, SPECIAL TENDER CONDITION ETC., CLARIFICATION CAN BE SOUGHT FROM THE OFFICE OF SRDEE/G/DLI, DRM OFFICE, STATE ENTRY ROAD, NEW DELHI.
This tender complies with Railway Board instructions for Startups (recognized by Department of Industrial Policy and Promotion, Ministry of Commerce and Industry) for exemption from payment of Bid Security as detailed in GCC 2022 as amended from time to time. Such Startup firms may note that no other exemption is applicable to them in this particular tender.
On account payment, contractor shall submitted indemnity bond with validity up to the completion/extended period in the prescribed format (please refer Annexure-XXVIII) at the contractor's cost, vesting the ownership of such material with the railways.
Electrical work regarding Augmentation of power supply distribution system with other allied works at HNZM Railway station.
50-SRDEE-G-DLI-2025-26~NR
50-SRDEE-G-DLI-2025-26
Open
Works - General
6 Months
Delhi, Delhi
₹0
₹2.3 L
27 Jan 2026
2 Jan 2026
13 Jan 2026
63 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,69,24,656 | ||
| — | 1200.00 | — | — | ||
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation (upto 75-100 cm depth and not less than 35 cm wide ), sand cushioning, protective covering and refilling the trench etc. as required as per detail drawing approved by competent authority and conforming to IS 1255 (Reviewed in 2016) or latest & as per explanatory note . Upto 35 sq. mm | — | — | — | 4,22,400 | |
| — | 900.00 | — | — | ||
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation (upto 75-100 cm depth and not less than 35 cm wide ), sand cushioning, protective covering and refilling the trench etc. as required as per detail drawing approved by competent authority and conforming to IS 1255 (Reviewed in 2016) or latest & as per explanatory note. Above 95 sq. mm and upto 185 sq. mm | — | — | — | 4,20,300 | |
| — | 700.00 | — | — | ||
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation (upto 75-100 cm depth and not less than 35 cm wide ), sand cushioning, protective covering and refilling the trench etc. as required as per detail drawing approved by competent authority and conforming to IS 1255 (Reviewed in 2016) or latest & as per explanatory note. Above 185 sq. mm and upto 400 sq. mm | — | — | — | 3,54,900 | |
| — | 400.00 | — | — | ||
| Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation(upto 75-100 cm depth and not less than 55 cm wide& maintaining gap not less than 20 cm between the cables), sand cushioning, protective covering and refilling the trench etc as required as per detail drawing approved by competent authority and conforming to IS 1255 (Reviewed in 2016) or latest & as per explanatory note. Upto 35 sq. mm | — | — | — | 1,15,200 | |
| — | 300.00 | — | — | ||
| Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation(upto 75-100 cm depth and not less than 55 cm wide& maintaining gap not less than 20 cm between the cables), sand cushioning, protective covering and refilling the trench etc as required as per detail drawing approved by competent authority and conforming to IS 1255 (Reviewed in 2016) or latest & as per explanatory note . Above 95 sq. mm and upto 185 sq. mm | — | — | — | 97,500 | |
| — | 200.00 | — | — | ||
| Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation(upto 75-100 cm depth and not less than 55 cm wide& maintaining gap not less than 20 cm between the cables), sand cushioning, protective covering and refilling the trench etc as required as per detail drawing approved by competent authority and conforming to IS 1255 (Reviewed in 2016) or latest & as per explanatory note. Above 185 sq. mm and upto 400 sq. mm | — | — | — | 76,200 | |
| — | 400.00 | — | — | ||
| Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.In case of any demolition of PCC, RCC, road, wall surface etc. the contractor should ensure repairing of the same on own expenses as per site requirement and satisfaction of railway representative conforming to IS 1255 (Reviewed in 2016) or latest & as per explanatory note. Upto 35 sq. mm (clamped with 1mm thick saddle) | — | — | — | 23,600 | |
| — | 300.00 | — | — | ||
| Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.In case of any demolition of PCC, RCC, road, wall surface etc. the contractor should ensure repairing of the same on own expenses as per site requirement and satisfaction of railway representative conforming to IS 1255 (Reviewed in 2016) or latest & as per explanatory note. Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp). | — | — | — | 49,200 | |
| — | 100.00 | — | — | ||
| Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.In case of any demolition of PCC, RCC, road, wall surface etc. the contractor should ensure repairing of the same on own expenses as per site requirement and satisfaction of railway representative conforming to IS 1255 (Reviewed in 2016) or latest & as per explanatory note. Above 185 sq. mm and upto 400 sq. mm (clamped with 25/40x3mm MS flat clamp). | — | — | — | 24,200 | |
| — | 500.00 | — | — | ||
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade(HT) of following size direct in ground including excavation (upto 75-100 cm depth and not less than 35 cm wide), sand cushioning, protective covering and refilling the trench etc. as required as per detail drawing approved by competent authority and conforming to CPWD General Specifications for Electrical Works Part-II External -2023 and CPWD DSR(E&M) 2025 Item No.22.1.2 and IS 1255 (Reviewed in 2016) or latest & as per explanatory note. above 120 sq.mm and upto 400 sq.mm | — | — | — | 3,47,000 | |
| — | 4.00 | — | — | ||
| Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required as per IS 13573:2011 (Reviewed in 2024) or latest & other relevant IS/IEC standard and conforming to CPWD General Specifications for Electrical Works Part-II External -2023 and CPWD DSR(E&M) 2022 Item No.10.5.2 & as per explanatory note. 150 sq. mm | — | — | — | 80,400 | |
| — | 30.00 | — | — | ||
| Earthing with G.I. earth pipe 4.5 metre long, 40mm dia. class-B as per IS:3043:2018 (or latest version) including construction of masonry enclosures with hinged cover plate of cast iron with locking arrangement (appx size 400mm * 400mm on top),provision of Earth plate,connections from Earth electrode to switch gear/pole as per drawing including accessories,having locking arrangement and watering pipe etc. with charcoal/coke and salt as required & as per explanatory note . | — | — | — | 1,72,530 | |
| — | 250.00 | — | — | ||
| Supplying and laying 8 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required as per IS 3043 : 2018 or latest & as per explanatory note . | — | — | — | 2,500 | |
| — | 21.00 | — | — | ||
| Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt) as required as per IS 3043 : 2018 or latest conforming to CPWD General Specifications for Electrical Works Part-I External -2023 and CPWD DSR(E&M) 2022 Item No.5.4 & as per explanatory note . | — | — | — | 1,56,912 | |
| — | 105.00 | — | — | ||
| Supplying and laying 40 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) as per IS 3043 : 2018 or latest & as per explanatory note . | — | — | — | 15,225 | |
| — | 12.00 | — | — | ||
| Earthing with 600x600x3mm thick copper plate earth electrode as per IS 3043(Latest version), to achieve earth resistance less than one ohm, including construction of masonry enclosure with hinged cover plate of cast iron with locking arrangement (Approx.size 600x600 mm) on top, watering pipe, connections from earth plate to top with 40x6mm copper stip in 50 mm dia pipe class ' B' provision of earth plate as per drawing and technical specification as per IS 3043 : 2018 or latest & as per explanatory note . | — | — | — | 1,31,004 | |
| — | 60.00 | — | — | ||
| Supplying and laying 40 mm X 6 mm copper strip at 0.3 metre below ground as strip earth electrode confirming to relevant IS as per IS:3043/1987 (Latest version), including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) as per IS 3043 : 2018 or latest & as per explanatory note . | — | — | — | 1,10,100 | |
| — | 300.00 | — | — | ||
| Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required and conforming to conforming to CPWD General Specifications for Electrical Works Part-II External -2023 and CPWD DSR(E&M) 2022 Item No.4.6.2 and IS/IEC 61537 & as per explanatory note . 150 mm width X 50 mm depth X 1.6 mm thickness | — | — | — | 2,14,800 | |
| — | 2.00 | — | — | ||
| "Design, manufacturing and supply of package type 11 kV/433 V outdoor substation, 630 KVA made from GI enclosure complete as required conforming to IEC 62271-202 only and relevant IS ,as per explanatory note ,specification and Tech Spec-I as applicable for the rating , internal arc of 21 KA/1 sec .IAC A & B on HT compartment. 630 KVA 11 KV/433 V DYN oil type, hermetically sealed energy efficiency level 2 tansformer (BEE star Rated 2) with corrugated wall , without conservator , type of design & Top Bushing for HT & LT with off load tap switch of rating +5% to -5% @ 2.5%. 11 kV 630 A 21 KA/3 sec Non extensible Ring main unit compact switchgear consisting of 3 no. fixed motorized VCB module in SF6 insulated stainless steel enclosure (2.5 mm thick, SS304 grade) and with Bus PT metering module. Incomer from transformer : 800 Amps 433 V 4 P 50 Hz 50 KA fixed motorized type Air circuit breaker (ACB)- 01 No. 400 A MCCB 4P 36 KA with with adjustable thermal & fixed magnetic release = 02 Nos.(Outgoing) 200/250 A MCCB 4P 36 KA with with adjustable thermal & fixed magnetic release = 02 Nos.(Outgoing)" | — | — | — | 99,60,000 | |
| — | 1.00 | — | — | ||
| Supply, Fixing, Testing and Commissioning of outdoor type, 11 kv SF6 type extensible and motorized, 3-way smart ring main unit (RMU) complete one VCB and two LBS and auxiliary transformer, FPI but without FRTU as per nigams technical specification no. CSC-117/R- III/DH/UH/P&D/2018-19 with latest amendments as tech spec-II. The RMU shall have complete wiring and capability to connect/integrate the FRTU in future for enabling the SCADA functionality & conforming to IEC 62271 (latest). | — | — | — | 8,30,720 | |
| — | 3.00 | — | — | ||
| "Design, Supply, fixing, testing and commissioning of front operated double door, out door type weather proof feeder pillar body made of CRCA sheet sheet with anti corrosion treatment and suitable having IP 65 protection (MCCB - Incoming & MCCB - Outgoing) comprising with the following MCCB's fixed in it of make: Havells, Siemens, L&T, Schneider, Legrand or equivalent conforming to IEC 60947 or latest with digital measuring instrument & bus-bar arrangement conforming to IS/IEC 61439 or latest and IE rules and site requirement. It should be dust proof and vermin proof, and powder coating and also provide polyamide cable gland swith IP 68 protection & should suit the number,type and size of power cables a) 4P MCCB 400Amps 36 kA with adjustable thermal & fixed magnetic release =01 Nos. (Incoming). b) 4P 400 Amps on load change over switch (COS)=01 No. c) 4P MCCB 250Amps 36 kA with adjustable thermal & fixed magnetic release =04 Nos. (Outgoing) d) 4P MCCB 125Amps 36 kA with adjustable thermal & fixed magnetic release =04Nos. (Outgoing). It should come with anti corrosion protection, should be rodent entry proof with proper cable glands for incoming and outgoing. Minimum clearance = 8 mm (between phases, or phase-to-earth in air). Minimum creepage = 14 mm (along insulation surface). If used in high pollution environments (PD4, e.g. coastal area, cement plants) creepage requirement increases as per the IEC specification It must comply with IEC 61439 performance tests for mechanical strength, corrosion resistance, IP/IK rating, and thermal stability and should comply with other relevant IS/IEC." | — | — | — | 11,15,202 | |
| — | 3.00 | — | — | ||
| "Design, Supply, fixing, testing and commissioning of front operated double door type weather proof feeder pillar having IP 65 protection (MCCB - Incoming & MCCB - Outgoing) comprising with the following MCCB's fixed in it of make: Havells, Siemens, L&T, Schneider, Legrand or equivalent conforming to conforming to IEC 61439 or latest with digital measuring instrument IEC 60051 & IS 1248 & bus-bar arrangement conforming to IS:13032, IS/IEC 61439,IS 12640 or latest , IP65 protection and site requirement and also and as per IS, IE rules and site requirement. 4P MCCB 250Amps 36 kA with adjustable thermal & fixed magnetic release = 01 No. (Incoming) 4P MCCB 125Amps 36 kA with adjustable thermal & fixed magnetic release = 02 No. (outgoing) 4P MCCB 63Amps 36 kA with adjustable thermal & fixed magnetic release = 04 No. (outgoing) It should come with anti corrosion protection, should be rodent entry proof with proper cable glands for incoming and outgoing. Minimum clearance = 8 mm (between phases, or phase-to-earth in air). Minimum creepage = 14 mm (along insulation surface). If used in high pollution environments (PD4, e.g. coastal area, cement plants) creepage requirement increases as per the IEC specification It must comply with IEC 61439 performance tests for mechanical strength, corrosion resistance, IP/IK rating, and thermal stability and should comply with other relevant IS/IEC." | — | — | — | 3,23,727 | |
| — | 8.00 | — | — | ||
| Supply, Fixing, Testing and Commissioning of LT distribution board double door outdoor type made up of CRCA sheet, phosphatised powder painted, anti corrosion protection complete with bus bar, neutral link, earth point, Din rail and prewired confirming to IS:13032, IS/IEC 61439,IS 12640 , or latest of make ABB, Havells, Siemens, L&T, Schneider, Legrand, C&S or equivalent with following items of matching make to be fixed in distribution board, conforming to IE rules and site requirement. 63A 4P RCBO 30/100/300mA= 01 No. (Incoming) 6-32A MCB SP ""C"" Series = 18 Nos. (Outgoing) It should be rodent entry proof with IP 65 protection having proper wiring with circuit labelling. Also it should have proper entry and exit provision of cable with cable glands as per site requirement.It should comply with all relevant IS/IEC standards & as per explanatory note." | — | — | — | 1,05,656 | |
| — | 20.00 | — | — | ||
| Provision of out door type distribution box complete with 4 nos Aluminium bus bars 250A capacity fabricated with 14 SWG MS sheet steel, dust and vermin proof. as per Technical spec and site requirement.It should be rodent entry proof with IP 65 protection having proper wiring with circuit labelling. Also it should have proper entry and exit provision of cable with cable glands as per site requirement conforming to IS/IEC 61439 (or latest ) as per explanatory note . | — | — | — | 97,720 | |
| — | 200.00 | — | — | ||
| Supply, Laying, Testing & Commissioning of HDPE pipe of 160 mm dia having material grade PE-100, wall thickness PN-6 and confirming to IS-4984 or latest as per IE rules and site requirement for cable laying through HDPE pipe of 160mm diameter by HDD method as per IS - 1255 or latest & IE rules and site requirement & as per explanatory note . | — | — | — | 2,15,000 | |
| — | 500.00 | — | — | ||
| Design, supply,erection, testing and commissioning of 40A,Lighting BBT( Bus Bar truncking),Copper conductor,3P+100% neutral,2.7kA for 0.1 sec,IP 55 complete by suspension on ceiling of following capacity Lighting Bus Trunking for use on 3 phase 4 wire 400(+-10%) volts, 50Hz A.C. supply with sheet metal clad (GI) enclosure made of hot-galvanizes steel treated according to UNI EN 10327/ extruded aluminium housing,necessary joints, elbow joints, provision of tapping. The enclosure shall provide a protection not less than IP- 55. The enclosure shall provide a protection of IK 07 against mechanical impact. The busbar Trunking shall comply with standard IEC 61439-6 & As per Explanatory Note with following items. (a) 40A Lighting Bus with IP-55, Cu Conductor, 4P | — | — | — | 11,82,500 | |
| — | 4.00 | — | — | ||
| (b) 40A End feed unit with provision of RCBO but without RCBO and with end cap.for Bus bar Trunking as per description of SOR item No 26 .As per Explanatory Note . | — | — | — | 20,760 | |
| — | 200.00 | — | — | ||
| (c) Suspension hanger for Bus bar Trunking as per description of SOR item No 26 .As per Explanatory Note . | — | — | — | 18,200 | |
| — | 100.00 | — | — | ||
| Design,manufacturing, supply, fixing, testing and commissioning of TAP-Off box plug in 16A, single phase selection (1 PH+N+E) with provision of fuse and rating of fuse as per site requirement complete As per Explanatory Note . | — | — | — | 1,08,300 | |
| — | 50.00 | — | — | ||
| Design,manufacturing, supply, fixing, testing and commissioning of TAP-Off box plug in 16A, three phase selection ( 3 PH+N+E) with provision of fuse and rating of fuse as per site requirement complete & As per Explanatory Note . | — | — | — | 65,900 | |
| — | 1.00 | — | — | ||
| "Supply, erection,testing and commissioning of 5500 VA inverter as per IS 16242 (part 1) 2025/ IEC 62040-1 : 2017 or latest, A.C.input voltage 180V-260V, DC input voltage 72V, out put voltage same as supply voltage,when inverter is working 220V +(-) 10%, output frequency 50 + (-) 0.5%, output wave form:sine wave,back up time minimum 120 minutes, Protection: undervoltage at battery terminal, overload battery over charge battery deep discharge,Battery charge:constant current thyristor controlled for extra wide range. Supply and erection of 06 Nos. 12V, 200 Amp Hour LMLA tubular battery conforming to IS 13369:1992 (reaffirmed 2017) complete in all respect as per specification & As per Explanatory Note . Make of inverter: Microtek, Sucam,Luminous along with Exide, OKAYA, AMRON, Microtek make Battery or equivalent. | — | — | — | 67,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .