GE(I)(CG)KOCHI BUILDING NO.22/2614, OPP. SANTHOM CHURCH MUNDAMVELI POST RAMESWARAM KOCHI-682 507
REPAIRS MAINTENANCE TO ACs, WATER COOLERS, WATER PURIFIERS UNDER AGE B R NEW MANGALORE
2020_MES_314790_2
GE/CG/8687
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
Mangalore
AS PER NIT/TENDER DOCUMENTS
8 documents required · 8 mandatory
₹300
GE(I)(CG)KOCHI
₹9,800
Yes
27 Apr 2020
14 Mar 2020
28 Mar 2020
14 Mar 2020
27 Mar 2020
15 Mar 2020
14 Mar 2020 - 15 Mar 2020
Amount
Material and Labour for servicing of split type AC unit of any capacity/any make by removing dust with suitable method, cleaning of air filters, tightening of loose wire, nuts, bolts, washers, servicing of condenser motor/ blower, by oiling, greasing, required welding/bracing, replacement of worn out rubber bushes of condensor motor, setting of grill alignment & knobs, Checking for any leakages, provision of thermocoal for air tightness, testing etc all as specified and directed.
Material and Labour for painting the outdoor unit of split AC of any capacity/any make and its stand by synthetic enamel spray paint as existing colour and writing MES No all as specified and directed.
Removing the unserviceable blower motor from the Split AC 1.5/2 Ton unit and M&L for rewinding of blower motor, single phase, with super enamelled copper wire of existing gauge including replacement of gunmetal bush of suitable size, cleaning, greasing and refixing of motor, connecting up all including testing and refixing complete all as specified and directed.
Supply and fix in replacement blower motor 1/10 HP, 1350 RPM suitable for Split type AC 1.5/2 Ton out door unit single ended or double ended shaft as per existing one complete all as specified and as directed. Make: AUE/ Marathon Electric or equivalent
Removing the unserviceable compressor from Split type AC and supply and fix new compressor suitable for 1.5 Ton split type A/C all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capacity tube and strainer/filter and painting of base plate complete all as per existing one and as directed by Engr-in-Charge. Make : Kirloskar/Mitsubhishi/Bluestar/Tecumseh or equivalent
Removing the unserviceable compressor from Split type AC and supply and fix new compressor suitable for 2 Ton split type A/C all including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capacity tube and strainer/filter and painting of base plate complete all as per existing one and as directed by Engr-in-Charge. Make : Kirloskar/Mitsubhishi/Bluestar/Tecumseh/Voltas or equivalent
Supply and fix in repairs copper piping (suction and discharge) and power cable including the thermal insulation all as directed by Engr in charge.
Supply and fix drain pump suitable for casssette type Split AC 2 TR including taking down the defective drain pump complete all as specified and as directed. Make: Bluestar/Voltas/Godrej
Supply and fix in repair indoor cooling coil made up of copper tubing and copper/aluminium cooling fins all as per sample and as suitable for 1.5/2 Ton capacity split type AC all as specified and directed by engr in charge.
Supply and fix in repair condenser coil made up of copper tubing and copper/aluminium cooling fins all as per sample and as suitable for 1.5/2 Ton capacity split type AC all as specified and directed by engr in charge.
Supply and fix in repairs room sensor all as per existing one and suitable for 1.5/2 Ton capacity split AC complete all as specified and as directed. Make : Bluestar/ LG/Voltas
Supply and fix in repairs running capacitor 60 Mfd 440 V AC suitable for 1.5/2 Ton capacity AC complete all as specified and as directed. Make : KELTRON/BHEL/KEL/TESLA/SYSCAP
Supply and fix in repairs capacitor 6 Mfd 440 Volts suitable for condenser motor of 1.5/2 Ton A/C capacity complete all as specified and as directed. Make : Renutral / Shriram/Usha/Keltron
Supply and fix in repairs coil sensor all as per existing one and suitable for 1.5/2 Ton capacity split AC complete all as specified and as directed. Make : Bluestar/ LG/ Carrier
Supply and fix in repairs condensor fan blade all as per existing one and suitable for 1.5/2 Ton capacity split AC complete all as specified and as directed. Make : Bluestar/ LG/ Carrier
Supply and fix in repairs sheet metal enclosure , single pole neutral, with two pin and earth plug top and socket complete with one no of MCB SP, 20 A, 240 V complete all as specified and as directed.
Tracing out leakage from suction line, discharge line, evaporation condenser, filter, capillary tube by suitable method including bracing, welding, replacement of filter strainer charging line and filling of gas charging (R-134 A) aprox 0.75 Kg or prussure as prescribed by manufacturer, leak testing & commissioning of Split type A/C of any type, any capacity, any make complete as directed by Engineer-in-Charge.
Supply and fix in repairs electronic circuit complete including controlling unit (ie Remote) all as per existing one and suitable for 1.5/2 Ton A/C complete all as specified and as directed. Make panasonic,Blue Star, Videocon, LG
Supply and fix in repairs printed circuit board (PCB) complete including controlling unit (ie Remote) all as per existing one and suitable for 2 TR cassette type Split AC complete all as specified and as directed. Make: Voltas/LG/Blue Star
Supply and fix in repairs receiver PCB complete including the chords suitable for 1.5/2 TR Split AC all as per existing one complete all as specified and as directed. Make: Blue Star / LG / Voltas
Removing the unserviceable condenser fan motor from the Water cooler of 40/120 Ltr capacity and Material and Labour for rewinding of condenser fan motor of capacity 1/30 or 1/32 HP 1350 RPM single phase, with super enamelled copper wire of existing gauge including replacement of gunmetal bush, cleaning, greasing and refixing of motor, connecting up all including testing and refixing complete all as specified and directed.
Removing unserviceable condenser fan motor from the water cooler of any capacity and supply and fix in replacement new condenser fan motor 230 V, 50 HZ as per sample existing suitable for 40/120 Ltr capacity storage type water cooper complete all as specified and directed. Make : Marathon Electric / AUE
Removing the unserviceable compressor from water cooler and supply and fix new compressor suitable for 120 Ltr capacity of water cooler including fixing in original position, connecting up, testing, gas charging, pressure testing, cleaning of cooling coils necesary welding/ brazing and including required capillary tube complete all as specified and directed. Make : Kirloskar/Tecumshe
Supply and fix in repairs starting relay for 40/120 Ltr capacity water cooler including over load protector complete assembly complete all as specified and as directed. Make : KIRLOSKAR,INDFOSS /USHA/BLUESTAR
Tracing out leakage from suction line, discharge line, evaporation condenser, filter, capillary tube by suitable method including bracing, welding, replacement of filter strainer charging line and filling of gas charging (R-134 A) aprox 0.75 Kg or prussure as prescribed by manufacturer, leak testing & commissioning for water cooler 40/120 Ltr storage capacity, any type, any make all complete as specified and directed by Engineer-in-Charge.
Material and Labour for Servicing and cleaning of the water cooler 40/80/120 Ltr capacity by removing dust with suitable method, cleaning of water tank, inlet and outlets including leak proofing/ repairing of storage tank, necessary repairs to wiring of the water cooler unit ie, internal wiring connections to compressor, condenser motor etc., supply and replacement of damaged hinges, nuts, bolts, clamps, washers, screws, tightening of loose parts, servicing of condenser motor by oiling, greasing, required welding/bracing to the any part of the water cooler, repairs to chromium plated drain tray, replacement of worn out mounting rubber bushes of condenser motor/compressor, setting of thermostat, relay, knobs, checking for any leakages, scrap out rust and dust from body of water cooler complete all as directed by Engineer-in-Charge.
Material and Labour for Cutting, removing the old, rusted base angle iron frame and MS sheets not exc 0.30 M high of chasses cabinet and S&F angle iron and required MS sheet 2 mm thick suitable to the base of storage type water cooler body of 40/80/120 Ltr capacity all including cutting, welding, bending, shaping, grinding, drilling and making good, supply and fixing of nuts, bolts, washers as per requirement and Painting of Complete water cooler unit including compressor, condenser motor with one coat of red oxide primer and two coats of synthetic enamel paint as per existing colour all as directed by Engineer-in-Charge.
Supply and fix in repairs running capacitor 36 Mfd, suitable for 120 Ltr capacity water cooler complete all as specified and as directed. Make : USHA/SRIRAM/KELTRON/Syscap
Supply and fix in repairs running capacitor 10 Mfd, suitable for 40 Ltr capacity water cooler complete all as specified and as directed. Make : USHA/SRIRAM/KELTRON/Syscap
Supply and fix in repairs chromium plated push/lifting cock, 15 mm, made up of brass and suitable for 40/80/120 Ltr capacity storage type water cooler as per existing sample complete all as specified and as directed. Make : JOHNSON/COSMA/ARK
Supply and fix in repairs thermostat including knob, plate, screws suitable for 40/150 Ltr capacity water cooler complete all as specified and as directed. Make : USHA / Shriram / Blue star/Indfoss / Jhonson/Renutral
Supply and fix in repairs PVC drain pipe 1.5 Mtr Long of 25 mm dia for water cooler complete with clamp, screws etc complete to drain water from drain tray of water cooler as per existing sample complete all as specified and as directed.
Supply and fix in repairs float valve with polythene PVC ball of 15 mm (1/2") bore size suitable for 40/120 Ltr capacity water coolers as per existing sample complete all as specified and as directed. Make:Prayag/Hindware/Parryware
Supply and fix in repairs prefilter of water purifier AG 200 complete all as specified and as directed. Make: Aquaguard or equivalent in Kent/Tata/Whirlpool
Supply and fix in repairs Carbon filter of water purifier complete all as specified and as directed. Make: Aquaguard or equivalent in Kent/Tata/Whirlpool
Supply and fix in repairs solenoid valve for water purifier AG 200 complete all as specified and as directed. Make : Aquagurad or equivalent in Kent/Tata/Whirlpool
Supply and fix in repairs printed circuit board for water purifier AG 200 complete all as specified and as directed. Make : Aquagurad or equivalent in Kent/Tata/Whirlpool
Supply and fix in repairs UV lamp for water purifier AG 200 complete all as specified and as directed. Make : Aquagurad or equivalent in Kent/Tata/Whirlpool
Supply and fix in repairs UV sensor for water purifier AG 200 complete all as specified and as directed. Make : Aquagurad or equivalent in Kent/Tata/Whirlpool
Supply and fix in repairs UV+UF water purifier with purification capacity of minimum 60 ltr/hr single phase, 250V, AC, 50H, sediment activated carbon filter catridge complete with necessary arrangement for waste water after purification process all as specified and directed by Engr-in-charge. Note:Old purifier shall be deposited to MES store. Make:Dr.Aqua guard Classic plus or Equivalent in Kent as approved by Accepting Officer
Supply and fix in repairs flexible hose of purifier 15mm bore which connects prefilter to Water purifier incluidng necessary washers,screws etc complete all as specified and as directed.
Supply and fix in repairs toggle switch suitable of purifier complete all as specified and as directed.
Supply and fix in repairs air drier bottle of best water doctor water cooler complete all as specified and as directed.
Material and Labour for servicing and repairs to voltage stabilizer of capacity 4KVA/5KVA of any type including checking the PCB control board,suitable 220/240V transformer, replacement of time delay relay, indicator lamps socket combination 5/15 Amps, plug tops, cut outs to rectify the defects all as directed. Note: Spares shall be measured and paid separately under appropriate items unless otherwise specified.
Supply only PCB of voltage stabilizer of capacity 4 KVA complete all as specified and as directed.
Supply only PCB of voltage stabilizer of capacity 5 KVA complete all as specified and as directed.
Supply only single phase 220/240 Volts transformer for 4/5 KVA voltage stabilizer complete all as specified and as directed.
Supply and fix in repairs MCB 4 pole 415V, 10 kA, 63A capacity, C curve complete all as specified and as directed.
Supply and fix in repair AC outdoor stand complete all as specified and as directed.
Schedule of Credit (Minus) Rs. 19600.00 NOTE: Bidder shall insert credit amount of Rs. 19600.00 as rate in Green field under Col-13.
Jack Electrolinks Private Limited
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .