RequiredExperience with Government
RequiredCertificate (Requested in ATC)
RequiredOEM Authorization Certificate
RequiredOEM Annual Turnover Bid to RA enabled Yes Water Tender Type B Or Fire Or Rescue Trucks ( 1 pieces ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) Generic Water Tender Type B for fire brigade use complete with Cabin and Chassis The appliance shall carry a water tank of 4500 to 7000 litre capacity depending upon the type of chassis used. It shall carry an extension ladder and shall be capable of towing a trailer pump * 1/15 Specification for water tender
Requiredtype B for fire brigade use In compliance to IS : 950 latest and with Builtup Cabin and Chassis * Water Tank capacity for upto 19000 Kg GVW 4500 L 4500 L Water Tank capacity for upto 31000 Kg GVW 5500 L 5500 L High and low pressure fire pump Capacity (Min) 2000 litre/min at 0.7 MPa and 300 litre/min 2000 litre/min at 0.7 MPa and 300 litre/min Cabin and Chassis Make of Chassis - * Chassis Model No - * Type of Fuel Diesel * Vehicle Emission Compliance BS-IV * Engine Power BHP@rpm 136 * Engine Torque Max
Required@ rpm 490 * Fuel Tank Capacity 250 * Length of Chassis 10000 * Width of Chassis 6500 * Height of Chassis 5400 * Gradeability of Chassis( %) 45 * Ground Clearance 230 * Wheel Base 3.5 * Gross vehicle mass including crew
Requiredwater and equipment 8 8000.0 Chassis Transmission System Automatic * No of Speed/Forward Gears 6 * Type of Steering Power * Turning Circle Diameter 15 * ABS Fitted No * Front Vehicle Brake - * Rear Vehicle Brake - * Type of Clutch - * 2/15 Body Work and Stowage Overall width 1.9 * Seating Capacity in the driver's cabin cum crew compartment 6 * Doors provided on each side of driver's cabin with hinged opening outward
Requiredhung forward with catch locks and flush type handles 2 * Construction of Cab and Lockers All metal construction with sufficient rigidity and reinforcement and shall be kept as light as possible in mass. Pressed sections of sufficient strength shall be used for the superstructure * Lockers to secure stowage of all equipments Yes
RequiredThe height of the lockers from the bottom to the top of the opening shall be not less than 600 mm. * Internal automatic lighting arrangement with the meter switch in the cab for lockers Yes * Locker Doors The doors of the. Lockers shall have sufficient means for holding them closed by efficient flush fitting spring loaded lockers. The doors of the side lockers shall not be hinged at the bottom. * Length of aluminium extension ladder 10.5 * Tool-Kit Container Yes
RequiredA specially fitted recessed tray for the normal * Water Tank Material Mild Steel * Thickness of Side Sheet 4 * Thickness of bottom Sheet 5 * Thickness of Baffel Plates 5 * Relavent surface treatment/paint details Yes * 3/15 for inner surface ensuring the potability of water as per IS Size of square Channel for body of main structure 32 mm X 1.6 mm * Base Frame Structure Mild Steel * Exterior and Interior Panel thickness of aluminium sheet for side body and roof 1.6 * Thickness of Flooring Made from Aluminium Chequered sheet 2 * Glasses:- Front wind screen
Requiredrear glass in two pieces (toughened type glass as per CMVR) Window with lock cum handle Yes * Top portion of fixed glass window & bottom portion in two halves in sliding pattern Yes * Standard automobile paint to the exterior body as per CMVR for Fire Tender Yes * Front Bumper Hook Yes * Rear Hook Yes * Rear Bumper Yes
Requiredrigidly fixed to the super structural members by means of nuts and bolts
Requiredfabricated from 100 mm × 50 mm× 5 mm mild steel channel * Cat Ladder Yes
RequiredTwo cat ladders made out of stainless steel round or square pipe of 25 mm diameter * Rear railing on body over the deck Yes
RequiredTwo numbers of 25 mm diameter aluminum pipe railing with sufficient number of aluminum double socket brackets * Safety guard to all the glasses of driver-cum- Quick removable type wire mesh guard made * 4/15 crew cabin from 25 mm × 25 mm size mild steel wire mesh of 1.6 mm covered in mild steel angle frame shall be provided Cable winch yes
Requiredas per clause 5.14 of IS 950 * Telescopic Light Mast or Inflatable Emergency Lighting System yes
Requiredas per clause 5.15 of IS:950 * Alternator Unit 6.5 KVA capacity portable diesel engine driven with all necessary connections and control panel * Hose Tunnels Hose tunnels shall be provided to carry four 2.5m lengths of suction hoses-in convenient location. The tunnels should be sloped in such a way that these allow the water/contents left in the hose after use to drain out. * Ladder Gallows Gallows shall be provided to carry a 10.5 m aluminium extrasion ladder. The design shall be such that the ladder can be released without difficulty from a reasonably accessible position and shall embody rollers to permit easy withdrawal by one man. Means shall also be provided for locking the ladder when stowed * Water Tank Febrication Water Tank construction A tank of required capacity suitably mounted on the chassis in a manner keeping in view the proper load distribution on the axles. * Runner A full length runner from behind the driver cabin till end of chassis * 5/15 frame shall be provided and made out of mild steel channel of 100 mm × 50 mm × 5 mm suitably fixed to the chassis frame with 6 mm thick mild steel plate and bolted to chassis frame wherever holes are available in the chassis frame and also with 16 mm ‘U’ bolts and nuts. Water Tank baffles 3.1 * Clamping Of Water Tank The water tank shall be fixed to the chassis frame and runner with ‘U’ clamps of 16 mm diameter with aluminum packing block and self-locking nuts * Water Tank Fitments The tank shall be fitted with a 50 mm bore overflow pipe . A 63 mm instantaneous hydrant connection
Requiredincorporating a strainer
Requiredshall be provided for filling the tank through 75 mm bore pipe work. An 100 mm bore pipeline shall be taken from/the tank for the suction inlet of the pump incorporating an 100 mm quick spherical type valve. * Anti Corrosive Treatment adequate anti-corrosive treatment from inside after fabrication . Inside surface shall be prepared by sand blasting before painting. Epoxy treatment should be given inside the water tank for corrosion resistance. Epoxy treatment shall consist of one coat of primer with 2 coats of finish. The tank with its fitments shall withstand hydrostatic * 6/15 pressure of 0.3 bar Water level indicator for the tank Dial gauge water level indicator for the tank in the driver cabin * Covered mainhole Diameter (minimum) 450mm with cover thickness of 5.0mm * Diameter of cleaning hole at bottom of Tank(minimum) 250 * Equipments and Accessories Fire fighting centrifugal pumps with priming devices shall confirm to the safety requirements and protection measures Yes * The pump shall be coupled to the prime mover of the chassis through a power take- off capable of transmitting full torque of the engine used for the appliance All propeller shafts and all fittings used for coupling the PTO
Requiredpump
Requiredetc
Requiredshall be of the same size and type as used by the chassis manufacturer for the drive line Yes * The PTO (Power Take - off Unit) Step up gear ratio of not less than 1:1.27. A cooling coil made of copper pipe shall be provided in the bottom of the PTO casing. * A control lever for engaging and disengaging the pump
Requiredwith suitable locking devices
Requiredshall be provided in the driver's cab Yes * Thermal Relief Valve A thermal relief valve (TRV) shall be fitted on the pump discharge side which will control the water temperature within the pump below 48°C (or 80°C – this version shall be used only when there is * 7/15 good operational reason) when the pump is operating in high rpm with closed discharge. The water discharged from the TRV with internal strainer(s) and blank cap(s). The strainer(s) shall be retained firmly when in use but shall be easily removable. The mesh size of the pump inlet screen shall be smaller than the outlet size of the impeller. High-Pressure Filter In case of regenerative impeller
Requiredthe water going to high-pressure impeller suction shall be filtered before entering in to the high pressure impeller. A filter capable of filtering particle size up to 0.75 mm or less shall be used. This filter shall be of stainless steel and shall be easily accessible for cleaning * Pump Primer The primer shall be capable of lifting water at least 7.0 m (measured from water level to the centre of pump) in not more than 24 s when connected with100 mm suction hose and 36 s when connected with 140 mm suction hose and shall preferably be fully automatic. The allowance shall be 300 mm for every 300 m elevation above mean sea level and 1 percent for 2.5°C rise in water temperature * Primer Type Water Ring Type * Delivery Valves for Pump two delivery valves for the 2000 litre/min pump * 8/15 Pipelines and Valves Yes
Requiredas per clause 5.8 of IS 950 * Control Panel Yes
Requiredas per clause 5.9.1 of IS:950 * Pump RPM Pressure Throttle Control Panel NA NA Water/Foam Monitor One water-cum-foam monitor shall be provided on the top at suitable location. The monitor shall confirm to IS 8442 * Pump casing and low pressure impeller material Lead tin bronze (Grade LTB 2 of IS 318) * High pressure impeller material Stainless steel * Impeller ring and impeller neck ring material Lead tin bronze (Grade LTB 2 of IS 318) * Pump shaft material Stainless steel (Grade 04Cr18 Ni10 of IS 6603) * Pump panel material chequered plates (IS 737) * Material for all parts which form water ways or come into contact with water stainless steel * All metal parts exposed to atmosphere shall either be of corrosion- resisting material or suitably treated to resist corrosion Yes * Workmanship or Finish All parts of the appliance shall be of good workmanship and shall have streamlined finish * Workmanship The appliance shall be painted fire red colour Conforming to Shade No. 536 of IS 5. The paint shall conform to IS 2932. * Instruction Books Instruction book( s) for the guidance of the user( s) including both * 9/15 operating and normal maintenance procedure shall be supplied. The book (s) shall include an itemized and illustrated spare-parts list giving reference numbers of all the wearing parts. Hand operated Fire Bell- 250 mm diameter mounted externally and capable of being operated from within the driver compartment Yes * Head Lamps 2 * Fog Lamps 2 * Reversing Lights a lamp suitably situated to assist reversing. * Multicolour Red- White-Blue LED light Bar situated on the head of the driving compartment as per CMVR Yes Yes Warning Lights Yes
RequiredMulticoloured Warning Lights Yes
RequiredMulticoloured Warning Lights Trafficators - Illuminated with indicating light on instrument panel or in any other prominent position in driving compartment Yes * Willd Screen Wippers Yes * All tools required for normal routine maintenance of the appliance which are not included in the kit for the chassis Yes * Siren Battery operated Yes * Search Light Adjustable to given flood or beam light
Requiredmounted in a convenient position but capable of being readily disconnect dand mounted on a tripod away from the * 10/15 appliance
Requiredcomplete with tripod and with not less than 30 m of TRS cable on a reel mounted on the appliance Spot Light - adjustable
Requiredmounted in a convenient position on the rear side of the driving compartment Yes * Inspection Lamp - protected type on wander lead with plug A socket shall be provided in the control panel in the driver's cab for plugging in the lamp Yes * Tail Lamps - two of combined stop and tail Yes * Rear Reflectors Yes * Side View Mirror Yes * Low Fuel Warning Light Yes * Standard Spare wheel and Tool Kit Yes * Public Address System - battery operated system with mike in the driver's cab and speaker on the top bf the vehicle Yes * Performance Capability of fire tender of being started from rest and move upon a gradient of 1 to 4 Yes * Performance of Brakes as per CMVR Yes * Stability of complete Fire tender The stability of the appliance shall be such that when under fully equipped and loaded condition ( but excluding crew)
Requiredif the surface on whicel the appliance stand is tilted to either side
Requiredthe point at which over-turning occurs is not passed at an angle of 27 degrees from the horizontal. * 11/15 Certification Manufacturer's name or trade-mark on Fire Tender Yes * Marking for Capacity of the water tank in Litres on fire Tender Yes * Marking for Year of Manufacture on Water Tender Yes * Warranty Time 6 6.0 Warranty Distance 500 Any applicable numeric value Battery Warranty 12 12.0 Numbers of Free Service 1 Any applicable numeric value Transportation Charge in Rupees Per Km 100 * Complete Fire Tender including Chassis
RequiredPTO and Body approval from ARAI/VRDE ICAT Yes * Chassis Certification including form 22 A from ARAI/VRDE ICAT Yes * * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer.