Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.1 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹29.6 L+₹13,805 (0.47%)Rejected-Finance 5 6 MINTO ROAD ALLAHABAD 211001 | PRAYAGRAJ | UTTAR PRADESH | 211001 | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹34.0 L+₹4.6 L (15.5%)Rejected-Finance | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹37.0 L+₹7.6 L (25.7%)Rejected-Finance ROOM NO 680 GANESH MURTY NAGAR PART NO 03 CAPT PRAKASH PETHE MARG COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L4 | Rejected-Finance Being not lowest | |
| 5 | L5₹39.8 L+₹10.4 L (35.2%)Rejected-Finance | L5 | Rejected-Finance Being not lowest |
| Sl No | Description | Qty | Unit | NOEL ENGINEERS L5 | Rama Construction Co L6 | SHREE SHIV SHANKER ENTERPRISE L1 | Frends Enterprises L2 | Accura Associates L3 | B P ENTERPRISES L4 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L Point wiring (concealed type) with 1.5 sqmm, PVC insulated unsheathed (FRLSH), 1100 volts grade, multi-stranded copper conductor, in and including rigid non-metallic PVC heavy duty conduit (ISI mark), 19/ 20 mm dia suitable size including cutting chases for conduits, sinking for boxes for concealed conduit wiring with all fittings and accessories including with and fix concealed 1.2 mm thick pressed steel sunken box along with cover plate and frame, suitable for fixing modular switch/ socket and unsheathed (FRLSH) single core multi-stranded copper conductor cable of size 1.5 sqmm green in colour as earth continuity conductor connected to common earth dolly and making good to the disturbed surfaces to match the existing surfaces complete (fill up cement in gaps, finishing with putti and apply two coats of paint as per existing type paint, match with existing colour in disturbed surface area), as per IS specification and as specified in SSR Part-I complete for one light point / bell point/ Exhaust Fan point / wall fan point controlled by one modular switch, 1 way 6/10 amps, 1 module. | 120 | Per Point | 490 ₹58,800 | 400 ₹48,000 | 550 ₹66,000 | 420 ₹50,400 | 250 ₹30,000 Lowest | 500 ₹60,000 |
| 2.00 | All as per serial No.1 here-in before but for one bell point controlled by one switch. | 20 | Per point | 490 ₹9,800 | 400 ₹8,000 | 550 ₹11,000 | 420 ₹8,400 | 290 ₹5,800 Lowest | 500 ₹10,000 |
| 3.00 | All as per serial No.1 here-in before but for One ceiling fan point controlled by one switch & regulator | 50 | Per point | 490 ₹24,500 | 400 ₹20,000 | 550 ₹27,500 | 420 ₹21,000 | 350 ₹17,500 Lowest | 500 ₹25,000 |
| 4.00 | All as per serial No.1 here-in before but for One 3 pin socket point 5 Amps on independent board | 60 | Per point | 490 ₹29,400 | 400 ₹24,000 | 550 ₹33,000 | 420 ₹25,200 | 360 ₹21,600 Lowest | 500 ₹30,000 |
| 5.00 | All as per serial No.1 here-in before but for One 3 pin socket point 5 Amps on the same board | 60 | Per point | 70 ₹4,200 Lowest | 250 ₹15,000 | 150 ₹9,000 | 200 ₹12,000 | 370 ₹22,200 | 200 ₹12,000 |
| 6.00 | All as per srl item No. 1 here-in-before but for one socket point 15 Amp with 2.5 sq mm PVC unsheathed FRLS wire along with 2.5 sq mm green colour wire as earth contuinity conductor connected to common earth dolly all as specified & as directed by Engr-in-Charge. | 30 | Per Point | 540 ₹16,200 | 500 ₹15,000 | 600 ₹18,000 | 525 ₹15,750 | 380 ₹11,400 Lowest | 600 ₹18,000 |
| 7.00 | All as per srl item No. 1 here-in-before but for one socket point 15 Amp with 4 sq mm PVC unsheathed FRLS wire along with 4 sq mm green colour wire as earth contuinity conductor connected to common earth dolly all as specified & as directed by Engr-in-Charge. | 10 | Per Point | 1,050 ₹10,500 | 500 ₹5,000 | 675 ₹6,750 | 550 ₹5,500 | 380 ₹3,800 Lowest | 780 ₹7,800 |
| 8.00 | M&L in Point wiring with PVC insulated unsheathed single core multi stranded copper conductor 1.5 sqmm, 1100 volts grade cable, FRLSH, passing through PVC casing caping including modular PVC Gang box of suitable module for mounting of modular Switches & Sockets as required at site along with one run of PVC insulated unsheathed multistranded copper conductor cable 1.5 sqmm (green colour) FRLSH as earth wire connected to earth dolly all as specified & as directed by Engr-in-Charge for one light/ Exhaust fan/ Wall Fan point controlled by one switch. | 500 | Per Point | 440 ₹2,20,000 | 400 ₹2,00,000 | 450 ₹2,25,000 | 306 ₹1,53,000 Lowest | 350 ₹1,75,000 | 400 ₹2,00,000 |
| 9.00 | All as per item No. 8 above but One bell point controlled by one bell push. | 80 | Per Point | 440 ₹35,200 | 400 ₹32,000 | 450 ₹36,000 | 310 ₹24,800 Lowest | 380 ₹30,400 | 400 ₹32,000 |
| 10.00 | All as per item No. 8 above but One ceiling fan point controlled by one switch & regulator. | 130 | Per Point | 440 ₹57,200 | 400 ₹52,000 | 450 ₹58,500 | 310 ₹40,300 | 360 ₹46,800 | 40 ₹5,200 Lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
12 Aug 2025, 6:00 pmClosed
Kameshwar Prasad, IDSE, EE
GE(West), Colaba, Mumbai - 400 005
REPAIR/REPLACEMENT OF OLD UNSV ELECTRIC FITTING AND FIXTURES ALONGWITH DBS, SUBMAIN WIRING AND CONNECTED ITEMS OF MD ACCN UNDER GE (W) COLABA, MUMBA
2025_MES_720398_1
8100/E8
Open Tender
Civil Works
Item Rate
270 days
GE(West), Colaba
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (W) Colaba, Mumbai
₹80,000
Yes
5 Sept 2025
14 Jul 2025
14 Aug 2025
14 Jul 2025
12 Aug 2025
29 Jul 2025
Amount
M&L Point wiring (concealed type) with 1.5 sqmm, PVC insulated unsheathed (FRLSH), 1100 volts grade, multi-stranded copper conductor, in and including rigid non-metallic PVC heavy duty conduit (ISI mark), 19/ 20 mm dia suitable size including cutting chases for conduits, sinking for boxes for concealed conduit wiring with all fittings and accessories including with and fix concealed 1.2 mm thick pressed steel sunken box along with cover plate and frame, suitable for fixing modular switch/ socket and unsheathed (FRLSH) single core multi-stranded copper conductor cable of size 1.5 sqmm green in colour as earth continuity conductor connected to common earth dolly and making good to the disturbed surfaces to match the existing surfaces complete (fill up cement in gaps, finishing with putti and apply two coats of paint as per existing type paint, match with existing colour in disturbed surface area), as per IS specification and as specified in SSR Part-I complete for one light point / bell point/ Exhaust Fan point / wall fan point controlled by one modular switch, 1 way 6/10 amps, 1 module.
All as per serial No.1 here-in before but for one bell point controlled by one switch.
All as per serial No.1 here-in before but for One ceiling fan point controlled by one switch & regulator
All as per serial No.1 here-in before but for One 3 pin socket point 5 Amps on independent board
All as per serial No.1 here-in before but for One 3 pin socket point 5 Amps on the same board
All as per srl item No. 1 here-in-before but for one socket point 15 Amp with 2.5 sq mm PVC unsheathed FRLS wire along with 2.5 sq mm green colour wire as earth contuinity conductor connected to common earth dolly all as specified & as directed by Engr-in-Charge.
All as per srl item No. 1 here-in-before but for one socket point 15 Amp with 4 sq mm PVC unsheathed FRLS wire along with 4 sq mm green colour wire as earth contuinity conductor connected to common earth dolly all as specified & as directed by Engr-in-Charge.
M&L in Point wiring with PVC insulated unsheathed single core multi stranded copper conductor 1.5 sqmm, 1100 volts grade cable, FRLSH, passing through PVC casing caping including modular PVC Gang box of suitable module for mounting of modular Switches & Sockets as required at site along with one run of PVC insulated unsheathed multistranded copper conductor cable 1.5 sqmm (green colour) FRLSH as earth wire connected to earth dolly all as specified & as directed by Engr-in-Charge for one light/ Exhaust fan/ Wall Fan point controlled by one switch.
All as per item No. 8 above but One bell point controlled by one bell push.
All as per item No. 8 above but One ceiling fan point controlled by one switch & regulator.
All as per item No. 8 above but for one light point controlled by two way switches (two way switch point wiring).
All as per item No. 8 above but One 3 pin socket point 5 Amps on independent board.
All as per item No. 8 above but One 3 pin socket point 5 Amps on the same board.
All as per item No. 8 above but for one socket point 15 Amp with 2.5 sqmm PVC unseathed FRLSH wire along with 2.5 sqmm green colour wire as earth contuinity conductor connected to common earth dolly, complete all as specified and as directed.
All as per item No. 8 above but for one socket point 15 Amp with 4 sqmm PVC unseathed FRLSH wire along with 4 sqmm green colour wire as earth contuinity conductor connected to common earth dolly, complete all as specified and as directed.
S&F in repairs Moduler Switch single pole, one way 6/10 Amp with all fittings and accessories including with and fix concealed 1.2 mm thick pressed steel sunken box along with cover plate and frame, complete all as specified and as directed.
S&F in repairs Moduler Switch single pole, one way 16 Amp with all fittings and accessories including with and fix concealed 1.2 mm thick pressed steel sunken box along with cover plate and frame, complete all as specified and as directed.
S&F in repairs Moduler socket 2/3 pin 6 Amp with all fittings and accessories including with and fix concealed 1.2 mm thick pressed steel sunken box along with cover plate and frame, complete all as specified and as directed.
S&F in repairs Moduler socket 6/16 A 2/3 pin with all fittings and accessories including with and fix concealed 1.2 mm thick pressed steel sunken box along with cover plate and frame, complete all as specified and as directed.
S&F in repairs Moduler stepped type electronic fan regulator 450 watt flush type, two module with all fittings and accessories including with and fix concealed 1.2 mm thick pressed steel sunken box along with cover plate and frame, complete all as specified and as directed.
S&F Moduler bell push, 2 modue, 10 Amp with all fittings and accessories including with and fix concealed 1.2 mm thick pressed steel sunken box along with cover plate and frame, complete all as specified and as directed.
S&F in repairs Switch flush type single pole, two way 6/10 Amp including PVC Box and Hylem sheet of required size, complete all as specified and as directed.
S&F in repairs Switch flush type single pole, one way 6/10 Amp including PVC Box and Hylem sheet of required size, complete all as specified and as directed.
S&F in repairs socket 2/3 pin 6 Amp including PVC Box and Hylem sheet of required size, complete all as specified and as directed.
S&F in repairs Switch flush type single pole, one way 16 Amp including PVC Box and Hylem sheet of required size, complete all as specified and as directed.
S&F in repairs switch socket 2/3 pin 5/6 Amp including PVC Box and Hylem sheet of required size, complete all as specified and as directed.
S&F in repairs switch socket 6/16 A 2/3 pin including PVC Box and Hylem sheet of required size, complete all as specified and as directed.
S&F in repairs stepped type electronic fan regulator 450 watt flush type, two module including PVC Box and Hylem sheet of required size, complete all as specified and as directed.
S&F in repairs bell push, 2 modue, 10 Amp two module including PVC Box and Hylem sheet of required size, complete all as specified and as directed.
S&F in repairs Modular type AC Box, 4 Module with Socket and 25 Amp SP mini MCB in plastic box enclosure along with cover plate and top, complete all as specified and as directed.
S&F in repairs Metal AC/ Geyser Box with Socket and 20 Amp SP mini MCB in plastic box enclosure along with cover plate and top, complete all as specified and as directed.
S&F in repair bell ding dong, AC, 230 volts, single pole, complete all as specified and as directed.
S&F in repairs Modular electronic chime Bell ding dong/ Buzzer wall mounted, AC, 230 volts, complete all as specified and as directed.
S&F in repairs non-metallic PVC flexible conduit dia 23mm white/ black, complete all as specified and as directed.
S&F in repairs non-metallic PVC casing capping of size 50X24mm (for fixing the telephone cable and lan cable), complete all as specified and as directed.
S&F in repairs ceiling rose surface bakelite 65x50mm, 3 terminal, complete all as specified and as directed.
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, regulators, switch socket outlet, bulk head fittings, tube light fittings, etc. and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc, complete all as specified and directed.
Taking down carefully copper/aluminum submain wiring complete including conduits and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc, complete all as specified and directed.
S&F in repairs non-metallic PVC casing capping of size 25X12mm, complete all as specified and directed.
M&L Sub main wiring with two runs of 16 sqmm stranded copper conductor PVC unsheathed FRLSH wire along with 16 sqmm green colour wire as earth contuinity conductor connected to common earth dolly including PVC FR heavy duty conduit of adequate size (not less than 60 mm dia) for housing the wires from panel / Main DB to house SPN DB, complete all as specified and directed by Engr-in-Charge. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Mode of measurement two runs of 16 sqmm cable and one run of 16 sqmm cable with PVC conduite shall be measured as one length.
M&L in Sub main wiring with two runs of 10 sqmm stranded copper conductor PVC unsheathed FRLSH wire along with 10 sqmm green colour wire as earth contuinity conductor connected to common earth dolly including PVC FR heavy duty conduit of adequate size (not less than 50 mm dia) for housing the wires from panel / Main DB to house SPN DB, complete all as specified and directed by Engr-in-Charge. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Mode of measurement two runs of 10 sqmm cable and one run of 10 sqmm cable with PVC conduite shall be measured as one length.
M&L in Sub main wiring with two runs of 6 sqmm stranded copper conductor PVC unsheathed FRLSH wire along with 6 sqmm green colour wire as earth contuinity conductor connected to common earth dolly including PVC FR heavy duty conduit of adequate size (not less than 35 mm dia) for housing the wires from pannel / Main DB to house SPN DB, complete all as specified and directed by Engr-in-Charge. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Mode of measurement two runs of 6 sqmm cable and one run of 6 sqmm cable with PVC conduite shall be measured as one length.
M&L in Sub main wiring with two run of 4 sqmm stranded copper conductor PVC unseathed FRLSH wire along with 4 sqmm green colour wire as earth contuinity conductor connected to common earth dolly including PVC FR heavy duty conduite of adequate size (not less than 32 mm dia) for housing the wires for from Internal DB to DB, complete all as specified and directed by Engr-in-Charge. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Mode of measurement two runs of 4 sqmm cable and one run of 4 sqmm cable with PVC conduite shall be measured as one length.
Supply and fix lay cable in repair insulated screened PVC bedded, unarmoured, sheathed, electric cables 1100 volts grade with stranded copper conductor of size 1.5 Sqmm 3 core (from ceiling rose to fan), complete all specified and directed.
S&F in repairs non-metallic flexible conduit of 25mm dia including all necessay accessories, complete all specified and directed.
S&F in repairs 20 watt LED 4 feet long fixed on PVC square for mounting the fittings and electrically conncected with suitable size of PVC insulated multistranded copper flexible white colour cable from ceiling rose to light fitting (connector block of lamp fitting), complete all specified and directed.
S&F in repairs surface mounted 9/10 watts LED tube light fitting and electrically conncected with suitable size of PVC insulated multistranded copper flexible white colour cable from ceiling rose to light fitting, complete all specified and directed.
S&F in repairs surface mounted 12 watts LED Wall bracket fancy type in golden colur conncected with suitable size of PVC insulated multistranded copper flexible white colour cable from ceiling rose to light fitting, complete all specified and directed.
S&F in repairs Smart Light strip light with suitable size LED driver Warm White with minimum 400 lumen/ meter light output and IP65 water resistant and fixed in ceiling / wall with 2 Nos PVC block and channel duly incarved into POP/ wooden sheet ceiling suitable size, complete all specified and directed.
S&F in repairss LED Mirror light fittngs 2 feet 10w extruded polycarbonate, golden type electrically conncected with suitable size of PVC insulated multistranded copper flexible white colour cable from ceiling rose to light fitting, complete all specified and directed.
S&F in repairs Recess Mounting LED panel, square/ Circular Type, 12/15/22 Watt capacity, warm white/ bright white, environmentlal friendly, new generation, ashthetically designed ultra modern, fully diffused, white powder coated, with polymer diffuser complete with acessories suitable for Armstrong/Grid ceiling, complete all specified and directed.
S&F in repairs Recess Mounting LED panel, square/ Circular Type, 18 Watt capacity, warm white/ Bright white, environmentlal friendly, new generation, ashthetically designed ultra modern, fully diffused, white powder coated, with polymer diffuser complete with acessories suitable for Armstrong/Grid ceiling, complete all specified and directed.
S&F in repairs LED 36 Watt 3000 K, Slim raccess mounted LED panel 2x2 with premium diffuser to ensure glare free & even light distribution, with integrated electronic driver of same make connecting with PVC insulated and PVC sheathed copper flexible cable and necessary fixing arrangement, complete all specified and directed.
S&F in repairs LED 7/8 Watt 3000 K/6000k, Slim raccess mounted spot light trio (three lights) LED panel with premium diffuser to ensure glare free & even light distribution in area, with integrated electronic driver of same make connecting with PVC insulated and PVC sheathed copper flexible cable and necessary fixing arrangement, complete all specified and directed.
S&F in repairs LED 3/4 Watt 3000 K/6000k, Slim raccess mounted spot light LED panel with premium diffuser to ensure glare free & even light distribution in area, with integrated electronic driver of same make connecting with PVC insulated and PVC sheathed copper flexible cable and necessary fixing arrangement all as specified and directed. Make - BAJAJ/Havells / Wipro/ Jaguar
S&F in repairs LED building security light fitting 45 watt, luminaire fixture in IP 66 protection level output of LED lamp efficiency minimum 100 luman per watt after all losses, pressure die-cast aluminium housing LED Street light with GI clamp including connected accessories and bracket made of GI Pipe 50mm dia light grade 1.25 m long, bend to shape with two sets of MS flat iron clamps, nuts, bolts, washers, etc. all as directed by Engineer-in-Charge. Note : The rate quoted must be inclusive of 3 core 1.5sqmm cable for connecting the light to supply.
S&F in repairs DB vertical type 8 way VTPN double door load line powder coated alongwith 200 Amp rated Bus bar fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, complete all as specified and directed. Note: Thimble/lugs of rating of MCCB should be used with wire for fixing in the MCB.
S&F in repairs DB vertical type 6 way VTPN double door load line powder coated alongwith 200 Amp rated bus bar fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, complete all as specified and directed. Note: Thimble/lugs of rating of MCCB should be used with wire for fixing in the MCB.
S&F in repairs DB vertical type 4 way VTPN doubble door load line powder coated alongwith 200 Amp rated Bus bar fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, complete all as specified and directed. Note: Thimble/lugs of rating of MCCB should be used with wire for fixing in the MCB.
S&F in repairs MCB TPN 4 pole 63 amps, 'C' series, breaking capacity 10 KA, 'C' curve 240 volts, 50Hz including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and directed.
S&F in repairs MCB TPN 4 pole 100 amps, 'C' series, breaking capacity 10 KA, 'C' curve 240 volts, 50Hz including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and directed.
S&F in repairs MCB TPN 4 pole 125 amps, 'C' series, breaking capacity 16 KA, 'C' curve 240 volts, 50Hz including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and directed.
S&F in repairs MCCB 4 pole 200 amps, 'C' series, breaking capacity 25 KA, 'C' curve 240 volts, 50Hz including necessary incoming and outgoing electric connection with suitable size of copper lugs, complete all as specified and directed.
S&F in repairs sheet metal enclosures double door, for DBs when MCBs to be used 240 volts 2 way without bus bar fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, complete all as specified and directed.
S&F in repairs sheet metal enclosures double door, for DBs when MCBs to be used 240 volts 4 way with 200 Amps rated bus bar single pole and neutral fixed on wall by cutting chasing and making good to the disturbed surface board in and including copper lugs/thimbles duly crimped for connection, complete all as specified and directed.
S&F in repairs sheet metal enclosures double door, for DBs when MCBs to be used 240 volts 6 way with 200 Amps rated bus bar for single pole and neutral fixed on wall by cutting chasing and making good to the disturbed surfaced board in and including copper lugs/thimbles duly crimped for connection, complete all as specified and directed.
S&F in repairs sheet metal enclosures double door, for DBs when MCBs to be used 240 volts 8 way with 200 Amps rated bus bar for single pole and neutral fixed on wall by cutting chasing and making good to the disturbed surfaced board in and including copper lugs/thimbles duly crimped for connection, complete all as specified and directed.
S&F in repairs sheet metal enclosures double door, for DBs when MCBs to be used 240 volts 12 way with 200 Amps rated bus bar single pole and neutral fixed on wall by cutting chasing and making good to the disturbed surfaced board in and including copper lugs/thimbles duly crimped for connection, complete all as specified and directed.
S&F in repairs MCB SP 240 volt, 16 to 63 Amps, C series all as specified and directed. Note: Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB, complete all as specified and directed.
S&F in repairs MCB SPN 240 volt, 20 to 63 Amps, C series, complete all as specified and directed. Note: Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB.
Supply & laying in repair, sub main wiring (concealed type) AC Point/ DB to DB with two run of 4 sqmm stranded copper conductor wire (FRLSH) with one run of 4 sqmm stranded copper conductor as earth continuty conductor connected to common earth dolly including adequate size and including rigid non-metallic PVC heavy duty conduit (ISI mark), 19/ 20 mm dia suitable size including cutting chases for conduits, complete all as specified and directed. Note: Mode of measurement two runs of 4 sqmm cable and one run of 4 sqmm cable shall be measured as one length.
S&F in repairs LED light driver suitable for recessed light rating from 5W upto 40W, complete all as specified and directed by Engr- In-Charge.
S&F in repairs LED based of rating 9 watts thread type/ Pin type bulb suitable for decorative lights as directed by Engr- In-Charge.
S&F in repairs LED based of rating 12 watts thread type/ Pin type bulb suitable for decorative lights as directed by Engr- In-Charge.
S&F in repairs LED based of rating 14 watts thread type/ Pin type bulb suitable for decorative lights as directed by Engr- In-Charge.
M & L for painting of asthetically looking decoratibe / ceiling lights with golden/silver paint and other painting accessories as required at site and as directed by Engr in Charge.
S&F in repairs for Exhaust fan metal body/Plstic having 70 watt power double ball bearing high speed of sweep size 300 mm, inbuilt bird guard and air delivery more than 450 CMM with nuts bolts, fastners including connecting with PVC insulated and PVC sheathed copper flexible cable and necessary fixing arrangement, complete all as directed and directed.
S&F in repairs moduler/plastic/steel type junction box with hylam sheet of size 4x4", 4x7" and 6x8", complete all as specified and directed.
S&F in repairs moduler/plastic/steel type junction box hylam sheet of size 10x12" and 8x10", complete all as specified and directed.
S&F in repairs moduler/plastic/steel type junction box hylam sheet of size 12x12", complete all as specified and directed.
S&F in repairs for Exhaust fan metal body/Plstic having 70 watt power double ball bearing high speed of sweep size 250 mm, inbuilt bird guard and air delivery more than 450 CMM with nuts bolts, fastners including connecting with PVC insulated and PVC sheathed copper flexible cable and necessary fixing arrangement, complete all as specified and directed.
S&F in repairs Wall fan, made of sturdy Engineering plastic, voltage 230V, 50 Hz, RPM 1350 Copper winding of sweep 400 mm including connection as required at site, complete all as specified and directed.
M & L for fabrication and fixing of fan hook made out of 12mm dia MS rod suitable for fan hook bend to shape 'S' including 12mm dia SS fastner as required at site and as directed by Engr in Charge.
Material and labour for filling wall cavity in cement mortar 1:3 not exceeding 10 centimetre in girth to ends or edges including taking out existing metal or wooden sinking box and making good to wall surface for recessed / concealed modular metal flush box or concealed conduit wiring, etc., complete all as specified and as directed.
S&F in repairs for Exhaust fan Plastic body having 45 watt power double ball bearing high speed of sweep size 250 mm, inbuilt bird guard and air delivery more than 450 CMM with nuts bolts, fastners including connecting with PVC insulated and PVC sheathed copper flexible cable and necessary fixing arrangement, complete all as specified and directed.
Transportation and fixing of Exhaust fan metal body/Plastic of any size with nuts bolts, fastners including connecting with PVC insulated and PVC sheathed copper flexible cable and necessary fixing arrangement complete all as directed including deposition old fan safely in MES store, complete all as specified and directed.
Transportation and fixing/ reconnecting Electric Energy Meter Single Phase & Three Phase with wooden ply to provide sturdy support base including necessary fixing arrangement of copper submain wires complete all as directed including deposition old meter safely in MES store, complete all as specified and directed.
S&F in repairs for Exhaust fan Plstic body having 45 watt power double ball bearing high speed of sweep size 150 mm, inbuilt bird guard and air delivery more than 450 CMM with nuts bolts, fastners including connecting with PVC insulated and PVC sheathed copper flexible cable and necessary fixing arrangement, complete all as specified and directed.
Transportation and fixing of Ceiling Fan of any size with hooks, nuts bolts, Down rod, fastners including connecting with PVC insulated and PVC sheathed copper flexible cable and necessary fixing arrangement complete all as directed including deposition old fan safely in MES store, complete all as specified and directed.
S&F in repairs Fan condenser 1.5 mfd at required location, complete all as specified and directed.
S&F in repairs Fan condenser 2.5 mfd at required location, complete all as specified and directed.
Labour only for servicing of ceiling fan at site any size and make including oiling, greasing, cleaning of blades, checking of working speed, quarter pin, rubber real and replacement of unserviceable parts and taking down, rehanging after cleaning, servicing the fan as and when required bases, complete all as specified and directed.
All as per srl item No 92 here-in-before but for Exhaust fans of any size and any make, complete all as specified and directed.
S&F in repairs / laying cable in repair PVC insulated screened PVC bedded, unarmoured, sheathed, electric power cables 1100 volts grade with stranded copper conductor of size 6 Sqmm 3 core with non metalic PVC FR, heavy duty conduit of suitable size (20mm dia or more), with shaddle, complete all as specified and directed. Note: Mode of measurement 6 Sqmm 3 core cable with PVC conduite shall be measured as one length.
Supplying, laying, commissioning & testing LT underground cables 10 Sqmm X 2 Core, 1100 Volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi-stranded aluminium conductor all as per IS 7098 (Part -1) laid in trenches, ducts, drawn through pipes or fixed on poles, as and when required on ground including taking down for old unserviceable cable. Note:- Al Lugs are all inclusive.
All as per item No. 95 above but 16 Sqmm X 2 Core.
S&F in steel perforated trunking system of size 100X30mm and providing sturdy nuts and bolts for connecting cable trunking steadily onto walls or lying in air steadily with help of metal frame, complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cmx6.3 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level, connected to 4 mm dia GI wire as earthling lead by means of blots and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber, MS funnel, wire gauge. CI cover with frame, 15mm dia GI pipe light grade for protection of wire etc including necessary excavation in any type of strata, returning, filling removal of soil outside MD land, filling of charcoal and salt complete all as shown in electrical plate No. 3 of MES Sch Part I, connected to earthing test point all as specified and directed on testing on completion.
M & L for sadling of cable of any size duly attached on wall with help of iron brackets of required size, complete all as directed by Engr- In Charge.
S&F in repairs clamps for fixing/ hanging Geyser appropriate shape suitable for storage type water heater (Geyser), complete all as specified and directed. Make:- As per sample.
S&F in repairs geyser stop valve appropriate shape suitable for storage type water heater (Geyser), complete all as specified and directed. Make:- As per sample.
S&F in repairs angle cock appropriate shape suitable for storage type water heater (Geyser), complete all as specified and directed. Make:- As per sample.
S&F in repairs GI fitting Barrel Pieace 1/2" pipe 15 mm size appropriate shape suitable for storage type water heater (Geyser), complete all as specified and directed.
S&F in repairs GI pipe 15 mm size suitable for storage type water heater (Geyser), complete all as specified and directed.
M&L for fixing only Geyser at new location, complete all as specified, directed and decided by Engr- in- Charge.
M&L for disconnecting and taking down the defective storage type water heater (Geyser) of 15 Ltr/25 Ltr/35 Ltr/50 Ltr capacity and refxing in same position after necessary repairs complete all as directed. Note:- The repairs and renewal parts will be measured & paid separately under the respective item of this schedule.
S&F in repairs heating element 2.0 KW capacity of appropriate shape suitable for storage type water heater (Geyser), complete all as specified and directed. Make:- As per sample.
All as per item No. 105 above but 1.5 KW capacity.
S&F in repairs repair thermostat of appropriate capacity and rating ISI marked suitable for 15 Ltr/25 Ltr/35 Ltr/50 Ltr capacity storage type water heater (Geyser), complete all as specified and directed. Suitable for Model Calena 25/2018 or other similar models.
S&F in repairs indicators with flexible cable cord, pin top by providing new indicator (Green/ Red) assembly with 3 core flexible cord of stranded copper conductor 2.5 Sqmm PVC insulated & over all PVC sheathed 1100 volts grade 1.5 m long duly connected to geyser with and including 3 pin top 15 Amp AC 230 V ISI marked suitable for 25 Ltr/35 Ltr/50 Ltr capacity Geyser, complete all as specified and directed.
S&F in repairs flexible hot water connection pipe with SS nuts heavy duty ISI marked internally metal coated suitable for fixing from outlet of water pipe to inlet of geyser and from geyser to inlet of hot water pipe and carrying hot water upto 70 degree centrigrate of length 600mm, complete all as specified and directed.
All as per item No. 111 herein before but 900 mm length.
S&F in repair anchor fastner stud bolt with nut and washer and pin (heavy duty) suitable for fixing of geyser to wall/ angle iron of length upto length 100/150mm, complete all as specified and directed.
S&F in repairs NRV by providing new cast copper alloy NRV 15 mm dia, complete all as specified and directed.
M&L for preparing old geyser of 25/35/50 Llitres capacity of any make by removing all dust, dirt, scale, scrapping out old patchy paint and applying two coats of synthetic enamel paint, complete all as specified and directed.
S&F in repairs safety valve for geyser of any cap/size, complete all as specified and directed.
S&F electric plug top 20 Amps 240 Volt, complete all as specified and directed.
M & L for copper wire connection 1 Sqmm with Al lugs suitable for Geyser Element, complete all as specified and directed. Make: As per sample.
M & L for copper wire connection 4 Sqmm 3 core suitable for AC/ Geyser Conneection, complete all as specified and directed.
S&F in repairs 20 watt LED 4 feet long with senser light fittings fixed on PVC square for mounting the fittings and electrically conncected with suitable size of PVC insulated multistranded copper flexible white colour cable from ceiling rose to light fitting (connector block of lamp fitting), complete all as specified and directed.
S&F in repairs inverter batten 18 watt 4 feet LED works on AC supply in normal mode and DC supply in inverter mode, with inbuilt battery back up of upto 4 hours, high efficiency, high lumes complete light fittings fixed on PVC square for mounting the fittings and electrically conncected with suitable size of PVC insulated multistranded copper flexible white colour cable from ceiling rose to light fitting (connector block of lamp fitting), complete all as specified and directed.
S&F in repairs LED inverter Lamp 12 watt works on AC supply in normal mode and DC supply in inverter mode, with inbuilt battery back up of upto 4 hours, high efficiency, high lumes complete light fittings fixed on PVC square for mounting the fittings and electrically conncected with suitable size of PVC insulated multistranded copper flexible white colour cable from ceiling rose to light fitting (connector block of lamp fitting), complete all as specified and directed.
Frends Enterprises (BID ID -3383845)
Accura Associates (BID ID -3391390)
B P ENTERPRISES (BID ID -3383876)
NOEL ENGINEERS (BID ID -3377878)
Rama Construction Co (BID ID -3380105)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .