Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.6 LAccepted-AOC 482 GALI NO 4 TULSI VIHAR AZAD NAGAR HISAR 125001 | HISAR | HISAR | HARYANA | 125001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.4 L+₹78,772 (12.0%)Rejected-Finance | L2 | Rejected-Finance L | |
| 3 | L3₹7.7 L+₹1.1 L (16.3%)Rejected-Finance 1350 B SHYAM LAL BAGH NEAR NAND CINEMA HISAR 125001 | HISAR | HARYANA | 125001 | L3 | Rejected-Finance L3 |
Tender Value
₹5.6 L
EMD Value
₹11,280
Closing Date
5 Jan 2021, 5:00 pmClosed
Executive Engineer Electrical PWD BandR BR. Hissar
Executive Engineer Electrical PWD BandR BR. Hissar
RENOVATION OF BUS STAND AT HANSI IN DISTT. HISAR (PDG. ELECTRIFICATION).
2020_HRY_154074_1
PWD/Elect-GGN/Elect-HSR/100112
Open Tender
Electrical Works
Works
120 days
Hissar
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
₹11,280
9 Apr 2021
24 Dec 2020
6 Jan 2021
24 Dec 2020
5 Jan 2021
24 Dec 2020
Amount
Main Switches: Supply and erection of metal clad switches / B.D.Bs with rag bolts on wall or on existing angle iron board / pedestal including bonding to earth and necessary connections. (HSR 31.12 (a). xiv) Triple pole switch with neutral link 32 amp. 415 Volts Cat-B.
xv) Triple pole switch with neutral link 63 amp. 415 Volts Cat-B.
xvi) Triple pole switch with neutral link 100 amp. 415 Volts Cat-A
Moulded case Circuit breakers: Supply and erection of moulded case circuit breakers on wall or on existing pedestal including bonding to earth and necessary connections. (HSR 31.12 (C). i) 15 amp.to 60 amp. 415 V ,10 KA 3-phase.
ii) 100 amp.to 220 amp.415 V,10 KA 3-phase.
Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suiteble size of rag bolts with cement concrete ,duly painted with three coats of approved paint including one coat of red oxide. (HSR 31.13) ii) Size 40 mm x 40 mm x 6 mm.
M.S.Sheet (HSR 31.14) i) Supply and erection of 3 mm thick mild steel sheet duly welded on existing M.S. angle iron frame for fixing the main switches etc. as required, duly painted with three coats of approved paint including one coat of red oxide.
Distribution board with plug and socket: Supply and erection of sheet steel enclosure 2 pole / 3 pole with earth plug and socket suitable for incorporating single pole / triple pole MCB on wall / on existing pedestal complete with necessary connections etc. (HSR 31.15) S.P.N. enclosure for single pole MCB 20 amp.
Miniature Circuit Breaker and Isolator: Supply and erection of miniature circuit breaker / isolator 240 /415 V in the existing distribution board including making necessary connections. (HSR 31.17) Miniature circuit breakers of 9 KA breaking capacity. ii) SP MCB 6 amp. to 32 amp.
TPN MCB 6 amp. to 32 amp.
TP MCB 6 amp. to 32 amp.
ix) TP MCB 40 amp. to 63 amp.
x) TPN MCB 40 amp. to 63 amp.
Supply and erection of Fittings and Accessories.(HSR 31.18) xi) Bakelite angle / straight button holder large size.
xii) Switch 5 amp. On existing sheet.
xiii) Wall socket 5 amp. On existing sheet.
xxiv) Erection only of 1x40 watts or 2x40 watts 1220 mm long / 1x20 watts or 2x20 watts ,610 mm long fluorescent tube fitting directly on wall including necessary connections with 0.75 sqmm ( 24 / 0.20 mm ) PVC copper flexible cable for connecting the tube with the adjacent point.
Pipe Laying: Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required. (HSR 31.21). xxi) Heavy guage welded conduit pipe 20 mm dia 1.60 mm thickness flushed.
xxii) Heavy guage welded conduit pipe 25 mm dia 1.60 mm thickness flushed
xxviii) For additional length of Galvanized iron flexible pipe more than 1 meter ( the payment is to be made for additional length of pipe more than 1 meter only in item no. xxvii ). c) Size 40 mm dia.
xxx) Supply and erection of PVC pipe of 6 kg. pressure laid 1 metre below ground level complete including digging refilling of the trench with jointing etc. c) PVC pipe 65 mm dia.
(Q) Earthing (HSR 31.22) i) Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosure on the top etc. as required .
ii) Extra for using salt and charcoal / coke for pipe earth electrode as required.
xix) Supply and erection of 20 mm x 3 mm thick G.I. tape fixed with suitable G.I. staples of same size.
Under Ground Cables: Supply and erection of under ground cable 1 metre below ground level covered with sand and bricks including necessary connections, digging and refiling of trenches. (HSR 31.25) xxvii) 50 Sq. mm 3.5 Core Ard. Cable .
Supply and erection of under ground cable ,loose in existing pipe or trenches complete with necessary connections. (HSR 31.26) xxvi) 35 Sq. mm 3.5 Core Ard. Cable.
xxxix) 10 Sq. mm 4 Core Ard. Cable .
xl) 16 Sq. mm 4 Core Ard. Cable.
xli) 25 Sq. mm 4 Core Ard. Cable .
Supply and erection of suitable compression type brass cable glands for underground Cable. (HSR 31.28) ii) 10 Sqmm to 16 Sqmm Cable 2 to 4 Core .
iii) 25 Sqmm to 50 Sqmm Cable 2 to 4 Core.
Street Light. (HSR 31.30): IV) Supply and erection of weather proof M.S.Box of size 20 cm x 15 cm x 10 cm. covered with 3.00 mm thick M.S.sheet hinged cover, locking arrangements , housed in wall , including the cost of 1 no. 16 amp. 415 volts kit-kat and 2 nos. 63 amp. 415 volts neutral links fixed on hard wood board in the M.S.Box including painting and necessary connections .
Miscellaneous (HSR 31.35): i) Supply of M.S.pipe (B-Class) for suspension rod of ceiling fan including threading if required. a) 15 mm dia
Wiring in existing Conduit pipe (Recessed) for Electrical points: Wiring only in 1.5sqmm PVC insulated copper conductor cable in existing conduit pipe and MS box covered with 5 mm thick bakelite sheet including cost of switch, wall shocket, celling rose etc. (HSR 31.38) a) Fan Point Medium
b) Fan Point long
a) Light Point- Short.
b) Light Point- Medium.
c) Light Point- Long
vii) 3 pin 5 amp. plug point including earthing the 3rd. pin etc.-Short point.
b) Medium Point
c) Long point
viii) 3-pin15 amp.Plug point with 4 sqmm PVC insulated copper conductor cable including earthing the 3rd pin etc. c) Long point
S/E of of PVC unsheathed copper conductor cable single core 1100 volts grad in pipe of suitable size excluding cost and erection of pipe. (HSR 31.40) i) Cable size 1.5 sqm(3/0.81 mm)
iii) Cable size 4 sqm(7/0.85 mm)
iv) Cable size 6 sqm(7/1.05 mm)
S/E of double door sheet steel enclosure distribution board suitable for MCCb and ELCBs recessed in wall including bonding to earth with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-Charge of the work. (HSR 31.41). v) 4-way,TP&N (Horizontal)(8+12)
x) 8-way,TP&N (Vertical)(8+24)
viii) 16-way,TP&N (Horizontal)(8+48)
Supply & erection of Socket size rotary step type Electronic regulator for A.C. ceiling fan Anchor make Deluxe model No. 50440 ISI / SSK make PC 561 operated on 120/280 V A.C. Supply complete including cutting of existing Bakelite sheet and making necessary connection etc. upto the entire satisfaction of the Engineer-in-Charge of the work. (HSR 31.55)
Non schedule Items: S/E of M.S. box for computer made of 16 guage of size 250mm x 200mm x 100 mm deep covered with 5 mm thick bakelite sheet white colour of ISI mark fixed by means of 4 nos .brass screws with cost of 1 No. 15 amp multi socket of ISI mark and 15 amp switch and 3 nos .5 amp multi socket with 5 amp switches of ISI mark including fixing the M.S. box in wall with cost of cement sand mixture including painting of M.S. Box and to complete the job in all respect upto the entire satisfatoin of Engineer-in- Charge of the work.
Non schedule Items: S/E of 120 W LED Flood light luminaries with high power LED < 120 Lumens per Watt Philips / Havell's / Bajaj/ Wipro make in aluminum pressure die casting housing toughened glass cover with IP-66 protection With Lense and dual surge protection device internal 5 KV and external 10 KV including all petty material with labour for errection, complete in all respect of Engineer-in-Charge of the work.
Non schedule Items: Supply and erection of Double door sheet, steel superline/ Powerline/ Loadline TPN Vertical distribution boards suitable for TP/ FP veritcal MCCBs 25 KA MCCB upto 125 amp as incomer (but without cost of MCCBs) fitted with busbars, Neutral links,& Blanking plates complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. (i) 4 Way vertical
INFERNO POWER AND SAFETY
pawan Kumar
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .