Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.2 LAccepted-AOC MES CHOWPATHY PO HASIMARA DISTT JALPAIGURI PIN 735215 WB | HASIMARA | JALPAIGURI | WB | 735215 | L1 | Accepted-AOC BEING LI BIDDER | |
| 2 | L2₹20.8 L+₹63,697 (3.16%)Rejected-Finance | L2 | Rejected-Finance REJECTED DUE TO HIGH BID VALUE | |
| 3 | L3₹21.2 L+₹1.1 L (5.32%)Rejected-Finance | L3 | Rejected-Finance REJECTED DUE TO HIGH BID VALUE | |
| 4 | L4₹21.3 L+₹1.2 L (5.90%)Rejected-Finance | L4 | Rejected-Finance REJECTED DUE TO HIGH BID VALUE | |
| 5 | L5₹21.4 L+₹1.3 L (6.38%)Rejected-Finance | L5 | Rejected-Finance REJECTED DUE TO HIGH BID VALUE |
Tender Value
₹21 L
EMD Value
₹42,000
Closing Date
26 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) HASIMARA
GE (AF) HASIMARA PO HASIMARA DIST ALIPURDUAR PIN 735215
REPAIR TO JOINERY AND ALLIED WORKS AT KV AREA AND REPAIR / REPLACEMENT OF STREET LIGHT AT LIVING OUT, OMQ AND KV AREA UNDER GE (AF) HASIMARA
2020_MES_350386_1
C/8401/20-21/E8
Open Tender
Civil Works
Item Rate
210 days
GE (AF) HASIMARA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) HASIMARA
₹42,000
Yes
8 Jul 2020
6 Jun 2020
27 Jun 2020
6 Jun 2020
26 Jun 2020
20 Jun 2020
60 days
Amount
SCHEDULE 'A' PART-I Taking down chowkats or frame, n.exc 1.5 Sqm each with shutters (without taking off shutter from the frame) complete all as specified and directed.
Taking down chowkats or frames, exe 1.5 but n.exc. 4 Sqm in each with shutter (without taking off shutter from the frame) complete all as specified and directed.
Taking down shutters of any description exc 1 Sqm but n. exc 2 Sqm each complete all as specified and directed.
S & F Well seasoned 2nd class hard wood plain, solid, straight chowkat and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed.
M & L for Pressed steel frames 105mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed.
M & L for Pressed steel frames 125mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed.
M & L for Providing cement concrete 1:3:6 type C-0 (using 12.5 mm graded stone aggregate) for filling hollow portion, pressed steel frames, etc complete all as specified and directed.
S & F 30 mm thick, Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S & F 25 mm thick, Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides as in cup board shutter complete all as specified and directed.
S & F 35 mm thick, 2nd class hardwood, factory made, Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
S & F 35 mm thick, factory made, glazed/skeleton shutters with second class hard wood,open rebated and prepared to receive glass, gauze, etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass, etc complete as specified and directed . Sizes of members of shutters as specified in SSR Part I, Section -8, clause 8.24 (a).
M & L for Preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer complete all as specified and directed.
M & L for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zine chrome primer complete all as specified and directed.
S & F solid PVC door frames of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed.
S & F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded, plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, as per specification and drawing and as directed.
S & F 100 mm long, stainless steel butt hinges fixed with stainless steel hinge pin etc complete all as specified and directed.
S & F 200 mm long, Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed.
S & F 200 mm long, Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed.
S & F 150 mm size, extruded aluminium handles, fabricated type, anodised complete all as specified and directed.
S & F 125 mm size, Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S & F Aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clipes of sheet, cast or extruded sections and fixing bolts of extruded sections or cast aluminium alloy, length of bolt of 300 mm complete all as specified and directed.
M & L for plain cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate) for embedding holdfast, bed block, cills, etc including necessary form work complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed.
S & F 3 mm thick, sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
S & F 3 mm thick, figured glass, pin headed type, in square n.exc 0.5 Sqm in each pane complete all as specified and as directed.
S & F 300 mm long, mild steel, ordinary rat tail rod pattern springs incuding roller and roller plate complete all as specifed and directed.
S & F in repairs, 300 mm long, mild steel, ordinary rat tail rod pattern springs incuding roller and roller plate complete all as specifed and directed.
S & F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S & F in repair Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water complete all as specified and directed
M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 5 mm thick in cement mortor 1:3 on concrete surfaces as in ceilings (sunshed, chajja etc) and finishing surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 15 mm thick in two coats (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with integral water proofing compound with weight of cement in top layer as per manufacturer's instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item).
Supply only integral water proofing compound (ISI marked) complete all as specified and directed.
M & L for preparing newly plastered surfaces of internal walls, etc and applying two coats of distemper oil emulsion over a coat of alkali resistant primer complete all as specified and directed.
M & L for Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
M & L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, in floors etc, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for glazed, coloured, ceramic, tiles of size (350mm x 250 mm/450mm x 350mm/300mmx450mm) x 6 to 7 mm thick, on vertical surfaces such as skirting, dados etc, including 10 mm thick bedding in cement mortor 1:4 and set & jointed in neat cement slurry & pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
S & F in repair Steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S & F in repair Steel ventilator, fixed type with glazing bar complete all as specified and directed.
Taking down steel window/ventilators shutter of any size and description and refixed in the same opening after minor repairs/welding and necessary minor accessories as required complete all as directed. (Note: Box type hinge, stay, handle etc shall be measured and paid sperately as supply only)
Supply only mild steel handle for steel window for left/right shutter complete all as specified and directed.
Supply only mild steel peg stay including nuts & bolts etc suitable for steel window and ventilator complete all as specified and directed.
Supply only mild steel box type hinge suitable for steel window and ventilator complete all as specified and directed.
S & F in repairs, Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers, etc as in curtain rail complete all as specified and directed.
S & F in repairs, Aluminium (Die cast) body door Closer hydraulically regulated, designation No 3, universal type, suitable for door shutter of 851 to 1000 mm in width and of weight between 61 to 80 Kg complete all as specified and directed.
S & F 15 mm thick, second class hard wood boarding, clean sawn with butt joints and fixed with nail as in shelves; Partitions and shelves of built-in cupboards, almirahs, book cases, toilet boxes, racks, pelmets and similar work and fixed as In repairs to replace old and or decayed boarding in patches including cutting out old, piecing, heading joints, etc.complete all as specified and directed.
S & F mild steel bands, straps, supports or stays of rain water, ventilating pipes including bolts, hooks (stay) for large gates, hook and pintel hinges, clamps, hold fasts, wall ties,flat iron fillets for securing wire mesh, wind tie, fan hook and similar work including necessary drilling bolting or riveting etc conforming to Fe – 290 Gde E – 165 complete all as specified and as directed.
M & L for preparing surfaces of wood and wood based materials, steel and iron works, new or old of any description and girth treating ends of posts, back of chowkats etc, area tarred exc 0.1 Sqm but n.exc 0.5 Sqm each with tar or coal tar black paint complete all as specified and as directed.
M & L for preparing surfaces of wood and wood based materials, steel and iron works, new or old of any description and girth treating small articles such as holdfasts etc area n.exc 0.10 Sqm each with tar or coal tar black paint complete all as specified and as directed.
M & L for Sanding newly tarred or painted surfaces with clean sharp sand complete all as specified and directed.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation, etc and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed.
Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
Supply and laying well burnt bricks, sub class 'B' bricks laid breath wise across the length of cable in trenches for protection of UG cables complete all as specified and directed.
M & L for Sand cushioning with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and directed. (Note: Thickness after punning down shall be measured for payment)
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 core including taking out old one complete all as specified and directed. (Note: Excvation and earth work shall be measured and paid seperately)
All as per item No 59 above but cross sectional area 70 Sqmm, 3.5 core complete ditto.
All as per item No 59 above but cross sectional area 50 Sqmm, 3.5 core complete ditto.
All as per item No 59 above but cross sectional area 35 Sqmm, 3.5 core complete ditto.
M & L for 80 mm bore, steel tubes, galvanised, light grade with all fittings and MS clamps, nuts & bolts etc for protection of cable laid in loor/trenches/drain/road crossing on pole or pillar as required including taking up or down existing pipe and including making good disturbed surfaces wherever required as specified and directed.
All as per serial item No. 63 above but 50 mm bore of pipe complete ditto
M & L for boring of horizontally holes by manual method under road below 1 metre from the road surface and dia of hole not exc 100mm without damaging the exsting road, getting out and disposal of excavated soil, etc to a distance not exc. 50 meter from the site of work complete all as directed by Engineer in charge.
Dismantling of existing unserviceable outdoor type feeder pillar box and removing from site of work and supply, install, commissioning and testing cubical type LT distribution pillar, 415 Volts, 50 Hz AC supply, three phase and neutral, outdoor type (KIOSK) with apron of size 400mmx350mmx300mm, factory made fabricated out of out of MS sheet 1.6mm thick with suitable size of MS channel supports and with suitable size of angle iron legs for grouting, duly powder coated internally and externally with approved shade, rubber gasket, hinged front and back openable doors with proper locking arrangements, dust and vermin proof complete including suitable size of lugs, glands and making connections comprising of the following items complete all as specified and directed:- (a) Aluminium bus bar suitable for 200 Amps capacity for 3 phase and 200 Amps for netral supported on insulators. (b) Necessary excavation and earth work, PCC type C-2 concrete of suitable size over PCC lean concrete type D-2 as required for platform to house the panel complete all as directed
Dismantling/taking down old aluminium steel reinforced (ACSR) conductor of any size from HT/LT overhead line including all jumper etc and keeping serviceable materials in safe custody for reuse in the work complete all as specified and directed.
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside serviceable materials for re-use with in 50m and removing unserviceable materials from site of work incluidng demolition of PCC foundation and taking out base plate etc complete all as directed by the Engr-in-Charge
Dismantling of insulators of any type from LT poles of any size and type and setting aside complete all as specified and directed.
M & L Earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with galvanised earth strip of size 25x4mm dia by means of bolts, nuts, check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers,necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing complete inclduing taking down old one as specified and as directed.
All as per serial item No. 71 above but of suitable size of distribution pillar to accomodate following fittings and fixtures complete and ditto:- (a) MCCB, 4 pole, 125Amps, 16KA, incoming -01 No. (Make: Legrand Cat No. 4200 16 or equivelant as per list of manufacturers) (b) MCCB, 4 pole, 100Amps, 16KA, incoming -01 No. (Make: Legrand Cat No. 4200 15 or equivelant as per list of manufacturers) (c) MCCB, 4 pole, 40Amps, 16KA, outgoing - 03 Nos (Make: Legrand Cat No. 4200 12 or equivelant as per list of manufacturers) (d) MCB, SPN, 63Amps, 10KA - 02 Nos (Make: Legrand Cat No. 4086 20 or equivelant as per list of manufacturers) (e) Aluminium bus bar suitable for 300 Amps capacity supported on insulators - 04 Nos (f) Necessary excavation and earth work, PCC type C-2 concrete of suitable size over PCC lean concrete type D-2 as required for platform to house the panel complete all as directed
All as per serial item No. 71 above but of suitable size of distribution pillar to accomodate following fittings and fixtures complete and ditto:- (a) MCCB, 4 pole, 100Amps, 16KA, incoming -01 No. (Make: Legrand Cat No. 4200 15 or equivelant as per list of manufacturers) (b) MCCB, 4 pole, 40Amps, 16KA, outgoing - 03 Nos (Make: Legrand Cat No. 4200 12 or equivelant as per list of manufacturers) (c) MCB, SPN, 63Amps, 10KA - 02 Nos (Make: Legrand Cat No. 4086 20 or equivelant as per list of manufacturers) (d) Aluminium bus bar suitable for 300 Amps capacity supported on insulators - 04 Nos (e) Necessary excavation and earth work, PCC type C-2 concrete of suitable size over PCC lean concrete type D-2 as required for platform to house the panel complete all as directed
M & L for Preparation of old painted surface above the planting depth/PCC coping of steel tubular LT pole upto 11.00 metre long including MS clamps, cable protection pipe, bracket fitted with steet light fittings etc by scraping with steel wire brush and applying two coats of aluminium paint to external surface of poles, MS cross arms, MS clamp, cable protection pipe etc to give even shade including Zebra colour of painting upto 2.1 m height from the top of coping/bottom of pole as per site condition and numbering of poles complete all as specified and as directed by the Engr-in-Charge. (Note : Zebra colour will be applied by synthetic enamel paint of black/yellow colour as approved in alternate layer of 30 cm height of each layer).
S & F in repairs, three core twisted, flexible copper conductor wire of size 1.00 Sqmm for connection complete all as specified and directed.
M & L for making hole by gas flame of appropriate size in street light steel pole (02 Nos per pole) for passing the connection wire etc from junction box to street light complete all as specified and directed.
M & L for disconnecting burnt end or portion of UG cable, removing the cable from loop including necessary excavation and earth work, relaying and re-connecting the cable by removing burnt protion of cable and preparing fresh terminals for cable of cross sectional area 10 Sqmm 2 core to 95 Sqmm 3.5 core of LT cable to pole main switch etc complete all as specified and as directed by the Engr-in-Charge.
M/S BISHAL ENTERPRISES
CONSTRUCTION SHELTER
T. P. ANIL KUMAR
B L SHARMA
M/S. KUMAR CONSTRUCTION CO.
M/S SARDAR MAL NAHATA
M/S RATHIN ENTERPRISES
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .