| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance A 03 KRISHNA TOWER ANAND NAGAR NEW LINK ROAD DAHISAR EAST MUMBAI 400068 MAHARASHTRA | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Not Admitted-Fee/PreQual/Technical 214 2ND FLOOR SAMRUDDHI COMMERCIAL PREMISES CHINCHOLI BUNDER ROAD MINDSPACE MALAD WEST | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹49.5 L
EMD Value
₹98,971
Closing Date
27 Jan 2021, 3:00 pmClosed
Director, CSIR NIO
CSIR- National Institute of Oceanography, Dona Paula , Goa 403004
Renovation of RC Mumbai Phase I Building at CSIR-NIO, Mumbai
2021_CSIR_67062_1
19/389/2021-Wks
Open Tender
Civil Works - Buildings
Item Rate
150 days
Lokhandwala Road, Four Bungalows, Andheri West
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
Yes
Director, NIO
₹98,971
Yes
5 Sept 2022
18 Jan 2021
29 Jan 2021
18 Jan 2021
27 Jan 2021
18 Jan 2021
18 Jan 2021 - 27 Jan 2021
Amount
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge.50mm average thickness
Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. Bars of below & above 12 mm diameter
Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2). 25 mm average thickness in 2 layers.
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer
Application of anticorrosive primer.Providing & applying 2 coats of a two component zinc rich anticorrosive primer Nitozinc primer of Fosroc chemicals(India) Pvt Ltd or equivalent containing at least 90% of Zinc and giving a dry film thickness of atleast 40 micron to the reinforcement bars.The primer should be applied according to the manufacturer instruction and as per direction of the Engineer-Incharge.Special care should be taken to apply Nitozinc primer behind the bars.The cost is inclusive of materials, scaffolding, labour, painting brush etc complete
6 mm plaster on cement concrete or reinforced cement concrete work with white cement based polymer modified self curing mortar of approved make as per the direction of Engineer-In-Charge.
12 mm cement plaster of mix 1:4: (1 cement: 4 coarse sand)
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade ..Applying priming coat with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works
Providing and fixing colour coated galvulium roofing sheets of 0.5mm thickness including all the accessories (TATA make) but excluding the cost of purlins, rafters, trusses, flashings etc.complete as per the directions of the Engineer incharge
Providing & fixing base plate of 250*250*12mm th.& making necessary holes as per bolt size including applying two coats of yellow chromate primer & painting 2 or more coats with black anticorrosive bitummastic paint of approved brand and manufacture
Providing and fixing structural Galvanized steel tubes frame at all heights using square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) of size 300x230x300 mm, including cost of necessary centering and shuttering and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support the structure.The steel work will be given a priming coat of Zinc primer as approved by Engineer-in-charge and painted with two or more coats of epoxy paint (Shop drawings certified by structural eengineer shall be submitted by the contractor to the Engineer in-charge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment and nothing extra shall be paid).
Providing and fixing angle fasteners & fittings including fixing 2 base plates
Providing & fixing PVC drain gutters of 7" half round on both side of the shed with iron clamps for support extra fittings,joints,elbows & stop end outlets & other necessary fittings.
Providing & fixing droppings for PVC drain gutters of 4" dia.PVC pipes & elbows & clamps.
Providing waterproofing treatment over the prepared surface with two or more coats with smart care damp proof course of Asian paints as per recommendation of manufacturers including all taxes, labour & transport complete
Finishing walls with Acrylic Smooth exterior paint of required shade : Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints Size of Tile 1000x1000 mm Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge
kumawat infrastructure pvt ltd
Concept Creator
Bhagyasri Design Construction
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .