| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.3 LAccepted-AOC FLAT NO S 2 SHRI CHINTAMANI S NO 1 1148 MAHAJAN PETH MODEL COLONY SHIVAJI NAGAR PUNE 411016 | PUNE | PUNE | MAHARASHTRA | 411016 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹18.9 L+₹3.6 L (23.4%)Rejected-Finance | L2 | Rejected-Finance Greater than lowest |
Tender Value
Refer Docs
EMD Value
₹33,000
Closing Date
12 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL MANISH KUMAR
GE (P) NDA Khadakwasla NDA Khadakwasla Pune
CONSTR OF GUARD AT NEW LONG RANGE AT NDA KHADAKWASLA
2023_MES_616278_3
8123
Open Tender
Civil Works
Works
180 days
GE (P) NDA Khadakwasla
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE (P) NDA Khadakwasla
₹33,000
Yes
25 Jan 2024
21 Nov 2023
18 Dec 2023
21 Nov 2023
12 Dec 2023
28 Nov 2023
Amount
Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out soft/loose soil complete all as specified and directed by Engineer-incharge.
Excavating in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc 10 sqm on plan and not exc 1.5 m in depth and getting out soft/loose soil complete all as specified and directed by Engineer-incharge.
Excavating in trenches, not exc 1.5 m wide and n exc 1.5 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc 10 sqm on plan and not exc 1.5 m in depth and getting out hard dense soil complete all as specified and directed by Engineer-incharge.
Excavating in trenches, n exc 1.5 m wide and exc 1.5 m in depth but not exc 3.0 mtr depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc 10 sqm on plan and not exc 1.5 m in depth and getting out hard dense soil complete all as specified and directed by Engineer-incharge.
M & L for excavation in trenches n. exc.1.5 m wide and not exceeding 1.5m in depth for laying of pipes /cables in Soft/Disintegrated rock and getting out including trimming the sides and forming botton surface to required level complete all as specified and as directed by Engineer-in-Charge.
M&L for Returning, filling in any type of Soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick all as specified and as directed by Engineer-in-Charge.
M&L for Returning, filling in approved Soft/Disintegrated rock, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick all as specified and as directed by Engineer-in-Charge.
Removal of surplus excavated soil to a distance n.exc.50m and depositing where directed at a level n.exc.1.5 m above the starting point for soft/loose soil all as specified and as directed by Engineer-in-Charge.
Removal of surplus excavated Soft rock to a distance n.exc.50m and depositing where directed at a level n.exc.1.5 m above the starting point for hard dense soil all as specified and as directed by Engineer-in-Charge.
M&L for Anti-Termite Treatment to treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed by Engineer-incharge.
M&L for Anti-Termite Treatment to treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed by Engineer-incharge.
M&L for Anti-Termite Treatment to treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed by Engineer-incharge.
M&L for Anti-Termite Treatment to treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed by Engineer-incharge.
M&L for Anti-Termite Treatment to the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed by Engineer-incharge.
M&L plain cement concrete type D-2 (1:4:8) (40mm Graded stone agregate) as in foundations, filling and mass-concrete complete all as specified and directed by Engineer-incharge.
M&L plain cement concrete type C-2 (1:3:6) (40mm Graded stone agregate) as in foundations, filling and mass-concrete complete all as specified and directed by Engineer-incharge.
M&L for 75 mm thick plain cement concrete type C-2 (1:3:6) (40mm Graded stone agregate) in sub base floor etc complete all as specified and directed by Engineer-incharge.
M&L for RCC M-25 Design Mix (using 20mm graded stone aggregate) in foundation including rafts, footings, foundation ,plinth beam under reamed piles and mass concrete complete all as specified and directed by Engineer-incharge.
Use and waste of form work to sides of concrete foundation , footings , plinth beam and like etc curved surface finished with even and fair surfaces of concrete complete all as specified and directed by Engineer-incharge.
M&L RCC M-25 Design Mix (using 20mm graded stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified and directed by Engineer-incharge.
Use and waste of Formwork to side of pillars, columns etc and similar work.; square, rectangular or polygonal shape of concrete for rough finished surfaces of concrete complete all as specified and directed by Engineer-incharge.
M&L RCC M-25 Design Mix (using 20mm graded stone aggregate) as in beams, Cantilevers, bressummers and lintels complete all as specified and directed by Engineer-incharge.
Use and waste of Formwork to side and soffits of floor beam, roof beams lintels etc and similar work, flat surface of concrete for rough finished surfaces of concrete complete all as specified and directed by Engineer-incharge.
M&L RCC M-25 Design Mix (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balcones, canopies, deck slabs and in shelves etc complete all as specified and directed by Engineer-incharge.
Use and waste of Formwork to soffits of suspended slabs such as roof slabs etc and similar work, flat surface of concrete for rough finished surfaces of concrete complete all as specified and directed by Engineer-incharge.
M&L RCC M-25 Design Mix (using 20mm graded stone aggregate) as in Chajjas complete all as specified and directed by Engineer-incharge.
Use and waste of Formwork to chajjas, throughs etc and similar work, flat surface of concrete for rough finished surfaces of concrete complete all as specified and directed by Engineer-incharge.
Use and waste of Formwork to edges of concrete flats, chajja , treads, breaks in floors,window cills, concrete railings openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work for rough finished surfaces of concrete exc 5cm but n exc 10cm wide complete all as specified and directed by Engineer-incharge.
Use and waste of Formwork to edges of concreteflats, treads, breaks in floors,window cills, concrete railings openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, horizontalor sloping and similarwork for rough finished surfaces of concreteexc 10cm but n exc 20cm wide complete all as specified and directed by Engineer-incharge.
M&L for Damp Proof Course 40 mm thick to horizontal or vertical surfaces including necessary formwork in Cement Cocrete 1:2:4 type B-0 complete all as specified and directed by Engineer-incharge.
M&L for applying evenly a tack coat of blown type bitumen 85/25 at the rate of 1.5 Kg/Sqm and binding with clean dry sand @0.05 Cum.per Sqm complete all as specified and directed by Engineer-incharge.
M&L for Moorum / red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick spread, levelled and rammed including watering complete all as specified and directed by Engineer-incharge.
M&L Hardcore of broken stone gauge not exc. 63 mm, deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface etc complete all as directed
M&L 60 mm thickness M-35 Grade factory made rubber moulded precast concrete interlocking paver block in grey cement with pigment and of approved size and shape and confirming to IS 15658-2006, with true line, level watered and mechanically compacted including 25mm thick sand filling below interlocking blocks etc complete all as specified and directed by Engineer-incharge.
M&L for 30mm thick flooring in Cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) complete all as specified and directed by Engineer-incharge.
M & L for providing mild steel TMT bars 10mm dia & over cut to length bent to shape required including cranking bending etc & binding with MS wire (annealed) not less than 0.90mm dia complete all as specified and directed by Engineer-incharge.
M & L for providing mild steel TMT bars 5mm dia and over up to and including 10mm dia in stirrups, spacers and binders complete all as specified and directed by Engineer-incharge.
M & L for providing mild steel round bars 10mm dia & over cut to length bent to shape required including cranking bending etc work as in rungs of garde Fe-410-W (Gde.E-250) quality-A complete all as specified and directed by Engineer-incharge.
M&L for old size Fly ash brick masonry straight or curved on plan exc 6m mean radius built in CM (1:6) complete all as specified and directed by Engineer-incharge.
M&L for old size Fly ash brick masonry straight or curved on plan to any radius built in CM (1:4) complete all as specified and directed by Engineer-incharge.
M&L for Brickwork with old size fly ash bricks in one brick thick honey-comb walling masonry built in CM (1:4) complete all as specified and directed by Engineer-incharge.
M&L for Brickwork with old size fly ash bricks in straight or curved on plan to any radius in half brick walls built in CM (1:4) complete all as specified and directed.
M&L 75mm thick plain Cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as sub base complete all as specified and directed by Engineer-incharge.
M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:6 surfaces, finished fair and even complete all as specified and directed by Engineer-incharge.
M&L for Rendering 15mm thick other than fair faces of brick work or concrete surfaces in CM 1:6 surfaces, finished fair and even complete all as specified and directed by Engineer-incharge.
M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:3 surfaces, finished fair and even in ceiling complete all as specified and directed by Engineer-incharge.
M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 surfaces, finished fair and even complete all as specified and directed by Engineer-incharge.
M&L for Rendering 15mm thick other than fair faces of brick work or concrete surfaces in CM 1:4 surfaces, finished fair and even complete all as specified and directed by Engineer-incharge.
Forming V grooves in plaster n exc 10mm deep and n exc 10mm on face complete all as specified and directed by Engineer-incharge.
M&L for hand cut kota stone slab 20-25mm thick as in floor etc set and jointed in neat cement slurry and pointed in white cement or coloured cement to match the slabs including 20 mm thick screed bed of CM (1:6) and rubbing and mirror polishing complete all as specified and directed by Engineer-incharge.
M&L for hand cut kota stone slab 20-25mm thick as riser of steps, skirting, dado and pillar etc set and jointed in neat cement slurry and pointed in white cement or coloured cement to match the slabs including 10 mm thick backing coat of CM (1:4) and rubbing and mirror polishing complete all as specified and directed by Engineer-incharge.
M&L for non skid ceramic coloured tiles of size 300x300X7 mm to 8mm thick in foors etc set and jointed in neat cement slurry and pointed in white cement or coloured cement to match the tiles including over 15 mm thick screed bed of CM (1:6) complete all as specified and directed by Engineer-incharge.
M&L for glazed ceramic coloured tiles of size 450x350x7mm thick as in vertical surface, set and jointed in neat cement slurry and pointed in white cement or coloured cement to match the tiles including over 10 mm thick backing coat of CM (1:4) complete all as specified and directed by Engineer-incharge.
S&F for vitreous china water closet (pedestal pattern) of size 580x440mm white in colour with integral foot rest including PVC valveless, syphonic action type flushing cistern of capacity 10 ltr, 32mm bore PVC flush pipe, 450mm long PVC connection pipe etc complete all as specified and directed by Engineer-incharge.
S&F for vitreous china wash basin (flat back or angle back type) of size 550x400mm including cutting for and pinning in ends of brackets or erecting stand, 32mm dia brass chromium plated waste coupling and 32mm dia brass chromium plated bottle trap, 450mm long PVC connection pipe etc complete all as specified and directed by Engineer-incharge.
M&L for 20 mm thick granite (of any type) work (table rubbed and polished) as in wash basin platform complete all as specified and directed by Engineer-incharge.
M&L for Machine cut cudappah stone slab 20 to 25mm thick as in wash basin platform and vertical support etc complete all as specified and directed by Engineer-incharge.
Labour only for chamferring and rounding the straight cut edges of stone slab such as in steps, cooking platform and other similar situations complete all as specified and directed by Engineer-incharge.
M&L for providing bib taps cast copper alloy chromium plated fancy type with crutch or butter fly handle screwed down for Iron pipe or for brass fancy for CP brass fancy type 15mm dia complete all as specified and directed by Engineer-incharge.
M&L for providing angular stop cock cast copper alloy fancy type screwed down high pressure with cruntch or butterfly handle, screwed both ends for iron pipe or for union and fixed for 15mm bore of pipe with long shunk and cup complete all as specified and directed by Engineer-incharge.
S&F 15 mm bore pillar taps, cast copper alloy, chromium plated fancy type screwed down high pressure with long screwed shanks and fly nuts complete all as specified and directed by Engineer-incharge.
S&F for 75mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints, laid in trenches or in floor etc using synthetic rubber adhesive cement solvent complete all as specified and directed by Engineer-incharge.
S&F for 75mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints, fixed to wall etc using synthetic rubber adhesive cement solvent complete all as specified and directed by Engineer-incharge.
S&F for 110mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints fixed to wall etc using synthetic rubber adhesive cement solvent and including clips wall hooks/clamps, wooden plugs etc complete all as specified and directed by Engineer-incharge.
S&F for 110mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints, laid in trenches or in floor etc using synthetic rubber adhesive cement solvent complete all as specified and directed by Engineer-incharge.
S&F for 110mm dia PVC (SWR) bends any radius with access door complete all as specified and directed by Engineer-incharge.
S&F for 75mm dia PVC (SWR) bends any radius with access door complete all as specified and directed by Engineer-incharge.
S&F for 75mm dia PVC (SWR) bends any radius complete all as specified and directed by Engineer-incharge.
S&F for 110mm dia PVC (SWR) bends any radius complete all as specified and directed by Engineer-incharge.
S&F for 75mm outle dia of PVC (SWR) floor trap, plain with grating including complete all as specified and directed by Engineer-incharge.
S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed by Engineer-incharge.
M & L rendering 5mm thick on ceilings concrete surface in cement mortar 1:3 finished fair and even without using extra cement complete all as specified and directed by Engineer-incharge.
M&L for preparation newly plastered surfase of ceiling and applying three coats of white wash etc complete all as specified and directed by Engineer-incharge.
M&L for preparation newly plastered surface of wall and applying two coats of OBD including 3mm thick wall care putty complete all as specified and directed by Engineer-incharge.
M&L Preparation of new plastered surfaces and applying two coats of cement base paint on wall complete all as specified and directed by Engineer-incharge.
S&F 1000 ltrs capacity rotational moulded polyethylene three layer white in colour water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed by Engineer-incharge.
S&F 20 mm ball brass valves, high pressure, with polythelene float and flynut complete screwed for iron pipe or brass ferrule complete all as specified and directed by Engineer-incharge.
S&F 20 mm dia gate valves cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer-incharge.
S&F 20 mm bore tube medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-incharge.
M&L for cutting chases exc 10cm but not exc 20 cm girth in concrete fly ash brick walls for consealed water tubing etc pinning in making goods to facings where required and ponting in cement mortar (1:3) to ends or edge complete all as specified and directed by Engineer-incharge.
S&F 15 mm bore tube medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-incharge.
M&L for Providing precast reinforced cement concrete type B1, 1:2:4 20 mm graded stone aggregate for cover slabs etc and setting in mortar complete with joints to match set in CM (1:6) complete all as specified and directed by Engineer-incharge.
S&F Solid PVC door frame of size 50mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS Square tube, fixed in opening complete all as specified and directed by Engineer-incharge.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.,supplying and fixing in frame at site as per specification and drawing complete all as specified and directed by Engineer-incharge.
S&F butt hinges 100mm mild steel, medium weight, cold rolled complete all as specified and directed by Engineer-incharge.
S&F for pressed steel frames for doors with of size 125x60mm with one or more rebates including necessary fixing lugs, hinges lock strike plate etc complete all as specified and directed by Engineer-incharge.
S&F for pressed steel door frames of siz 105x60mm with one or more rebate including necessary fixing lugs, hings lock strike plate etc complete all as specified and directed by Engineer-incharge.
M&L for P.C.C. ( 1:3:6) type C-0 (using 12.5mm thick graded stone aggregate) as in filling of pressed steel door frame complete all as specified and directed by Engineer-incharge.
S& F for 40mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed by Engineer-incharge.
S& F for 35mm thick IInd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I (2009), Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed by Engineer-incharge.
S&F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed by Engineer-incharge.
M&L for preparation of new wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat pink primer complete all as specified and directed by Engineer-incharge.
S&F extruded aluminium alloy handle fabricated type annodised size of handle 125 mm complete all as specified and directed by Engineer-incharge.
S&F extruded MS handle fabricated type annodised size of handle 125 mm complete all as specified and directed by Engineer-incharge.
S&F for 200 mm long mild steel barrel tower bolt , stove enamelled black ,with bright bolt and fixed complete all as specified and directed by Engineer-incharge.
S&F for 200 mm long aluminium anodised,barrel tower bolt , stove enamelled black ,with bright bolt and fixed complete all as specified and directed by Engineer-incharge.
S&F for Mild steel sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolt and sliding bolts of extruded section of 300mm long complete all as specified and directed by Engineer-incharge.
S&F for aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolt and sliding bolts of extruded section of 250mm long complete all as specified and directed by Engineer-incharge.
S&F 300mm helical spring ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed by Engineer-incharge.
S&F Butt hinges, 100 mm extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and directed by Engineer-incharge.
S&F Butt hinges,100 mm medium weight, cold rolled mild steel, and fixed complete all as specified and directed by Engineer-incharge.
S&F Floor door stopper of Overall length of cover plate 140mm of aluminium alloy body and tongue, anodised,with hard drawn steel spring, fixed in floor complete all as specified and directed by Engineer-incharge.
S&F for Mild steel sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolt and sliding bolts of extruded section of 250mm long complete all as specified and directed by Engineer-incharge.
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded etc complete all as specified and directed by Engineer-incharge.
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete but without glazing bars, dovetailed or welded etc complete all as specified and directed by Engineer-incharge.
S&F for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290. Gde-E-165 complete all as specified and directed by Engineer-incharge.
S&F Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed by Engineer-incharge.
Preparation of new or previously untreated steel surface of any description over 10 cm in width or girth, not otherwise described, applying two coats of synthetic enamel paint over a coat zinc primer complete all as specified and directed by Engineer-incharge.
Supply only 3.0mm thick pin headed type glass not exc 0.5 sqm in each pane complete all as specified and directed by Engineer-incharge.
M&L for 15 mm thick screed bed in two layers CM (1:4) with WPT compound having smooth fair finished on concrete or brick walls complete all as specified and directed by Engineer-incharge. (Note: WPC wil be measured and paid separately)
Supply only Integral water proofing compound complete all as specified and directed by Engineer-incharge.
M & L water proofing treatment to RCC roof slab, walls, chhajjas etc, shall be carried out as specified below and as directed by Engineer-in-Charge including following . (a) Preparing plastered surfaces of roof slab, walls, chhajjas etc, by brooming with broom sweeping free from dirt dust etc & evenly applying a coat of approved bitumnous primer @ 1.2 kg/Sqm of area complete all as specified. (b) Laying APP polymer modified approved membrane, non woven, polyester, weighing not less than 3.5 kg/Sqm and 3mm thick reinforced with polyester non wove fabric (wt not less than 160 gms/sqm) laid over primed surface with laps & overlaps as specified & joints sealed and applied complete by torch application method all as specified & directed by Engineer Incharge. Carrying out test by flooding water for 24 hrs for leakagge & seepages and rectifying the same to the entire satisfaction of GE. (c) Finally applying applying one coat of aluminum paint including preparation of surface.
M & L plain cement concrete type C-2 (1:3:6) (40mm Graded stone aggregate) in 75mm thick plinth protection and finishing the cement concrete surface even and smooth using extra cement etc complete all as specified and directed by Engineer-incharge.
M&L for RCC drain pipe 150mm dia class NP-2 with collars laid in trenches with cement joint & tested complete all as specified and directed by Engineer-incharge.
M & L Providing cement concrete in surface channels and drains type B2 (1:2:4) (using 40mm graded stone aggregate) complete all as specified and directed by Engineer-incharge.
M & L Providing cement concrete in copings type B1 (1:2:4) (using 20mm graded stone aggregate) complete all as specified and directed by Engineer-incharge.
M&L for 150mm bore of pipe Cement Concrete bed type C-2 (1:3:6) to drain pipes including packing under, and haunching against sides of pipes after they are laid and tested. complete all as specified and directed by Engineer-incharge.
M&L Loose filling with Broken brick aggregates of gauge 40 to 80 mm in soakage pits, soakage wells complete all as specified and directed by Engineer-incharge.
M&L Brushing neat cement slurry with 3.0kg of cement per sq. metre complete all as specified and directed by Engineer-incharge.
M & L for Point wiring with proper colour coding complete with and including PVC insulated, unsheathed, flexible bright annealed multi stranded copper conductor single core flame retardant low smoke (FRLS) cables 1.5 Sqmm (22/0.30 mm) 1100 volts grade drawn through in and including heavy grade, rigid non-metallic PVC conduits 25 mm or higher dia as required at site, totally concealed in walls / floors /ceiling and surfaces on trusses by means of saddles & clips etc including all conduit accessories / fittings / junction boxes / inspection covers etc of heavy grade, ISI marked and modularb metal boxes, totally concealed in walls with modular plate and frame fixed flush with wall surface by means of brass screws and sunk/cup washers, for mounting of switches, sockets fan regulators etc; including 1.5 Sqmm (22/0.30 mm) 1100 V grade PVC insulated FRLS, unsheathed flexible, multi stranded, copper conductor cable (green colour) as continuous earthwire connected to metallic bodies of luminaires/fans etc; at one end and to common earth dolly at other end, complete all as specified and directed by Engineer-incharge for following :-
One light/Fan/Exhaust Fan point controlled by one, one way switch 6 Amps 240 Volts.
One 3 pin 6 Amp Socket outlet point on Same board including earth wire as per description given above and connected to common earth and earth terminals.
One 3 pin 6 Amp Socket outlet point on Independent board including earth wire as per description given above and connected to common earth and earth terminals.
All as per description of serial item No 121 here -in -before but for 3-pin socket out let 15 Amps on independent board with 2.5 Sqmm Multi std.copper conductor PVC insulated cable 1100 volts grade with continous 2.5Sqmm earth wire.
S&F socket 2-in-1 3pin 6 Amps flush type (ISI Marked) controlled by one way switch complete all as specified and as directed by Engr-in-charge.
S&F Switch piano flush type 6 Amps single pole one way complete all as specified and directed by Engineer-incharge.
S&F socket 2 in 1, 5/15 Amp flush type (ISI Marked) universal controlled by one way switch complete all as specified and as directed by Engr-in-charge.
S&F Switch piano flush type 16 Amps single pole one way complete all as specified and directed by Engineer-incharge.
S&F ceiling rose surface type PVC 50 mm dia 3 terminals including PVC mounting block complete all as specified and directed by Engineer-incharge.
S&F of ultra slim liner LED lighting fixture Mirror light with extruded aluminium heat shrink, environmental friendly, energy efficient ready to use pack of capacity 11 Watt LED, accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-incharge.
S&F of decorative ultra slim liner LED lighting fixture with extruded aluminium heat shrink, environmental friendly, energy efficient ready to use pack of capacity 20 Watt LED, accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-incharge.
S&F polycarbonate angle holder retrofit type suitable for LED bulb of B-22 base including 01 nos 18/20 watt LED Bulb complete all as specified and directed by Engineer-incharge.
S&F Distribution board sheet metal enclosure double door, factory made fixed flush with wall inside niches for mounting MCBs with front openable cover SPN 8 way, 240 volts with 100 Amp busbar complete all as specified and as directed by Engr -In-Charge .
S&F MCB SP 6 to 32 Amps 240V,10 KA breaking capacity , C curve with IP 20 protected complete including connection with copper /aluminium cable lugs suitable size for incoming and outgoing cable wires complete all as specified and directed by Engineer-incharge.
S&F MCB SPN 32 Amps, 240V,10 KA breaking capacity , C curve with IP 20 protected terminals all as specified including complete connection with copper /aluminium cable lugs with suitable size for incoming and outgoing complete all as specified and directed by Engineer-incharge.
M & L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to galvnised steel earthing lead wire 4 mm dia, by means of bolts, nuts & checknuts and washers etc; GI pipe 15 mm dia medium grade pipe for protection of G.I earth lead wire, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg)/transformer/LT kiosk/HT lightening arrestors etc. including GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1: 2 : 4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with G.I 20 mm dia light grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of soil / strata & testing on completion including fill up the earth pit with soil for best result and removal of excavated material from the site complete all as specified and directed by Engineer-incharge. (Note :- Earth protection pipe & earthing lead wire upto and including 7.5 m length is deemed included in unit rate quoted by the contractor).
S&F for exhaust fan, steel body, single phase, heavy duty, Metal frame,300 mm sweep, including fixing of GI air louvers 16 SWG and mounting frame in the round hole cutting in the wall, by means of rugged bolts, nuts and washers etc, including three core copper conductor flexible cord of 0.5 Sqmm cross sectional area of required length from ceiling rose to the porcelain connector block of the exhaust fan complete all as specified and directed by Engineer-incharge. Note:- The cost of Exhaust Fan GI air Louvers 16 SWG is deemed included in the unit quoted rate by the contractor.
S&F ceiling fan with the fan hook/box, 1200 mm (48") sweep, Min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor(BLDC) and connecting up complete with and including Fan Regulator step type , three core copper conductor flexible cord of 0.5 Sqmm cross sectional area, of required length, rod less than 16mm dia from ceiling rose to procelain connector block of the fan, complete all as specified and directed by Engineer-incharge.
M&L for sub main wiring with two single core PVC insulated FRLS cables with stranded copper conductors 4 Sqmm , 1100 Volts grade drawn through PVC conduit with saddles double lock type ISI marked not less than 19 mm with all fitting & other accessories and copper cable 4 sqmm continuous earth wire complete all as specified and directed (Two runs of 04Sqmm cable with 01run of 04Sqmm earth wire along with PVC conduit shall be measured as one RM)complete all as specified and directed by Engineer-incharge.
S&F Plexo box Power Unit 4 module including one 20Amps MCB SP and 15Amp Switch & socket with Plug top of 230V, 50 HZ, IP-55 & IK-09 Class-II, weatherproof cabinets, door and cabinet fully reversible, removable chassis and faceplates, including weatherproof glands, rails qty-1 Nos. complete all as specified and directed by Engineer-incharge.
Supply, laying, testing and connecting of LT UG cables of size 4 core 10 Sqmm, 1100 Volt grade, XLPE insulated and PVC sheathed, armoured, with multi stranded aluminium conductor, heavy duty confirming to IS - 1554 part-I, including cable glands, cable lugs in LT panel/ MDB in bldg etc including M&L for all jointing/connecting material as required, cables laid in trenches/ducts/under plinth floors passing through pipes etc, 4 core 10 Sqmm fixed on wall complete all as specified and directed by Engineer-incharge.
M&L for proving burnt clay fly ash bricks modular type,sub- class 'B' designation 75 for protection of under ground electric cables, laid flat in trenches, abutting each other perpendicular to the direction of cable complete all as specified and directed by Engineer-incharge.
M&L for sand cushioning to electric cable with clean dry river sand 8 cm thick layer before laying of cable in trenches and 15 cm thick after the cable is laid in trenches/cable ducts for cable protection complete all as specified and directed by Engineer-incharge.
S&F for GI tubing (ISI Marked), light grade 40 mm bore for cable protection with all necessary fittings as required, laid in trenches, under road/floors or on electric poles complete all as specified and directed by Engineer-incharge.
Road cutting upto 25cm depth and width 45 cm for laying of GI protection pipe of suitable size for cable and making good road surface with PCC (1:2:4) Type B-1 (Course graded aggregate) after laying of pipe to match existing complete all as specified and directed by Engineer-incharge.
Supply and installation of LED Street Light fitting pressure die cast aluminium housing, heat resistant glass, IP 65 ptotection, better optics for uniform distribution of 35 Watts capacity suitable for mounting on street light bracket including street light bracket & testing on completion complete all as specified and directed by Engineer-incharge.
Supply and fix 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity 16KA complete all as specified and directed by Engineer-incharge.
Supply, laying, jointing and testing Galvanised steel water tubings, medium grade laid in trenches in any lengths with screwed and socket joints, together with all galvanised steel fittings such as sockets, elbows, bends, tees reducers, unions caps plugs, nipples, short pieces etc complete all as specified and directed by Engineer-incharge. following sizes :-
40 mm bore
25 mm bore
Supply, fix and testing GM gate/globe valves conforming to IS 778 with iron wheel head screwed both ends for u/m size complete all as specified and directed by Engr-in-charge.
40 mm bore
25 mm bore
M&L for taking up cast iron mains cutting in site reducing to required length, jointing, including flange, socket, materials and laying/testing complete of 80 mm bore complete all as specified and directed by Engineer-incharge.
M&L for taking up existing steel tubings, cutting in site reducing/lengthening to required length, screwing, jointing, including materials required for jointing like bends,union, reducer, tees, elbow etc and laying/testing complete up to 40 mm bore complete all as specified and directed by Engineer-incharge.
PAWAN B SHINDE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .