Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 LAccepted-AOC | L1 | Accepted-AOC L1 |
Tender Value
₹1.1 L
EMD Value
₹2,132
Closing Date
22 Jul 2022, 9:30 amClosed
Executive Engineer
EE, EandM Division, APWD, Prothrapur
Construction of Compound Wall and Burial Shed at Dugong Creek Little Andaman SW Providing IEI
2022_APWD_6517_1
NIT No. 14/EE/EandM/22-23 5th Call
Open Tender
Electrical Works
Item Rate
30 days
South Andaman
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹2,132
10 Aug 2022
11 Jul 2022
22 Jul 2022
11 Jul 2022
22 Jul 2022
15 Jul 2022
12 Jul 2022 - 14 Jul 2022
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required a) Group-C
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
b) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing of surface mounted LED Batten fitting for 20 Watt T-8 Lamp similar to Havells Cat No. LHFYBYPNIA1W022 or its equivalent, etc as required.
Supplying of LED 20 Watt T-8 Tube Lamp similar to Cat NO. C&S Cat No. LT4F20WLEDT8/WD or its equivalent, etc as required.
Supplying and fixing of LED Street Light Fitting 45 Watt similar to Crompton Cat No. LSTS-45-CDL-1 or its equivalent, etc as required.
Manufacturing and supplying of street light pole made out of 65 mm dia "B" class ISI Marked GI pipe with Zinc Coating not less than 360 mgs / sum 6 meters long with earth stud and necessary GI reducer / coupling fixed at the top and 300mm x 300mm x 6 mm thick MS base plate welded to the bottom including painting with one coat of metallic primer and 2 coats of synthetic enamel paint etc., as required
Supplying and fixing of 32 mm dia x 2.00 meters long GI Pip[e (Medium Class) bracket for mounting of fluorescent / HPMV/ HPSV street Light fitting on pole including bending the pipe to the required shape, 2 Nos. 40 mm x 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc., as required.
Erection of metallic street light standard pole of length exceeding 4.5 meters but not exceeding 6.5 metres in cement concrete 1:3:6 (1 Cement: 3 Coarse sand:6 graded stone aggregate 40 mm nominal size) foundation with cement concrete collar of size 0.4 m dia x 0.5 m height to accommodate the looping type cable end box including excavation and refilling etc., as required
Supplying of following size of XLPE insulated Heavy duty armoured Aluminium conductor UG Cable of 1.1 KV grade conforming to IS: 7098 Part-I) and IS No. 1554 (part-I) 1988 as applicable Make CCI/ Gloster/ havells/ Polycab/ Finolex etc., as required. a) 6 Sq.mm x 2 Core
Supplying and laying of one number double walled corrugated high density poly thylene pipe having corrugation on the outer wall and plain surface inner wall conforming to IS: No. 14930 Part I & II complete with necessary HDPE fitting for protection of 1.1 KV grade directly in ground at the depth of 50 cm i/c excavation & refilling the trench etc., as required. a) 50 mm outer dia & 38 mm inner dia
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. a) Upto 35 sq. mm
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 6 way, Double Door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required a) 40 A
Supplying and fixing Single Pole Blanking Plate in the existing MCB DB complete etc., as required
Providing earthing with safe earthing electrode of galvanization 80 to 100 microns, length 2000mm, outer dia 50 mm, inner dia 25 mm and inner space be filled with crystalline conductive mixture including filling -up with electrolite (Back fill compound) as required for safe earth electrode and providing masonary enclosure with cover plate having locking arrangement etc. as required. (Ashlok)
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. a) 40 A
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .