Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹25.7 LAccepted-Finance | ₹25.7 L | 1 | Accepted-Finance ACCEPTED |
| 2 | 2₹27.1 L+₹1.4 L (5.52%)Accepted-Finance FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | ₹27.1 L+₹1.4 L (5.52%) | 2 | Accepted-Finance ACCEPTED |
| 3 | 3₹27.1 L+₹1.4 L (5.62%)Accepted-Finance | ₹27.1 L+₹1.4 L (5.62%) | 3 | Accepted-Finance ACCEPTED |
| 4 | 4₹29.2 L+₹3.5 L (13.6%)Accepted-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | ₹29.2 L+₹3.5 L (13.6%) | 4 | Accepted-Finance ACCEPTED |
| 5 | 5₹33.9 L+₹8.2 L (31.9%)Accepted-Finance PLOT NO 8 PREMA APARTMENT VEDANTNAGAR CHHATRAPATI SAMBHAJINAGAR 431 007 M S | CHHATRAPATI SAMBHAJINAGAR | CHHATRAPATI SAMBHAJINAGAR | MAHARASHTRA | 431007 | ₹33.9 L+₹8.2 L (31.9%) | 5 | Accepted-Finance ACCEPTED |
Tender Value
Refer Docs
EMD Value
₹46,000
Closing Date
29 Sept 2020, 3:00 pmClosed
GE I R AND D GIRINAGAR PUNE 411025
GE I R AND D GIRINAGAR PUNE 411025
REPAIR AND MAINT OF HT LT OH LINES UG CABLES TRANSFORMERS VCB GODS LT PANEL MCCB ACB STREET LIGHTS SECURITY LIGHTS GATE LIGHTS GARDEN LIGHTS AND ALLIED WORKS AT VRDE AHMEDNAGAR
2020_MES_373763_1
GE I R AND D TOKEN 36 OF 2020 21
Open Tender
Civil Works
Works
180 days
GE I R AND D GIRINAGAR PUNE 411025
REPAIR AND MAINT OF HT LT OH LINES UG CABLES TRANSFORMERS VCB GODS LT PANEL MCCB ACB STREET LIGHTS SECURITY LIGHTS GATE LIGHTS GARDEN LIGHTS AND ALLIED WORKS AT VRDE AHMEDNAGAR
6 documents required · 6 mandatory
₹500
GE I R AND D GIRINAGAR PUNE 411025
₹46,000
Yes
7 Oct 2020
1 Sept 2020
6 Oct 2020
1 Sept 2020
29 Sept 2020
15 Sept 2020
1 Sept 2020 - 12 Sept 2020
Amount
Excavation in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for poles, laying of electric cable and GI tubing (where provided for protection of cables) and getting out trimming the sides, forming bottom surface to required level in soft/loose soil complete all as specified and as directed.
Returning, filling in , including spreading, leveling, watering and well ramming in layers not exceeding 25 centimetre thick after laying and testing of cable complete all as specified and as directed.
Removing excavated material not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Material and labour for spread well dried sand cushioning in trenches complete all as specified and as directed. (Note:- Thickness of sand cushioning shall be measured punned thickness for the purpose of payment)
Dismantling of cross arms of MS channel or angle section etc.complete all as specified and as directed.
Supply and fix in replacement pin type porcelain, vitreous, white brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height 150mm dia for 11KV grade complete all as specified and directed.
Supply and fix inreplacement disc type insulator, porcelain, vitreous, white, brown or green 145 mm height and 255 mm dia ball and socket type single disk assembly for tension with tension clamp for conductor working pressure 11 KV grade complete.
S & F in replacement post insulator 11 KV for DO FUSE/ AIR BRAKE ISSOLATING switch. Make Jaipuria/rastriya/pactil
Supply and fixing in replacement LT Pin type, porcelain, vitreous, white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 100 mm height 65 mm dia for 1100 volt grade complete all as specified and as directed.
Supply and fixing in replacement shackle type, porcelain, insulator for working pressure 1100 volt with hardware fitting bolt, washers, nuts etc height 100mm dia 115 mm complete all as specified and as directed.
Supply, fabricating and fixing in repair mild steel cross arms bracings supports, D-clamps, back plates, clamps fabricated from structural steel section such as angle iron, channel, plate and flats etc including bolts, washers, welding, bending cold or hot , drilling holes for bolts , in any shape or size including two coats of synthetic aluminium paint over a coat of red oxide primer after preparation of steel surface complete all as specified and as directed.
M & L for taking out all electrical connections from LT panel and taking out the cable loop of any size of cable & checking the cable thoroughly including cleaning , cutting & removing the defective portion including provide new Alu lugs and re-fixing the cable in LT panel and relaying cable loop properly and testing complete all as specified and directed. Note : Cost of Alu lugs, labour for earth work deemed to be included in the quoted rate.
Repairs to LT panel board any size outdoor/indoor type by removing the U/S door hinges and S&F new door hinges of suitable size by welding including levelling the door by removing bends/dents and aligning the door for proper closing complete all as specified and directed by Engr-in-Charge.
M&L for painting with spray pump of LT panel Indoor/outdoor any size any type from outside with two coat of synthetic enamelled paint (colour approved by Engr-in-Charge) over a coat of red oxide and cleaning of LT panel MCCB's terminals and LT panel from inside with air blower and waste cloths complete all as specified.
M&L for painting to LT MS tubular Pole 8.5/9 mtr long with two coats of synthetic enamelled aluminium paint with synthetic enamel paint over prepared surfaces complete all as specified and directed.
M&L for painting to HT MS tubular pole 11 Mtr long with two coats of synthetic enamelled aluminium paint incl cross arms (for single pole), clamps etc. complete all as specified and directed.
M&L for painting of HT 11 Mtr long 6 pole structure with two coat of synthetic enamelled aluminium paint including channel, clamps & accessories in erected position and 1.2 mtr height from ground level in alternate band of approved colour with synthetic enamel paint over prepared surfaces complete all as specified and as directed.
All as above item No - 17 but 4 Pole structure.
All as above item No - 17 but 2 Pole structure.
Taking down old UNSV GI tubing and M &L for GI pipe light grade, for road crossing / on wall / on pole for cable protection of 40 mm dia.
All as per above item No-20 but 50 mm dia.
All as per above item No-20 but 100 mm dia.
Taking down the existing defective LT UG cable of 4 sq mm x 2/3/3.5/4 core upto 70 sqmm x 3/3.5/4 core in trenches / pipes / pole all as specified and as directed .
All as per above item No -23 but 95 to 150 sq mm x3.5 core.
Taking down the existing defective HT UG cable of following size in trenches / pipes / pole complete all as specified and directed . (a) 95 sq mm 3 core upto 185 sqmm 3 core.
Supply, laying, jointing and testing of under ground electric cable, XLPE sheathed HT 11000 volts, grade, heavy duty, armoured with aluminium multi stranded conductor cross sectional area of cable 95 Sqmm, 3 core conforming to IS laid in trenches, under floor, through the roads fixed along wall/pole/GI pipe complete all as specified and as directed.
Supply, laying, jointing and testing of under ground electric cable, XLPE sheathed LT 1100 volts, grade, heavy duty, armoured with aluminium multi stranded conductor cross sectional area of cable 150 Sqmm, 3.5 core conforming to IS laid in trenches, under floor, through the roads fixed along wall/pole/GI pipe with proper clamps complete all as specified and as directed.
All as per above item No-27 but 120 Sqmm, 3.5 core.
All as per above item No-27 but 95 Sqmm, 3.5 core.
All as per above item No-27 but 70 Sqmm, 3.5 core.
All as per above item No-27 but 50 Sqmm, 3.5 core.
All as per above item No-27 but 35 Sqmm, 3.5 core.
All as per above item No-27 but 25 Sqmm, 4 core.
All as per above item No-27 but 16 Sqmm, 4 core.
All as per above item No-27 but 6 Sqmm, 2 core.
All as per above item No-27 but 4 Sqmm, 2 core.
Supply & Laying 50 mm outside dia double wall corrugated pipe (DWC) of HDPE ISI Mark for enclosing cable below ground / road surface, to a required depth, including suitable size coplers for jointing of pipe all as per site requirement
Supply & Laying 75 mm outside dia double wall corrugated pipe (DWC) of HDPE ISI Mark for enclosing cable below ground / road surface, to a required depth, including suitable size coplers for jointing of pipe all as per site requirement
Material and labour for dismantling old lightning arresters and Supply and fix lightning arrester NON LINEAR RESISTER type, complete with all fittings, transmission classes, discharge capacity 65 Kilo amps suitable for 11 KV out door type complete all as specified and directed including taking down the existing LA. Make : ELPRO or equivalent of BHEL/ PACTIL.
Supply & laying unreinforced precast concrete type 2 flat cable cover, class HV, type -1, flat, size 300 x 180 x 40 mm complete all as per SSR part-II.
Material and labour for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in base and surrounding the pole and stay complete all as specified and as directed.
Material and Labour for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in foundation for feeder pillars, LT Panel and coping of poles including necessary form work and fair finished to exposed surfaces without using extra cement complete all as specified and as directed.
Supply and fix in replacement of switch air break gang operated triple pole mechanically operated mounted on HT insulator (09 insulator , Vertical type) and MS galvanised steel frame with operating mechanism worked from ground level including operating rod for current rating up to 400 amps, 11000 volts complete with 6 lever pad locking arrangements, MS Clamp, nuts, bolts and washers etc including two coats of aluminium paint over a coat of red oxide primer on MS work complete all as specified.
Supply and fixing in replacement drop out fuses HT, 11 KV Triple pole, rating 100 amps with base frame and insulator complete all as specified and as directed.
Material and labours earthings complete with galvanized steel earth plate electrode 600 mm by 600 mm by 6 mm thick, buried directly in ground (Earth pit not less than 2.25 metres deep below ground level) , surrounded from all direction with charcoal dust and salt in layers, the top edge of the earth plate not less than 1.5 metre below ground level, connected to galvanized iron strip 32×6mm as earthing lead and 40 mm bore GI pipe light grade for protection of GI strip. fixed by means of bolts, nuts and washers of galvanized iron and connected to earth test point and equipment and testing on completion including excavation and earthwork in any type of soil, PCC chamber in 1 :2:4 using 20 mm graded stone aggregate, CI cover, 20 mm GI pipe light grade for watering, funnel, wire mesh complete all as specified and shown on electrical plate No 5 of MES Schedule Part ‘I’( 1991). Note - Cost of GI Strip up to 7.5 RM is deemed to be included in the quoted rate.
Taking down old/UNSV pole and Material and labour steel tubular swaged poles complete with cast iron base plate, finial topper plug, bolts, nuts & screws as specified type 410 SP-31 (9 mtr long) and providing two coats of aluminium paint over a coat of red oxide primer (up to full height of pole excluding the planting depth and portion embedded in PCC and copping) complete all as specified and directed by Engr-in- Charge.
Supply and fix in repairs Time switch daily dial 240 v AC Base mounting type Make GIC Type FM/1 QT Cat No:J648B1 or equivalent of Havells/legrand/C&S.
Supply and fix in repairs Programmable time switch 24 Hrs, 240 volt complete Make GIC or equivalent of Havells/legrand/C&S.
Supply and fix in repairs Power contactor 3 pole, MNX 110 , 415 V 110 Amp. Make L&T or equivalent of GE/SIEMENS.
Supply and fix in repairs Power contactor 3 pole, MNX 225 , 415 V 225 Amp. Make L&T or equivalent of GE/SIEMENS.
Supply and fix in repairs Power contactor ML3 type, 415 V, 40 A :- Make L&T or equivalent of GE/SIEMENS.
Supply & Fix in repairs Power contactor TPN, 415 volt, 10 Amps Model: 3TF30 10-0 A Make : SIEMENs or L&T/GE.
Supply & fix in repairs power control relay 3.2 to 5 Amps, Cat No- 3UA50 00 1F Make : SIEMENS or equivalent to L&T/GE.
Supply and fix in repairs MCB SPN 40 A, 230 volt.
Supply and fix in repairs MCB TPN 40 A, 415 volt.
Supply and fixing in replacement MCCB, 200 amps, FP 415 volt, 36 KA capacity with suitable terminals in existing LT panel including drilling hole, nut bolt and washers and making electrical connections complete all as specified and as directed.Make : L&T/Indoasian/standard/Havells.
All as per above item No-56 but 100 Amps, TP, 25 KA.
All as per above item No-56 but 63 Amps, TP, 25 KA.
Supply & fix heat shrink cable jointing kit for 1.1 KV grade cable for straight through joint kit complete with jointing material and accessories suitable for 2/3.5/4 core XLPE / PVC armoured Aluminium Conductor cable of size 16 Sqmm to 35 Sqmm. Make: DENSON / MAHINDRA / REYCHEM / 3M ( m -seal cable jointing kit). Note:- Earth work will be measured and paid separately.
All as per above item No-59 but 50 Sqmm to 95 sqmm 3.5Core.
Supply and fixing in replacement of heat shrinkable end termination out door joint kit of 3 core 95 sqmm suitable for 11000 volt with accessories and testing complete all as specified and as directed by Engineer in charge.
All as per above item No-61 but size 120 to 185 Sqmm.
Supply and fixing in replacement of heat shrinkable straight through joint kit of UG cable 3 core 95 sqmm to 120 sqmm suitable for 11000 volt with accessories and testing complete all as specified and directed by Engineer in charge. Note:- Earth work will be measured and paid separately.
Dismantling of old/rusted aluminium conductor steel reinforced of any size and removing the same from site of work all as specified and directed by Engineer-in-Charge.
Material and labour for replacement of aluminium conductor steel reinforced [ACSR] straining properly on insulators and binding with aluminium tape/binding wire, connectors, jumpers etc on required places complete all as directed by Engr-in-charge.
Material and labour for painting of transformer complete with radiator of capacity up to 500 KVA, 11/.433 KV outdoor type with two coat spray painting with synthetic enamelled gray paint after preparation of transformer surface complete all as specified and directed.
Restringing of existing ACSR conductor of LT/HT OH line on PCC/steel tubular poles properly on insulators and rebinding with aluminium binding wire connectors, jumpers etc complete to the entire satisfaction of Engineer-in-Charge.
Supply, installing, commissioning and testing of cubical outdoor type factory made double door , powder coated LT bus bar feeder pillar box for 100 amps 3ph and neutral arrangement of size 500mmx500mmx200mm complete weather proof and vermin proof conforming to IP-54 made out of 1.6 mm thick CRCA sheet including provisions for ventilation and cable termination alley all as per IS complete including PCC foundation all as specified and as directed by Engr-in-charge.
Cutting, trimming and vending tree branches falling on overhead head lines after arranging electrical shutdown from department or MSEB including taking all precautions while working on lines. [Note:- (i) The length of span between two poles shall be measured in which trees are falling on overhead electric conductors. (ii) Required T & P will be arranged by the contractor at his own cost.
Dismantling of old jumper, including supply and fixing new jumper connection at cut point on HT over head line with suitable size of ASCR conductor 6 / 1 x 3.00 mm (ferret/weasel) PG Clamps, lugs, alkathine sleaves,galvanised nut and bolts complete of required length not exceeding 3 mtr including testing on completion complete all as specified and as directed by Engineer - in - Charge.
Disconnecting and dismantling the ACB breaker rating 400 to 800 Amps make Crompton Greaves/C&S/ L&T by carrying out repair/ servicing , checking and renewing the defective shunt trip coil & UV trip 415 V AC , checking and rectifying the defective CTs and rectifying the mechanism operation including spring charge system, reinstalling the same in the panel and providing necessary line and connections all as directed by Engineer-in-charge.
Surface excavation not exceeding 30 cm deep in hard and dense soil and state and getting out green vegetation, roots, bushes, etc surrounding of pole structure / substations / pump house as directed by Engr-in- charge.
Material and labour for cutting of bituminous road / floor for laying of pipe / cables not exceeding 20cm wide and not exceeding 30 cm deep including refilling with material and, watering well ramming / compacting and making good with premixed bituminous macadam, 100mm thick complete all as specified and directed by Engr-in-Charge.
Servicing and alignment of existing 11 KV GOD by cleaning the contact / pin insulator with CTC & applying the petroleum jelly at the contact, replacement of jumpers as required ,adjusting the down rod links for smooth operation including replacing the rusted/ corroded bolts & nuts and defective insulator / contacts /copper strip of GOD as required at site. Note :-( 1) Insulator /contacts /copper strip shall be measured and paid under relevant items.
Supply Male / Moving contact ( set of 3 Nos )
Supply Female / Fixed contact ( set of 3 Nos )
Supply Copper tinned strip ( set of 3 Nos )
S&F in replacement of 3 phase LED voltmeter Cl 0.5 with suitable accessories and fixing arrangements. Make : L&T or equivalent of standard/ABB.
S&F in replacement of 3 phase LED Ammeter Cl 0.5 with CTs and suitable accessories and fixing arrangements. Make : L&T or equivalent of standard/ABB. .
S&F in replacement of LED type phase indicator pilot lamp with transformer to be fitted on panel ( R,Y , B as per site requirement)
Disconnecting all the electrical connections from H.T.and L.T. side of unserviceable transformer of capacity up to 160 KVA i.e. Jumpers/cable from the cable end box or bushings & earthing terminal of the transformers, loading and unloading of transformer & transportation by vehicle from substation to the repairing workshop including reinstallation, commissioning and testing complete.
Disconnecting all the electrical connections from H.T.and L.T. side of unserviceable transformer of cap above 160 KVA to 500 KVA i.e. Jumpers/cable from the cable end box or bushings & earthing terminal of the transformers, loading and unloading of transformer & transportation by vehicle from substation to the repairing workshop including reinstallation, commissioning and testing complete.
Opening the transformer cover rating up to 160 KVA along with the conservator by removing the nut bolts then after removing the internal HT.& LT connections by taking them out by removing studs, bushings, taking out the core-winding assembly out of the tank of transformer having ratio 11/0.433KV, draining & decanting of transformer oil and cleaning of sludge deposited in the tank with CTC for the transformer. Heating of core winding assembly in hot chamber for 48 hours and remove all the moisture present in it , removal of leakage of tank if any by welding, refilling transformer oil in to the tank after dehydration / filtration and checking of dielectric strength of oil , after putting the core-winding assembly into the tank, reassembling making the internal H.T. & L.T. connections by fixing the studs, bushings, fitting the top cover by replacing cork sheet gasket along with conservator, testing the transformer in the workshop duly filled with oil, all as directed by Engineer-in-charge. Note : U/S items required for repairs shall be measured and paid under relevant item of this schedule. Transformer oil if required with die electric strength not less than 40KV either new or filtered shall be filled and shall be measured and paid separately under respective item.
All as per above item No-83 but of capacity above 160 KVA to 500 KVA
Supply only super enamelled copper winding wire / strip of any size for HT coils of transformers
Supply only copper winding strip of any size for LT coils of transformers including providing insulation all as required.
Reconditioning of LT coil of copper wound transformer by turning the old paper insulations, straightening the entire LT Strip providing new paper insulations of superior quality and making coil of suitable design as original all as specified and directed by Engr-in-Charge.
Supply & fix in repair LT insulation bushings 433V of suitable size for outdoor type transformer of capacity up to 160 KVA.
All as per above item No- 88 but above 160KVA up to 500 KVA
Supply & fix in repair HT insulation bushings 11 KV of suitable size for outdoor type transformer of capacities up to 160 KVA.
All as per above item No- 90 but above 160 KVA up to 500 KVA
Supply & fix in repair brass stud (for LT 433V side)of suitable size complete with one chuck nut, two nuts, washers and rubber seal, all as per sample for outdoor type transformer of the capacity up to 160KVA
All as per above item No- 92 but above 160 KVA up to 500 KVA
Supply & fix in repair brass stud (for HT 11 KV side) of suitable size complete with one chuck nut, two nuts, washers and rubber seal, all as per sample for outdoor type transformer of the capacity up to 160KVA
All as per above item No- 94 but above 160 KVA up to 500 KVA
M&L for disconnecting the transformer of capacity 50 KVA to 100 KVA and taking out the complete HT/LT cable/ Jumper connections and terminal box by removing all nuts/bolts/gasket etc.. Cleaning the HT and LT bushings and terminals etc. and inspecting for any damaged winding or any loose connections, leakages of oil, tightening the clamps, and checking the winding for its proper functioning and reassembling by replacing a new gaskets of required size and shapes including draining, refilling of transformer oil and reconnecting HT and LT connections and testing & commissioning complete all as specified. Note : (i ) HT/LT bushings will be measured and paid separately under relevant item.
All as per above item No-96 but capacity 150 to 200 KVA.
All as per above item No-96 but capacity 250 to 315 KVA.
All as per above item No-96 but capacity 400 to 500 KVA.
M&L for refilling / top up the transformer oil low viscosity conf to IS 335:1993 filtered of all as directed and sample of oil duly tested for di elect strength not less than 45 KV at 2.5 mm gap.
M&L for filtration/ dehydration of transformer oil ON LINE through mobile stream line transformer plant at site and testing of sample of transformer oil before and after filtration for di electric strength up to 45 KV at 2.5 mm electrode gap .
Opening of transformer and taking out old unserviceable tap changer and supply & installed new tap changer complete suitable for transformer outdoor type capacity up to 500 KVA.
Supply and fix in replacement oil temperature gauge meter suitable for transformer up to 500 KVA transformer.
M & L for replacement of breather assembly of transparent plastic body with top and bottom portion pressed with metallic cover, filled with silica jel blue in colour and suitable for pipe entry of 15/20/25mm dia as per the site requirement, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement of unserviceable existing HPSV/HPMV/tube light fitting of any wattage on existing poles with LED Flood light 50 W IP 66 complete all as specified and as directed. Make-Crompton Cat No- LFLE-50-CDL or equivalent of Havells/philips/Wipro.
S & F in repair pole mounting boxes( DB) factory made of FRP heavy duty internal dimention not less than 250x200x105mm. Make Sintex or National ISI marked comprising with the following :- (a) MCB SP 1 Amps 240 Volts-01 Nos (b) Three phase copper connector on porcelain insulators complete including suitable size of MS clamps as per site requirement - 02 Nos, nut and bolts etc.all as directed by Engr In Charge.
S & F in repair pole mounting boxes( DB) factory made of FRP heavy duty internal dimenion not less than 155x155x100mm. Make Sintex or National ISI marked comprising with the following :- (a) Three phase copper connector on porcelain insulators complete including lugs and suitable size of MS clamps as per site requirement - 02 Nos, nut and bolts etc.all as directed by Engr In Charge.
Supply & fix in replacement LED 10 W decorative garden light LED bollard in round/squared shaped with opel acrylic diffuser and aluminium reflector IP 65 protection includes necessary PCC cylinderical foundation with PCC 1:2:4 height not less than 30cm and dia 25cm above from ground for fixing of light fitting including connector and necessary electrical connections etc. all as specified and directed. Make-Crompton Cat part No- LBLSR-10-WW or equivalent in Havells/Philips/Wipro
Supply and fixing in replacement street light mounting bracket made out of GI pipe 40 mm dia 'medium Grade' not less than with 0.75 m. long in any shape with 2 nos of clamps made out of MS flat of size 40 x5 mm and nuts and bolts all as directed by Engr-in- Charge.
Supply, installation, testing and commissioning in replacement of street light panel outdoor type on wall/pole comprising with Digital 24 Hrs timer-01 Nos, contactor 65 Amps, TP -01 Nos, MCB TPN 63 Amps -01 Nos complete with necessary electrical connections. Make : Havells Cat part No - IHXTS09120 or equivalent of L&T/Legrand.
Supply, installation, testing and commissioning in replacement of Street light panel outdoor type for Digital 24 Hrs time switch with 32 Amps 3 phase 415 Volt contactor, suitable relay and 40 Amps SPN MCB for automatic switch on and switch off ( Make - Havells Cat Part - IHXSS01060, or equivalent of L&T / Legrand) .
Supply and fixing in replacement of unserviceable existing HPSV/HPMV/tube light fitting of any wattage on existing poles with LED security light 60 W IP 66 complete all as specifed and directed by Engineer-in-charge. Make- Crompton Cat No- LSTP-60-CDL or equivalent of Havells/Philips/Wipro.
Supply and fixing in replacement of unserviceable existing HPSV/HPMV/tube light /LED lamp fitting of any wattage on existing poles with LED flood light 200 W IP 66 pressure die cast aluminium housing for large area lighting complete including suitable MS clamps, nuts & botls with necessary electrical connection. Make- Crompton Cat Part No- LSFO-200-CDL/60 or equivalent of Havells/Philips/Wipro.
Supply & fix in replacement of unserviceable existing HPMV/HPSV post top lantern with LED 40 W decorative post top lantern, made in cast aluminium with decorative opal polycarbonate diffuser with IP 65 protection including minor fabrication on top of existing pole according to luminaire dia all as directed and specified by Engr-in-charge. Make- Crompton Cat Part-LPTO-40-CDL/M or equivalent in Havells/Philips/Wipro.
M &L for GI pipe 40mm bore "Medium grade" for mounting of post top lantern, including cutting, fabricating and welding of suitable length as directed by Engr-in-Charge.
Supply and fix in replacement electronic driver for LED street light fitting 45/60/90 Watt as per sample/existing fittings complete.
Supply and fix in replacement of 1 Sqmm 3 core PVC insulated stranded copper cable from pole junction box to fitting all as directed by Engr-in-Charge.
Supply and fix in replacement of PVC conduit 20 mm external dia medium grade for street light from pole box to fitting with propper clamping all as specified and as directed by Engr-in-charge.
M&L for carrying out the servicing of DG set make Kirloskar complete all as per manufacturer's instructions and all as directed by the Engineer-in-Charge by replacement of the following parts of 250 KVA Capacity DG Set including carrying out minor addition/alternation and supply and fixing the parts for smooth functioning of DG Sets at Tech area. Make : Kirloskar [a] Element fuel filter with 'O' ring - 2 Nos. [b] All Oil filter element. [c] Element air cleaner (Inner & Outer)- 1 Nos. [d] Checking and correcting up of water pump for excess play. [e] Cleaning and tightening of all electrical connections of DG sets upto the entire satisfaction of the Engr-in-Charge. [f] Cleaning of entire DG sets with proper cleaning material upto the entire satisfaction of the Engr-in-Charge. [g] Checking and tighting inlet & exhaust manifold bolts & nuts. [h) Taking down and cleaning and servicing of radiator from inside and outside throughly with cleaning solution and refixing the radiator assembly properly. [j] Replacing the radiator hose pipe with suitable size with clamps. [k] Checking and making good vibration dampner. [l] Checking and correcting of inlet/exhaust valve, valve guide with grinding of valve and grinding of injector Nozzles and cleaning of head and calibration of rocker arm and refixing with head gasket.
All as per item No.119above but DG set capacity 160 KVA at NCAT area. Make : Kirloskar.
All as per item No.119 above but DG set capacity 50 KVA at NCAT area. Make : Cummins
All as per item No.119 above but DG set capacity 30 KVA at SVD Shed. Make : Cummins Note for item No 119 to 122 : Servicing and all above mentioned jobs will be carried out by authorised manufacturer's representative only to the entire satisfaction of the Engineer-in-Charge. Engine Oil, coolent will be measured and paid as separate item.
Dismantling the fuel injection pump assembly for overhauling and repairing by replacing of worn out parts such as gasket diaphragm etc complete all as directed and calibration of FIP and refixing the same having capacity 250 KVA DG set. Make Kirloskar
All as per item No. 123 above but capacity 160 KVA DG set.
Supply and replace the injector nozzles for 160 KVA to 250 KVA DG set suitable for Kirloskar Engine.
Supply and replace water pump assembly suitable for 250 KVA capacity suitable for Kirloskar DG Set.
All as per item No. 126 above but suitable for capacity 160 KVA suitable for Kirloskar Engine.
Supply and replace the V fan belt heavy duty for water pump of capacity 160 KVA to 250 KVA Kirloskar Engine.
S & F V fan belt for alternator of capacity 160 to 250 KVA DG Set.
Repairs and overhauling of self starter complete including replacement of all worn out parts, bushing contact assembly complete after dismantling and refixing the same after repairs all as specified and directed by the Engineer-in-Charge
Supply and fixing in replacement of battery 150 AH, 12 V DC with initial charged, battery terminals and lead, proper filling of Sulpuric acid, and distilled water complete all as specified and as directed by Engr-in-Charge. Make - Exide/Amron.
Supply and replace the battery copper lead of 70 Sq mm size having 1.5 M length suitable terminal complete.
All as per item No. 132 above but having 30 cm length
Supply and filling in sump / topping up engine oil, multi grade 15w/40 in engine or replacement of engine oil Make: Indian oil / Hindustan petrolium / Castrol
Supply and filling electrolyte of suitable Sp gravity for lead acid batteries in sealed containers
M&L for coolent of DG Set.
Supply and fix in repair fuel pipe steel braided, steel stranded with benzo bolts and washers etc complete of length 30 cm long.
Supply and fix in repair fuel pipe steel braded, steel stranded with benzo bolts and washers etc complete of length 45 cm long.
Supply and fix in repair fuel pipe steel braded, steel stranded with benzo bolts and washers etc complete of length 60 cm long.
Supply and fix in repair fuel level indicator transparent PVC pipe of suitable dia for fuel level in tank.
Supply and fix in repair solenoid switch vertical/ horizontal type capacity upto 160 KVA DG set.
M&L for Repair to Radiator assy by disconnecting the radiator from engine frame and servicing/cleaning with acid and brazing where required to stop leaking tubes/joints etc. cleaning fins and refixing the same for DG set 160 KVA to 250 KVA all as directed by Engineer-in-Charge.
Dismantling the defective alternator of 160 KVA DG Set from the existing foundation and from Engine after removing all electrical connections, transporting to approval/ authorised / directed workshop, opening and taking out burnt winding, cleaning the stator assy and rewinding with super enamelled copper wire as per existing gauge as per original manufacturer and applying insulating varnishing of 'F' class, baking in oven reassembling the alternator, transporting back to site re-installing the same position, carrying out alignment of complete DG set connecting up all electrical connections testing and commissioning complete. Note : (i) Rate quoted shall be deemed to be included of making good the disturbed surfaces. (ii) The DG set shall be tested on load as per rated capacity for the satisfaction of Engr-in-charge.
Dismantling the defective alternator of 160 KVA DG Set from the existing foundation and engine after removing all electrical connections, transporting to workshop rewinding the burn out coil complete with super enamelled copper wire, applying insulating varnish of 'F' class, baking in oven, reassembling the alternator, transporting back to site, reassembling the same carrying out alignment of complete DG set, connecting up all electrical connections, testing & commissioning complete .
Supply, installation, testing and commissioning of LT panel board (CPRI Approved) for Scientist Hostel, made out of 3.15mm thick CRCA sheet steel enclosure OUTDOOR cubical type, double door with aprons, dust, vermin, weather proof duly powder coated with seven tank process and all as per IE rules,mounted on angle iron of size 50x50x6mm with two coats of black synthetic enamel paint over a coat of red oxide primer and height from ground level not less than 50 Cm including grouting with PCC 1:4:8 type D2 40 mm graded stonre aggregate including necessary excavation and earth work complete with necessary compartments, fitted with 4 Nos TPN of aluminium bus bar 600 Amps with colour code sleeves mounted on porcelain/SMsC/DMC insulators, including internal control wiring with PVC insulated copper wire of suitable size and panel shall have comprise/including of following items :- (a) Bus Chamber : (i) Aluminium Busbar 600 Amps rated - 04 Nos (b) INCOMING :- (i) MCCB 400 Amps, 4 Pole, 415 volt, 36 kA with thermal magnetic release - 01 Nos (c) OUTGOING :- (i) MCCB 100 Amps, 3 Pole, 415 volt, 25 kA with thermal magnetic release - 04 Nos (ii) MCCB 200 Amps, 3 Pole, 415 volt, 25 kA with thermal magnetic release - 01 Nos (iii) Changeover "ON LOAD" type 400 Amps, 415 Volt, 4 pole - 01 Nos (iv) Indication LED set of three (RYB) with integral circuit 01 Set for Incomming and 05 set for outgoing - 06 Set (v) 3 Phase LED Voltmeter - 01 Nos (vi) 3 PhaseLED Amp Meter with CT's. - 01 Set (vii) Spare Space with mounting rail for MCB TPN -02 Nos. Note :- Cost of Cable glands, MCCB spreader terminals, cable lugs etc is deemed to be included in the quoted rate. Panel should be spacious for easy maintenance and cable connections etc.
Supply, installation, testing and commissioning of LT panel board (CPRI Approved) for office area, made out of 3.15mm thick CRCA sheet steel enclosure OUTDOOR cubical type, double door with aprons, dust, vermin, weather proof duly powder coated with seven tank process and all as per IE rules,mounted on angle iron of size 50x50x6mm with two coats of black synthetic enamel paint over a coat of red oxide primer and height from ground level not less than 50 Cm including grouting with PCC 1:4:8 type D2 40 mm graded stonre aggregate including necessary excavation and earth work complete with necessary compartments, fitted with 4 Nos TPN of aluminium bus bar 400 Amps with colour code sleeves mounted on porcelain/SMsC/DMC insulators, including internal control wiring with PVC insulated copper wire of suitable size and panel shall have comprise/including of following items :- (a) Bus Chamber : (i) Aluminium Busbar 400 Amps rated - 04 Nos (b) INCOMING :- (i) MCCB 200 Amps, 4 Pole, 415 volt, 36 kA with thermal magnetic release - 01 Nos (c) OUTGOING :- (i) MCCB 63 Amps, 3 Pole, 415 volt, 25 kA with thermal magnetic release - 05 Nos (ii) Indication LED set of three (RYB) with integral circuit 01 Set for Incomming and 05 set for outgoing - 06 Set (iii) 3 Phase LED Voltmeter - 01 Nos (iv) 3 PhaseLED Amp Meter with CT's. - 01 Set (v) Spare Space with mounting rail for MCB TPN -03 Nos. Note :- Cost of Cable glands, MCCB spreader terminals, cable lugs etc is deemed to be included in the quoted rate. Panel should be spacious for easy maintenance and cable connections etc.
SKS Electricals
KAMINS CARE
Mayur Enterprises
ASHWAMEDH ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .