Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 CrAdmitted-Finance | ₹2.6 Cr | L1 | Admitted-Finance |
| 2 | L2₹3.8 Cr+₹1.3 Cr (49.0%)Admitted-Finance EAST LANE GALI NO 01 ABROL NAGAR PATHANKOT PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | ₹3.8 Cr+₹1.3 Cr (49.0%) | L2 | Admitted-Finance |
| 3 | L3₹4.0 Cr+₹1.4 Cr (55.1%)Admitted-Finance | ₹4.0 Cr+₹1.4 Cr (55.1%) | L3 | Admitted-Finance |
| 4 | L4₹5.5 Cr+₹2.9 Cr (113.5%)Admitted-Finance | ₹5.5 Cr+₹2.9 Cr (113.5%) | L4 | Admitted-Finance |
| 5 | L5₹5.6 Cr+₹3.0 Cr (118.1%)Admitted-Finance | ₹5.6 Cr+₹3.0 Cr (118.1%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/s V6 Infrastructures Pvt. Ltd. L7 | M/S BHATIA BUILDERS AND CONTRACTORS L5 | Onkar Nath Bhalla And Sons Contractor Pvt. Ltd. L4 | M/S KIRAN CONSTRUCTIONS L8 | SHIV CHARAN GUPTA AND SONS L3 | SRM BUILDERS AND ENGINERS PVT.LIMITTED L2 | Continental Enterprises L1 | TRIVENI CONSTRUCTIONS L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00BUILDING PART:- | |||||||||||
| 1.01 | SCHEDULE 'A' PART-I (SECTION-I)
Construction of block of Hanger building 53.00X 18.00 m including Annexe, PEB Structure, all as shown on drawing, with following specification :-
(a) Earthwork in excavation in any type of soil
(b) PCC 1:4:8 in foundation.
(c) RCC M-25 in foundation footings.
(d) Mild steel TMT bars as in reinforcement
(e) Rolled mild steel work in Structural member
(f) Walls of 100 mm thick PUF Panels with 0.50mm thick Galvolume sheet with one side profile & other side plain
(g) Roof of 50 mm thick PUF Panels with 0.50mm thick Galvolume sheet with one side profile & other side plain.
(h) 1 mm thick PU flooring over 2 mm thick self leveling base course over 150 mm thick PCC 1:1.5:3,150 mm PCC 1:4:8 & 150 mm thick hard core for main hanger.
(j) 10 mm thick ultra charged vitrified tile flooring for Annexe & Non skid ceramic tile for toilets.
(k) Stainless steel wire mesh ceiling for main hanger, mesh size 40 mm with 1.50 mm dia wire
(l) 12 mm thick Calcium silicate board ceiling in Annexe.
(m) Two coats of synthetic enamel paint over red oxide over shot blasted SA 2.50.
Cont/-1.01 | 1 | Each Job | 5,25,00,000 ₹5,25,00,000 | 5,15,00,000 ₹5,15,00,000 | 5,06,00,000 ₹5,06,00,000 | 5,75,00,000 ₹5,75,00,000 | 3,60,00,000 ₹3,60,00,000 | 3,50,00,000 ₹3,50,00,000 | 2,21,00,000 ₹2,21,00,000 Lowest | 5,19,00,000 ₹5,19,00,000 |
| 1.02Note :- Rates quoted by the contractor shall also deem to include the cost of the following :- (i) Design of PEB structure Building along with structural system shall be design by the designer from PEB approved firm/vender as listed in particular specifications along with vetting of design/drawing from IIT . (ii) Design of RCC foundations. (iii) Arch drgs provided by the department will form part of contract however structural drawings for hangar provided by contractor, which will be vetted by IIT. (iv) The structural steel members shall be designed as specified here in before and in particular specifications. | |||||||||||
| 2.00 | Total amount of Sch 'A' PART-II (SEC-I) (ROAD/PATH WORKS) | 1 | Lumpsum | 10,75,000 ₹10,75,000 | 10,53,653.54 ₹10,53,653.54 | 9,66,654.63 ₹9,66,654.63 Lowest | 12,00,000 ₹12,00,000 | 9,66,654.63 ₹9,66,654.63 Lowest | 9,66,654.63 ₹9,66,654.63 Lowest | 9,95,654.26 ₹9,95,654.26 | 12,00,000 ₹12,00,000 |
| 3.00 | Total amount of Sch 'A' PART-III(SEC-I)(SEWAGE DISPOSAL WORK) | 1 | Lumpsum | 1,75,000 ₹1,75,000 | 1,24,136.75 ₹1,24,136.75 | 1,19,823.12 ₹1,19,823.12 | 1,25,000 ₹1,25,000 | 1,19,823.12 ₹1,19,823.12 | 1,19,823.12 ₹1,19,823.12 | 1,21,100 ₹1,21,100 | 1,10,000 ₹1,10,000 Lowest |
| 4.00Sch 'A' PART-III (SEC-II) (SEWAGE DISPOSAL WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only. | |||||||||||
| 4.01 | Construction of Soakage well, of internal size 3 m dia and 3 m deep ( brick masonry construction) complete all as specified and shown on drawings .Drg NO. CEAF/STD-15/2000 SH1/2 & 2/2 | 1 | Each Job | 1,55,000 ₹1,55,000 | 1,59,000 ₹1,59,000 | 2,00,000 ₹2,00,000 | 1,75,000 ₹1,75,000 | 1,53,000 ₹1,53,000 | 1,00,000 ₹1,00,000 Lowest | 1,20,000 ₹1,20,000 | 1,20,000 ₹1,20,000 |
| 4.02 | Construction of septic tank 25 users, Brick construction complete all as specified and as directed and shown on drawing. .Drg NO. CEAF/STD-15/2000 SH1/2 & 2/2 | 1 | Each Job | 1,92,000 ₹1,92,000 | 1,80,000 ₹1,80,000 | 2,00,000 ₹2,00,000 | 2,00,000 ₹2,00,000 | 2,70,000 ₹2,70,000 | 75,000 ₹75,000 Lowest | 90,000 ₹90,000 | 2,00,000 ₹2,00,000 |
| 5.00 | Total amount of Sch 'A' part-IV (AREA DRAINAGE WORK) | 1 | Lumpsum | 4,10,000 ₹4,10,000 | 4,22,252.29 ₹4,22,252.29 | 3,57,840.93 ₹3,57,840.93 Lowest | 4,50,000 ₹4,50,000 | 3,57,840.93 ₹3,57,840.93 Lowest | 3,57,840.93 ₹3,57,840.93 Lowest | 3,75,732.97 ₹3,75,732.97 | 5,00,000 ₹5,00,000 |
| 6.00 | Total amount of Sch 'A' PART-V (Sec-I) ( INTERNAL WATER SUPPLY AND PLUMBING WORK) | 1 | Lumpsum | 2,25,000 ₹2,25,000 | 2,08,921.04 ₹2,08,921.04 | 2,00,000 ₹2,00,000 | 2,25,000 ₹2,25,000 | 1,00,442.81 ₹1,00,442.81 Lowest | 1,00,442.81 ₹1,00,442.81 Lowest | 1,01,000 ₹1,01,000 | 1,90,000 ₹1,90,000 |
Tender Value
Refer Docs
EMD Value
₹3.2 L
Closing Date
9 Oct 2021, 6:00 pmClosed
CE AF UDHAMPUR
CE AF UDHAMPUR
PROVISSION OF COVERED PARKING APRON CPA WITH ANNEXES AT SATWARI JAMMU (CEAFU-10/2021-22)
2021_MES_469764_1
CEAFU-10/2021-22
Open Tender
Civil Works
Lump-sum
120 days
JAMMU
REFER AS PER NIT AND TENDER DOCUMENTS
10 documents required · 10 mandatory
₹2,000
Yes
GE P AF JAMMU
₹3.2 L
Yes
9 Nov 2021
21 Aug 2021
11 Oct 2021
21 Aug 2021
9 Oct 2021
27 Sept 2021
21 Aug 2021 - 13 Sept 2021
Amount
BUILDING PART:-
SCHEDULE 'A' PART-I (SECTION-I) Construction of block of Hanger building 53.00X 18.00 m including Annexe, PEB Structure, all as shown on drawing, with following specification :- (a) Earthwork in excavation in any type of soil (b) PCC 1:4:8 in foundation. (c) RCC M-25 in foundation footings. (d) Mild steel TMT bars as in reinforcement (e) Rolled mild steel work in Structural member (f) Walls of 100 mm thick PUF Panels with 0.50mm thick Galvolume sheet with one side profile & other side plain (g) Roof of 50 mm thick PUF Panels with 0.50mm thick Galvolume sheet with one side profile & other side plain. (h) 1 mm thick PU flooring over 2 mm thick self leveling base course over 150 mm thick PCC 1:1.5:3,150 mm PCC 1:4:8 & 150 mm thick hard core for main hanger. (j) 10 mm thick ultra charged vitrified tile flooring for Annexe & Non skid ceramic tile for toilets. (k) Stainless steel wire mesh ceiling for main hanger, mesh size 40 mm with 1.50 mm dia wire (l) 12 mm thick Calcium silicate board ceiling in Annexe. (m) Two coats of synthetic enamel paint over red oxide over shot blasted SA 2.50. Cont/-1.01
Note :- Rates quoted by the contractor shall also deem to include the cost of the following :- (i) Design of PEB structure Building along with structural system shall be design by the designer from PEB approved firm/vender as listed in particular specifications along with vetting of design/drawing from IIT . (ii) Design of RCC foundations. (iii) Arch drgs provided by the department will form part of contract however structural drawings for hangar provided by contractor, which will be vetted by IIT. (iv) The structural steel members shall be designed as specified here in before and in particular specifications.
Total amount of Sch 'A' PART-II (SEC-I) (ROAD/PATH WORKS)
Total amount of Sch 'A' PART-III(SEC-I)(SEWAGE DISPOSAL WORK)
Sch 'A' PART-III (SEC-II) (SEWAGE DISPOSAL WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Construction of Soakage well, of internal size 3 m dia and 3 m deep ( brick masonry construction) complete all as specified and shown on drawings .Drg NO. CEAF/STD-15/2000 SH1/2 & 2/2
Construction of septic tank 25 users, Brick construction complete all as specified and as directed and shown on drawing. .Drg NO. CEAF/STD-15/2000 SH1/2 & 2/2
Total amount of Sch 'A' part-IV (AREA DRAINAGE WORK)
Total amount of Sch 'A' PART-V (Sec-I) ( INTERNAL WATER SUPPLY AND PLUMBING WORK)
Sch 'A' PART-V (SEC-II) ( INTERNAL WATER SUPPLY AND PLUMBING WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
S&F 75 mm PVC (SWR) bend complete all as speciefied and as directed
S&F 110 mm PVC (SWR) `P' trap complete all as speciefied and as directed
S&F C P health Faucets with flexible tube 15mm dia 1 Mitre long for EWC including all connection complete and all as specified and as directed
Total amount of Sch 'A' -VI (Section-I) (EXTERNAL ELECTRIFICATION AND COMMON NATURE ITEM WORK)
SCHEDULE `A' PART-VI (Sec-II) ) EXTERNAL ELECTRIFICATION WORKS Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Supply, installation , testing and commissioning of LT panel indoor type confirming to IS 8623 Part I(one) ,CPRI approval , totally enclosed vermin proof suitably ventilated for 3 phase , 4 wire 415 Volts, 50Hz, AC supply, outer shell shall be made out of 3.0mm thick CRCA sheet & MS angle section of suitable size for frame , factory fabricated , compartmentalized inner shell shall be made of out of 2.0mm thick CRCA sheet for control gear. Front and back door opening with locking arrangement at front. Protection of enclosure IP 56 as per IS-2147 of 1962 with pre- treatment through 7 tank hot chemical process prior to powder coating and powder coated with minimum 50-70 micron of approved colour. The bottom of outer shell contains a detachable plate having provision for entry of armored cable of adequate size. Computer cut self-adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided. EPDM gasket of appropriate shape and size provided at all joints, doors and covers including suitable size angle iron/flat iron frame work / support required with four legs 60 cm long using angle iron 70x70x25 cm , air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs legs grouted in PCC 1:2:4 and making good disturbed surface complete and comprising of the following :- A. (i)TPN Aluminum electrolytic grade bus bar of capacity 200 Amps for phases & 150 Amps for neutral. And auxiliary busbar to support main busbar. duly supported on SMC/DMC, busbar supports and insulated with colour coded heat shrinkable sleeve. Cont..... .item no .9.01
(ii) Digital multifunction meter(V,A,KW,KWH),415V AC alongwith C.T’s of suitable ratio (set of three),class 1.0, complete. (iii) Indication lamps LED type (RYB) = 01 Set of three. CTs 500/5A class 1.0,15VA(Cast Resin) for metering-03 nos .(iv) Internal wiring, with suitable size of FRLS copper conductor cable B. INCOMER:- (i)MCCB 100 Amp 4 pole,16 KA ,Ics=100% Icu, with fixed magnetic and adjustable thermal release,adjustable overload 80-100%and adjustable short ckt 5 to 10ln setting complete with phase separator - 01no C. OUTGOING: (i) MCCB 63 amp 4 pole, 16KA, Ics=100% Icu with fixed magnetic and adjustable thermal release,adjustable overload 80-100%and adjustable short ckt 5 to 10ln setting complete with phase separator - 02nos (ii) Phase sequence corrector unit -01 nos (iii) MCB SPN 63 Amp -02 Nos (iv) Changeover switch 100 amp- 01 no complete all as specified and as directed by Engr-in-charge. Note:- (i) LT Panel shall be CPRI approved (ii)Contractor shall submit the following Test report i.e. IP Test Report and verification of short circuit withstand test report issued by CPRI in respect of LT Panel. (iii) Contractor shall submit drawing for approval prior to place order.
S&F integral LED Aviation light comprising of aluminum housing with poly carbonate enclosure of make Bajaj Cat – BGAV 302 LED complete all as specified and as directed by Engr-in-Charge.
SCHEDULE `A' PART VI(SEC-II) EXTERNAL ELECTRIFICATION WORKS & PART-VIII (Sec-II)(LIGHTENING PROTECTION WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
M & L for earthing complete with GI Plate of size 600 x 600 x 6 mm thick electrode burried directly in ground ( earth pit not less than 2.25 mtr deep below normal ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI Strip of size 32 x 6mm . by means of nuts , bolts and washers of GI, protected by GI Pipe medium grade of 40 mm dia and with GI watering pipe medium grade 20 mm dia with funnel and wire mesh, including excavation and earth work in any type of soil and enought salt ,charcoal etc.Earth Pit of PCC (1:2:4) type B-1 with earth pit CI cover with suitable handle complete all as shown in electrical plate No 3 of SSR-2009(Part-I) including testing on completion all as specified and directed by Engr-in-Charge.
Total amount of Sch 'A' PART-VII (Section-I) (INTERNAL ELECTRIFICATION WORK)
Sch 'A' Part-VII(Section-II) (INTERNAL ELECTRIFICATION WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Supply & fixing slim linear LED lighting fixture 5 watt LED Batten T5, with full base of extruded aluminum section acting as a heat sink with closed back, isolated driver, CRI > 70, PF > 0.9 surge protection upto 2.0 KV, polycarbonate diffuser with system efficacy > 100 Lm/watt. Operating voltage 170-240 volts colour temp (5000-6000)K, low heat generating LED (Make of LED shall be cree/ Nichia/Osram) complete making all connections using 1.5 Sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose to fitting complete all as per the direction of Engg-in-charge. Note : (i) The conductor shall obtain LM 80 & LM 79 reports for the light fittings from manufactures for lot to be supplied and submit to the department. (ii) A certificate from the manufactures for warranty minimum upto 2 years shall be obtained and submitted to the AGE/GE office
Supply & fixing slim linear LED lighting fixture 20 Watt LED Batten T5, with full base of extruded aluminum section acting as a hear sink with closed back, isolated driver, CRI > 70, PF > 0.9 surge protection upto 2.0 KV, polycarbonate diffuser with system efficacy > 100 Lm/watt. Operating voltage 170-240 volts colour temp 6500K, low heat generating LED (Make of LED shall be Cree/ Nichia/Osram) complete making all connections using 1.5 Sqmm copper conductor multistrand PVC insulated 2 core flexible cable from ceiling rose to fitting complete all as per the direction of Engr-in-charge. Note : (i) The conductor shall obtain LM 80 & LM 79 reports for the light fittings from manufactures for lot to be supplied and submit to the department. (ii) A certificate from the manufactures for warranty minimum upto 2 years shall be obtained and submitted to the AGE/GE office.
Supply & fixing 9/10 watt LED bulk head light energy saving with IP66, pressure die coast aluminum housing & ring diness & corrosion resistant, epoxy powser coated, isolated driver, CRI > 70, PF > 0.9 surge protection upto 2.0 KV, high efficacy > 100 Lm/watt. Operating voltage 170-240 volts colour temp (5700-6500)K, low heat generating LED (Make of LED shall be cree/ Nichia/Osram) complete making all connections using 1.5 Sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose to fitting complete all as per the direction of Engr-in-charge. Note : (i) The conductor shall obtain LM 80 & LM 79 reports for the light fittings from manufactures for lot to be supplied and submit to the department. (ii) A certificate from the manufactures for warranty minimum upto 2 years shall be obtained and submitted to the AGE/GE office (iii) Any touch up of the wall surface due to changing of fittings shall be done by contractors with similar surface finish without extra cost to the department.
Supply & fixing LED street light fitting 70 Watt, New generation energy saving & environmental friendly long life versatile pressure die coast aluminum IP66 and resistance IK-07 with acrylic, powder coated, pressure diecast aluminium compact High power LED street light with hear resistant toughened Glass, corrosion resistant, isolated driver, CRI > 70, PF > 0.9 surge protection upto 2.0 KV, high efficacy > 100 Lm/watt. Operating voltage 170-240 volts colour temp (5700-6500)K, low heat generating LED (Make of LED shall be cree/ Nichia/Osram) complete making all connections using 2.5 Sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose to fitting complete all as per the direction of Engr-in-charge. Note : (i) The conductor shall obtain LM 80 & LM 79 reports for the light fittings from manufactures for lot to be supplied and submit to the department. (ii) A certificate from the manufactures for warranty minimum upto 2 years shall be obtained and submitted to the AGE/GE office (iii) Any touch up of the wall surface due to changing of fittings shall be done by contractors with similar surface finish without extra cost to the department
M & L for surface mounting powder coated white CRCA full glow Led panel functional and decorative luminaries suitable for hang on BIRD type proofing LED fitting 42 watts complete with connector, block and all accessories prewired suitable size cable connection complete all as specified and as directed by Engr-in-Charge.
Supply, fixing LED flood light of 150 watt made up of pressure die cast aluminum housing with toughened glass and high power LEDs and secondary lenses with IP 66 protection& IK-07 shock protection , system efficacy not less than 110/125LPW, 10KV SPD included also available in MB/WB angle. Complete all as specified and directed by Engr-in-charge.
Supply and fixing heavy duty wall mounting, air circulation fan, 750 mm sweep , Turbo type, PSC motor equipped with pre lubricated Ball bearing, Motor should have automatic thermal overload protection, Air delivery minimum 300 m³/Min, steel body suitable hanger, counting or wall/steel structure all fixing accessories including providing as per site requirement complete and hanging the same position along with all electrical wire connection complete all as specified and directed
Supply, installation, testing & commissioning of turbo ventilator, 24 inches windy type, high corrosion resistant, maintains free, energy saving type, FRP dome thickness min 2.0mm, FRP dome assembly FRP vitrotec type, (equivalent to UV Resin type). Fan weight should be min 6kg, with 42 no of blades and blade thickness should be min 0.5mm, Top disc should be aluminum material and bearing will be ZZ double 6002, bottom ring will be Stainless steel and heavy air charge per hour (10-30) or as specified and as directed by Engr-in-charge.
Supply and fixing, water heater storage (Geyser), 25 Litres capacity, 5 star rated ,vertical type wall mounted, 230 volts, AC, 50Hz, single phase, wattage-2kw, high pressure withstand capacity 8 Bar, inner surface of storage tank should be coated with a layer of anti-corrosive material/Glass line coating/porcelain enamel coating/titanium enamel coating for extreme protection, rust proof, non-corrosive including fusible plug, digital thermostat, pressure valve, FRLS cable, poly-urethane-foam (PUF) should be min 30mm thickness, PVC connection (set of two),complete all as specified and directed by Engr-in-charge.
Supply and fixing bracket for security light fitting made of 40 mm dia light grade GI pipe, 1.2 Mtr length bent to suitable shape of fixing of security light fitting with all necessary accessories Bracket, nuts, bolts washers, two clamps made out of flat iron of size 50mmx5mmx600mm fabricated in shape and drilled holes for nuts and bolts all as specified and directed
S & F VTPN DD DB-Double Door (make –Indoasian Cat Part No. 810436), 4 way, optimum F1+12, IP-42 protection, inducing MCCB 125 Amp, 4 pole, 16 KA (make- Indoasian Cat Part no. 830023) complete all as specified and directed, including All PCC and cementing work for installation of VTPN DB To wall, deemed to be quoted rate by contractor.
Earthing complete with galvanized steel earth plate electode 600mmx 600mm x 6 mm thick electrode buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level connected to and including galvanized steel earth wire 4 mm dia by means of bolts, nuts, chock, nuts, washers of galvanized iron or steel including PCC Pit in 1:2:4 type B-1 angle iron frame with RCC cover and handle, excavation and earth work in any type of soil medium grade GI watering pipe 20 mm bore with funnel and wire mash and light grade GI protection pipe 15 mm bore upto main board complete as shown in electrical plate no 3 MES Sch 2009 (Part-I) connected to main control board as specified and testing completion complete all as specified and directed.
Earthing complete with galvanized steel earth plate electode 600mmx 600mm x 6 mm thick electrode buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level connected to and including GI strip of size 32x6 mm by means of bolts, nuts, chock, nuts, washers of galvanized iron or steel including PCC Pit in 1:2:4 type B-1 angle iron frame with RCC cover and handle, excavation and earth work in any type of soil medium grade GI watering pipe 20 mm bore with funnel and wire mash and light grade GI protection pipe 15 mm bore upto main board complete as shown in electrical plate no 3 MES Sch 2009 (Part-I) connected to main control board as specified and testing completion complete all as specified and directed.
Total amount of Sch 'A' PART-VIII ( Section-I) (LIGHTENING PROTECTION WORK)
Total amount of Sch 'A' part-IX (SITE CLEARANCE , EXCAVATION AND EARTH WORK)
SRM BUILDERS AND ENGINERS PVT.LIMITTED
SHIV CHARAN GUPTA AND SONS
Onkar Nath Bhalla And Sons Contractor Pvt. Ltd.
M/S BHATIA BUILDERS AND CONTRACTORS
TRIVENI CONSTRUCTIONS
M/s V6 Infrastructures Pvt. Ltd.
M/S KIRAN CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .