Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹15 L
EMD Value
₹15,000
Closing Date
24 Jul 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COMMISSIONER THANJAVUR CITY MUNICIPAL CORPORATION
THANJAVUR CITY MUNICIPAL CORPORATION
Providing Stainless Steel Bus Shelter at Ramanathan Roundana In Ward No 41
2025_MAWS_577782_1
5184/2025/MCE5
Open Tender
Civil Works - Others
Item Rate
180 days
THANJAVUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹15,000
24 Jul 2025
4 Jul 2025
24 Jul 2025
4 Jul 2025
24 Jul 2025
4 Jul 2025
Amount
Earthwork excavation in all soils and subsoils to full depth as may be directed except hardrock requiring blastering inclusive of all shoring, strutting and bailing out water wherever necessary and depositing the surplus earth with initial lead and lift etc., complete as per standard specifications.with conveyance upto 2Km lead
Supplying and filling in foundation and basement with filling M sand in layers of not more than 15cm.thick well rammed watered and compacted etc., complete complying with standard specification.
Plain Cement Concrete 1:4:8 (one cement, four fine aggregates and eight coarse aggregates) using 40 mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges etc., complete as per standard specification
Plain cement concrete 1:2:4 (one cement two M.Sand and four aggregates) mix using 20mm ISS gauge HBBG metal including cost and conveyance of all materials and labour charges for mixing, laying, complete and curing etc. complete
Brick work in CM 1:5 (one cement & five M.sand) using II class ground moulded bricks of size 8 3/4" x 4 1/4" x 2 3/4" including finishing, curing, etc., complete complying with standard specification (for Foundation Basement )
Plastering with cement mortar 1:5 mix 12mm thick etc., complete
Supplying ,Fabrication and fixing of Stainless Steel and polishing work of approved design using necessarry size of SS Pipes, Hollow sections ,angles, rods and flates including cost of materials and labour charges etc, complete.
Flooring with Cement Based Hydraulically pressed Anti Skid tiles of approved quality of size 30cmx 30cmx 6cm laid in cement mortar 1:3 mix 20mm thick and pointing with the same mortor etc., completely and finish perfectly.
Roofing with Polycarbonate Sheet 6mm thick with necessary bolts , Nuts and Washers including all materials labour charges etc..complete.
Supply and run of 2 of 4 sq.mm. (56 / 0.3) PVC insulated single core unsheathed copper conductor of 1100V on 7 / 20 GI bearer wire for service connection mains ( SD -65)
Supply and run of 2 of 4 sq.mm. (56 / 0.3) PVC insulated single core unsheathed copper conductor of 1100V grade in 25mm dia GI pipe (Class 'B') suitably bent at both ends with necessary angle iron upright and end supports for mains (SD -70)
Supply and Fixing of 20W LED Fittings including all labour charges complete as directed by the departmental officers.
Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated unsheathed single core copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box with 5A FT switch inflush with wall covered with hylem sheet of 3mm thick with painting of suitable colour for open PVC light point / fan point (SD- 21)
Providing and erecting of Direction and Place Identification Retro-reflectorised Sign made out of High Intensity Prismatic Grade Sheeting confirming to Type-IV standards of IRC-67: 2012 and ASTM D 4956 -09, specification and fixed over 2mm thickAluminium sheet fixed over a back supporting frame of 25mmx25mmx3mm Mild Steel angle and supported on a mild steel angle post 75X75X6mm with a clear height of not less than 2.10m from the ground level to the bottom of the sign board and 0.60m below ground level. The sign post should be painted as per IRC 67-2012 and firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45cmX45cmX60cm size including cost and conveyance of all materials, equipment, Machinery and labour with all leads and lifts, loading charges necessary for satisfactory completion of the work as directed by the engineer in charge. High intensity Retro Reflectro sheet shall consist of minimum coefficient of Retro-reflection as per Table 6.6 of IRC 67-2012. The retro- reflective sheeting shall be covered under 7 year warranty issued for field performance and a certified copy of three years outdoor exposure report shall be obtained as per IRC 67:2012. (as per MORT&HSpecification No.801)
Design,supply,Installation and commissioning of SOLAR PV power Back (Solar PV Panel 100 Watts) ,100AH,Battery.(Automatic Dusk to down operation) for Bus Shelter lighting with provision, including all labour charges etc.,complete
P SENTHILKUMAR (BID ID -1411215)
stage.html
html • 0.02 MB
finance_690496.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .