Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.0 LAccepted-AOC | L1 | Accepted-AOC REASONABLE | |
| 2 | L2₹9.7 L+₹44,014.14 (4.76%)Rejected-Finance | L2 | Rejected-Finance HIGH RATE | |
| 3 | L3₹11.2 L+₹2.0 L (21.6%)Rejected-Finance | L3 | Rejected-Finance HIGH RATE | |
| 4 | L4₹11.8 L+₹2.5 L (27.4%)Rejected-Finance WARD NO 07 WARD NO 07 THANA PARA NALHATI BIRBHUM WEST BENGAL 731243 | BIRBHUM | WEST BENGAL | 731243 | L4 | Rejected-Finance HIGH RATE |
Tender Value
Refer Docs
EMD Value
₹18,000
Closing Date
3 Aug 2021, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I AF SINGARSI
AGE I AF SINGARSI
Repair Maint of LT Panel LT UG Cables including connected works at Technical and Domestic Area of AF Stn Singarsi Under AGE I AF Singarsi
2021_MES_452303_2
C/8516/E8
Open Tender
Civil Works
Item Rate
180 days
AGE I AF SINGARSI
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Yes
AGE I AF SINGARSI
₹18,000
Yes
6 Aug 2021
20 Jul 2021
4 Aug 2021
20 Jul 2021
3 Aug 2021
21 Jul 2021
30 days
Amount
Excavation in trenches not exceeding 1.5 M wide and not exceeding 1.5 M in depth and getting out in Hard/dense or any other type of soil for taking up or laying of cable all as specified and directed.
All as per item No 1 above but depth exe. 1.5 mtr but not exe 3 mtr complete all as directed.
All as per item No 1 above but hard surfaces such as in road cutting/ hard standing etc including making good disturbed surfaces to match with original complete all as directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms.
Removing excavated material not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above starting point.
Supply and laying new dry river sand laid in trenches 8cm below the cable and 15cm above the cable and punned to 18cm as cable cushioning and covering all as directed. Note:- Punned quntity will be measured paid at this item.
Pruning/Cutting of tree branches of any size beyond 2 Mtr from over head lines (LT/HT) /around LT street light pole etc including depositing same to a distance as directed by Engr-in-Charge (Note :- Distance shall be measured where tree branches comes on over head lines 50 RM of each Span).
S & F pin type insulator procelain, vitreous white, brown or green including galvanised mild steel spindle, two Nos galvanised iron washer and one galvanised iron nut 100 mm height, 65 mm dia for 1100 volts grade complete all as specified.
S & F in repacement of cross arms, bracings, supports, clamps, back plate fabricated from structural steel sections such as channels, angles , flat iron including 16mm dia bolts, nuts, washers, welding, bending, cold or hot drilling holes for bolts/insulators in any shape and size as directed and inclusive of one priming coat of red oxide zinc chrome, one under coat and one finishing coat of aluminium paint including dismantling of old unserviceable cross arms complete including taking up of old UNSV cross arms complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of ACSR conductor for LT OH Line aluminium conductor steel reinforced size as per existing including dismantling of old unserviceable ACSR conductor including taking up of old UNSV ACSR conductor complete all as specified and directed by Engr-in-Charge.
M & L required for restreching / tightening of LT over head line all 3 phases & nutrals (Conductor) of any type/GI earth wire including opening out binding wire from pin/shackle/disc insulator and rebinding the conductor with insulator with 14 SWG binding wire complete all as directed by Engr-in-Charge.
S & F in replacement of danger notice plate of 1.6mm thick mild steel sheet vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with M S Clamps, bolt and nut approved size for LT 20x15cm size including taking out old unserviceable danger notice plate complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement stay assy set complete comprising of galvanized steel bow 14mm dia 40 cm long, stay rod 16mm/20mm dia 1.8 mtr long galvanized thimble compleete inluding taking down old UNSV stay assy complete all as specified and directed by Engineer-in-Charge. all as specified and shown in electrical plate No 1 of SSR part 1 Note: Excavation, PCC stay clamps and loop type insulator shall be measured and paid for separtely under respective items. Note:- Stay clamp, loop type insulator, excavation and concrete measured paid separtely.
M&L for PCC 1:2:4 type C1using 20mm stone aggregate for coping of pole complete all as directed
M&L for PCC 1:3:6 type C2 using 40mm stone aggregate for stay assembly & pole PCC complete all as directed
M&L in replacement for Earthing complete with galvanised steel earth plate electrode of size 600x600x6mm thick burried in a pit to a depth of 2.25mtrs below ground level with top edge of earth plate at a depth of not less than 1.50 meters below ground level, earth plate packed on all sides with charcol dust mixed with salt to a thickness of 15cm,.Connected with earthing lead of 32mmx6mm strip galvanised iron, watering pipe 20mm dia light grade and water filling funnel and mess complete all as shown in plate No 4 of MES schedule part II to the earthing test point, Including PCC Work complete including protection pipe 40 mm dia light grade all as specified and directed by Engr-in-Charge. (Note :- The earth strip/lead up to 7.5 mm is deemed to be included quoted rates.)
Supply and laying in replacement of earthing strip GI 32x6 mm from earth test point to Electrical equipment including taking up of old UNSV earthing strip complete all as specified and directed by Engr-in-Charge.
Tesing of earth resistance of earth pit for lightning protection with adequite equipments , inspection the conductors, joint and parts of the system,continuity testing across conductor , result obtained during test note down on register as directed by the Engineer -in-Charge Note : 1.Test terminal and strips will me measured and paid separetlely 2. : Testing of electric protection system as above for one building irrespective of Nos of earthing consisting One Job .
Supply and fixing test point block of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head etc.
M/L in replacement of Earthing complete with GI earth plate 60x60cmx6mm thick electrode and 4mm dia GI wire as earthing lead burried directly in ground ( earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level. connected to GI wire earth lead 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 and incl earth work,PCC pit and RCC cover,watering pipe 20 mm dia light grade,funnel,wire mesh,protection pipe 15 mm dia light grade , charcoal dust and salt etc and connected to earthing test point including taking up of old UNSV earthing complete all as specified and directed by Engr-in-Charge.
M & L for painting of LT panel Surfaces of any description after scrapping the old painted surfaces completd with Synthetic enamel paint as directed by Engr-in-Charge
M&L for painting of steel tublar pole 9 Mtr long, LT any type vertical complete with cross arms with one coat of aluminium paint after preparation on of surfaces of pole/cross arms including painting of black & yellow strip of 30cm upto 1.5Mtr above coping and marking of MES No and directed by Engr-in-charge.
Supply Laying, jointing, testing and commissioning or fixing in replacement of cable in wall or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty ) with aluminium conductor, 1100 volts, grade of cross sectional area as under including taking up of old UNSV XLPE cable complete all as specified and directed by Engr-in-Charge. :- (a) 1 0 sqmm 4 core
16 sqmm 4.0 core
35 sqmm 3.5 core
50 sqmm 3.5 core
70 sqmm 3.5 core
Supply and fixing CRCA sheet of 1.6 mm thickness including welding & cutting arrangement for existing door of panels /sub station shutter complete with suitable hinges and locking arrangements as directed by Engr- in -charge .
S & F in replacement of GI tubing light grade 80mm nominal bore for cable protection fixed with clamps of M.S. Flat iron 25x3mm, GI nuts, bolts and washers to poles/under floor/under roads/alongwith walls including two coats of aluminium paint over a coat of red oxide primer on clamps complete including taking up of old UNSV GI tubing complete all as specified and directed by Engr-in-Charge.
- ditto- same as per item No 26 here-in-before but for size 50mm bore.
Supply and laying in replacement of brick well burnt locally available sub class 'B' laid over sand cushioning for cable protection in trenches width of brick perpendicullar to the length of cable including taking up of old UNSV bricks complete all as specified and directed by Engr-in-Charge.
M/S ASHA ENTERPRISE
LALAN SHARMA
M/S New Builders Corporation
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .