Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.3 LAccepted-Finance 4 1 70 1 ROAD NO 11 SNEHAPURI NACHARAM HYDERABAD 500 076 | HYDERABAD | MEDCHAL MALKAJGIRI | TELANGANA | 500076 | ₹21.3 L | L1 | Accepted-Finance being the lowest tenderer |
| 2 | L2₹22.1 L+₹77,000 (3.61%)Rejected-Finance 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | ₹22.1 L+₹77,000 (3.61%) | L2 | Rejected-Finance not being the lowest tenderer |
| 3 | L3₹23.3 L+₹2.0 L (9.45%)Rejected-Finance 1001 63 SHALIMAR GARDEN ISMAILGANJ NEAR INDIRA NAGAR SECTOR 08 CROSSING LUCKNOW 226016 | LUCKNOW | UTTAR PRADESH | 226016 | ₹23.3 L+₹2.0 L (9.45%) | L3 | Rejected-Finance not being the lowest tenderer |
| 4 | L4₹24.5 L+₹3.2 L (15.0%)Rejected-Finance 53 13 A OUTER CIRCULAR ROAD KILPAUK GARDEN COLONY CHENNAI 600 010 | CHENNAI | CHENNAI | TAMIL NADU | 600010 | ₹24.5 L+₹3.2 L (15.0%) | L4 | Rejected-Finance not being the lowest tenderer |
| 5 | L5₹26.0 L+₹4.7 L (22.0%)Rejected-Finance 2 755 ELAIYATHAMMAN KOIL MAIN ROAD BHARADHI NAGAR PTMS IAF POST AVADI CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | ₹26.0 L+₹4.7 L (22.0%) | L5 | Rejected-Finance not being the lowest tenderer |
| Sl No | Description | Qty | Unit | M/s.Sai Agency L4 | G HARI ELECTRICALS L5 | SIRITEL SYSTEMS PRIVATE LIMITED L1 | EVEREST ENGINEERING WORKS L2 | RK ENTERPRISES L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply & fixing cast iron sluice valve PN 1.6 conforming to IS 14846-2000 with stainless steel spindle, iron hand wheel & cap suitable for 80mm bore pipe with flanged ends, any pattern including nuts, bolts, rubber gasket, wheel etc. including taking down unserviceable sluice valve complete all as specified and directed. | 5 | Each | 8,000 ₹40,000 | 15,000 ₹75,000 | 10,000 ₹50,000 | 9,500 ₹47,500 | 7,000 ₹35,000 Lowest |
| 2.00 | Supply & fixing cast iron sluice valve PN 1.6 conforming to IS 14846-2000 with stainless steel spindle, iron hand wheel & cap suitable for 100mm bore pipe with flanged ends, any pattern including nuts, bolts, rubber gasket, wheel etc. including taking down unserviceable sluice valve complete all as specified and directed. | 2 | Each | 8,500 ₹17,000 Lowest | 18,000 ₹36,000 | 15,500 ₹31,000 | 12,000 ₹24,000 | 9,000 ₹18,000 |
| 3.00 | Supply & fixing cast iron sluice valve PN 1.6 conforming to IS 14846-2000 with stainless steel spindle, iron hand wheel & cap suitable for 150mm bore pipe with flanged ends, any pattern including nuts, bolts, rubber gasket, wheel etc. including taking down unserviceable sluice valve complete all as specified and directed. | 4 | Each | 9,500 ₹38,000 Lowest | 20,000 ₹80,000 | 20,000 ₹80,000 | 16,000 ₹64,000 | 12,000 ₹48,000 |
| 4.00 | Surface dressing not exceeding 15 cm deep and getting out in soft/loose soil including cutting of grass vegetation aroound pump house and removing excavated material(soil) and rubbish to out side MD land all as specified and as directed by the Engr-in -Charge | 12,500 | SQM | 7.1 ₹88,750 | 9 ₹1,12,500 | 5 ₹62,500 Lowest | 15 ₹1,87,500 | 15 ₹1,87,500 |
| 5.00 | Chemical analysis testing of water samples (Raw and Treated ) for physical examination and chemical exmaination full test from TWADA/ Govt. approved laboratory including sample collection, endorsing date and time, transportation, provision of sample container, etc all as directed by Engineer-in-Charge. | 75 | Each | 1,700 ₹1,27,500 | 3,200 ₹2,40,000 | 1,000 ₹75,000 Lowest | 3,500 ₹2,62,500 | 2,500 ₹1,87,500 |
| 6.00 | M&L for seven-stage cleaning and sterilization of under ground sump of capacity not exceeding 200000 litres, of any description and at any location. The work includes thorough cleaning and sterilization of water tanks through bacteriological treatment using TERBAC-G5 / Inchor-5 / NB-10 / TERBAC-G-65 / Inoxi-60 / NB-69 and Ultra Violet (UV) Ray treatment.
Make: Rays Cleantech / Inus Watertech / Satya Enterprise
Location: 5 wells,-1 nos, 7 wells-1 nos, camp are PH-2 Nos, GOC resi-2 nos, kmre PH -1 nos, IGOE-1 nosThe seven stages are as detailed below:
(a) First stage: Draining out the water completely using the exit valve or a high-capacity dewatering system.
(b) Second stage: Cleaning all algae formation inside the tank by using TERBAC-G10 / Inoxi-60 / NB-69, a laboratory-tested branded chemical, including manual scrubbing of tank walls.
(c) Third stage: Fresh water cleaning using a high-speed jet pump.
(d) Fourth stage: First bacterial screening and disinfection using TERBAC-G5 / Inchor-5 / NB-10, a Government-laboratory-certified branded halogen compound.
(e) Fifth stage: Cleaning of the tank floor using an industrial vacuum cleaner.
(f) The sixth stage is the second bacteriological screening and sterilization process, carried out using ultraviolet (UV) rays inside the tank to eliminate all suspended bacteria.(g) The seventh stage of cleaning and the third bacteriological screening involves sterilizing the floor of the water tank using a laboratory-certified, branded strong oxidizing agent, such as
TERBAC-G65 / Inoxi-60 / NB-69.
NOTE: Contractor will submit the Govt Laboratory test sertificate of TERBAC-GS/INCHOR-5/NB-10
(i) On completion of cleaning of tank, date of cleaning to be marked/written clearly on tank surface by properly using stencil paper in an accessible location with letters or figure not exc 20cm high viz “TANK CLEANED ON ---”
(ii) Before cleaning of tank prior intimation (at least 24 hours before ) shall be given to the occupent.
(iii)All cleaning and sterilization staff shall be covered under accidental insurance. iv)The outlet pipe of the OHT shall be plugged before cleaning to avoid the entry of scales. The same shall be reconnected after completion of cleaning. (v)The quoted rate shall be deemed inclusive of this provision.
(vi)The sterilization team shall comprise at least 30% trained personnel, holding a minimum 3-month certification in water tank sterilization. (vii)The contractor shall be responsible for rectification of any complaints arising during cleaning, such as:No water in tank Overflow due to broken float valve,Blockages. All such rectifications shall be included in the quoted rate. | 8 | Each | 44,000 ₹3,52,000 | 46,000 ₹3,68,000 | 26,000 ₹2,08,000 | 10,000 ₹80,000 Lowest | 40,000 ₹3,20,000 |
| 7.00 | All as per item No.6 here in before but underground water storage sump of capacity 1,50,000 Ltrs, Location-camp 1 ph-2 nos,PGOE-1 nos, Golf -1 nos, SOL-1 nos,Nandanam-1 nos. | 6 | Each Job | 35,000 ₹2,10,000 | 38,000 ₹2,28,000 | 20,000 ₹1,20,000 | 7,500 ₹45,000 Lowest | 30,000 ₹1,80,000 |
| 8.00 | All as per item No.6 here in before but underground water storage sump of capacity 1,00,000 Ltrs complete all as specified and directed. Location-KMRE-2 nos, Camp 1 Ph-1 nos, SOL-1 nos, 7 wells-1 nos, PGOE-2 nos and DB area-1 nos | 8 | Each Job | 30,005 ₹2,40,040 | 25,000 ₹2,00,000 | 16,000 ₹1,28,000 | 6,000 ₹48,000 Lowest | 20,000 ₹1,60,000 |
| 9.00 | All as per item No.6 here in before but underground water storage sump of capacity 75,000 Ltrs Location-Camp area Ph-02 nos, Golf-1 nos, 7 wells- 1 nos,SOL-1 nos, PGOE-1 nos, MES IB-1 nos, COS resi-1 nos | 8 | Each Job | 25,001 ₹2,00,008 | 23,000 ₹1,84,000 | 14,000 ₹1,12,000 | 5,000 ₹40,000 Lowest | 20,000 ₹1,60,000 |
| 10.00 | All as per item No. 6 here in before but underground water storage sump of capacity 50,000 Ltrs complete all as specified and directed. Location- DB area -1 nos, SOL-1 nos, 16 block-1 nos, 13 Block-1 nos, Camp area P-1 nos, 7 wells -1 nos, PGOE-1 nos, IGOE -1 nos | 8 | Each Job | 20,501 ₹1,64,008 | 13,000 ₹1,04,000 | 12,000 ₹96,000 | 4,000 ₹32,000 Lowest | 15,000 ₹1,20,000 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
20 Jul 2026, 6:55 pmClosed
GE Chennai
GE Chennai 600 09
REPAIRS MAINT WATER SUPPLY SYSTEM CLEANING OF SUMPS AND OH RESERVOIR AND CONNECTED WORKS UNDER GE CHENNAI
2026_MES_773794_1
8961/E8
Open Tender
Civil Works
Item Rate
273 days
GE Chennai
As per tender
7 documents required · 7 mandatory
₹500
GE Chennai
₹60,000
Yes
10 Sept 2026
22 Jun 2026
22 Jul 2026
22 Jun 2026
20 Jul 2026
6 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply & fixing cast iron sluice valve PN 1.6 conforming to IS 14846-2000 with stainless steel spindle, iron hand wheel & cap suitable for 80mm bore pipe with flanged ends, any pattern including nuts, bolts, rubber gasket, wheel etc. including taking down unserviceable sluice valve complete all as specified and directed. | 5 | Each | - | - |
| 2 | Supply & fixing cast iron sluice valve PN 1.6 conforming to IS 14846-2000 with stainless steel spindle, iron hand wheel & cap suitable for 100mm bore pipe with flanged ends, any pattern including nuts, bolts, rubber gasket, wheel etc. including taking down unserviceable sluice valve complete all as specified and directed. | 2 | Each | - | - |
| 3 | Supply & fixing cast iron sluice valve PN 1.6 conforming to IS 14846-2000 with stainless steel spindle, iron hand wheel & cap suitable for 150mm bore pipe with flanged ends, any pattern including nuts, bolts, rubber gasket, wheel etc. including taking down unserviceable sluice valve complete all as specified and directed. | 4 | Each | - | - |
| 4 | Surface dressing not exceeding 15 cm deep and getting out in soft/loose soil including cutting of grass vegetation aroound pump house and removing excavated material(soil) and rubbish to out side MD land all as specified and as directed by the Engr-in -Charge | 12,500 | SQM | - | - |
| 5 | Chemical analysis testing of water samples (Raw and Treated ) for physical examination and chemical exmaination full test from TWADA/ Govt. approved laboratory including sample collection, endorsing date and time, transportation, provision of sample container, etc all as directed by Engineer-in-Charge. | 75 | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.61 MB
Tender8961.pdf
Tender Documents • 0.76 MB
BOQ_866432.xls
BOQ • 0.31 MB
8961_OTHER_Corrigendum.pdf
PDF • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .