Loading…
Loading…
Tender Value
₹3.3 Cr
EMD Value
₹6.6 L
Closing Date
10 Jun 2026, 3:00 pm4d left
Electrical Work in c/w Upgradation of electric wiring in staff quarter over Jammu Division.
251-J-Elect-T-06-2026-27
251-J-Elect-T-06-2026-27
Open
6 Months
Jammu, Jammu And Kashmir
₹0
₹6.6 L
19 May 2026
19 May 2026
27 May 2026
Description:- Supply and Erection of modular metal boxes concealed boards with white finish
(Myrius), Schneider (Zencelo), Anchor (Ave) or similar. Metal boxes boards are to be concealed in the wall for 12 Module
Description:- Supply and Erection of modular metal boxes concealed boards with white finish
(Myrius), Schneider (Zencelo), Anchor (Ave) or similar Metal boxes boards are to be concealed in the wall for 8 Module
Description:- Supply and Erection of modular metal boxes concealed boards with white finish
(Myrius), Schneider (Zencelo), Anchor (Ave) or similar Metal boxes boards are to be concealed in the wall for 6 Module
Description:- Supply and Erection of modular metal boxes concealed boards with white finish
(Myrius), Schneider (Zencelo), Anchor (Ave) or similar Metal boxes boards are to be concealed in the wall for 4 Module
Description:- Supply and Erection of modular metal boxes concealed boards with white finish
(Myrius), Schneider (Zencelo), Anchor (Ave) or similar Metal boxes boards are to be concealed in the wall for 2 Module
tech. specification IS/IE rules and site requirment. JAMMU DIVISION-ELECTRICAL/NORTHERN RLY
tech. specification IS/IE rules and site requirment.
per tech. specification IS/IE rules and site requirment.
as per tech. specification IS/IE rules and site requirment.
Description:- Supplying, laying, testing and commissioning of FRLS 1.0 sq mm PVC insulated
Finolex, Havells, Polycab, KEI or similar in the recessed PVC conduit pipe 25 mm dia as required at site.
copper conductor cable 1100 Volt 1.5 Sq.mm multi stranded confirming to IS-694 latest in the existing PVC pipe.
Description:- Supply, laying, fixing, testing and commissioning of 2.5sq mm FRLS, PVC insulated
version),make Finolex, Havells, Polycab, KEI or equivalent in the existing PVC conduit for wiring of point wiring/circuit wiring/sub main/main as perTech Spec-I attached, IS & IE rules.
Description:- Supply, laying, fixing, testing and commissioning of 4 sq mm FRLS, PVC insulated
version),make Finolex, Havells, Polycab, KEI or equivalent in the existing PVC conduit for wiring of point wiring/circuit wiring/sub main/main as per Tech Spec-I attached, IS & IE rules.
9537/Pt.III/1983 or Latest Version with accessories, junction box, etc including making chase, plastering/clamping etc as per technical specifications.
Description:- Supply, fixing, testing and commissioning of LED tube light system wattage 18 Watt
connection from ceiling rose as per ISS/IR rules & site requirement as per CEE/N.Rly. Specification No.CEE/NR/121-Elect/PS/2018 (Rev '3') Dated 28.06.2018. & CEE/NR/121-Elect/PS/2019(Rev-04) dt 04.11.2019 with correction dt.10.02.2020 or latest.
Description:- Supply, fixing, installation, testing and commissioning of energy efficient 230V,50 Hz
speed-120 to 260 V AC with 5 step speed control electronic regulator, copper winding complete as per IS : 374-1979 or latest IE rule & site requirement. Make Bajaj, Usha, Havells, Crompton,Orient or equivalent.
single phase 230V.
core PVC insulated copper conductor flexible cable of size14/0.0076" and as per explanatory note.
mounted Pre-fabricated L.T. Distribution Boards of approved make, as per explanatory note & comprising; (i) Incoming MCB 40 A DP 10 KA B/C - 1 No. (ii) Outgoing MCB 16 A. SP 10 KA B/C - 6 Nos.
volts, 40 Amp RCCB having a sensitivity 30ma in the existing MCB DB complete with connections, testing and commissioning etc. as required., 40 amps.
propeller type exhaust fan complete as per IS, IE rule & site requirement. Make Usha, Orient, Bajaj or equivalent
JAMMU DIVISION-ELECTRICAL/NORTHERN RLY
power unit complete with modular plate, MCB, starter, plug &socket for AC of make Wipro North West (Model -ACPU6MBT/ ACPU6M-FT) or equivalent as per IS & IE rules.
Tank Capacity - 25 Litres"
Description:- "Design, manufacturing, supply, erection, testing & commissioning of wall mounted
MCCB 4 Pole250 A 35 KA B/C - 01Nos. (ii) Outgoing MCCB 4Pole 125 A 35 KA B/C - 05Nos. The Panel shall becomplete with 250 Amps.Copper bus bars for Phases and 125 Amp. For Neutral and as perexplanatory note. "
Description:- Transportation, Laying, underground/road/Railway track, recessing in platform /wall along with Rly. Track/in laid RCC/GI pipe as required 1.1 KV grade LT XLPE insulated armoured,
cable trench, sand cushioning, protective covering with second class bricks, provision of cable route marker as per Tech. Specification including end terminations with Aluminium Clamping socket/lugs, testing and commissioning of Upto 25 sq.mm
Description:- Transportation, Laying, underground/road/Railway track, recessing in platform /wall along with Rly. Track/in laid RCC/GI pipe as required 1.1 KV grade LT XLPE insulated armoured,
cable trench, sand cushioning, protective covering with second class bricks, provision of cable route marker as per Tech. Specification including end terminations with Aluminium Clamping socket/lugs, testing and commissioning of Above 25 sq.mm
Description:- Design, manufacturing of floor mounted MS feeder post made of MS sheet 16 SWG
having cable glands 2 Nos. duly grouted with cement concrete ratio 1:2:4 duly earthed with earthing terminals.
less than or equal to 10W (approx.) complete with driver as per IS, IE rules, site requirement and prior approval of sample
Description:- Earthing arrangement by providing earth electrode of GI pipe 50 mm dia (B class) 4.5 meter long with flange including 6 SWG GI earth wire from earth pipe to connecting point on switch
Tech specification at annexure 'A' relevant ISS & IE rules and site requirements. A suitable CI/MS/RCC cover as approved by Rly . Representative, cover with locking arrangement shall be provided.
mentioned in explanatory note.
existing MS/PVC conduit junction boxes/casing caping Anchor, Cona, Kinjal, SSK or equivalent as per IS, IE rules and site requirement.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
CEESpecLED.pdf
ATTACHMENT
RewirngSpec-I.pdf
ATTACHMENT
GCC2022.pdf
ATTACHMENT
ACS1.pdf
ATTACHMENT
ACS2.pdf
ATTACHMENT
ACS3.pdf
ATTACHMENT
ACS4.pdf
ATTACHMENT
ACS5.pdf
ATTACHMENT
ACS6.pdf
ATTACHMENT
2024_05_14ClarificationregardingsubmissionofAnnexure-VofGCC.pdf
ATTACHMENT
GCCACS9.pdf
ATTACHMENT
CorrectionSlipNo7GCCofApr-2022.pdf
ATTACHMENT
CorrectionSlipNo8GCCofApr-2022.pdf
ATTACHMENT
CorrectionSlipNo10GCCofApr-2022.pdf
ATTACHMENT
TechSpecforFeederPIllar.pdf
ATTACHMENT
251-J-Elect-T-06-2026-27.pdf
ATTACHMENT
Download all tender documents and submit your bid