Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAdmitted-Finance | ₹1.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.2 Cr+₹2.5 L (2.19%)Admitted-Finance | ₹1.2 Cr+₹2.5 L (2.19%) | L2 | Admitted-Finance |
| 3 | L3₹1.2 Cr+₹5.6 L (4.91%)Admitted-Finance | ₹1.2 Cr+₹5.6 L (4.91%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Hindustan Electric Work L2 | M/s S S Associates L3 | M/s A V G Infratech Private Limited L1 |
|---|---|---|---|---|---|---|
| 1.00Safe Loading, Carriage and then safe unloading of the following material from Store Centres Under the jurisdiction of EE ESD Ayodhaya to dump site proper stacking. | ||||||
| 2.00 | PCC pole 9 Mtr. | 283 | No. | 800 ₹2,26,400 | 800 ₹2,26,400 | 770 ₹2,17,910 Lowest |
| 3.00 | STP 11 Mtr. | 76 | No. | 800 ₹60,800 | 800 ₹60,800 | 770 ₹58,520 Lowest |
| 4.00 | M.S. Top Channel 125x65 mm 3200 mm | 88 | No. | 50 ₹4,400 Lowest | 50 ₹4,400 Lowest | 50 ₹4,400 Lowest |
| 5.00 | M.S. Angle 65x65x6 mm Bracing, 4300 mm | 74 | Set | 50 ₹3,700 Lowest | 50 ₹3,700 Lowest | 50 ₹3,700 Lowest |
| 6.00 | MS Angle for guarding 65x65x6 mm, 3500 mm long | 812 | Kg. | 15 ₹12,180 Lowest | 15 ₹12,180 Lowest | 15 ₹12,180 Lowest |
| 7.00 | GI Wire 8 SWG | 145.2 | Kg. | 15 ₹2,178 | 15 ₹2,178 | 14 ₹2,032.8 Lowest |
| 8.00 | GI Wire 6 SWG | 1,436.8 | Kg. | 15 ₹21,552 | 15 ₹21,552 | 14 ₹20,115.2 Lowest |
| 9.00 | 33 KV Disc Insulator B & S Type polymer | 201 | No. | 100 ₹20,100 | 100 ₹20,100 | 90 ₹18,090 Lowest |
| 10.00 | V Type channel cross arm | 238 | No. | 150 ₹35,700 | 150 ₹35,700 | 145 ₹34,510 Lowest |
Tender Value
₹1.2 Cr
EMD Value
₹1.2 L
Closing Date
9 Oct 2024, 2:00 pmClosed
SE EWC AYODHYA
OFFICE OF THE SUPERINTENDING ENGINEER ELECTRICITY WORKS CIRCLE, AYODHYA
22/SE/EWC/AYO/2024-25
2024_MVVNL_959817_1
22/SE/EWC/AYO/2024-25
Open Tender
Electrical Works
Item Wise
90 days
SULTANPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,900
SUPERINTENDING ENGINEER, ELECTRICITY WORKS CIRCLE
₹1.2 L
26 Oct 2024
28 Sept 2024
9 Oct 2024
28 Sept 2024
9 Oct 2024
28 Sept 2024
Amount
Safe Loading, Carriage and then safe unloading of the following material from Store Centres Under the jurisdiction of EE ESD Ayodhaya to dump site proper stacking.
PCC pole 9 Mtr.
STP 11 Mtr.
M.S. Top Channel 125x65 mm 3200 mm
M.S. Angle 65x65x6 mm Bracing, 4300 mm
MS Angle for guarding 65x65x6 mm, 3500 mm long
GI Wire 8 SWG
GI Wire 6 SWG
33 KV Disc Insulator B & S Type polymer
V Type channel cross arm
33 KV Pin Insulator polymer type
Stay Wire 7/8 SWG
Cost of ACSR Dog Conductor
Cost of 33 KV 3x300 sq mm XLPE Cable
33 KV Outdoor jointing Kit for 3x300 sq mm XLPE Cable
33 KV Straight through jointing Kit for 3x300 sq mm XLPE Cable
M.S. Channel 125x65 (for Structures )
M.S. Angle 75x75x6 (for Structures )
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection of Single Pole for 33 KV Line on 9.0 Mtr PCC Pole with fitting of necessary clamp & other acessories like 1 no Channel Cross Arm, 3 No. polymer Pin insulator as per norms. (Contractor shall provide , necessary clamps, F-brackets, Nut - Bolts, Washers etc.)
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection for Sectional Double pole for 33 KV Line on 9.0 Mtr PCC Pole with fitting of necessary clamp & other acessories like 1 No Top channel of 125x65x6 mm size 3200 mm , Bracing angle 1 set.,33 Kv , Disc insulator 6 No. and 3 No. Pin insulator as per norms. (Contractor shall provide , E- Bracket , necessary clamps, Disc Fitting, Nut - Bolts etc.)
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection for Sectional Double pole for 33 KV Line on 11.0 Mtr STP Pole with fitting of necessary clamp & other acessories like 1 No Top channel of 125x65x6 mm size 3200 mm, 6 No. Disc. Fitting , Bracing angle 1 set., 33 kv Disc insulator 6 No. and 3 No. Pin insulator as per norms. (Contractor shall provide , E- Bracket, necessary clamps, Disc Fitting, Nut - Bolts etc.)
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection of Single Pole for 33 KV Line on 11 Mtr ST Pole with fitting of necessary clamp & other acessories like 1 No. Channel Cross Arm,3 No. polymer Pin insulator as per norms. (Contractor shall provide necessary clamps, F-brackets/top cleet, Nut - Bolts, Washers etc.)
Erection of single stud pole support on PCC Pole 9.0 Mtr long with fixing of necessary clamps and other accessories required for erection. (Contractor shall provide necessary clamps, Nut - Bolts, Washers etc)
Erection of single stud pole support on STP Pole 11 Mtr long with fixing of necessary clamps and other accessories required for erection. (Contractor shall provide necessary clamps, Nut - Bolts, Washers etc)
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection for Dead end Double pole for 33 KV Line on 11.0 Mtr STP Pole with fitting of necessary clamp & other acessories like 1 No Top channel of 125x65x6 mm size 3200 mm . , Bracing angle 1 set., 03 No disc insulator etc as per norms. (Contractor shall provide all necessary clamps, Nut - Bolts & washer and E-bracket, Disc fitting if required etc)
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection for Dead end Double pole for 33 KV Line on 9.0 Mtr Pcc Pole with fitting of necessary clamp & other acessories like 3 No Top channel of 125x65x6 mm size 3200 mm . , Bracing angle 1 set. , 03 No disc insulator etc as per norms. (Contractor shall provide all necessary clamps, Nut - Bolts&washer and E-bracket, Disc fitting if required etc)
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection for Tri pole for 33 KV Line on 9.0 Mtr PCC Pole with fitting of necessary clamp & other acessories like 3 No Top channel of 125x65x6 mm size 3200 mm ,Disc insulator 6 No, 6 Polymer Pin insulator, Bracing angle 3 set, as per norms. (Contractor shall provide , necessary clamps, Disc fitting , Nut - Bolts etc.)
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection for Tri pole for 33 KV Line on 11.0 Mtr STP Pole with fitting of necessary clamp & other acessories like 3 No Top channel of 125x65x6 mm size 3200 mm ,Disc insulator 6 No, 6 Polymer Pin insulator, Bracing angle 3 set, as per norms. (Contractor shall provide , necessary clamps, disc fitting, Nut - Bolts etc.)
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection of Four pole for 33 KV Line on 11 Mtr ST Pole with fitting of necessary clamp & other acessories like 4 No. Top channel of 125x65x6 mm size 3200 mm, Bracing angle 4 set, 6 No. 33 kv disc insulator B &S , Pin insulator 09 No. as per norms. (Contractor shall provide , E- Bracket, necessary clamps, Disc Fitting, F-clamp , Nut - Bolts washers etc. )
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection of Four pole for 33 KV Line on 9.0 Mtr PCC Pole with fitting of necessary clamp & other acessories like 4 No. Top channel of 125x65x6 mm size 3200 mm, Disc Fitting 6 No. Bracing angle 4 set, 6 No. 33 kv disc insulator B &S , Pin insulator 09 No. as per norms. (Contractor shall provide , E- Bracket ., necessary clamps, Disc Fitting, F-clamp , Nut - Bolts washers etc. )
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection for Expoure Double pole for 33 KV Line on 11.0 Mtr STP Pole with fitting of necessary clamp & other acessories like 3 No Top channel of 125x65x6 mm size 3200 mm . , Bracing angle 1 set., and 9 No. Pin insulator as per norms. (Contractor shall provide all necessary clamps, Nut - Bolts&washer and e-bracket if required etc)
Safe Dragging/ Loading - unloading from dump site to pit site and Fabrication & erection for Expoure Double pole for 33 KV Line on 9.0 Mtr PCC Pole with fitting of necessary clamp & other acessories like 3 No Top channel of 125x65x6 mm size 3200 mm . , Bracing angle 1 set., and 9 No. Pin insulator as per norms. (Contractor shall provide all necessary clamps, Nut - Bolts&washer and e-bracket if required etc)
Cradle Guarding of 33 KV line at road crossing/ 11 KV line crossing, canal/telephone line crossing by fixing Guarding Angle 65x65x6 mm, 3500 mm at double pole and 2600 mm long at single pole by stringing and sagging of 3 No. G.I.wire with lacing and tightening with mounting. (Contractor shall provide Necessary clamps for fitting of guarding angle and 6 No. Eye hook&bolt 12x110 mm etc.)
Angle for Cross arm Support at Angle Location 65x65x6 mm 1600 mm long with clamps and nut & bolt. (All materials will be supplied by the contractor)
Cable stand Structure Fabrication & erection of 33 KV Cable Stand made of 02 No. M.S chanel 125x65x6 mm 3 Mtr. Jointed to each other by M.S Channel horizontally and also jointed to each other by means of 05 No. M.S Strip (m.s flat) 50x6 mm of size 200 mm long each by welding at actual distance interval as per norms. And grouting in block of 300x300x700 completely providing 02 no. cable clamps also and eathing by G.I strip 50x6 mm size with the earth mat of switchyard both side of legs and provideing clamps , post/ pin insulator for holding cable. (All the materials will be arranged by the contractor such that clamps nut bolts and civil materials except M.S channel.)
Nozeling and grouting of stay at sectional pole and extra stay sets at angle locations (All the civil material and 33 KV G.I stay set 20x1800 mm, stay clamp will be arranged by the contractor except stay wire)
Stringing, sagging, binding and Jumpering of ACSR Dog conductor. 3 Phase of 33 KV Line including fixing, mounting of P.G.clamp suitable for Dog Conductor at sectional point. (Contractor shall provide necessary PG clamps etc)
Laying & Dressing of 3x300 sq. mm XLPE Cable underground Double Circuit. Laying of double circuit 3x300 sq .mm XLPE Cable in normal soil by digging of trench 1050 mm deep, 750 mm wide including supply of required materials, as 1st class Bricks, Stone slabs and fine sand. Providing 150 mm fine sand cusion beneath, and 150 mm sand cusion above the cable. The cable shall be duly protected by Bricks, sand and stone slab. The inter axial spacing between two cables should be in between 0.25 to 0.04 M. After laying the cable refilling and ramming of the left out soil,closing the trench and leveling.
Installation of Heat Shrinkable Type cable jointing kits of following types/sizes for 33 XLPE Cable.
(a) Fixing of 33 KV 3x300 sq. mm Straight Through joints. (jointing kit supplied by dept.)
(b) Fixing of 33 KV 3x300 sq. mm Outdoor End Terminations (jointing kit supplied by dept.)
High Pressure testing to which 33 KV Line & cable to be stand for duration of 5 minutes after completion of Laying, Stringing, sagging, binding and Jumpering of ACSR Dog conductor. ( Testing equipment will be arranged by the contractor)
Hoisting of 33 KV Cable on existing/erected support with provision of MS Pipe 150 mm dia 3 mtr long suitable for 3x300 sq mm cable fixing of proper support and its clamping, providing long barral lugs 6 nos and P.G. Clamps & "Y" shape jumpering properly and 02 nos. supporting angle 65X65X6, 2240 mm long and making connection including supply of jumpering cable ,mounting clamps as per RESSPO Norms. (All material will be supplied by the contractor like M.S Pipe , P.G. Clamps, Al. Lug And Supporting Angle 65X65X6, 2240 mm and jumpering cable suitable for 33 KV jumper).
Grouting of following structure by digging of pit 1.5 Mtr/1.83 Mtr deep for 9.0 Mtr PCC / 11 Mtr STP respectively, placing stone pad at bottom 450x450 size foundation is provided with help of steel or wooden formers, groutung with 1:4:8 Ratio cement, sand & first class brick ballast 0.268/0.285 cu mtr for 9.0 mtr PCC Pole & 11 mtr STP, plinthing 0.3 Mtr above G/L and proper plastering.
11 Mtr ST Poles
9.0 Mtr PCC pole
Supply and fixing of a stone pad of size 300x300x75 mm at PCC/STP Bottom of the pit ( Contractor shall provide all materials)
Fabrication, Erection and grouting of route marker and marking 33 KV line by painting after grooving on the stone. (Contractor shall provide all materials)
Providing of barbed wire
Fixing of barbed wire on pole on STP/PCC pole fixing of barbed wire on the pole above 2750 mm ground level. Barbed wire wrapped for a distance of 0.9 mtr. with a pitch of 13.mm at a height. (All materials supplied by the contractor)
Fixing of Danger board . Supply and fitting of Danger board of size 250x200x2 mm 3650 mm above ground level with the help of proper size of nuts, Bolts , washers and clamps as per Respo norms. RESPO Drawing No-55 (All materials supplied by the contractor)
Fixing of Number plate . Supply and fitting of Number plate of size 250x200x2 mm 3650 mm above ground level with the help of proper size of nuts, Bolts , washers and clamps as per Respo norms. RESPO Drawing No-55 (All materials supplied by the contractor)
Earthing of Pole Earthing of Pole STP/PCC by 6 SWG Wire by providing and fixing of 20 mm dia' earthing rod 2.550 Mtr. long as per norms complete in all respect. (Contractor shall provide all the material Like Earthing rod, Earthing clamps and nut & bolt etc.)
Nozeling and grouting of stay (All the civil material and 33 kv G.I stay set 20x1800 , stay clamp will be arranged by the contractor except stay wire)
Petrolling in feet from starting to end and removal/lopping and chopping of tree branches which are lying in routre of 33 KV overhead line.
Providing of HDPE 6"Dia Pipe PN-6 Specification
Laying of cable & HDPE Pipe Laying of Single circuit 33 KV 3x300 Sq mm XLPE cable and HDPE Pipe by drilling method below NHAI road crossing. The cable be laid at the depth of 3 mtr from the under surface in HDPE pipe (200 mm. dia.) casing.
NOC will be granted from Central/ state Electrical safety department.( Final settlement of the payment will be done after providing receipt, agreement and permission paper).
restoring the road as it is before after completion of work
Permission of NHAI/PWD etc. for road crossing.( Final settlement of the payment will be done after providing receipt, agreement and permission paper)
permission of cutting and chopping of tree from forest deppt. ( Final settlement of the payment will be done after providing receipt, agreement and permission paper)
Carraige and erection of A-type tower (fully submerged) All materials will be provided by the contractor with stringing of ACSR Dog conductor
33 KV Disc Insulator B & S Type 70 KN porcelain
33 KV Disc fitting suitable B & S type porcelain Disc 70 KN
Galv. Stub
Galv. Towerpart
Nut Bolt & Accessories
Stub Setting
Excavation ( for-FS)
Cost of Concreting for all types of tower foundation including cost of cement,dewatering,shoring and shuttering, forming, curing but excluding cost of reinforcemnt (for-FS)
Steel Rainforcement
Erection of tower with fitting
Tack welding
Pipe Type Earthing
Number Plate
Danger Plate
Phase Plate in set of RYB
Bird guard
Hoisting of 33 KV Cable on erected support on 33 kv cable stand by using clamp with nut bolt and suitble size of G.I. pipe. (All material will be supplied by the contractor like G.I Pipe ,P.G. Clamps, Al. Lug And and jumpering cable suitable for 33 KV jumper).
Painting of poles Painting of poles with one coat of red oxide, two coats of enamel paint ISI mark. (All required material will be supplied by the contractor)
Hindustan Electric Work
M/s S S Associates
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.56 MB
BOQ_1668659.xls
BOQ • 0.29 MB
Tenderdocument22202425.pdf
Tender Documents • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .