Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.4 LAccepted-AOC 205 IIND PHASE INDUSTRIAL AREA BARMER 344001 | BARMER | BARMER | RAJASTHAN | 344001 | L1 | Accepted-AOC AOC | |
| 2 | L2₹17.9 L+₹92,040 (5.42%)Rejected-Finance UTARLAI KAWAS BARMER RAJASTHAN 344 001 | BARMER | RAJASTHAN | 344001 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹18.5 L+₹1.5 L (8.92%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹18.7 L+₹1.7 L (10.1%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹19.5 L+₹2.5 L (14.7%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
30 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Utarlai
GE (AF) Utarlai PB No. 11 Barmer (Raj) 344001
REPAIR TO CERTAIN MISC WORK SERVICES IN TECH BLDG IN TECH AREA AT AF STN UTARLAI
2023_MES_616513_1
8426/E8
Open Tender
Civil Works
Item Rate
180 days
Utarlai
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) Utarlai
₹38,000
Yes
24 Nov 2023
31 Aug 2023
2 Oct 2023
1 Sept 2023
30 Sept 2023
14 Sept 2023
Amount
Demolition of un-reinforced cement concrete in ground floor and paving not exceeding 15 cm thick (below or above ground level) complete all as specified and directed
M&L for 75 mm thick cement concrete 1:4:8 type D--2 (using 40mm graded stone aggregate) finished surface even and fair without using extra cement as in floor hard standing complete all as specified and directed
M&L for 150mm thick cement concrete 1:2:4 type B--2 (using 40mm graded stone aggregate) finished surface even and rough without using extra cement as in floor hard standing complete all as specified and directed
M&L for forming construction joint 10mm wide and 30mm deep and filled with sealing compound Grade 'B'
M&L fo forming construction (dumy) joint 65mm deep and 10mm wide filled with sealing compound Grade 'B'
Taking down cement plaster including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed
Demolition of precast block masonry work built in cement mortar of any description complete all as specified and directed by Engineer - in - Charge.
M&L for precast cement concrete block masonary with solid blocks made of PCC (1:3:6) type C-1 using 20 mm graded stone aggregate exc 10 cm in width and set in CM 1:6 complete all as specified and directed
M&L for percast cement concrete block masonary on CM 1:6 except blocks complete all as specified and directed.
M&L for 15mm thick rendering in CM 1:6 on brick/concrete wall surfaces finished even and smooth without using extra cement complete all as specified and directed
M&L for preparation on new plaster surface of walls & applying two coat of cement base paint over a coat of primer complete all as specified and directed
S&F in repairs Wire netting of stainless steel wire Size of mesh in 12mm 1.4mm dia fixed with tinned tacks of stainless steel wire staples
Taking down existing padding over edges of MS steel door and providing suitable padding of glass wool or rubber padding 12mm thick as per required to seal full door, including drilling Ms steel door for fixing screw , and including Cup washer and screw or fixing glue, upto 4" width strip complete all as specified and directed
Repair to crack of gantry support RCC projection with micro concrete including taking down loose concrete / plaster and including errection and dismantling scafolding and finish existing surface with floor or wall (Note :- Clean/making good cement spots on wall and floor)
Repair to edges of weep hole upto 200x200 3mm size and finish of wire mesh with XPM 25mm x 3mm with MS flat including drill over RCC , stone/ brick masonary wall and plaster and including screwes , including necessary scafolding and its erection and dismantling
S& F prepainted gaivatume aluminium zink coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 mpa as in roof covering/cladding to wall fixed with L type or J type or cranked hook bolt/self tapping sccrews including dismantling of old sheeting complete all as specified and direcetd.
S& F prepainted gaivatume aluminium zink coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 mpa as in roof covering/cladding to wall fixed with L type or J type or cranked hook bolt/self tapping sccrews including dismantling of old sheeting complete all as specified and direcetd.
M&L for machine cut kota stone slab flooring 20.25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including demolition of old stone slab complete all as specified and directed.
M&L for kota stone slab 20.25mm thick in riser of steps, skirting, dado and piller laid over cement screed and jointed with complete all as specified and directed.
M & L in replacement of Earthing complete with 60cmx 60cmx3mm thick GI plate electrode buried in ground vertically not less than 2.25mtrs deep below ground level with top edge of the plate not less than 1.5mtrs below ground level with GI wire of size 4 mm dia as earthing lead including necessary excavation and earth work (in any of strata) providing charcoal dust, salt mixed in continuous layer 15 CM all around the plate and balance pit will be filled with vigitable soil approved by engineer in charge, PCC (1:3:6 ) type C1 in chamber ,Precast 50 mm thick in cement ( 1:2:4) type B.1 with CI frame with cover, 20mm dia bore light grade GI watering pipe funnel etc fixing of GI Pipe 15 mm bore protection for earthing wire from earth pit to test point complete & making connection all as directed by Engineer-in-Charge. Note:-(i) GI wire 4 mm dia upto 7.5 mtr length shall be deemed to include in this items rate. (ii) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost by the contactor.
M&L in replacement of earthing complete as per electrical plate No. 3 of MES SSR Part-I with galvanised steel earth plate electrode 60cmx60cmx6.3mm thick, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less then 1.5 metre below normal ground level connected to and including galvanised iron earth strip 32 mm x 6 mm by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing strip shall be protected by galvanised iron or steel pipe 40mm bore light grade and connected pole / test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, (in any type of strata ) charcoal, salt, funnel PCC pit and RCC cover complete all as specified & tested complete.Note:-(i) GI strip 32 x 6 mm upto 7.5 mtr length shall be deemed to include in this items rate.(ii) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost by the contractor.
S&F in replacement of Galvanised Iron Strip 32x6mm with Saddles and fixing Screws for Roof/Earth Conductors and Down Conductors above Ground including taking down unserviceable Strip, complete all as specified and as directed. NOTE : All Joints should be joined by welding or by using of nuts and bolts& washers.
S&F in replacement of Galvanised Iron Tubing/Pipe 40mm bore (dia), light grade for Strip Protection, fixed in Walls/Floors with suitable type of Clamps, etc. including taking down unserviceable GI Tubing/Pipe, complete all as specified and as directed.
S&F replacement of Aluminium Strip 25 x3 mm with Saddles on PCC 1:2:4 block of size 150x150x150mm and fixing Screws/fasteners for Roof/ Earth Conductors and Down Conductors above Ground all Joints should be connected by Exothermic Welding or welding including taking down unserviceable Strip, complete all as specified and as directed. NOTE : All Joints should be joined by Brazing or by using of nuts and bolts & washers
S&F in replacement of Test Point Terminal Block made of Gun Metal or Phosphorus Bronze size 75x75x25mm, drilled and screwed including 3 No. 8mm dia, 25mm long hexagonal Head Screw including taking down/out unserviceable Test Point Terminal Block, complete all as per specified and as directed.
S&F in replacement of Air Termination Single Pointed Aluminium Rod 12 mm dia and up to 300 mm long with Arrester Clamp 12mm made out of Brass/ Gun Metal fixed on 40mm dia GI pipe light grade including provision of Cement Concrete 1:2:4 (20mm graded stone aggregate) Block 300x300x300mm (and necessary Fixing Arrangement at Roof all Joints should be connected by Exothermic Welding or Brazing complete all as specified and as directed.
M&L in replacement of Earth continuity conductor or main earthing lead 4mm dia galvanised iron or steel wire fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required
Taking out and re-fixing old loose / displaced aluminium /GI/Copper strip with new saddles screws etc on PCC 1:2:4 block of size 150x150x150mm for roof conductor /down conductor without PCC blocks upto test point above ground level complete all as directed .NOTE : All Joints should be joined by Brazing or by using of nuts and bolts & washers. Cost of saddles and PCC block is deemed to be included in rate quoted by the contractor.
S&F in replacement of Earthing funnel of 20 mm dia with wire -mesh all as specified as directed
S&F in replacement of earthing pit identifier / marker for lightening arrester made of MS plate 6 mm thick oval size having major axis 30 cm & minor axis 20 cm mounted on 25 mm dia GI pipe medium grade project 60 cm above the ground and 60 cm embeded suitably in concrete PCC 1:2:4 type B2 of size 20 cm x 20 cm x30 cm. The oval shape identifier & earthing pit cover shall be painted with two coat of synthetic enamel paint over a coat of primer and writing letter e.g. LA 1/10 on the plate and earth pit cover all as specified and directed by Engr-in-Charge.
M&L for Checking of any breaking in the Link of Earth Strip/Wire of Galvanised/ Copper/Aluminium any size and jointing them by welding or Brazing by using of nuts and bolts , complete all as specified and as directed.
M&L in repairing of Damaged Earth Pit/Chamber in Cement Concrete 1:3:6 type C-I 20 mm grade stone aggrigate as shown in Electrical Plate No 3 of MES Schedule Part-I including providing Pre-cast PCC cover in PCC 1:2:4, including Funnel with wiremesh and cleaning the surrounding of Earth Pit Cover and pouring Salt Water to improve the resistace and measuring and recording the same in presence of user / Engineer-in-Charge complete all as specified and as directed.
M&L repairs Pre-cast cement Cover in Cement Concrete 1:2:4 type B1 with handle made of 8mm dia RTS bar, including thrownout damaged / detrioted PCC outside cantt area, complete all as specified and as directed.
Supply and lay in replacement of steel water tubing GI medium grade ISI marked with all fittings laid in trenches etc complete for the following sizes including taking out old uerviceable pipe lines all as directed by Engr -in- Charge :-
15 mm dia bore
25 mm bore
Supply and fix in repairs stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed of size 15 mm dia
Supply and fix in repairs stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed of size 25 mm dia
S& F in repair bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/20mm- 125gms) complete all as specified and directed by Engr-in-Charge.
Excavation in trenches not exceding 1.5m wide and not exceding 10.0 sq m on plan and not exceding 1.5m depth and getting out soft soil.
Returing filling in including spreding leveling watering and well ramming in layer not exceding 25 cm as in soil all as specified and dirceted.
Removing excavated material not exceding 50 m and depostingwhere directed at a level not exceding 1.5 m above the starting point.
S&F Point wiring for flame proof light point controlled by one switch with 1100 volts grade 1.5 sqmm PVC insulated unsheathed FRLSH multistranded copper conductor cable as per IE colour code for phase /neutral /earthing wire drawn into and including rigid in stove enamelled mild steel ERW conduit medium grade minimum 20mm dia and accessories concealed in walls/roof/floors with continuous 1.5 sqmm PVC insulated unsheathed FRLSH multistranded copper conductor cable as earth continuity conductor and connecting to common earth dolly complete including cutting chases in brick/ block/stone masonry wall , replastering and making good to match the existing specifications including taking down old point wiring complete all as directed.
S&F in replacement for flame proof wiring with 2 runs of 4.0 sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade drawn through and included ERW mild steel conduit of minimum 20mm dia external (which shall be increased as per actual site requirement in Accordance of clause No 19.125.07 SSR part -I) with all conduit accessories like bends,juction boxes etc and FRLSH PVC insulated unsheathed copper conductor wire of 4.0 Sqmm as a continous earth wire fixed on wall surface /ceiling . Note : 2 runs of 4.0 sqmm FRLSH PVC insulated unsheathed copper conductor and 1 run of 4.0 sqmm FRLSH PVC insulated unsheathed copper conductor and 1 run of ERW mild Steel conduit of size 20 mm will be measured as single run.
Supply and fix in replacement of FLP/WP switch 16 Amp, 250V single pole ON/OFF rotary type with termination box in LM6 all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of FLP/WP switch 16 Amp, 250V double pole ON/OFF rotary type with termination box in LM6 all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of FLP/WP switch 25 Amp, 250V double pole ON/OFF rotary type with termination box in LM6 all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of flameproof DB handle as per existing all as specified and directed by Engr-in-Charge.
S&F in repair in replacement of LED flame proof weather proof flood light fitting 40 watt recommended for gas/vapour group of IIA &IIB and zone 1&2, die cast aluminium housing with heat resistant toughened glass IP 66 protection, constant current LED driver, prewired with all accessories complete fitting. Note: The light fitting should be fixed on height upto 15 mtr include taking down old fitting. All T&P for working at site shall be deemed to be included in the quoted rates.
M & L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint
S & F in replacement of Flame proof weather proof LED 1x20 watt tube light fixture 4 feet including LED 20W tube rod 4 feet,including integral reflector made of alluminium alloy LM6 with wire guard,bipin holders,.connector block, etc., and all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor with suitable size.recommended for gas/vapour group of IIA & IIB and zone 1&2 IP 66 protection surface mounted LED batten.
M/S Tanisha Traders
AMBEY MAA CONSTRUCTION COMPANY
Devi Engineeing
S.K. INFRASTRUCTURE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .