Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.5 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹26.2 L+₹88,821 (3.51%)Rejected-Finance | L2 | Rejected-Finance HIGHER BID VALUE | |
| 3 | L3₹27.4 L+₹2.1 L (8.24%)Rejected-Finance | L3 | Rejected-Finance HIGHER BID VALUE | |
| 4 | L4₹28.0 L+₹2.7 L (10.7%)Rejected-Finance | L4 | Rejected-Finance HIGHER BID VALUE | |
| 5 | L5₹28.2 L+₹2.9 L (11.6%)Rejected-Finance | L5 | Rejected-Finance HIGHER BID VALUE |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
27 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL P M LAPALKAR
GE 869 EWS C/O 99 APO PIN-913869
REPAIR MAINT OF LT OVERHEAD LINES AND UNDER GROUND CABLES WITH CONNECTED WORKS AT LOWER LEIMAKHONG MIL STN
2020_MES_340828_1
8288/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
LEIMAKHONG
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
GE 869 EWS
₹50,000
Yes
23 Sept 2020
21 Jul 2020
29 Aug 2020
21 Jul 2020
27 Aug 2020
4 Aug 2020
60 days
Amount
E/M WORKS
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, poles struts, etc., not exceeding 10 Sqm on plan and laying of cables or pipes, not exceeding 1.5m in depth and getting out in hard/dense soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm as in soils complete all as specified and as directed.
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 mtr above the starting point as in soils complete all as specified and as directed.
Supply and spread sand in trenches as sand cushioning to underground cable for protection with dry fine river sand and provide required cover after punning down complete all as specified and directed. (Note: Thickness of sand cushioning after punning down will be measured and paid.)
Supply and laying well burnt sub class ‘B’ (clay) bricks ( designated 75) locally available best quality, laid dry in trenches for protection of underground cable all as specified and directed.
Dismantling of unserviceable Steel tubular poles/struts, any size including removal from site complete all as directed.
S&F steel tubular swaged poles (ISI Marked), type 410 SP 31 (Overall length 9.00 m) complete with cast iron base plate, finial taper plug, bolts, nuts screws and washers including painting two coats of black bituminous paint internally and externally up to planting depth and remaining external portion with two coats of aluminum paints over a coat of red oxide primer incl painting black and white alternate strips of 30cm each from ground level up to 1.5 meter and writing pole Nos with white paint on black back ground complete all as specified and as directed. (MAKE: Bansal Poles / Calcutta Poles / Jindal Poles / Kwality Steel - Kolkata / National Tubing Company / Nezone)
M&L for PCC M-7.5 grade (Nominal mix) using 40mm graded crushed stone aggregate as in foundation of pole complete all as specified and directed.
M&L for PCC M-10 grade (Nominal mix) using 20mm graded coarse stone aggregate as in coping of pole, concrete base work, protection of cable complete all as specified and directed.
Taking up/down worn out/ damaged / unserviceable XLPE/ PVC insulated underground cable armoured, heavy duty with aluminium conductors of any size, 1100V grade from trench/ duct/ pole/ wall/ pipes/ roof tops etc. complete all as specified and directed. (Note: Excavation & Earthwork will be measured & paid for separately)
Supply, laying, jointing, connecting & testing, LT UG cable XLPE insulated , PVC bedded , galvanised steel strip or wire armored, electric power cable ( heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sqmm 2 core ,laid in trenches / on poles / walls / in ducts / roof top etc. passing through pipes etc including jointing materials such as cable glands, lugs etc complete all as specified and as directed.
All as per serial item No. 12 above but for 10 Sqmm 4 Core.
All as per serial item No. 12 above but for 16 Sqmm 4 Core.
All as per serial item No. 12 above but for 25 Sqmm 3.5 Core.
All as per serial item No. 12 above but for 35 Sqmm 3.5 Core.
All as per serial item No. 12 above but for 50 Sqmm 3.5 Core.
All as per serial item No. 12 above but for 70 Sqmm 3.5 Core.
All as per serial item No. 12 above but for 120 Sqmm 3.5 Core.
All as per serial item No. 12 above but for 240 Sqmm 3.5 Core.
Supply and laying in repair 25mm bore GI tubing light grade as in cable protection pipe including all fittings complete all as specified and directed.
Supply and laying in repair 40mm bore GI tubing light grade as in cable protection pipe including all fittings complete all as specified and directed.
Dismantling of unserviceable worn out / weathered / damaged ACSR conductor, service feeder of any size and type from pole after disconnecting jumpers and insulator bindings complete all as specified and directed.
M&L for ACSR conductor of any size and type, maintaining standard sag including providing aluminum binding wire, aluminium jointing, jumpers etc on LT OH lines complete all as specified and directed
Dismantling rusted/damaged cross arm of MS channel or angle section from pole complete all as specified and directed.
M & L for cross arms, bracing, clamps and back plates fabricated from structural steel section including nuts, bolts, washers etc, drilling hole for bolts in any shape or size with welding, bending cold or hot including painting two coats of aluminium paint over a coat of primer complete all as specified and directed. (Confirming to Fe-209, Gde- E.165)
Dismantling damaged insulators of any type and any size complete all as directed.
S&F pin type porcelain insulator of size 100 mm height, 65mm dia, vitreous, white, brown or green including one galvanized mild steel spindle, two galvanized iron washer and one galvanized iron nut for 1100 volts grade complete all as specified as directed. (Make: BHEL/ Jaypuria Brothers/ Pactil/ Southern Insulators)
S&F shackle type insulator, porcelain, vitreous, white, brown or green, 75mm height 90mm dia for working pressure of 1100 volts including galvanized steel straps of section 31x3mm, 12mm dia of bolts, washers and nuts complete all as specified and directed. (Make: BHEL/ Jaypuria Brothers/ Pactil/ Southern Insulators)
Supply and fix loop type insulator, vitreous porcelain, white, brown or green small size, with overall dimensions 65 x 90mm, clearance of hole 16mm complete all as directed.(Make: BHEL/ Jaypuria Brothers/ Pactil/ Southern Insulators)
Material and labour for cutting of road/ hard standing n exc 20cm width and n exc 60cm in depth for laying of cable protection pipe including making good the disturbed road/hard standing by providing PCC (1:2:4) type B1 to match with existing surface complete all as specified and directed.
Dismantling stay assembly complete all as directed
Material and labour for stay assembly 20 mm dia complete with accessories as shown in electrical plate No. 1 complete all as specified and directed. (Note : Loop type insulator, stay clamps, excavation and concrete shall be measured separately)
M&L for galvanized stay strand of size 7/3.15 mm in replacement complete all as specified and directed.
M&L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size including taking down old damaged plate complete all as specified and directed
M&L for cleaning, scrapping, preparing of old painted steel tubular pole 9m long and applying one coat of aluminium paint to pole and accessories / fittings whatever fixed on pole including marking pole No on each pole with yellow SE paint with 5cm large bold letters on black background of suitable size at a height of 2m above GL and painting 50mm wide coloured alternate strips of yellow and black with 2 coats of synthetic enamel paint upto a height of 1.5m from coping of pole complete all as specified and directed.
Trimming / cutting of the tree branches / bushes which falls within a clear distance of 3 meter from all sides from the LT over head conductor & within line of conductors, and shifting waste to nearby waste depot & cleaning the area complete all as directed. (Note :- Tree branches/Bushes falling on both sides of OH lines per metre run of OH lines shall be measured for the purpose of payment)
Dismantling and disconnecting of old unserviceable / Burnt MCCBs of size 63 to 630 Amps complete all as directed.
S&F MCCB 4 pole, 415 V, adjustable type 63 Amp with breaking capacity 36KA complete all as specified and directed.
S&F MCCB 4 pole, 415 V, adjustable type 125 Amp with breaking capacity 36KA complete all as specified and directed.
S&F MCCB 4 pole, 415 V, adjustable type 160 Amp with breaking capacity 36KA complete all as specified and directed.
S&F MCCB 4 pole, 415 V, adjustable type 200 Amp with breaking capacity 36KA complete all as specified and directed.
S&F MCCB 4 pole, 415 V, adjustable type 250 Amp with breaking capacity 36KA complete all as specified and directed.
S&F MCCB 4 pole, 415 V, adjustable type 400 Amp with breaking capacity 36KA complete all as specified and directed.
S&F MCCB 4 pole, 415 V, adjustable type 630 Amp with breaking capacity 50KA complete all as specified and directed.
Taking down old unserviceable service cable including batten/ suspending wires complete all as specified and directed.
S&F Service wire connection with one twin core 10 sq mm, 2 core, 1100 volts grade heavy duty flat or circular cable, multi stranded aluminium conductor, PVC insulated served with inner sheathing of PVC tape armoured, suspended by insulating hangers not more than one mtr apart incl 4mm dia GI suspension wire complete all as specified and directed.
M&L for earthing complete with galvanized steel plate electrode 600 X 600 X 6 mm thick buried directely in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level connected to aluminium earth strip of size 25 x3mm as earthing lead by means of galvanized steel bolts,nuts check nuts and washers and other end connected with to Transformer, DG sets, Pannel board etc as directed including funnel, 20 mm bore, light grade galvanized iron pipe, wire mesh charcoal of coal dust and common salt in alternative layer all around the earth electrode compacted thickness 15cm with concrete pit in PCC 1:3:6 type C1 50 mm thick pre cast RCC 1:2:4 type B1 with 8mm dia cover slab set in CM (1:4) reinforcement with 8mm dia deformed bars @ 15 cm C/C and suitable handle of 10mm dia MS round bars, including earth work as required complete all as shown in electrical plate No. 3 of MES schedule Part I and testing complete all as specified and as directed. (Note: GI Earthing strip upto 7.5m in length is deemed to be included in the unit rate. The Strip required beyond 7.5m shall be measured and paid for separately)
S&F 25 x 3mm aluminium strip in repair for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required including taking down damaged strip complete all as specified and directed.
M/S Satish Chand Agarwal
M/S BIJOYA LAXMI ENTERPRISE
MANI PRASAD GUPTA
M/S N JADUMANI SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .