| 1 | L1₹41.2 LAccepted-AOC | L1 | Accepted-AOC Awarded being lowest bidder | |
| 2 | L2₹44.2 L+₹2.3 L (5.41%)Rejected-AOC | L2 | Rejected-AOC Other than lowest bidder | |
| 3 | L3₹45.3 L+₹3.4 L (8.11%)Rejected-AOC | L3 | Rejected-AOC Other than lowest bidder |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
21 May 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (P) AF Gurgaon
GE (P) AF Gurgaon Near Atul Kataria Chowk Gurgaon 122005
GE( P) AF/GUR 09/2021-22 IMPROVEMENT TO BUILDING NO P 05 NEAR LGS SECTION AT 13 BRD AF STN PALAM UNDER GE( P) AF GURGAON
2021_MES_437981_1
GE(P)AF/GUR-09/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE (P) AF Gurgaon
AS SPECIFIED IN NIT
10 documents required · 10 mandatory
₹500
GE (P) AF Gurgaon
₹96,000
Yes
31 May 2021
23 Apr 2021
24 May 2021
23 Apr 2021
21 May 2021
7 May 2021
60 days
Amount
Schedule-A
Taking down existing bitumen felt roof treatment including cement mortar bedding and cleaning the surface and removal outside the MOD land, complete all as specified and directed.
M&L for 15 mm thick cement plastering in CM 1:4 on brick/concrete surfaces of roof and parapet, mixed with water proofing compound, finished even and smooth without using extra cement (Including 4 Story building) complete all as specified and as directed by Engineer-in-Charge. Note :- Water proofing compound shall be measured & paid separately.
Supply only water proofing liquid compoundcomplete all as specified and directed by Engr-in-Charge. :Make : DR. FIXIT PIDE PROOF LW, CICO, FOSROC.
Cleaning top surfaces by brooming, wire brushing, removing grass, raking out joints to receive plaster and removing debris, grass etc outside the defence land complete all as specified and directed by Engineer-in-Charge. Note :- 1. Plaster shall be measured and separately under appropriate item of Sch ‘A’. 2.Rate of this item is inclusive of diconnect fitment at water tank or solar heater etc and refixing in the same position after compeleting of roof treatment.
M&L for water proofing treatment of roof consisting as under:- (a) Applying evenly a coat of bituminous primer conforming to IS-3384:1986 @ 0.30 litre/sqm including preparation of roof surfaces (b) Applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg/Sqm on plaster surface all as specified. (c) A layer of 3mm thick APP polymeric membrane of weight not less than 3.00 kg/sqm, reinforced with polyester non-woven fabric (weight not less than 160gm/sqm), duly sealed at over laps & joints with end laps of the 10cm and side over laps of 7.5cm by flame (by torch application) all as per manufacturer’s instructions, complete all as specified and directed.
Taking down Cement Plaster/Grit Wash from wall and ceiling of any description from Brick/concrete surfaces including raking out Joints, hacking for Key, scrubbing down with Water, etc., and removing same from the Site(s), complete all as specified and as directed. (Note :- Rate included for four storey building including scaffolding and all safety measures)
M&L for 15mm thick rendering in CM 1:4 on fair faces of brick or concrete surfaces including finishing even and smooth without extra cement all as specified and as directed by Engineer in Charge.
M&L for 5mm thick rendering in CM 1:3 on concrete/gunniting surface as in ceiling finished even and smooth w/o using extra complete all as specified and directed by Engr-in-charge
M&L for 15mm thick rendering on brick or concrete surfaces in internal surfaces in cement mortar 1:6, finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand: 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified (Payment for providing grooves shall be made separately).
M&L for forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge.
M&L for preparation of newely plastered ceiling surface and applying three coats of white wash complete and all as specified and as directed.
M&L for preparing new plastered walls surface and applying two coat of exterior emulsion paint 100% acrylic of approved colour over a coat of primer including 1 to 2 mm thick birla putty punning complete all as specified and directed by Engineer-in-charge. Make-Asian (Apex Ultima) paints/Berger (Whether coat long life) including necessary scaffolding upto 4th floor.
M&L for preparing new plastered wall surface and applying two coat of Distemper oil emulsion over a coat of primer including 1 to 2 mm thick birla putty punning complete all as specified and as directed by Engineer-in-charge. Make: Asian Paint (Tractor)/Berger paints (Bison super)
Demolition of Cement Concrete (un-reinforced) of any description, not exc. 150mm thickness (above or below Ground Level) and removing the same from Site(s), complete all as specified and as directed.
M & L PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base 75 mm thick finished even and fair all as specified.
M&L for 150mm thick PCC 1:2:4 Type B2 (using 40mm graded stone aggregate) as in Floor/hard standing in line and level and laid in alternate panel of size not exc 4 sqm each including tamping and top surface make rough, whilst the concrete is green complete all as specified and as directed by Engineer in Charge.
M&L for 20mm thick wear proof topping by using approved metalic floor hardner as specified, laid on concrete floors and pavings in panels after applying neat cement slurry @ 3.00Kg/Sqm and top surface finished even and smooth complete all as specified and as directed by Engineer in Charge.
M&L for forming construction joint 30mm deep and 10mm wide cleaned and filled with sealing compound Gde "A" complete all as specified and as directed.
Excavation in post holes not exc 0.5 Cum, getting out, returning filling in layers n exc 25cm in thickness and removing surplus soil to a distance n exc 50 surface in hard/dense soil complete all as specified and as directed by Engineer in Charge.
M & L for PCC 1:3:6 Type C2 (using 40mm Graded stone aggregate) as in for fixing posts, bed plates, anchorage blocks, corbels, brackets, including necessary form work etc complete all as specified and as directed by Engineer in Charge. mortar complete with joints to match
M&L for Mild steel work as column etc. for frame work of rafter/purlin for roof including cutting welding and all necessary drilling,bolting or riveting etc. Complete conforming to Fe 410 W complete all as specified and as directed by Engineer in Charge.
M&L for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed in repair with self tapping J hooks including dismantling of existing sheet in any position complete all as specified and directed by Engr-in-Charge.
M & L for excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation and getting out in hard/dense soil complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
Removing excavated soil to a distance n exc 50m and deposit complete all as specified and as directed by Engineer in Charge.
M & L for PCC (1:4:8) type D2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed by Engineer in Charge.
M & L for RCC M-25 nominal mix using 20 mm graded aggregates as in foundations, including rafts, footings, foundation beams; plinth beams , mass concrete complete all as specified and as directed by Engineer in Charge.
M & L for RCC M-25 nominal mix using 20 mm graded aggregates as in column ,pillars,piers,posts and struts complete all as specified and as directed by Engineer in Charge.
M & L for RCC M-25 nominal mix using 20 mm graded aggregates as in lintel and roof beams complete all as specified and as directed by Engineer in Charge.
M & L for RCC M-25 nominal mix using 20 mm graded aggregates as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by Engineer in Charge.
M & L for form work to footings, foundations, base of columns, raft beams, plinth beams, etc and similar rough finished surface of concrete complete all as specified and as directed by Engineer in Charge.
M & L for form work to sides of pillars,posts ,struts,columns,rough finished surface of concrete complete all as specified and as directed by Engineer in Charge.
M & L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, complete all as specified and as directed by Engineer in Charge.
M & L For Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed by Engineer in Charge.
M& L for MS bars TMT 10 mm dia and over ,cut to length,bent to shape requirred including cranking ,bending,spiraling for hooping for column, hooking ends and binding with and including MS wire annealed not less than 0.9 mm dia complete all as specified and directed.
M& L for MS TMT bars 5mm dia and over upto and including 10mm dia , in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S & F Framed work such as grills, gratings, with ornamental & intricate design for windows, ladder, Spiral staircase etc., with ends of bar shoulder &/or riveted, or forged into spikes; framed guard bars, incl hinges, framed balusters, walk ways; railings & similar work conforming to Fe 290 GDE -E-165 complete all as specified and as directed by Engineer in Charge.
S & F Welded steel wire mesh/fabric including cutting in size and welded to steel frame etc with weight per square metre not less than 4.0 Kg complete all as specified and as directed by Engineer in Charge.
M&L for applying two coats synthetic enamel paint over a coat of red oxide/zinc chrome primer including preparation of new steel/iron surfaces exc 10cm in width or girth complete all as specified and as directed by Engineer in Charge.
M&L for applying One coat high glass synthetic enamel paint including preparation of old steel/iron surfaces exc 10cm in width or girth all as specified and as directed by Engineer-in-charge.
Demolition of brick masonry, built in cement mortar of any description all as specified and as directed by Engineer-in-Charge.
M&L for Cutting out bricks, forming toothing for and bonding new into old work including inserting new brick into the old wall and built in CM 1:6 complete all as specified and as directed.
M&L for brick work with sub class 'B' old size bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6, complete all as specified and as directed by Engr-in-charge.
M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in coping, Roof padding, benching, bed block, window cills etc including necessary form work complete all as specified and as directed by Engr-in-charge.
Dismantling of floor, hearth or wall tiling including cement morter bedding (but not backing), removing serviceable tiles to the stores and rubbish off the premises complete all as specified and as directed by Engineer in Charge.
M&L for 25mm thick PCC 1:2:4 Type B0 (12.5mm Graded Stone Aggregate), as in sub floor Floors, etc. complete all as specified and as directed by Engineer in Charge.
M&L for Non–Skid Ceramic Coloured Tiles, size 300x300x7 or 400X400X7 to 8mm, Laid on floor, over and including 15mm thick screed bed in cement mortar 1:4 Laid and Jointed in Neat Cement Slurry and pointed in White Cement with pigment to match the shade of the Tiles, complete all as specified and as directed by Engineer in Charge.
M&L for Glazed Ceramic Coloured Tiles of size 300X450X7mm to 8mm, set on vertical surfaces such as Skirting, Dado, etc, over and including 10mm thick screed bed in cement mortar 1:3 Set and Jointed in Neat Cement Slurry and Pointed in White Cement with pigment to match the shade of the Tiles, complete all as specified and as directed by Engineer in Charge.
S & F for 10mm thick vitrified tiles double charge tiles light shade 10mm thick (square/rectangular) polished, area of each tile n.exc. 0.36 sqm, in floor and skirting etc., set and jointed in neat cement slurry over 15mm thick screed bed in CM 1:4 and pointed in white cement with pigment to match the colour of tiles for laying floor fineshes complete all as specified and as directed by Engineer in Charge.
M&L for 8 to 10mm thick Matt Finish Ceramic joint free Coloured Tiles, of size 600x600mm, Laid on Floor over and including 15mm thick Screed bed in CM 1:4, Laid and Jointed in Neat Cement Slurry and Pointed in White Cement with pigment to match the shade of the Tiles complete all as specified and as directed by Engineer in Charge.
M&L for 8 to 10 mm thick ceramic joint free Coloured Tiles, of size 600x100/150mm, on vertical surface/Skirting over and including 10mm thick rencering in CM 1:4 Laid and Jointed in Neat Cement Slurry and Pointed in white cement with pigment to match the shade of the Tiles, complete all as specified and as directed by Engineer in Charge.
M&L for 20mm thick prepolished Black (Zed Black) granite slab laid with 15 mm thick CM 1:4 bedding over 40mm thick Cuddappa stone horizontal and vertical support including cutting and pnning in wall and floor as in plateform etc including fixing and jointing with grey cement slurry and pointed in white cement with pigment to match the shade of granite stone including Moulding/rounding and polishing all as specified and directed by Engr-in-charge.
Dismantling of wall and ceiling boards (Fibre, pulp, insulation, wooden etc.) or insulation board / slabs any thickness incl cover fillets complete all as specified and as directed by Engineer in Charge.
S&F for 5mm thick Plain colour PVC wall lining consisting of PVC sheet inclusive of Solvant Cement and fixing at site on PVC frame complete all as specified and as directed by Engineer in Charge.
S&F 35x5mm PVC Fillet PVC Sheet fixed for wall panelling complete all as specified and as directed by Engineer in Charge.
M&L for suspended false ceiling consisting of suitable GI sections of ‘T’ Angle & FI as per Std engineering practices with ‘E’ board classic ceiling boards 4mm thick in grid of 0.60x0.60mtr including cutting holes and making good holes for main joints, suspending with 4mm dia GI wire to roof slab, roof trusses, purlins & rafters etc and complete all as specified and as directed by Engineer in Charge.
M&L for Anti termite treating of soil along the external wall using chemical CHLOROPYRIPHOS 20EC emulsion @ 2.25 Ltr/Rm including digging and plugging of holes complete all as specified and as directed by Engineer in Charge.
M&L for Anti termite treating the soil under floor and plith protection using chemical CHLOROPYRIPHOS 20EC emulsion @ 5.00 Ltr/Sqm of emulsion on earth surface complete all as specified and as directed by Engineer in Charge.
M&L for 75 mm thick in PCC 1:3:6 type C-2 using 40mm graded aggregate as in Plinth protection including 6x10mm grove in every 3Mtr including bitumen mastic filling in joints complete all as specified and directed by Engr-in-Charge.
S&F in repairs 5mm thick plain sheet Glass, ordinary quality, glazing as in window fixed with Bead/oil Putty, not exc. 0.50 Sqm in Each Pane and fixed with clips etc, complete all as specified and directed by Engr-in-Charge.
S&F in repairs 4mm thick figured Glass, ordinary quality, glazing as in window fixed with Bead/oil Putty, not exc. 0.50 Sqm in Each Pane and fixed with clips etc, complete all as specified and directed by Engr-in-Charge.
Dismantling of old unserviceable rolling Shutter/Steel Gate of area n exc 25 Sqm each of any description including making good surface and removing from site complete all as specified and directed by Engr-in-Charge.
S&F for MS Collepsible gate top hung consisting of channel pickets, pivoted flat bars, top and bottom runner, handles etc including necessary locking arrangement and fixing in position and securing runners with holdfasts and brackets complete all as specified and directed by Engr-in-Charge.
Taking down door/window frame with shutter of area exc 1.50 but n exc 4.0 Sqm each and removing to store complete all as specified and directed by Engr-in-Charge.
S&F aluminium colour powder coated (shade or tint as directed by GE) window frame with two track using Jindal or equivalent section No 20832 (92x31.75x1.50mm) fixed with thrust bolt in walls by drilling and sliding shutter of section No 20844 (40x18x1.29mm) or equivalent section for glass including 4.00mm thick tinted glass fixed with rubber beading and bushes complete in both the track fixed with screw and aluminium beading complete all as specified and as directed.
S&F Aluminium colour powder coated (shade or tint as directed by GE) window/Ventilator frame of using Jindal or equivalent section No 20032 (61.85x31.75x1.50mm) fixed with thrust bolt in walls by drilling for top hung shutter using suitable section with 4mm thick tinted glass with necessary friction hinges and locking arrangement complete all as specified and as directed.
S&F aluminium colour powder coated door Frame and shutter single or double leaf with partly glazed/pre laminated board exterior quality party glazed panels fabricated including aluminium powder coated beading, rubber and packing materials and shall be drilling in existing wall and thrust bolt suitable size complete comprising the following:- (a) Aluminium colour powder coated door frame section 101.60x44.45x1.93 mm. (b) Aluminium colour powder coated vertical section in shutter 85x44.45x2 mm. (c) Aluminium colour powder coated Top Rail & style shutter section 95.25x44.45x2.00 mm. (d) Aluminium colour powder coated handle 02 Nos in each shutter 200 mm long. (e) Aluminium colour a powder coated Tower bolt 02 Nos in each shutter 150 mm long. (f) Aluminium colour powder coated middle lock rail/bottom rail section 150x44.45x2.00mm cat No.20002. Make-Jindal (g) Six lever mortice lock brass Make : Godrej/Classic on in each door. (h) 12 mm thick particular board (pre laminated both face) exterior grade ISI Marked (j) Tinted glass/Plain glass 5mm thick Make : Saint gobain/ modiguard. (h) Floor spring , Make Sandu Note: If ground requirement for full glass or full Panel contractor should provide as per direction of Engr-in-Charge.
S&F aluminium colour powder coated Frame and Partition for Cubicals with glazed/pre laminated particle board panels fabricated including aluminium powder coated beading, rubber gasket and packing materials and shall be drilling in existing wall and thrust bolt suitable size complete comprising the following :- (a) Aluminium colour powder coated frame section 101.60x44.45x1.93 mm fixed as per spd, Make-Jindal (b)12 mm thick prelaminated particle board (pre laminated both face) exterior grade ISI Marked . (c) Tinted glass/Plain glass 5mm thick Make : Saint gobain/modigaurd. Note: If ground requirement for full glass or full Prelaminated particle board Panel contractor should provide as per direction of Engr-in-Charge.
S&F 18mm thick plywood (12 ply) fixed with 0.9mm thick decorated laminate both side pasted with adhesive as in cupboard, Cup board partition, shutter and shelves etc. fixed with screws, complete including Necessary Lipping, Cove Hinges, magnet Cacher and handle for Shutter fixed with screw for cup boards etc complete all as specified and as directed.
Removal of debris/malwa to a distance exc 10 Km but n exc 15.00 Km out side MD land and depositing where complete all as specified and directed by Engr-in-Charge.
M&L for Complete removal of existing old treatment from wall and ceiling by scraping down with steel brush/steel patty preparing old plastered surface of walls with wall care putty 2 to 3mm thick and applying two coats distemper oil emulsion By Auto Roller over a coat of primer complete all as specified and directed by Engr-in-Charge.
S&F Sheet metal eoclosure for DBs when MCBs to be used triple pole neutral 4 way, double door 415 V rating including taking out unserviceable DBs by carefully disconnecting the existing connections, complete all as specified and as directed by Engr-in-charge.
M&L for cutting holes into or through brick walls built in brick walls, built in cement mortar or cement lime mortar and stone walls built in lime mortar or walls of lime mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B1 as required n exc. 150 Sq. Cm in supreficial area all as specified and as directed.
Taking down copper/aluminium point wiring (light points) complete, including fixtures and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for the above items should be made as per conditions seperately) and making good disturbed surfaces of walls. floors, etc. complete all as directed .
Taking down unserviceable/burnt, copper/aluminium submain wiring complete, including conduits of any kind, and removing materials to store for keeping in safe custody or for taking credit (credit for the above items should be made as per conditions seperately) and making good disturbed surfaces of walls. floors, etc. complete all as directed.
M&L for point wiring with 1.5 Sqmm (nominal area) PVC insulated and unsheathed single core FRLSH copper cable 1100 volts grade with multistranded copper conductor in and including cutting of chases to lay PVC rigid concealed conduit (heavy grade), exposed to surface wherever required including conduit as specified, and making good to surface by using CM 1:3, and using of wall finish paint to match the existing surface, as specified including all fittings and conduit accessories also, complete including modular metal flush box, modular white cover plate with frame and PVC insulated and unsheathed FRLSH single core multistranded copper conductor cable of size 1.5 Sqmm green in colour as earth continuity conductor connected to common earth dolly for one light/fan point controlled by one, one way switch complete all as specified and as directed by Engr-in-charge.
All as per item No 77 hereinbefore but for 5/6Amp Socket outlet on independent board.
All as per item No 77 hereinbefore but for 5/6Amp Socket outlet on same board.
All as per item No 77 hereinbefore but for Power point 16/20 Amps wiring using 4 sqmm copper conductor PVC insulated and unsheathed cable with copper cable as earth wire 2.5 mm 2 PVC Insulated un sheathed multistranded complete all as specified and as directed by Engr-in-Charge.
M&L for wiring sub main wiring concealed along with earth wire with the following size of FRLSH PVC insulated and unsheathed multistranded copper conductor single core cables in concealed through 25 mm rigid non metalic PVC conduit heavy duty with 4 x 6 sqmm + 2 x 6 sqmm earth wire complete all as specified and directed by Engineer-in-Charge. including cutting chesses pinning in making good to facing and pointing in cement morter1:3 to the ends or cutting chesses for conceled point wiring and making good distrubed surface complete cutting not exceeding 4 cm girth and 4 cm width . Note:- Two run of cable and one length of PVC conduit with earth conductor shall be measured as a one length complete all as specified and as directed by Engr-in-Charge.
All as per item No 81 hereinbefore but with 4 x 4 sqmm + 2 x 4 sqmm earth wire.
All as per item No 81 hereinbefore but with 2 x 4 sqmm + 1 x 4 sqmm earth wire.
M&L for recess/ surface mounting LED flat panel 2'X2' light fitting, fabricated out of CRCA sheet steel housing duly powder coated with high efficient LEDs & glare free full opal diffuser, IP20 complete with all accessories internally pre-wired and including conneting up with three core twisted flexible copper conductor cable with suitable size.Make: Halonix, CAT No: HLFPR22-02-36 CW-R or equivalent of Bajaj/Philips/CG)
M&L for energy LED corrossion resistant batten with polycarbonate housing and opal diffuser, IP 65 complete with suitable lamp, 40 Watt and all accessories internally pre-wired and including conneting up with three core twisted flexible copper conductor cable of suitable size.(Make: Halonix, CAT No: HLB-04-40-CW or equivalent of Bajaj/Philips/CG)
M&L LED box channel luminarie made out of CRCA sheet suitable for 1 x 20 Watt LED T8 including LED T8 tube, IP 20 complete all as specified and as directed. (Make: Halonix, CAT No: HLIB-05-118 LED-1S or equivalent of Bajaj/Philips/CG)
S&F Air circulator fans 230 Volts single phase oscilating 450 mm sweep suitable for wall mounting complete all as specified and as directed by Engr-in-charge. (HSN Code-8414, Make-Havells/Bajaj or equivalent).
S&F exhaust fans AC single phase 230/240 V of size 450 mm sweep with louver (HSN Code-8414,Make-Havells/Bajaj or equivalent) complete all as specified and as directed by Engr-in-charge.
S&F fans ceiling complete with electronic type regulator and accessories 230V, 1200 mm sweep, BEE 5 star rated (Model/Description-Zinger50,Make-Standard/Havells or equivalent) complete all as specified and as directed by Engr-in-charge.
S&F Switch modular 10 Amps, single pole one way complete all as specified and directed by Engineer-in-Charge.
S&F Switch modular 16 Amps, single pole one way complete all as specified and directed by Engineer-in-Charge.
S&F modular type socket outlet shuttered modular type two module 3/5 pin, 6 Amps multtipurpose complete all as specified and directed by Engineer-in-Charge.
S&F modular type socket outlet shuttered modular type two module 3/5 pin, 16 Amps multtipurpose complete all as specified and directed by Engineer-in-Charge.
S&F ceiling rose,3 phase PVC polycarbonate complete all as specified and directed by Engr-in-Charge.
S&F industrial wall mounted plug socket suitable for IP 67 degree of protection 16 Amps rating 3P+N+E (CAT no-507862,Make-Legrand) complete all as specified and as directed by Engr-in-charge.
S&F RCBO for earth leakage, overload and short circuit protection, 32 A, four pole, 30 mA complete all as specified and as directed by Engr-in-charge.
S&F MCB, SP, Breaking capacity min 10KA,'C' curve 230V, 6 to 32 Amps complete all as specified and as directed by Engr-in-charge.
Note The amount of Rs 65,005/- against Schedule of Credit on Page No 143 shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance
M/S Parshant Associates
JAIPAL AND BROTHERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .