GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
EXTERNAL REPAIRS INCLUDING ROOF TREATMENT AND PERIODICAL SERVICES TO THE BUILDINGS IN BAIRAGARH UNDER GE BHOPAL
2026_MES_779630_1
8638/E8
Open Tender
Civil Works
Item Rate
180 days
BHOPAL
PLEASE REFER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE BHOPAL
₹90,000
Yes
18 Jul 2026
18 Jul 2026
10 Aug 2026
18 Jul 2026
8 Aug 2026
1 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.1 | S&F in repairs PVC (SWR) pipes 110mm dia single socketed, in any length with rubber ring joints laid in trenches , floors or fixed in walls complete all as specified and directed. | 850 | RM | - | - |
| 2 | S&F PVC (SWR) 110mm bore bends any radious complete. | 60 | Each | - | - |
| 3 | S&F PVC (SWR) 110mm bore single T any radious complete. | 30 | Each | - | - |
| 4 | Dismantling of timber scantling in fillets, rails, posts, rafters, purlins etc 40 sqcm and over in section, in any posotion for unframed works complete all as specified. | 0.75 | Cum | - | - |
| 5 | S&F steel work in tubular/angle trusses including special shaped washers, purlins, rafters, posts etc complete all as specified and directed. | 1,250 | Kg | - | - |
| 6 | M&L Pre Galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick AZ-150 of an colour having tensil strength of 550/MPA as in roof covering/cladding to wall/ ridge,fixed with self tapping screw/L type or J type cranked hook bolts including dismantling asbestos cement (corrugated, semi corrugated etc) sheets in roof covering. complete all as specified and directed. | 650 | Sqm | - | - |
| 7 | M&L Pre Galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick AZ-150 of an colour having tensil strength of 550/MPA as in roof covering/cladding to wall/ ridge,fixed with self tapping screw/L type or J type cranked hook bolts including dismantling asbestos cement (corrugated, semi corrugated etc) sheets in roof covering, complete all as specified and directed. | 35 | Sqm | - | - |
| 8 | M&L for preparation of old existing roof surface by washing rubbing down removing oil grease and vegitation etc. and applying ready made branded chemical treatment of approved OEM to roof/ exterior wall/ parapet wall/ chajjas and any other position as per site requirement complete all as specified and as directed in following steps:-
Step-1 Opening of sealed container and dilute the chemical with water @ 1:3 using mechanical mixer to prepare primer and apply one coat of primer using roller and allow 4-6 hrs to dry for primer.
Step-2 Apply two coats of approved chemical roof treatment with roller to primed surface as per manufacturer's instruction anda allow 4-6 hrs to dry treatment. Note :-
(1) Removal of old roof treatment work is deemed to be included in rates
(2) work shall be got executed only from approved OEM.
Make:- Asian Smart Care Damp Proof / Berger Weather Coat Roof Guard / Nerolac Perma No Damp | 1,500 | Sqm | - | - |
| 9 | M & L for complete removal of existing treatment on wall and applying 1mm thick water proof putty over prepared surface. Complete all as specified and as directed. | 3,500 | Sqm | - | - |
| 10 | M&L for preparing and applying Dr. Fixit rain coat in following steps as appended below:-
(1) Existing substrates cleaned and removed all scale dirt, algea moss, fungal growth with high pressure water using high pressure jet washer. All loose plaster will be repaired with polymer modified mortar using Dr. Fixit pidicrete URP and norrow cracks upto 5mm shall be repaired with crack X-paste and the larger cracks upto 10mm with Dr fixit crack-X shrink free. The surface shall be made dry completely for upto 4-6 days for application of primer.
(2)Applying one coat primer Dr. Fixit prime seal diluted with 2:1 with water (prime seal:water) maintaining spreading rate @ 8 to 10 sqm / ltr complete all as specified and directed.
(3) Applying two coats of Dr Fixit raincoat without any dilution for coverage 3.5 sqm/ltr and second coat of Dr. fixit rain coat without any dilution for coverage 7 sqm/ltr complete all as specified and directed.
Note :-
(i) Second coat must be applied after lapse of 6 to 8 hours application of first coat.
(ii) The application of Dr Fixit raincoat must be avoided at temperature below 10˚C more than 35˚C and in direct sunlight. | 3,500 | Kg | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
TENDER_DOCU_8638.pdf
Tender Documents • 0.84 MB
credit8638.pdf
Additional Documents • 0.13 MB
BOQ_873244.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].