Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.6 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹16.1 L+₹1.4 L (9.54%)Rejected-Finance | L2 | Rejected-Finance BEING OTHER THAN LOWEST BIDDER |
Tender Value
₹19.1 L
EMD Value
₹32,180
Closing Date
22 Nov 2023, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Leh
GE (AF) Leh PIN - 194101
PROVN OF CERTAIN MINOR AND REVENUE WORK OF B/R NATURE AND INTERAL ELECTRIC WORK AT DSS HUT AT AF STN LEH UNDER GE (AF) LEH
2023_MES_610852_3
GE (AF)/LEH/T-39/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Leh
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Leh
₹32,180
Yes
25 Jan 2024
26 Oct 2023
25 Nov 2023
26 Oct 2023
22 Nov 2023
3 Nov 2023
Amount
M&L for solar control film 50 micron reflactive type sticked to glass panes as per instructions of manufacturers complete all as specified and directed.
Excavation in trenches in soft/loose soil not exc 1.5 m wide and not exc 1.5 m depth for foundation, shaft, well, cesspits, manhole, pier holes etc n. exc. 10 Sqm on plan , and getting out complete all as directed by the Engineer–in–charge.
Surface excavation in soft/loose soil not exc 30 cm deep and averaging 15 cm deep and getting out complete all as directed by the Engineer–in–charge.
Returning, filling in incl spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft /loose soil, complete all as specified and directed by Engrineer-in-Charge.
Removing excavated material in soils n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engrineer-in-Charge.
Plain cement concrete (1:4:8), type D-2, using 40 mm graded mechanically crushed stone aggregates as in sub base to floor /Sunken floor/paving ,foundations, filling and mass concrete,complete all as specified and directed by the Engineer in Charge.
Plain cement concrete ,100 mm thick (1:2:4) type B-2, using 40 mm graded mechanically crushed stone aggregatesd aggregate as in sub base to floors complete all as specified and directed by the Engineer in Charge.
M&L Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar, completeType C1 1:3:6 (20mm graded aggregate)Set in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge
Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished fair and even , complete all as specified and directed by Engineer-in-Charge.
First quality glazed ceramic coloured tiles of 300x200x7 mm thick, laid on vertical surfaces such as skirting, dados and risers to steps etc laid over and including 10mm thick cement plaster in CM (1:3) set and jointed in neat cement paster , complete all as specified and directed by the Engineer in Charge.
Machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including screed bed or bedding layer of mortar 20 mm thick for laying floor finishes in Cement plaster 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by the Engineer in Charge.
Pre–painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.47mm to 0.50 mm of an colour having tensile strength of 550Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and as directed by the Engineer-in-Charge.
M&L 2nd class soft-wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered,put together with glue pinned at joints, supplied and fixed in 2nd class soft-wood, complete all as specified and directed by Engineer-in-Charge
M&L 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, complete all as specified and directed by Engineer-in-Charge
M&L 30 mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats in 2nd class soft-wood, complete all as specified and directed by Engineer-in-Charge
M&L 4.8 mm Sheet glass,ordinary quality and glazing in square n exc 0.5 sq. m in each pane, complete all as specified and directed by Engineer-in-Charge
S&F 250 mm Aluminium alloy, anodised,sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and directed by Engineer-in-Charge
S&F 100 mm Butt hinges, medium weight, cold rolled mild steel, and fixed, complete all as specified and directed by Engineer-in-Charge
S&F 100 mm Aluminium anodised,barrel tower bolts of ex truded section and fixed, complete all as specified and directed by Engineer-in-Charge
M&L type B–1, 1:2:4 (20mm graded crushed stone aggregate) providing RCC precast cement concrete as in cover slab for man hole and similar article with plain face set in cement mortar 1:4 complete all as specified and directed.
M&L for TMT Mild steel bars 6 To 8 mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engrineer-in-Charge.
Supplying and laying of PVC pipe, 150mm dia heavy duty including jointing with coppler complete laid in trenches or floors complete all as specified and directed by Engrineer-in-Charge. Make : Finolex, Supreme, Kisan, Prince
Cutting hole in brick walls built in cement mortar for inserting holdfast and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required depth of embeded portion of hold fast lugs measured from the face of the jambs in the wall exc. half brick but not exc one brick complete all as specified and directed by Engrineer-in-Charge
Framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering Door etc to be prepared for hanging or sliding with and including either hooks and hinges door fitting (exclusive of steel sheeting or other covering running rails and guides) and hanging also fastering and fixing complete.
Preparation of new steel surfaces of any description exceeding 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge
First quality glazed ceramic coloured tiles of 300x450x7 mm thick, laid on vertical surfaces such as skirting, dados and risers to steps etc laid over and including 10mm thick cement plaster in CM (1:3) set and jointed in neat cement paste of honey like consistancy and pointed in white or coloured cement to match the shade of tiles in and includingtaking down cement plaster and removing rubbish off the premises, complete all as specified and directed by the Engineer in Charge.
S & F mild steel framed work such as grills, grating, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing, frame work of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed.
Excavation in post holes (or similar holes) each not exc. 0.50 cum, in any type of soil and getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exc. 25cm, watering and removal of excavated materials to a distance n. exc. 50m and making good surfaces, complete all as specified & directed.
Plain cement concrete (1:3:6), type C-2, using 40 mm graded mechanically crushed stone aggregates as in sub base ,foundations, filling and mass concrete, complete all as specified and directed by the Engineer in Charge.
Rolled mild steel sections as in column main and joist, channel, angle, or tee sections, fixed independently etc. (cut to ordinary lengths i.e. within 20mm of the length indicated, fixed with angle cleats or other connecting plates of Fe 410-W (Gde E-250) quality-A in and including dismantling of structural steel , complete all as specified and directed by Engineer-in-Charge
S & F mild steel sheet 1.25 mm thick plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched, including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles etc., as required complete all as specified and directed
Mild steel rolled section as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastening and heavy bracket framing (Beam, tee, angle, channel or flat sections) incl distance pieces, cleats etc. confirming to grade Fe-290. Gde- E-165. complete all as specifed and directed.
Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface with broken stone complete all as specified.
Plain cement concrete ,100 mm thick (1:4:8) type B-2, using 40 mm graded mechanically crushed stone aggregatesd aggregate as in sub base complete all as specified and directed by the Engineer in Charge.
Taking down Shutters of any description n.exc 1 sq. m each, complete all as specified and directed by Engineer-in-Charge
Taking down Shutters of any description exc 1 sq. m and n exc 2 sq. m each, complete all as specified and directed by Engineer-in-Charge
Dismantling timber scantlings under 40 sqcm and over in section, as in fillets, rails, rafters, purlins etc unframed work complete all as specified and directed.
Dismantling wooden fillet rails, posts, rafters, purlins etc. (framed work) under 40 sqcm in section complete all as specified and directed.
Taking out old unserviceable glass of any description from old wooden or metal frame or stone concrete or brick surrounding any thickness or size hacking out out putty or removing beads etc. including making good breakage in taking out and handling removing to store or staking for reuse.
M & L rolled mild steel section as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates etc.
M&L Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar, completeType C1 1:3:6 (20mm graded aggregate)Set in cement mortar 1:6 including demolition of brick work or stone/ bouldar masonry built in cement mortar or cement line mortar including all quoins, achers, pillars etc but excluding ashlar facing dressed stone work and precast concrete article complete all as specified and directed by Engineer-in-Charge
M & L for preparation of new plasterd surface of walls and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004, Alkali and fungal resistance, dirt resistance exterior paint of 100% required shade (Company Depot tinted) in Camouflage pattern with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.50 litre/10 sqm over new surfaces complete all as specified and directed
M & L for Non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over screed bed or bedding layer of mortar 15 mm thick of cement plaster (1:4) including dismantling of floor, herth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish of the premises complete all as specified & directed.
First quality glazed ceramic coloured tiles of 350x250x7 mm thick, laid on vertical surfaces such as skirting, dados and risers to steps etc laid over and including 10mm thick cement plaster in CM (1:3) set and jointed in neat cement paster including dismantling of floor, herth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish of the premises complete all as specified & directed.
Providing and fixing false ceiling with semi perforated 12mm thick micro regular edged GRG false ceiling tiles at all height with GRG (Glass fgiber reinforced Gypsum) false ceiling tiles of size 595x595mm of approved texure, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRCO .50 as per IS 8225: 1987, Non combustible as per BS 476(Part 4)-1970 and light relectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @120 grams per sqm including both sides) comprising of maint runners of size 15x32mm of length 3000mm, cross T of size 15*32mm of length 1200mm and secondary intermediate cross T of size 15*32mm of length 600mm to form grid module of size 600*600mm, suspended from ceiling using galvanized mild steel items (galvanized @80 grams per sqm) i.e. 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85x25x2mm Galvanized iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on periphery wall/ partition with the help of plastic rawl plugs at 450mm center to center and 40mm long dry wall wood screws including dismantling of wall and ceiling boards (fibre, pulp, insulation etc.) or insulation boards/ slabs/ blankets, any thickness including cover fillets. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.
Pre–painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.47mm to 0.50 mm of an colour having tensile strength of 550Mpa as in roof covering /cladding to wall, fixed with self tapping screws in and including dismantling of plain or corrugated steel sheeting any gauge, thickness,including nanital or similar pattern roof covering, complete all as specified and as directed by the Engineer-in-Charge.
S&F for pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified including dismantling of plain or corrugated steel sheeting and gauge, thickness, any pattern complete all as specified and directed.
S&F Powder coated aluminium (min thickness of powder coating 50 micron) work for doors, windows, ventilators and partition (Fixed portions) with extruded built up standard tubler sections/ appropriate Z sections and other ssections of approved make conforming to IS:733 and IS:1258, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium section shall be smooth, rust free, straigh , mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/ paneling, C.P. brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.
Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows and ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever require including the cost of EPDM rubber/neoprene gasket required (fittings shall be paid for separately) with extruded built up sandard tubular sections/ Appropriate Z section and other section of approved make confirming to IS-733 and IS-1285, fixing with dash fasteners of required dia and size, including necessary filling up to gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber, neoprene gasket etc aluminium section shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium smap beading for glazing, panelling, CP brass/ Stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-Charge.
Galvanised mild steel wire cloth 0.63 mm nominal dia of wire and avarage width of aparture 1.40mm and fixed etc complete all as specified.
Sheet glass ordinary quality 4.8 mm thick n.exc 0.50 sqm each for fixing with all necessary fixing arrangement all as specifieid and as directed.
Sheet glass ordinary quality 4.8 mm thick exc 0.50 sqm each for fixing with all necessary fixing arrangement all as specifieid and as directed.
Aluminium anodised barrel tower bolts, 200 mm long of extruded section complete all as specified and directed.
Aluminium anodised barrel tower bolts, 100 mm long of extruded section complete all as specified and directed.
Aluminium anodised handles, cast type anodised 150 mm long complete all as specified and directed.
Aluminium anodised handles, cast type anodised 100 mm long complete all as specified and directed.
M&L 12m thick prelaminted particle board exterior grade, prelaminated both sides with decorative choice lamination fixed
S&F door closer hydraulically regulated designation No 3 universal type suitable for door shutter of 851 to 1000 mm in width and of weights between 80 Kg (aluminium Die cast) Body completed all as specified.
S&F for window roller blinds & curtains with fabrics and design of sample aproved by GE with and including Top holding brackets, roller chain pull/ lifting arrangements as per manufactures instructions complete all as specified and directed by Engineer-in-Charge.
Plain cement concrete, 75 mm thick (1:4:8) type B-2, using 40 mm graded mechanically crushed stone aggregatesd aggregate as in sub base complete all as specified and directed by the Engineer in Charge.
M&L for chequered cement concrete tiles 20cmx20cmx25mm thick , set jointed and pointed in neat cement slurry in floor including screed bed or bedding layer of cement mortar 1:4, 20mm thick for laying floor finishes including dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar.
Taking down carefully copper/Aluminium point wiring (Light,fan,socket or power) complete including fitting such as switches, socket, bell pushes, ceiling roses, pendants/batten holder, call bell, regulators etc, complete all as specified and directed by Engineer-in-Charge.
Point wiring for one light/fan point controlled by one, one way switch by using 1.5 Sq mm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including PVC concealed conduits and conduit accessories/fittings, pressed steel terminal switch boxes, 3 mm thick Bakelite sheet top cover (ISI Marked) fitted with Chromium plate brass screws washers and 1.5 Sq mm nominal cross sectional area multistranded copper conductor green PVC insulated unsheathed earth wire and connecting to earth dolly and make wall surface as existing same colour and making good disturbed surfaces of walls, floors, etc. to match with the existing good disturbed surfaces of walls, floors etc. match with the existing , complete all as specified and as directed by Engineer-in- Charge. Note : (a) wiring shall be done by using proper colour coding.
All as per Sl item no.63 above but for one socket outlet point 5 amps on independent board controlled by one, one way switch.
All as per Sl item no.63 but for one socket outlet point on same the baord with other switches.
Point wiring for 15 amps socket point controlled by one, one way switch using 2.5 Sq mm nominal cross sectional area multi stranded copper conductor, PVC insulated FRLS unsheathed cables in and including PVC concealed conduit and conduit fittings including pressed steel terminal switch boxes and 3 mm thick plate for fixing of switches/sockets and fitted with Chromium plated brass screws & washers and 2.5 Sq mm nominal cross sectional area multi stranded copper conductor, PVC insulated unsheathed earth wire and connected to earth dolly and making good disturbed surfaces of walls, floors, etc. to match with the existing good disturbed surfaces of walls, floors etc. match with the existing ,complete all as specified and as directed by Engineer-in- Charge. Note : (a) wiring shall be done by using proper colour coding.
Socket out let 2 in 1 socket 3 pin , 6 Amps flush type controlled by one switch ,complete all as specified and as directed by Engineer-in- Charge.
Switch piano flush type , SP,5/6 Amps, one way ,complete all as specified and as directed by Engineer-in- Charge.
Socket out let 2 in 1 socket 3 pin , 6 & 16 Amps flush type controlled by one switch ,complete all as specified and as directed by Engineer-in- Charge.
Switch piano flush type , SP,15 Amps, one way ,complete all as specified and as directed by Engineer-in- Charge.
Ceiling rose 3 terminal size 50x65mm surface type 230 volts ,complete all as specified and as directed by Engineer-in- Charge.
Lamp Holder insulated body with back plate for batten fitting suitable for LED lamp complete all as specified and directed by Engineer-in-Charge.
S&F Crystal glass LED tube light of 18W T8 , 4ft. (double side connection with LED driver) with very high efficacy suited for installation in existing tubelight G13 lamp holders to give glare free light complete all as specified and directed by Engineer-in-Charge.
S&F universal Regal batten for LED tube Double side connection Complete 1x22 Watt.
LED Adore Lamp 14/15W, B22 base 6500K CDL type ,complete all as specified and directed by Engineer-in-Charge.
Sub main wiring with two single core 4 Sqmm FRLS PVC insulated and unsheathed 1100 volts grade cables with stranded copper conductor cable drawn through in and including PVC casing caping and accessories including one single core 4 Sqmm FRLS PVC insulated unsheathed stranded copper earth cable connected to common earth dully complete, complete all as specified and directed by Engineer-in-Charge. Note : (i) 2 run of 4 Sqmm ,1 run of PVC casing caping & 1 run of 4 Sqmm earth cable will be measured as single run. (ii) Extra length of cables/wire required for connection to MCBs shall not be measured and paid separetly the rate quoted by contractor per unit shall be deemed to be included in the quoted rate of this item.
MCB SPN, 32 Amps, 240 Volts ,10 KA to be housed in DBs Proper and suitable size cable lugs to be fixed with MCBs as in replacment ,complete all as specified and directed by Engineer-in- Charge.
MCB SP, 6 to 32 Amps, ,240 Volts ,10 KA to be housed in DBs of Proper and suitable size cable lugs to be fixed with MCBs ,complete all as specified and directed by Engineer-in- Charge.
Supply only Sheet metal enclosure double door for DB's SPN 8 way 240 V having 200 A rated bus bar complete with all accessories as required on site ,complete all as specified and directed by Engineer-in-Charge.
Energy saving new generation Endura Rugby Neo - IP65, 10W LED IP65 bulkhead luminaire with opal diffuser, etc complete with all accessories rewired electrically connected in and including taking down of old unservicable fitting, complete all as specified and directed by Engineer-in-Charge.
Note : Schedule of credit to be deducted on acceptances of bid.Details of Schedule of credit is given in tender documents
M/S GLOBAL ENGINEERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .