Loading…
Loading…
Tender Value
₹8.9 Cr
EMD Value
₹17.9 L
Closing Date
3 Aug 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TRD
15 conditions · 4 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments'' in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. Note: - As per JPO Note No. JBP/W/R/T-14 dated 16.09.2022 for tenders, a condition stating that "Non submission of Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet by the tenderer shall result in summarily rejection of his / their bid" shall be introduced and tender cases shall be dealt accordingly. However, cases may arrive such as the tenderer may have submitted Annexure VI B or Information in Similar format, but not audited balance sheets, or otherwise, or have submitted audited balance sheets for incomplete years, but not submitted information in Annexure VIB etc. in such cases, Tender committee may decide to ask for audited balance sheet or Information as per annexure VIB (as the case may be) from chartered accountant. If the information is not received timely, tender committee may deal the case accordingly.
The tenderer must have successfully completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (a) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (b) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (c) One similar work each costing not less than the amount equal to 60% of advertised value of the tender.
Note: - Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organization, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of opening of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Similar nature of work as defined as: Provision/Modification to Traction Substation/Switching station involving 25/33/66/132/220 KV or above switchgear equipment, control and protection equipment or power factor correction equipment or erection and commissioning of transformer upto 30 MVA capacity or higher capacity (Authority: CEE/WCR/JBP's letter No. WCR/L/10/Tender Policy/3689 dtd.11.04.2012).
5 conditions · 3 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tenderers are instructed to kindly peruse the contents of attached document "Special Conditions of Letter of Credit as Mode of Payment" before exercising the option of payment through letter of credit as mode of payment.
(i)For participating in tender for an electrical nature of work, the contractor shall have to possess valid Electrical License of appropriate voltage issued by any State Government under clause 45 of compliance of rule of Indian Electricity rules 1956 or as amended from time to time. Electrifications of 11 KV and above including OHE, "A" class electrical contractor license is essential. (ii) The license can be possessed with one of the partners or in his own name if sole proprietor. Firm should submit a self-attested copy of the electrical contractor license along with the offer, otherwise, the offer will be summarily rejected.
Provision for segregation of Auto transformer between Bina -Katni section of Jabalpur Division(phase-2).
JBP-TRD-Tender-2026-08
JBP-TRD-Tender-2026-08
Open
Works - General
12 Months
Jabalpur, Madhya Pradesh
₹0
₹17.9 L
3 Aug 2026
10 Jul 2026
20 Jul 2026
80 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 8,93,32,220.3 | ||
| — | 10.00 | — | — | ||
| Preparation of design and drawing for modification in existing Sub-station/switching post. | — | — | — | 2,50,102 | |
| — | 10.00 | — | — | ||
| Supply of different terminal distribution board similar to as available at existing switching station and other similar places and its all connection as approved. | — | — | — | 2,82,800.9 | |
| — | 10.00 | — | — | ||
| Erection of different terminal distribution board similar to as available at existing switching station and other similar places and its all connection as approved. | — | — | — | 29,270.6 | |
| — | 78.00 | — | — | ||
| Cement concrete foundation in hard soil & rock soil. | — | — | — | 7,54,564.2 | |
| — | 273.00 | — | — | ||
| Cement concrete foundation in other than hard soil & rock soil. | — | — | — | 24,96,238.29 | |
| — | 89.70 | — | — | ||
| Supply of galvanized steel structure (traction mast/bridge mast etc.). | — | — | — | 1,30,00,766.38 | |
| — | 19.50 | — | — | ||
| Erection of galvanized steel structure (traction mast/bridge mast etc.) under power block. | — | — | — | 2,33,917.71 | |
| — | 15.60 | — | — | ||
| Supply of fabricated steel works/SPS for feeder. | — | — | — | 22,77,823.55 | |
| — | 3.90 | — | — | ||
| Erection of fabricated steel works/SPS for feeder under power block. | — | — | — | 54,839.46 | |
| — | 39.00 | — | — | ||
| Supply of 25kV double pole vacuum interrupter for 2x25kV AC along with structure and connectors with all accessories as per RDSO Specification No.TI/SPC/PSI/LVCBIN/0120 (Dec 2013), version-O with A&C slip No.1 (Oct-2016) or latest. | — | — | — | 4,34,31,404.64 | |
| — | 39.00 | — | — | ||
| Erection, commissioning and testing of 25kV double pole vacuum interrupter for 2x25kV AC along with structure and connectors with all accessories as per RDSO Specification No.TI/SPC/PSI/LVCBIN/0120 (Dec 2013), version-O with A&C slip No.1 (Oct-2016) or latest under power block. | — | — | — | 20,03,373.06 | |
| — | 39.00 | — | — | ||
| Supply of 25 kV double pole isolator. | — | — | — | 46,77,628.41 | |
| — | 39.00 | — | — | ||
| Erection, testing and commissioning of 25 kV double pole isolator under power block. | — | — | — | 3,67,488.42 | |
| — | 2730.00 | — | — | ||
| Supply of AAC wire 300 sq.mm. | — | — | — | 15,96,640.5 | |
| — | 2730.00 | — | — | ||
| Erection of AAC wire 300 sq.mm. under power block. | — | — | — | 1,53,316.8 | |
| — | 1170.00 | — | — | ||
| — | — | — | 4,81,080.6 | ||
| — | : - Supply | of parallel clamp with A&C Slip No-1, Drawing: | Specification STR: | ||
| — | 5460.00 | — | — | ||
| Supply of GI 16 x 50 x 38 nut, bolt and washer. | — | — | — | 2,54,545.2 | |
| — | 6240.00 | — | — | ||
| Supply of 10 core 2.5 sq.mm. copper cable. | — | — | — | 23,32,574.4 | |
| — | 6240.00 | — | — | ||
| Erection of 10 core 2.5 sq.mm. copper cable. | — | — | — | 1,86,576 | |
| — | 6240.00 | — | — | ||
| Supply of 2 core 4 sq.mm. copper cable. | — | — | — | 11,15,400 | |
| — | 6240.00 | — | — | ||
| Erection of 2 core 4 sq.mm. copper cable. | — | — | — | 89,232 | |
| — | 6240.00 | — | — | ||
| Supply of 2 core 2 sq.mm. copper cable. | — | — | — | 5,39,884.8 | |
| — | 6240.00 | — | — | ||
| Erection of 2 core 2 sq.mm. copper cable. | — | — | — | 1,78,464 | |
| — | 234.00 | — | — | ||
| Reinforced concrete for foundation, trench & baffle wall with 200 mm aggregates(M- 20 type). | — | — | — | 30,74,434.74 | |
| — | 780.00 | — | — | ||
| Supply of cable trench covers. | — | — | — | 29,96,362.2 | |
| — | 312.00 | — | — | ||
| Supply of solid core/post/cut in/suspension-9T feeder insulator. | — | — | — | 39,57,145.92 | |
| — | 312.00 | — | — | ||
| Erection of solid core/post/cut in/suspension-9T feeder insulator under power block. | — | — | — | 4,37,349.12 | |
| — | 78.00 | — | — | ||
| Supply of earth electrode. | — | — | — | 2,59,367.16 | |
| — | 78.00 | — | — | ||
| Erection of earth electrode. | — | — | — | 1,20,078.66 | |
| — | 780.00 | — | — | ||
| Supply of MS flat 75x8 sq.mm. | — | — | — | 2,05,631.4 | |
| — | 780.00 | — | — | ||
| Erection of MS flat 75x8 sq.mm. | — | — | — | 69,388.8 | |
| — | 195.00 | — | — | ||
| Supply of 8 SWG wire. | — | — | — | 4,231.5 | |
| — | 195.00 | — | — | ||
| Erection of 8 SWG wire. | — | — | — | 1,692.6 | |
| — | 78.00 | — | — | ||
| Supply of retro-reflective number plate. | — | — | — | 1,08,654.78 | |
| — | 78.00 | — | — | ||
| Erection of retro-reflective number plate. | — | — | — | 5,754.06 | |
| — | 390.00 | — | — | ||
| Supply of ballast in switching yard. | — | — | — | 4,38,344.4 | |
| — | 390.00 | — | — | ||
| Spreading of ballast in switching yard. | — | — | — | 3,385.2 | |
| — | 312.00 | — | — | ||
| Supply of various type of connectors, splices, tee connectors etc. of all required sizes. | — | — | — | 8,56,037.52 | |
| — | 312.00 | — | — | ||
| Erection of various type of connectors, splices, tee connectors etc. of all required sizes. | — | — | — | 6,430.32 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderDocument2026-08AutoTransformersegregation.pdf Tender Document
ATTACHMENT
GCC-April-2022.pdf
ATTACHMENT
AdvancecorrectionslipNo1to10ofGCC2022_compressed.pdf Advance Correction Slip No 1 to 10
ATTACHMENT
AdvanceCorrectionSlipNo11toIRGCC2022_compressed1.pdf Advance Correction Slip No 11
ATTACHMENT
RBContractore-MBLetter.pdf
ATTACHMENT
AdvancecorrectionslipNo1to10ofGCC2022_compressed.pdf
ATTACHMENT
AdvanceCorrectionSlipNo11toIRGCC2022_compressed1.pdf
ATTACHMENT
TenderDocument2026-08AutoTransformersegregation.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .