| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.9 LAccepted-AOC NO 1C CHROMPET KANCHIPURAM TAMIL NADU 600044 INDIA | CHENGALPATTU | TAMIL NADU | 600044 | L1 | Accepted-AOC AWARD OF CONTRACT | |
| 2 | L2₹52.0 L+₹4.0 L (8.43%)Rejected-Finance D 235 ADG P CHENNAI | CHENNAI | TAMIL NADU | 600001 | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹53.5 L+₹5.6 L (11.7%)Rejected-Finance 25 A BR SAMY LANE KATTOOR COIMBATORE 641009 | COIMBATORE | COIMBATORE | TAMIL NADU | 641009 | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹53.7 L+₹5.8 L (12.0%)Rejected-Finance | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | L5₹53.7 L+₹5.8 L (12.1%)Rejected-Finance 121004 | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
Refer Docs
EMD Value
₹97,000
Closing Date
27 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
PROVISION OF CERTAIN LCA WORKS AND CERTAIN MINOR WORKS AT DIFFERENT LOCATIONS AT AFS SULUR
2022_MES_535973_1
8493/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE AF SULUR
₹97,000
Yes
8 Aug 2022
5 Jul 2022
28 Jul 2022
5 Jul 2022
27 Jul 2022
20 Jul 2022
5 Jul 2022 - 15 Jul 2022
Amount
SCHEDULE A BOQ
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil, complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, taking down/laying of XLPE cable etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and as directed.
Note for Item No 2 & 3:- The quoted rate deemed to be inclusive for the following:-
(a) Excavating either straight or curved on plan
(b) Clearing away all grass vegetation, saplings, shrubs, brushwood, undergrowth, roots, and trees not exceeding 30 cm girth (measured one metre above ground level) and removing rubbish upto a distance of 50 metres outside the periphery of the area under clearance except in the case of surface dressing which includes for all the foregoing except clearing away of trees
(c) Bailing out, pumping out or otherwise removing all water which may accumulate in the excavations
(d) Setting out the work profiles, etc. as well as for all tools and plant
(e) All materials and labour required for protecting against risk of accidents, etc.
(f) Watching and lighting, whenever necessary.
(g) Forming (or leaving) ‘Dead men’ or ‘Tell tales’ in borrow pits and their removal after record of measurements where required
(h) Forming (or leaving) steps in sides of deep excavations and their removal or covering up, after record of measurements
(j) Excavation for insertion of planking and strutting where necessary
(k) Removing slips or falls in excavations
(l) Authorised battering or benching of excavations
(m) Slinging or supporting pipes, electric cables, etc. met with during excavation
M&L Plain Cement Concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and as directed.
M & L brickwork with fly ash’ bricks using old size bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and as directed
Note for Item No 18 :- (a) Fly ash bricks shall be burnt clay flyash building bricks as per IS- 13757.
(b) The rates for work curved or polygonal on plan include for all extra cutting and extra waste in the body of the work. It shall be measured as mean length of wall.
(c) Sinking of steining shall be measured separately under relevent item. Well curbs, tie-rods, etc. shall be measured under the appropriate item.
(d) bricks shall be of class designation 75 (Kgf/cm).
(e) The quoted rate shall be deemed to be inclusive for all scaffolding, ladders, plant and templates required
(f) Exposed faces of brick work shall be fair.
(g) Exposed faces shall be facing with best bricks
(h) The quoted rate shall be deemed to be inclusive for Plumbing to angles
(j) Forming reveals to jambs where fair cutting on exposed faces shall not be involved
(k) The quoted rate shall be deemed to be inclusive for preparing tops and sides of existing walls and the like for raising and extending
(l) Building in vertical seismic reinforcement at the jambs of openings, corners of walls, etc.shall be grouting in cement mortar 1:4
M&L Spreading and leveling the soils in layers not exceeding 25 cm thick in each layer including watering and well ramming complete all as specified and directed.
M&L Hardcore with broken stone or boulders of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L 75mm thick, plain cement concrete (1:3:6), type C-2 (using 40 mm graded mechanically crushed stone aggregates), as in plinth protection/ path/ hardstanding including making joints @ 3.00 metre intervals and at each corner, the joint shall be filled with mastic filling (to full depth) comprising of one part heated hot blown bitumen 85/25 & two parts heated sand (by volume), surface finished even and smooth without using extra cement complete all as specified and as directed. Note :- The concrete shall be laid at a stretch not exceeding 3 metre in length and width of joint shall not be more than 12 mm.
M&L 100 mm thick Plain cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate ) as in sub base complete all as specified and directed.
M&L 75 mm thick Reinforced cement concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregate ) as in floor and finished even and smmoth without using extra cement complete all as specified and directed. Note:- Reinforcement shall be measured and paid seperately.
M&L Rendering 15 mm thick in cement mortar 1:4 on stone masonry surfaces or surface other than fair face of brickwork or on one side of lathing, finished even and smooth without using extra cement complete all as specified and directed.
M&L applying three coats of cement based paint, including preparation of newly plastered wall surfaces of any description, complete all as specified and as directed.
Note for Item No 36:- (i)Before applying cement based paint ,the surface shall be thouroughly wetted to control surface suction. The surface shall be moist but not dripping wet when the paint applied .Surfaces which readily absorb moisture shall be wetted in one operation not more than one hour before painting.Surfaces which absorb moisture slowly shall be wtted in at least two operations not less than 30 minutes apart.
(ii)To maintain a uniform mixture and to prevent segregation ,the paint shall be stirred frequently in the bucket.
(iii)Painting surfaces shall be cured as soon as paint has hardened so as not be to damaged by the spray about 12 hours after the applications.
(iv) Cost of scaffolding required deemed to be included in the quoted rate of item and nothing extra shall be admissible on this account.
(v)Paints shall be obtained direct from approved manufacturer or from their authorized agents only and brought to site in sealed containers. The paint so procured shall be of any approved make as per list of makes specified.
Returning, filling in including spreading leveling, watering and well ramming in layers not exceeding 25cm in soft /loose soil complete all as specified and directed.
Removing excavated material to a distance exc. 1.50km but n exc. 5km and depositing where directed complete all as specified and as directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, in hard / dense soil getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed.
M&L Plain Cement Concrete 1:3:6, type C-2 (40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and as directed.
M&L Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 gradeSt.-240) complete all as specified and as directed.
S&F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F Framed work such as grills , grating ,etc with ends of bars shouldered and or reveted for forged in to spike, framed guard bars barred iron doors, ladders, balusters, walk ways raling framed work for water tanks similar work confirming to Fe -290 Gde E-165
M&L Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over one coat of red oxide primer complete all as specified and directed
M&L Preparation of new or previously untreated steel surfaces of any description, under 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over one coat of red oxide primer complete all as specified and directed
Note for item No 49 & 50 :- (a) All synthetic enamel paint shall be of 1st quality manufactured by the standard firms of make as specified.
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint, will be approved by the GE.
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)
(e ) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
(h) No hair marks from the brush or clogging of paint buddles shall be left on the work. Surface shall ordinarily not be painted until it has dried up completely. Trial patches of paint shall be laid at intervals to check if drying is satisfactory.
S&F Pre painted Coloured corrugated Galvalume roofing system sheet 0.50 mm thick having Zinc aluminum alloy coating AZ150 shall be as per IS:277/ASTM 1379 150 gsm/ sqm double ribbed trapezoidal profile steel sheet any colour having tensile strength of 550 Mpa as in Roof covering /cladding to wall fixed with self tapping screws complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Note for Item No 59 & 60 (Pre-painted coloured Galvalume roofing) :-
(i) The manufacturer's test certificate and individual test certificate for the chemical and mechanical properties of sheet must be submitted for approval by the concerned authority prior to installation.
(ii) The contractor shall ensure that no leakages take place from the roof. The roofing shall be Coloured Galvalume roofing system (olive green colour or as approved by GE) with feed material manufactured from 0.50 mm Total coated thickness (TCT), minimum 550 MPa yield strength and shall conform to the physical specifications of IS: 2062 of 2011, coated with hot dip metallic Aluminium / Zinc alloy coating AZ150 as 150 gm/sq.mt total on both sides.
(iii) The painting shall be coloured baked enamel polyester with silicon coating of film thickness 25 microns nominal on the exposed face/exterior side and on the reverse side ( interior face) shall be white with 15 microns film thickness, over a coat of 5 micron nominal thickness Primer.
S&F Galvanised wire netting, 20mm mesh size, made of galvanised steel wire of 1.40mm dia fixed with tinned tacks of wire staple complete all as specified and directed.
M&L Powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat etc complete all as specified and directed. Note: Minimum thickness of powder coating shall be 50 micron.
M&L Powder coated aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed. Note:-Glazing and particle board work shall be measured and paid seperately.
S&F 9 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to aluminium frame complete all as specified and as directed.
S&F 5.5 mm thick sheet glass, ordinary quality, ground or obscured or frosted, on one side and shapes in squares exceeding 0.5 Sq. M in each pane glazed with putty or fixed with aluminium beads complete all as specified and directed.
S & F Aluminium extruded body door closer hydraulically regulated,designation No.1, universal type, suitable for door shutters of 700 mm in width and of weight between 35 kg complete as directed by Engr-in-charge.
S&F Floor door stopper of aluminium alloy body and tongue anodized with hard drawn steel spring fixed in floor 150mm complete all as specified and as directed.
S&F Mortice lock brass 4 levers vertical type size 100mm fixed complete all as specified and as directed.
M&L for providing edge moulding to 18-20mm thick granite stone of counters vanities etc. including machine polishing to edge to give high gloss finish etc. complete all as specified and as directed.
M&L Virified Ceramic tiles 10 mm thick, light shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in vertcal surfaces such as skirting/ dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer ,15 mm thick in Cement Mortar 1:6 complete all as specified and as directed.
Note for item No 75 :- (a) Vitrified tiles are classified under group B1a of the international Standard for ceramic tiles ISO: 13006. Tiles shall be hard, dense, impervious and frost resistant. Water absorption of tiles shall be less than 0.5% and flexural strength (Modulus of Rupture) shall be more than 35 N/Sqmm.
(b) The manufacturer's test certificate for tiles must be submitted for approval by the concerned authority.
S & F 1.00 mm thick mild steel, plain black sheet in hearths covering to door shutters; covering to door chowkats (frames) chullah hoods; water tanks, water troughs,ducts, urinal troughs, and funnels, etc. cut to size edges beaded if, directed, holes punched, including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. complete all as specified and directed.
Supply, install, testing and commissioning of wall mounted star rated hi-wall split AC units indoor/outdoor of capacity 1.5 TR complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity complete all as specified and as directed. Make :- Blue star, Voltas, Hitachi
S&F XLPE insulated, screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 25 Sqmm 3 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, taking down existing cable etc all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : KEI/ Havells/ Polycab
M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC conduit and all accessories fixed to wall/floors along with 1 run of 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and directed. Note: (a) 2 runs of 6 sqmm cable along with 1 runs of 6 sqmm cable for earth conductor and PVC conduit shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. (c) The quoted rate is deemed to be inclusive for cutting through walls for concealed wiring and making the surface good as directed by Engr-in-Charge. Make:- Havells/ Polycab/ Plaza.
S&F factory made powder coated distribution board VTPN, 4 way double door including 200 Amp rated tinned copper bus bar for mounting MCBs, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS: 8623 & IP 43 complete all as specified and as directed. Make:- Legrand/ Siemens/ Schnieder/ L&T
Supply and fixing single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 complete all as specified and as directed Make/Model :- Legrand Cat Part No 408587 to 408595 or equivalent. of Schnieder, Siemens.
Supply and fix 25mm bore, high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm fixed to wall, floor etc for drain out the condensed water complete all as specified and as directed by Engineer-in-Charge
Supply and fix metal clad switch socket single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A concealed in walls complete all as specified and directed. Make : Legrand or equivalent of Schnieder (Multi -9) or Siemens/L&T (Hegar)
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of +/- 2.5% and of capaciy 4 KVA complete all as specified and as directed. Make - V-Guard Model No VG 400 or equivalent in Microtek/ AE
S&F MCCB, 4 Pole, 100 Amps, Thermal Magnetic Release adjustable type, 415 Volt, 16 KA including connecting up using suitable size of copper lugs complete all as specified and as directed. Make : L&T, Legrand, Siemens
S&F MCCB, 4 Pole, 63 Amps, Thermal Magnetic Release adjustable type, 415 Volt, 16 KA including connecting up using suitable size of copper lugs complete all as specified and as directed. Make : L&T, Legrand, Siemens
Removing excavated materials not exceeding 50m distance and depositing where directed at level not exceeding 1.5 m above the starting point complete all as per specified and as directed.
S&F Fly ash bricks using old size bricks as in cable protection cover including taking down existing bricks of any size complete all as per specified and as directed.
Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming complete all as per specified and as directed. Note :- In case sufficient sand not obtained from excavation, the rate is deemed to be inclusive for additional qty of sand required to be obtain from out side MD land as directed by the Engineer-in-Charge.
Supply and fix GI pipe 40 mm bore light grade for cable protection complete all as specified and as dierced by Engr-in-Charge. Make : Tata, Jindal, Surya Prakash
Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 32 x 6mm by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, magnesium sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in in any type of Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down existing one complete all as per specified and as directed by Engineer-in-Charge.
Note for Item 93 :- (a) All Joints should be joined by Exothermic Welding or Brazing.
(b) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained.
(c) Earth resistance tester shall be provided by the contractor. It should be caliberated from authorised company/ lab.
(d) After testing if desired earth resistance of less than 5 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained.
Supply,errect, test and commissioning of Air shower cabinet made out of IS 304 Graded stainless stell with following specifications :- (a) Capacity - 2 Persons per cycle (b) Internal dimensions - W 900 x D 900 x H 950 mm (c) External dimensions - W 1600 x D 1000 x H 2200 mm (d) Entry & Exit Door Size - W 750 x H 1800 mm (e) Lighting - LED lighting : 1 No (f) Nozzles - Stainless, fixed - 14 Nos (g) Nozzle position - Right, Left, Top (h) Air Velocity - 24 METERS / SECOND 2 (j) Air balancing - 100% Recirculation (k) Version - Straight Entry & Straight Exit (l) Cleanliness - CLASS 10000, (ISO CLASS 7) for particle sizes 0.5 micron & above (m) Shower duration - 0 to 120 seconds - Adjustable (n) Blower - Outer rotor type centrifugal blower with high air volume displacement, 3 phase, 415 Volt (o) Power supply - 415/ 440 Vol, 3 phase, 50 Hz Make :- Cleanair Air Shower Entry system Model No:- CAS 0900, or equivalent make.
(p) MOC : Complete cabinet fabricated by using IS 304 grade stainless steel sheets of 1.2 mm thick. (q) Doors - Entry & Exit Doors by made of IS 304 respectively, glassed view panel, automatic door closures, electromagnetic interlocking & SS Handle (r) Type of HEPA Filter - International standard Mini pleat type HEPA filter, made of ultra clean glass fiber paper media of imported origin, assembled in anodized aluminum frame. Particle retention 0.3 micron, Efficiency 99.997%, initial pressure drop 16mm WC. (s) Type of Return Air Filter : Made of Synthetic non-woven polyester fibers with fine HDPE mesh reinforcement. Particle retention 10 micron, efficiency 90%, initial pressure drop 6mm WC. (t) Control : Interlocking By Electromagnets Overload protection by thermal relay Shower duration by adjustable electronic timer 0 to 120 seconds. Shower operation - LCD based fully automatic circuitry system
Note for Item No 98 :- (a) The unit quoted rate shall be included the cost of AMC for smooth functioning of the above mentioned system for 24 months. An amount 10% of quoted rate shall be withheld towards guarantee for a period of 24 months from the date of completion
(b) During this maintenance period, company Engineer will carry out periodical servicing and preventive maintenance at least once in 180 days or whenever breakdown occurs irrespective of numbers.
(c) During maintenance period, if he fails to do so, the Accepting Officer has all the right to recover the cost incurred to make the system functional from the contractor, the way it deems appropriate
M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC conduit/ casing and capping and all accessories fixed to wall/floors along with 1 run of 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and directed. Note: (a) 2 runs of 4 sqmm cable along with 1 runs of 4 sqmm cable for earth conductor and PVC conduit/ casing and capping shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
Supply and fix metal clad switch socket single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A concealed in walls complete all as specified and directed. Make : Legrand or equivalent of Schnieder (Multi -9) or Siemens/L&T (Hegar)
Supply and fixing on distribution boards, single pole MCB 10 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 complete all as specified and as directed. (Make/Model : Lexic MCB of MDS Legrand Cat No : 408590 to 408595 or equivalent. of Schnieder Siemens/L&T
S&F Wiring complete with 1.5 sqmm single core PVC insulated, unsheathed FRLS 1100 volts grade,FRLS cable and incl PVC Casing Capping with accessories in wall/roof/ceiling/hangar steel frames etc incl Modular terminal boxes fabricated with 1.6mm MS sheet concealed/fixed surface to walls covered with modular white cover plate with frame etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 106 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Supply and Fix modular switch 1 way 6 amp.1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply and Fix modular switch 1 way 16 amp.1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply and Fix modular Socket, 6A - 2/3 pin combined 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply and Fix modular Socket, 6/16A - 2/3 pin combined 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply and Fix moduler white cover plate with frame,3 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
S&F metal flush box 3 module complete all as specified and as directed.
Supply and fix detectors complying with and type certified to EN-45 Addressable type smoke detector Photoelectric /Optical with base with self built intelligence as per IS:11360 complete all as specified and directed.
Supply and fix addressable manual call point annunciating device resettable type complete all as specified and directed.
Supply and fix fire alarm control panel complying with BS EN 54 Single loop panel of capacity from 99 detectors & 99 modules upto 200 detector and modules complete all as specified and directed.
Supply and fix addressable sounder annunciating device complete all as specified and directed
Supply installation and commissioning of 2 Core, 2.5 sqmm twisted pair shielded cable for FACP conductivity suitable for fire survival including metallic rigid steel conduit not less than 20mm dia complete with all accessories such as bends, tees, bell mouth, check nut, straight joint, L bend etc complete all as specified and directed
T C KARUNANITHI
rvelectricals
NAVEEN ENTERPRISES
Neptune Engineers and Builders
kaarthic builders
D.R ASSOCIATES
Lucky Enterprises
devan enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .