SE OAND MC II BTPS ANPARA
OFFICE OF SE O AND MC II BTPS ANPARA
Overhauling Maintenance of HP LP Valves of Turbine side of 2X500 MW B TPS
2020_RVUNL_508977_1
06/TMD/BTPS/2020-2021
Open Tender
Miscellaneous Works
Fixed-rate
365 days
ANPARA THERMAL POWER PROJECT ANPARA SONEBHADRA
AS PER TENDER PQC
2 documents required · 2 mandatory
₹590
DY CAO CFA AND BO BTPS ANPARA SONEBHADRA
₹36,000
2 Nov 2020
10 Sept 2020
21 Oct 2020
10 Sept 2020
19 Oct 2020
10 Sept 2020
10 Sept 2020 - 19 Oct 2020
Amount
Servicing of motor operated M-BFP discharge isolation valves, control & isolating valves on feed water lines, Ist/IInd discharge NRVs of M-BFP, manually operated gate/globe valves installed of HP lines on Turbine side. Size: 250~300mm, Design press.: > 40 Kg/cm2, temp.: 250 oC
Servicing of motor operated discharge isolation valve, Ist / IInd. discharge NRVs of T-BFPs, control & isolating valves on feed water lines. Size:350 mm, Design press.: 219~302 Kg/cm2, temp.:210 oC
Servicing of feed water minimum flow isolation valves, pneumatically operated control valves on Turbine side. Size:150 mm, Pr. : 219~224 Kg/cm2
Servicing of motor operated control valve, motor operated gate/globe valves, manually operated gate/globe valves, check valves Size:150~250 mm & manually operated valves of Size: 15~100mm installed on HP lines. motor operated valves. Size: 25~100 mm Pr.> 40 Kg/cm2
Servicing of hydraulic operated HP Bypass spray water control valves, spray isolation valves, NRVs on Turbine side. Size:100-150mm, Pr. : 152 Kg/cm2.
Servicing of HPH 5A, 5B, 6A, 6B Extraction steam valve, check valves. Size: 250mm, Pr.: 40~51Kg/cm2
Servicing/Overhauling of CRH reverse current valve. Size:900mm, Pr:51 Kg/cm2
Replacement of HP / LP valves of different Floors by cutting of damaged valve & welding of new valve. Size: 08~25 mm.
Replacement of flange gasket of HP/LP valves & piping on per mm dia.basis of valve.
Replacement of gland packing with new one of HP / LP Valves on per mm dia. basis of valve.
Replacement of HP / LP Heater man hole flange gasket.
Servicing of HPH - 5A/5B, 6A/6B, LPH-2&3, deaerator & Gland steam header safety valve.
Servicing of suction relief valves of T-BFPs / M-BFPs / CEPs / LPHs / HPHs and safety valves of main air ejectors.
Servicing of motor operated/control & isolation valves installed on LP lines. Size: 25~100mm, Pr. <40 Kg/cm2.
Servicing of motor operated / control & isolation valves installed on LP lines. Size: 150~200mm, Press<40 Kg/cm2.
Servicing of motor operated/control & isolation valves installed on LP lines. Size: 250~650 mm, Press<40 Kg/cm2.
Servicing of mannual operated gate/globe valves & NRVs installed on LP lines. Size: 15~100mm, Pr. <40 Kg/cm2.
Servicing of mannual operated gate/ globe valves & NRVs installed on LP lines. Size:150~350mm, Press<40 Kg/cm2.
Servicing of mannual operated gate/ globe valves & NRVs installed on LP lines. Size: 400~650mm, Press < 40 Kg/cm2.
Servicing of steam drain trap valve. Size: 40~50mm, Pr. < 40Kg/cm2.
Revisioning/ Servicing of Butterfly valves installed on ACW System & Gland steam system.Size:150~350mm.
Revisioning / Servicing of Butterfly valves of ACW System. Size: 450~750mm
Revisioning / Servicing of NRVs installed on ACW System. Size: 500mm.
Revisioning / Servicing of NRVs installed on SRW System. Size: 750mm.
Servicing of gear boxes of various valves installed on ACW System, feed water, condensate & steam line. Valve Size: 100~750 mm.
Servicing of gear boxes of various valves provided at condenser inlet & outlet in CW line and BFP-T exhaust to condenser. Valve Size: 1350-2100 mm.
Revisioning/Servicing of butterfly valves of BFP-T exhaust to condenser. Size:1350 mm.
Revisioning/Servicing of butterfly valves provided at condenser inlet & outlet in circulating water line. Size:2100 mm.
Welding/repair of LP pipings attending leakages of pipe lines & headers etc. by cutting the damaged portions.
Revisioning / Servicing of Ventilator valve.
Replacement of flange type gate/globe valves of M-BFP & T-BFP oil coolers / LP lines Size: 80 -100 mm
Replacement of butt welded gate/globe valves of M-BFP & T-BFP oil coolers/LP lines Size: 80-100 mm
Revisioning/Servicing of NRVs installed on sump pump pipe lines on Turbine side. Size: 50-100 mm.
Revisioning / Servicing of Ball Collector of Condenser Tube Cleaning System.
Inspection/minor repairing of ball catch strainer of condenser tube cleaning system installed inside CW return line of size:2100 mm
Revisioning/Servicing of ball type valves installed on condenser tube cleaning system on Turbine side. Size:15-40 mm.
Revisioning/Servicing of ball type valves installed on condenser tube cleaning system on Turbine side. Size: 65 -100 mm.
Inside inspection and minor repairing of HP/LP Flash Tanks.
Inspection/Repairing of nozzle of starting air ejector.
Replacement of HP / LP valves of different Floors by cutting of damaged valve & welding of new valve. Size: 40~65 mm.
Inspection and O/H of nozzles of Steam Jet Air Ejector.
Inside inspetion of CW outlet duct by opening of its manhole
Revisioning / Servicing of HP Heater Bypass Valve BF-031-EGV
Revisioning / Servicing of Isolating valve for Superheater spray water SP-031-MGV
M/S BIHAR CONSTRUCTION CO.
M/S S N ENTERPRISES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .