Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹3.0 CrAdmitted-Finance N A | NA | NA | 121004 | -1.21% | ₹3.0 Cr | L1 | Admitted-Finance |
| 2 | L2₹3.0 CrAdmitted-Finance | -1.00% | ₹3.0 Cr | L2 | Admitted-Finance |
| 3 | L3₹3.0 CrAdmitted-Finance B 116 VIBHUTI KHAND GOMTI NAGAR LUCKNOW UTTAR PRADESH 226010 | LUCKNOW | UTTAR PRADESH | 226010 | -0.50% | ₹3.0 Cr | L3 | Admitted-Finance |
| 4 | Rejected-Technical | - | - | - | Rejected-Technical Disqualified |
Tender Value
Refer Docs
EMD Value
₹6.0 L
Closing Date
31 Dec 2025, 12:00 pmClosed
Superintending Engineer
SE Circle office UPJN Rural LKO
Construction of Parking for Two Wheeler and Four Wheeler vehicles at Head Office of UP Jal Nigam Rural, Lucknow
2025_UPJNG_1099590_1
2071/M-7/242 dt. 15.12.2025
Open Tender
Composite Works
240 days
Head Office of UP Jal Nigam Rural
As per Tender Document
2 documents required · 2 mandatory
₹11,800
PM Construction Unit
₹6.0 L
20 Jan 2026
16 Dec 2025
31 Dec 2025
16 Dec 2025
31 Dec 2025
16 Dec 2025
Supply,Installation,Testing and Commissioning of Ongrid Solar Photovoltaic PowerPlant conforming to MNRE specifications as amended, consisting of Mono/PolyCrystalline silicon solar cells,net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- A) Solar Photovoltaic Module of capacity 330Wp or above, manufactured in India, conforming to IS14286/IEC61215, IS/IEC61730-Part-1, IS/IEC61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than16.5%.PV modules used in solar power plants /systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. B) Power Conditioning Unit(PCU)of 350-800 V DC Input voltage range and 400V AC , three phase, 4wire, 50Hz+/-2.5Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3%and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. C) Data Monitoring System complete with accessories. D) Fixing of Array junctionbox & Main junction box with IP65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. E) Lightning and surge voltage protection. F) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1kV grade armoured power and control cables between solar modules, mainpower cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All kinds of soil
Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
Mechnical transportation of earth including loading, unloading and stacking Upto 5 km
For 6 km to 10 km
For 11 km to 15 km
For 16 km to 20 km
For 21 km to 25 km
For 26 km to 30 km
For 31 km to 35 km
For 36 km to 40 km
For 41 km to 45 km
For 46 km to 50 km
Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Concrete of M15 grade with minimum cement content of 240 kg /cum
Centering and shuttering including strutting, propping etc. and removal of form for Edges of slabs and breaks in floors and walls Under 20 cm wide
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in : Cement mortar 1:4 (1 cement : 4 coarse sand)
Designing ,Providing, fabricating, assembling and erection of pre stressed Special Architectural structure roofing structure with M.s.Tubular Frame Work (APOLLO/JINDAL/TATA ) in desired profile as per conceptual drawing , with Type II precontraint as per manufacturing and supplying standards by Serge Ferrari Equivalent with Precontrant Technology . The membrane should confirm to the manufacturing standard of being pre stretched in both weft and waft direction during manufacturing to perform best dynamic stability in both weft and waft direction with approved installers and Manufacturer for Architectural Roofing . The fabric must be of HT polyester yarns 1100 Dtex coated with uniform 230 micron PVC coating over the polyester yarn. The top quote over the PVC must be of high concentration with easy clean ability and superior white pigmentation of the membrane. The dimensional stability of the fabric should be measured as per elongation test of 24h -10daN/5cm which should confirm <1%-<1% (EN 15977) and residual elongation should confirm <0.4%-<0.4% (EN 15977) ensuring dimensional stability in both weft and waft direction, minimum weight should be 900 to 950g/sqm (EN ISO 2286-2), 4200 / 4000 N/50 mm (EN ISO 1421) and tear strength of 550 / 500 N (DIN 53.363) and with a Guarantee of 15 yrs (with non depreciating guarantee for first three years) from the manufacturer, width of the fabric should be 2.67 mtr, Adhersion 120 N (EN ISO 2411). Flame retardancy Bs2d0 -, Quality in conformity with ISO 9001 with 15 years warranty from manufacturer. The Membrane fabrication should confirm to standards of desired profile as per approved shop drawing including necessary designing with non-linear design software, seaming machine at least capacity from 20 kv to 25kv not including travelers seaming machine, CNC plotter & cutter machine for cutting of membrane pattern, swage end machine upto 30mm dia cables etc. The wilding should be using High Frequency welding machine of minimum welding seam width with 50 mm. This work shall include CHS members of YST 310 Mpa, plates - YST 245 MPa, anchor bolt , nut and washer are to be HDG Gr.8.8, structure steel cables should be with class A HDG wire rope with minimum tensile strength of 1570 MPa and single construction, swagged cable end connectors. All fabricated steel members should be zinc primer (DFT 50 microns minimum), top coat of HB epoxy paint (DFT 100 microns), top PU to coat (DFT 50 microns), over steel structure frames with all fittings and fixtures such as Stainless steel End Plate ,Shackles, Rigging Screws , Turnbuckles, swedge, fork , keder rods & galvanized MS strands with stainless steel end terminals asper Drawing / Detail & as per particular/ technical specifications and as per the directions of Engineer-in-charge and the submitted approved drawing. The contactor shall provide original Warranty certificate issued by his company with manufacturer warranty. Actual surface area of canopy end to end shall only be measured in square meter correct up to two decimal places. (Make - Construction Catalysers/AnconIndia/Grorich Horivert )
Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge
12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
Painting road surface marking with adequate nos of coats to give uniform finish with ready mixed road marking paint conforming to IS : 164, on road surface in white/yellow shade, including cleaning the surface of all dirt, scales, oil, grease and foreign material etc. complete. 16.48.1 New work (Two or more coats)
Trimixing of the surface of the cement concrete laid
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge - With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30
Transportation and shifting charges of all equipment, material to site & One point to other Point complete in all respect
STORM WATER DISPOSAL SYSTEM
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding with cost of binding wire all complete -Thermo-Mechanically Treated bars of grade Fe-500D or more.
RAIN WATER HARVESTING
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.- All types of soil- 300 mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.
Road and median work
Supply of Re-Polymer based modules of make InRain (Honeycomb Structure) made up of recycled polypropylene capable of taking vehicular movement up to 31 tonnes with adequate backfilling & 4 small plates combination creating 4 spans inside the module. These modules are made from combination of large (685*410mm) and small (370*411mm) plates along with external locks. Each large plate should have minimum fourteen external locking slots in order to give stability to tank. These tank should have optimum connection & block stability using double lock stability. Each single tank is made of four large and four small plates in case of single tank and 13 large & 16 small plates for quadruple tank. Capacity of single tank is (.685*.410*.450 mtr) equals to 0.126 CUM(gross). Weight of each large plate should be minimum 1.3 Kg and each small plate should be at least .650 Kg. The design to be approved by Engineer-in-Charge(make - ICPL OR EQUIVALENT)
Supply of non woven geotextile having thickness of 400 GSM, having minimum tear strength of 250 ASTM D4533, Width wise minimum 215 ASTM D4533 having puncture strength of 1550 plus asper ASTM D6241 Having elongation at Break of 57% plus as per ASTM D 4595 in single layers, made out of long fibres to hold the modules including cutting, sizing, Heat welding and needle punched for high porosity and proper percolation. complete as per entire satisfaction of engineer-in charge.(make - ICPL OR EQUIVALENT)
Supply of FRP based filtration device with diameter of 780 mm and height 1000 mm having inlet of 200mm and outlet of 200mm. capable of filtration in two stage, upper layer has SS304 mesh which can filter out solid suspended particle up to 600 microns & lower membrane is capable of filtering up to 90 microns. Flow rate of filtration device is upto 80 KL / hr. ( FRP based RWH Filter). as per satisfaction of engineer-in charge.(make - ICPL OR EQUIVALENT)
Supplying of required PVC PIPE 200 mm dia having 6 KG per centimetre square Pressure i.e. excavation, refilling, cutting & jointing for providing proper loop from/to existing storm water drain complete as per entire satisfaction of Engineer in charge. additional pipe will be charged extra.(make - ASTRAL, SUPREME OR EQUIVALENT)
Installation of Entire structure including welding of Geotextile and deboarding of Tank connection Filter from Manhole to filter and filter to RWHP, dressing of Base along cutting and sizing of busses and tree roots, Assembling of Modules. complete in all respect.
Construction of storm water disposal system using RCC NP3 Pipe of 300 mm dia with sufficient size,slope and number of manholes with perforated cover with proper barricadding works & safety standards complete work in all respect as per direction of Engineer-in-charge
ELECTRICAL WORK
Supply, Installation, Testing & Commissioning of 3mtr long, G I Octagonal Street Light Pole of 3 mm wall thickness consist of following as approved by Engineer-Incharge all completer in all respect (a) Supply of circular bracket suitable for post top lantern LED fitting (b) Supply & Installation of PVC JB with 1no. 6A SP MCB (c) Supply & Installation of 4P Terminal Block for Connections (d) The scope shall also include provision for passage of cable by using suitable size pvc pipe. (e) Supply & Installation of Base plate & 4 nos foundation Bolts.
NIT No. : 2071 / M-7 / 242 dt. 15.12.2025
(a) Providing & Erection of 250x250x750mm Concrete Foundation (including M-20 Grade Concrete and steel including excavation of pole pit. The concrete mix for RCC foundation of pole shall be M20. The scope shall also include grouting of foundation bolts including watering and ramming & provision for passage of cable by using suitable size pvc pipe etc. as reqd. (b) Supplying & installation, testing and commissioning of bollard light 2 to 3 feet height having 12 watt LED luminare (philips BCB500 LED16-4S/740 PSU II A DGR MSP CLO ) with all accessories including connection etc. and completeasperElectrical Engineer-in-Charge and consultants.
Supplying & installation,testing and commissioning of PHILIPS UNILinear Flex NEON, 46 w/5 mtrs WITH IP 65 protection
Supplying & installation,testing and commissioning of PHILIPS -31385 7W Anthracite COB Garden Spike 400
Supplying & laying of 1.1 Kv grade XLPE insulated PVC sheathed 4 core 10.0 Sq.Mm copper conductor armoured cable directly in existing trench or on surface of wall/pipe/pole i/c end termination etc. as approved by Engineer-Incharge.(make - Havells, Polycab Finolex Or Equivalent)
Supplying & laying of 1.1 Kv grade XLPE insulated PVC sheathed 3 core 4.0 Sq.Mm copper conductor armoured cable directly in existing trench or on surface of wall/pipe/pole i/c end termination etc.as approved by Engineer-Incharge.(make - Havells, Polycab Finolex Or Equivalent)
Supplying & laying of 1.1 Kv grade XLPE insulated PVC sheathed 3 core 2.5 Sq.Mm copper conductor armoured cable directly in existing trench or on surface of wall/pipe/pole i/c end termination etc. as approved by Engineer-Incharge.(make - Havells, Polycab Finolex Or Equivalent)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with jointing etc. in the existing trench, complete as required. fitting and cutting, jointing etc. in the existing trench, complete as approved by Engineer-Incharge. a) 90 mm dia (OD-90 mm & ID-76 mm nominal)(make - Jindal Plast, APL Apollo, Supreme Industries, and Dutron)
Providing and laying controlled cement concrete M.15 for curing complete excluding cost of formwork and reinforcement for reinforced concrete work in (A) Foundations, footings, Base of columns and Mass concrete. (Note- The item shall be used for 2" thick CC cushioning to DWC pipe around the periphery & PCC for chamber)
Constructing brick masonry chamber for underground C.I. Inspection chamber and bends with bricks having crushing strength not less than 35Kg/Cm2 in C.M. 1:5 C.I. cover with frame (Light duty) 455mm x 610mm intenal dimensions total weight of cover with frame to be not less than 38Kg. (Wt. of cover 23 Kg.) and Wt. of frame 15Kg. ) (R.C.C. top slabe with 1:2:4 mix (1-cement :2- coarse sand :4-graded stone aggregate 20mm size) foundation concrete 1:5:10 inside plaster 15mm thick with cement mortar 1:3 finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete.(i) Inside dimensions 455mmx 610mm and 450mm deep for single pipe line.
Steel work, welded in built up sections framed work including cutting, hoisting, fixing in position and applying a priming coat of red lead paint. (A) In beams and joists, channels angles Tees, flats, MS chequered plates, MS members with connecting plates or angle cleats as in main and cross beams/sections. Hip and jack rafters, purlins conneted to common rafters and the like as directed by Engineer-in-charge.
Supply , Installation, Testing & commissioning of floor mounting cubicle type feeder pillar with double door & rain canopy arrangement at top suitable for operation on 433 volt, TPN, 50 Hz, A C supply made out of 16 SWG CRCA MS sheet comprising of following switch gears & accessories complete with dust, vermin & weather proof hinged double doors for switch gears compartment, provision for earth termination, knock-outs for incoming and outgoing cables and conduits, 25x5 mm Al/GI Earth bus through out the base of panel, Din rail, connectors, Neutral links and interconnections with suitable size of copper wires, ferrules & two coats of anti corrosive powder coated paint after applying seven tank process including signwriting, angle iron base frame etc. as per detailed specifications & general drawing as reqd. a) 63 Amp 415 volt 10 KA TPN MCB incomer - 1 No b) 32 Amp 230 Volt 10 KA SPN MCB- 3 Nos c) 10 Amp 230 Volt 10 KA SP MCB- 12 Nos (make - Schneider Electric, ABB, Legrand)
COPPER BONDED ELECTRODE EARTHING (make - Electrogrip, Veraizen, Saara, Arete, Sun Sparkle, and Edison Electric or equivalent)
PUBLIC ADDRESS SYSTEM
Supply , Installation , Testing & commissioning of 2-way high efficiency, 40 watt high fidelity PA Music Horn. It uses a 6" Kevlar cone woofer and a 1" phenolic dome tweeter. Thus it combines the high efficiency of a horn with the wide frequency response obtained by using a 2-way woofer tweeter combination. Housed in a beautifully designed UV protected ABS plastic housing, the music horn is weather protected which makes it ideal for outdoor as well as indoor applications. (Make- Ahuja, Bosch, Yamaha or equivalent)
Supply , Installation , Testing & commissioning of 8 Zone Controller Supported Upto 2000 Watt Power Capacity (Make - Ahuja, Bosch, Yamaha or equivalent)
Supply , Installation , Testing & commissioning of Zone Call Station for Announcement. (Make - Ahuja, Bosch, Yamaha or equivalent)
Supply , Installation , Testing & commissioning of 1000 Watt Power Amplifier (Make - Ahuja, Bosch, Yamaha or equivalent)
Supply & laying of 2 Core 1.5 Sqmm Armoured Cable in Hdpe pipe. (Make - Havells, Polycab Finolex Or Equivalent)
Supply & laying of 40 MM Hdpe pipe . (Make - Jindal Plast, APL Apollo, Supreme Industries, and Dutron)
BOOM BARRIER & ACCESS CONTROL
(a) Providing & Erection of 400x400x1000mm Concrete Foundation (including M-20 Grade Concrete and steel including excavation of pole pit. The concrete mix for RCC foundation of pole shall be M20. The scope shall also include grouting of foundation bolts including watering and ramming & provision for passage of cable by using suitable size pvc pipe etc. as reqd. (b) Supplying, Installation, testing & commissioning of Post-Top indirect symmetrical light distribution die-cast aluminium landscape IP65 luminaire with high power COB LED as light source with minimum 35 watt(Min 100 L/W) LED as light source with driver having 5700 deg K colour temperature, IP 65 protection class in single piece pressure die-cast aluminium housing etc. as approved by Engineer-Incharge. (Make: K lite dixon pro or equivalent )
TENSILE STRUCTURE
a) Supply, Installation & commissioning of 2 no. Boom Barriers with Minimum length of 6 mtr. , Arm of alluminium with protection degree of IP54, Auto closing time 1 to 80 sec, with automatic/manual mode, Motor power of 90W, 220V AC or Similar, Boom Barrier should be standalone access control, control botton incorporated control panel with 3 push bottons (STOP/UP/DOWN) to control the motor. (Make - Construction Catalysers/AnconIndia/Grorich Horivert ) b) 2 no. Access controller of card capacity of upto 25000+ & log events capacity of 1,00,000 with TCP/IP & RS-485 communication, Powder Coated Aluminium Enclosure; Wall Mount; Built -in Auxiliary input and output; Support Full Range of card Reader; Desktop Based Software with Database type:MS Access / MS SQL c) 2 no. UHF Long range integrated RFID with minimum range of 10 mtr. & reading speed of Multi tag 200 PCS/Sec & Single
OTHER WORKS
Providing Retro-reflective regulatory sign board of size 900 mm dia metre made out of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated lens type retro -reflective sheeting as approved by Engineer-in-char
Horticulture operations including 300 mm earth filling, grassing tree plantation/shrubs and potted plants etc
ge . Letter, symbols, borders etc. will be as per IRC - 67 with required colour scheme on the boards and with the high intensity grade A. The aluminium sheet to be riveted to M.S. frame of angle iron of size 40x40x4 mm. The boards will be fixed to 1 No. 50x50 mm square post made of M.S. angle 50x50x4 mm, 4 m long welded to the frame with adequate anti-theft arrangement .Sheet work to be painted with two or more coats of synthetic enamel paint over an under coat (primer) and back side of aluminium sheet to be painted with two or more coats of epoxy paint including appropriate priming coat complete in all respects as per direction of Engineer-in-charge.
tag 2000 times/min, 16 KB tag data Memory and 32 KB non-volatile Storage d) 2 no. Photo Cell Sensor for auto door opener/ infrared sensor with range of less than 10 M e) 2 no. Short Range Card Reader of 125 khz proximity & reading time on <300ms,protection degree of IP65+ f) 100 no. UHF cards and tags range from 860-960 MHz frequency and have the ability to be read at extended ranges (up to 20+ feet away) (Make - GODREJ, eSSL or equivalent )
Demolishing cement concrete manually/ by mechanical means including disposal of material as per direction of Engineer - in - charge
Mild steel section of gardern outdoor bench with Cast Iron leg supports of size 1460 mm x 580 mm x 750 mm , Minimum weight of bench should not be less than 75kg
FIRE FIGHTING
Dismanteling of old structure, clearance of site and disposal of unservicable material, shifting of old vehicles , Getting NOC from respective departments (ASI, Forest department and any other as per site condition ), Power Connection for Parking area from Existing Main power connection of UPJNR campus etc. and making site ready for construction of parking project.
Supply & Installation Of ABC Multipurpose Map Powder Type ISI Mark Fire Extinguishers Of Capacity 6 Kg (Make - Flame Cool or equivalent)
Supply & Installation of Co2 Type Fire Extinguishers 4.5 Kg Cap ISI Mark (Make - Flame Cool or equivalent)
CCTV CAMERA SYSTEM AND ALLIED WORKS
Supply,Installation,Testing and Commissioning of CCTV CAMERA SYSTEM and allied works complete in all respect as per details mentioned in technical specification of tender document & as per direction of Engineer-In-charge.
SOLAR PANEL WORK
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.87 MB
TenderDoc.pdf
Tender Documents • 4.33 MB
BOQ_2025627.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid