Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.2 LAccepted-AOC SHANTI KUNJ CHESIRE HOME ROAD BARIATU RANCHI 834009 JHARKHAND | RANCHI | JHARKHAND | 834009 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹26.6 L+₹43,370 (1.65%)Rejected-Finance 30 INDUSTRIAL AREA KOKAR RANCHI 834004 JHARKHAND | RANCHI | JHARKHAND | 834004 | L2 | Rejected-Finance Quoted amount is more than L1 | |
| 3 | L3₹27.2 L+₹1.0 L (3.87%)Rejected-Finance | L3 | Rejected-Finance Quoted amount is more than L1 | |
| 4 | L4₹29.7 L+₹3.5 L (13.3%)Rejected-Finance 00 PANCHARIYA NEAR SANTOSHI MATA TEMPLE MAHARASHI GOUTAM MARG NEW LINE GANGASHAHAR BIKANER BIKANER BIKANER RAJASTHAN 334401 | BIKANER | RAJASTHAN | 334401 | L4 | Rejected-Finance Quoted amount is more than L1 | |
| 5 | L5₹33.9 L+₹7.7 L (29.4%)Rejected-Finance 101 GROUND FLOOR RAJASTHALI ENCLAVE DUMARDAGA RANCHI JHARKHAND 834012 | RANCHI | JHARKHAND | 834012 | L5 | Rejected-Finance Quoted amount is more than L1 |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
14 Dec 2023, 6:00 pmClosed
Shri Sahil Ratusaria, IDSE
Garrison Engineer Ranchi, 7th Club Road Ranchi, PIN-834001
REPAIR/REPLACEMENT OF ELECTRICAL FITTINGS AND FIXTURES INCLUDING REWIRING AND CONNCETED ITEMS OF E/M WORK SERVICES FOR MH NAMKUM AND REPAIR/MAINT ELECTRIC GEYSERS (WATER HEATERS) AT NAMKUM, KHOJATOLI AREA UNDER GE RANCHI
2023_MES_628877_1
8400/1204/E8
Open Tender
Civil Works
Item Rate
180 days
Ranchi
Class D Cat b (i)
6 documents required · 6 mandatory
₹500
GE Ranchi
₹72,000
Yes
2 Feb 2024
18 Nov 2023
16 Dec 2023
19 Nov 2023
14 Dec 2023
1 Dec 2023
Amount
Taking down copper/aluminum point wiring (light fan, socket or power) complete including fittings such as switch, sockets, ceiling rose, pendents, regulators, sockets, light fittings, wooden boards, bell push, call bell, regulators etc (credit scheduled for above items should be made as per condition separately) and making good to disturbed wall and surface complete all as specified and directed.
M&L concealed conduit Point wiring with 1.5 Sq mm multistranded copper conductor FRLS PVC insulated and unsheathed cable ISI marked & drawing in and including non-metallic PVC conduit 20 mm bore medium grade & ISI marked on walls/ceilings/steel frame structure (with necessary arrangement as required at site) including cutting chasing for wiring , pinning in making good & finishing of disturbed surfaces,white wash matching with the existing surface colour & including all conduit fittings, clamps, gutties etc. Point to be for one light controlled by one switch , bell point controled by one bell point and fan point or one fan point controlled by one switch and regulator each including provision of new pressed steel terminal boxes not less then 1.6 mm thick; with provision of new 3 mm thick plastic laminated sheet of and PVC insulated stranded copper continuous earth wire 1.5 Sqmm size FRLS to common earth and connecting to earth dolly, complete all as specified and directed. (Switch/socket, regulators shall be measured & paid for separately). Note- All the wires will be used with approved colour coding, complete all as specified and directed.
All as per item Ser No 2 above but for 2 pin socket outlet 5 amp on the same board contraolled by separate switch complete all as specified and directed.
All as per item Ser No 2 above but for 2 pin socket outlet 5 amp independent but not below the main board In the same vertical plane complete all as specified and directed.
All as per item Ser No 2 above but with 2.5 sqmm copper conductor for 15 amp switch socket outlet combination including 1.5 sqmm copper earth wire complete all as specified and directed.
M&L PVC casing & Caping Point wiring with 1.5 Sq mm multistranded copper conductor FRLS PVC insulated and unsheathed cable ISI marked & drawing in and including in PVC casing & caping & ISI marked on walls/ceilings/steel frame structure (with necessary arrangement as required at site) including cutting chasing (if required) for wiring , pinning in making good & finishing of disturbed surfaces,white wash matching with the existing surface colour & including all in PVC casing & caping fittings, clamps, gutties etc. Point to be for one light controlled by one switch , bell point controled by one bell point and fan point or one fan point controlled by one switch and regulator each including provision of new pressed steel terminal boxes not less then 1.6 mm thick; with provision of new 3 mm thick plastic laminated sheet of and PVC insulated stranded copper continuous earth wire 1.5 Sqmm size FRLS to common earth and connecting to earth dolly, complete all as specified and directed. (Switch/socket, regulators shall be measured & paid for separately). Note- All the wires will be used with approved colour coding, complete all as specified and directed.
All as per item Ser No 6 above but for 3 pin socket outlet 5 amp on the same board contraolled by separate switch complete all as specified and directed.
All as per item Ser No 6 above but for 3 pin socket outlet 5 amp independent but not below the main board In the same vertical plane complete all as specified and directed.
All as per item Ser No 6 above but with 2.5 sqmm copper conductor for 15 amp switch socket outlet combination including 1.5 sqmm copper earth wire complete all as specified and directed.
M&L replacement of switch piano flush button type 6 Amp 240 Volt one way single pole complete all as specified and directed.
M&L replacement of bell push button type 5/6 Amp 240 Volt one way single pole complete all as specified and directed.
Supply and fixing Socket outlet 2 in 1, 3 pin, 5A complete all as specified and directed.
Supply and fixing Socket outlet 2 in 1, 5 pin, 15/16A complete all as specified and directed.
Supply and fixing Switch socket combination 2 in 1, 5 A flush type complete all as specified and directed.
Supply and fixing switch socket combination multi purpose 5/6 Amp /16 Amps, 5 in1, flush type complete all as specified and directed.
Supply and fixing electronic double space rotary step fan 5 speed socket type regulator 120- 280 Volts complete all as specified and directed.
Supply and fixing ceiling rose surface bakelite 3 terminals 65 x 50mm
Supply and fixing modular type switch 6 Amps, one way complete all as specified and directed.
Supply and fixing modular type switch 16 Amps, one way complete all as specified and directed.
Supply and fixing modular type Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed.
Supply and fixing modular type Socket, 6/16A - 2/3 pin combined 2 module, complete all as specified and directed.
Supply and fixing Modular Fan step regulator, 100/120W - 2 module Electronic step type complete all as specifed and directed.
Supply and fixing the White cover plate with frame 2 Module complete all as specified and directed.
Supply and fixing the White cover plate with frame 3 Module complete all as specified and directed.
Supply and fixing the White cover plate with frame 6 Module complete all as specified and directed.
Supply and fixing the White cover plate with frame 8 Module complete all as specified and directed.
M&L Buzzer, Ding Dong AC. 230 volts, single pole, complete all as specified and directed.
Supply and fixing LED light fitting,4 feet ,1x20 watt 230 Volt, 4Feet slim body with reflector,drivers,LEDs Astra is a surface & wall mounted LED batten complete with all accessories including LED Tubes internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed including taking down old fitting. Make- Phillips/CG/Havells/Bajaj
Supply and fixing LED Tube light fitting 2 feet 1x10 watt 230 Volt, 2 feet slim body with reflector,drivers,LEDs and , complete with all accessories including LED Tubes internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed including taking down old fitting. Make- Phillips/CG/Havells/Bajaj
S&F of LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed including taking down old fitting. Make- Phillips/CG/Havells/Bajaj.
Supply & fix the Square LED down lighter/wall mounted 15 watt fit at surface/Ceiling complete all as specified and directed and including taking down old fitting Make- Phillips/CG/Havells/Bajaj.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed/surface type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete and including taking down old fitting. Make- Phillips/CG/Havells/Bajaj
Supply and fixing LED building Security Light Fittings 18/20 watts of turbo street lights are made up of pressure die cast housing with integrated lenses and high power LED's with IP66 protection. Efficacy ≥ 100LPW and other connected accessories including service bracket of GI pipe 25/32 mm bore medium grade of length 0.9 mtr with MS clamps, bolts, nuts, and washers as per required at site and making electrical connection with Copper wire 2 core of 1 Sqmm and taking down old unserviceable light any capacity any type complete all as specified and directed and including taking down old fitting. Make- Phillips/CG/Havells/Bajaj
Supply and fix Electronic LED FTL rod 4 Feet capacity 20W complete and including taking down old tube rod.
Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified.
Supply and Fixing of Flameproof cum Waterproof LED Bulk Head light fitting of 15W, IP66 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen 'A' clear glass having Anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified.
Supply and fixing post top lantern LED type 20 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete complete all as specified.Make- Phillips/CG/Havells/Bajaj
Supply and fix PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable of size 0.75 Sqmm 2 core , 1100 Volt, conforming to IS 694 connecting up the light fittings, complete all as specified and directed.
Supply and fixing for sheet metal enclosure MCB DB, IP-43, SPN, 240 volts ,8 way, double door type grouted in wall in cement mortar 1:3 and making electrical connection, complete all as specified and directed and including taking down old DBs and take to schedule of credit. Make- Legrand/Havells/Indo Asian (optipro).
Supply and fixing MCB SP, 6 to 32 Amps, 240 volts, 10 KA, 'C' Curve characteristics, including taking out old unserviceable MCB/Isolator, electrical connections and removal from the site complete all as specified and directed. Make- Legrand/Havells/Indo Asian (optipro).
Supply and fixing MCB SPN, 32 Amps, 240 volts, 10 KA 'C' Curve characteristics, including taking out old unserviceable Isolator & electrical connection and removal from the site complete all as specified and directed. Make- Legrand/Havells/Indo Asian (optipro).
Supply and fixing MCB SPN 40 to 63 Amps, 240 volts, 10 KA 'C' Curve characteristics, including taking out old unserviceable Isolator & electrical connection and removal from the site complete all as specified and directed. Make- Legrand/Havells/Indo Asian (optipro).
Supply and fixing in replacement of TPN vertical type distribution Board, IP-43 protection, fitted with bus bars, neutral links, blanking plates (with out MCCB), 415 volts, 4 way double door type, grouted in wall in cement mortar 1:3 and making good of disturbed surface and matching with existing surface, complete all as specified and directed and including taking down old DBs and take to schedule of credit. Make- Legrand/Havells/Indo Asian (optipro).
Supply and fixing in replacement of MCCB, 4P, rated current 63 Amp, breaking capacity 16/18 KA thermal magnetic type and making electrical connection, complete all as specified and directed and including taking down old MCCB and take to schedule of credit. Make- Legrand/Havells/Indo Asian (optipro).
Supply and fixing in replacement of MCCB, 4P, rated current 100 Amp, breaking capacity 16/18 KA thermal magnetic type and making electrical connection, complete all as specified and directed and including taking down old mccb and take to schedule of credit. Make- Legrand/Havells/Indo Asian (optipro).
Supply and fixing sub-main wiring with two single core flame retardant PVC insulated and unsheathed cable with stranded copper conductor of 2.5 Sq mm drawing in & including medium grade PVC conduit pipe 20 mm bore ISI marked with all accessories on walls and making good of disturbed surfaces including all conduit fittings, clamps, gutties etc and one additional earth wire of 2.5 Sq mm but green in colour for earth DBs and boxes with proper thimbles connecting up and taking down old submain wiring complete all as specified and directed.(Note : Two run of wire and one run of earth wire drown in PVC conduit of 20 mm dia shall be measured as one RM).
Supply and fixing sub-main wiring with two single core flame retardant PVC insulated and unsheathed cable with stranded copper conductor of 4 Sq mm drawing in & including medium grade PVC concealed conduit pipe 20 mm bore ISI marked with all accessories on walls and making good of disturbed surfaces including all conduit fittings, clamps, gutties etc and one additional earth wire of 4.0 Sq mm but green in colour for earth DBs and boxes with proper thimbles thimbles connecting up and taking down old submain wiring complete all as specified and directed,.(Note : Two run of wire and one run of earth wire drown in PVC conduit of 20 mm dia shall be measured as one RM).
Supply and fixing sub-main wiring with two single core flame retardant PVC insulated and unsheathed cable with stranded copper conductor of 6 Sq mm drawing in & including medium grade PVC concealed conduit pipe 20 mm bore ISI marked with all accessories on walls and making good of disturbed surfaces including all conduit fittings, clamps, gutties etc and one additional earth wire of 6.0 Sq mm but green in colour for earth DBs and boxes with proper thimbles thimbles connecting up and taking down old submain wiring complete all as specified and directed.(Note : Two run of wire and one run of earth wire drown in PVC conduit of 20 mm dia shall be measured as one RM).
Material and labour in replacement of 3 mm thick 75 x 100 mm size laminated sheet cover ISI mamrked including cutting of holes for mounting, switches, sockets, fan regulator etc complete all as specified and directed and including taking down old fitment of existing sheet.
All as per item Ser No 49 but 100 x 100 mm laminated sheet cover with 04 Nos screw with washers complete all as specified and directed.
All as per item No 49 but 100 x 150 mm laminated sheet cover with 04 Nos screw with washers complete all as specified and directed.
All as per item No 49 but 150 x 200 mm laminated sheet cover with 04 Nos screw with washers complete all as specified and directed.
All as per item No 49 but 250 x 200 mm laminated sheet cover with 04 Nos screw with washers complete all as specified and directed.
Taking down old unsv earthing of any type and size but M & L for Renewal of Earthing with new earth electrod comprising of connected items like Earth electrode 17.2 mm dia 3 meter long of low carbon steel electrode with copper bonding of thickness, environment friendly backfill and suitable clamp, Back-fill earthing enhancing compound should strictly be a Carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE : 80 standard. Back-fill compound should be electronically conductive ( Like in metals ) and should not depend on moisture for conduction. Back-fill comound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. Back-fill compound shall not be mixed with any soil while pouring in the bore hole. Test Certificate as per as per IEC : 62561-7 for Back-fill compound shall be submitted along with the material including SS clamp to be provode both side complete all as specified and directed Note - (i) Earth electrode should be applicable Standards IS: 3043, IEC 62561-2 & IEC 60364-5 and made of High Tensile steel rods copper bounded, High tensile strength,good electrical conduction & effective performance and suitable for all type of soil and provided minimum distance 3 Mtrs. (ii) Back-fill compound should be Compliance to the Standards IEEE: 80, IS-3043, BS 7430, IEC 62561-7, ANSI/NSF 60 Certification.(iii) Positive low resistance electrical connection to the earth. (iv) Does not contain hazardous chemicals.(v) Electronically conductive (like in metals) and is not dependent on moisture. (v) Provide the desire value of earth resistance as per required specified values. (vi) Provide the Exothermic welding joints to entire grid system joints of earthing electrod. (vii) Test certificated to be provide of each electrod.
Taking down old unsv earthing of any type and size but M & L for earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of plate not less than 1.5 m below ground level connected to and including galvanised wire 4 mm dia (up or 7.5 mtr length) and GI pipe 40 mm light grade for protection of GI earth wore by means of bolts, nuts, checknuts and washers made out of galvanised iron and connected to earth test point as shown in electrical plate No. 3 of SSR Part-1-2009 and as specified or indicated and testing on completion including excavation and earth work any in type of strata available at site, PCC (1:3:6) type C-1 for earth chamber, precast RCC slab 50mm thick in cement concrete (1:2:4) type B-1 reinforced with welded steel wire fabric (xpm) weight not less the (4kg/sqm) funnel with GI watering pipe of 20mm bore medium grade, wire nuts and lugs including taking down old u/s one complete all as specified and as directed. Note:- On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
All as per item No-55 but using galvanised iron strip 25×4 mm as earthing lead
Taking down unsv earth continuity conductor of any type and size but S&F in replacement Earth continiuty conductor or main earthing lead fixed on wall on batten or recess or chases or buired in ground or drawn in conduit / pipe or fixed to wall up to test point / laying in below ground drown in GI tubing or any other indicated suituation for loop earthing etc, as required for galvanised iron wire 4 mm dia with proper saddles / spacer, screw etc, alll as specified and directed.
All as per item No 57 but 25×4 mm galvanised iron strip .
All as per item No 57 but 25×3 mm aluminium strip .
All as per item No 57 but 20x3 mm copper strip
Taking down any type and size of old unsv strip but M & L for Aluminium strip 25X3.15 mm wth saddels and fixing screws etc, for roof conductors and down conductors above ground with require connected items complete all as specified and as directed. Note : All joints of copper shall be of brazing only
All as per item No 61 but 20x3.15 mm copper strip
Taking down old/ unsv termination rod of any type and size but S&F in replacement of air termination single pointed aluminium rod of 12mm dia 300 mm long fixed to strip/pipe including drilling holes, nuts, bolts washers for resting/ supporting of air terminals etc. complete all as specified and as directed.
All as per item No 63 but copper rod.
Taking down old/ unsv test point of any type and size but S&F in repair test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25 to 32 mm long hex. head screw as suitable size complete all as specified and as directed.
Taking down serviceable rod and after cleaning and repair , refixing of air termiantion single pointed Aluminium rod 12mm dia 300 mm complete all as specified and as directed.
All as per item No 66 but copper rod.
Taking down serviceable strip and after cleaning and repair, refixing the same in repair Aluminium strip 25X3.15 MM wth saddels and fixing screws etc, for roof conductors and down conductors above ground with require connected items complete all as specified and as directed.
Taking down unsv any type and size of GI tubing but S&F in repair for 40 mm bore galvanised steel water tubing medium grade with all fitting laid in trenches for protection of earth continuity complete all as specified and as directed.
All as per item No 69 but of size 25 mm bore.
All as per item No 69 but of size 15 mm bore.
Taking down unsv any type and size of GI tubing but S&F in repair for 40 mm bore galvanised steel water tubing medium grade with all fitting fixed to wall and ceiling or laid in floors complete all as specified and as directed.
All as per item No 72 but of size 25 mm bore.
All as per item No 72 but of size 15 mm bore.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying pipe line and getting out in soft/loose soil complete all as specified and as directed.
Returning filling in including spreading leveling watering and well ramming in layers not exc 25cm thick with dry type of soil complete all as specified and as directed.
Removing excavated surplus soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and as directed.
Repairing and maintenance of old existing earth pit by taking out carefully earth plate, watering pipe, earth lead protection pipe and re-buried the same after removing sludge from the plate & pipes including re-connection/brazing the plate and strip, whichever is required at site (Earth pit not less than 2.25 mtr deep below normal ground level ) with top edge of earth plate not less than 1.5 metres below normal ground level,complete all as specified and directed including PCC 1:3:6 type C1 pit with cover of RCC 1:2:4 type B1,reinforced with welded steel wire fabric not less than 4 kg per sqmtrwith handle andangle iron frame,watering arrangment with 20 mm bore GI medium grade pipe ISI marked, GI funnel with GI mesh,filling with mixture of commen salt and charcoal,necessary excavation, refilling, removing away soil and earth work in any type of soil including test point, testing and commissioning complete all as specifed and as directed.Note : GI Funnel, brazing, mixture of salt/char coal/MGSO4 shall be measured and paid separately under releavant items.
Supply only of common salt commercial all as directed complete all as specified and as directed.
Supply only of charcoal dust complete all as specified and as directed.
Taking downn unsv funnel of any type and size but S&F in repair GI funnels for earthing complete all as specified and as directed.
M&L Powder Earthing Backfill Compound, Grade Standard for improvement earthing resistivity and to increase the absorption of moisture around the earthing electrode complete all as specified and directed.
M&L magnesium sulphate (MgSO4) for improvement earthing resistivity complete all as specified and directed.
M&L Brazing of copper/Aluminium/GI strip for continuity complete all as specified and as directed.
Taking down unsv chamber of any type and size but M&L for earthing chamber of size 0.45 x 0.45x 0.45 m and 100 mm thick by PCC 1:3:6 type C1 with 20 mm graded stone chamber with RCC 1:2:4 type B1 in cover slab complete all as specified and as directed.
Taking down unsv chamber cover of any type and size but M&L for earthing chamber cover of size 0.45 x 0.45x .04 m with RCC 1:2:4 type B-1 with 20 mm graded stone complete all as specified and as directed.
Taking down unsv CI cover of any type and size but S&F of CI pit cover of suitable of suitable size for existing earthing pit complete all as specified and as directed.
Material and labour for Testing of earth resistance value from earthing pit test terminal point and write in/ on existing identification board complete all as specified and as directed. Note:- (i) The contractor will arrange his own earth testing kit with connected items for testing of exisitng earth electrod complete.and will maintain Earth rasistance value ragister with signature of user /building charge costodian.
Supply and fixing single phase transparent hinges type Meter Box made up of Polycarbonate in suitable size of meter along with Cable entry from the bottom , water proof , temper proof, Pilferage proof, fire retardent transparent type and taking down the old exisitng meter and supply and fixing AC single phase static energy meter 240V, 50 Hzs backlite LCD dispaly of rating 5 to 30 Amp & with push button measures and display Kwh, KVAh, frequency,KW, six month history of energy meter meter shall be fixed into meter box connection testing complete all as specified Note :- Cost of items/accessorries required for fixing and make functional of meter shall be included in the qouted rates.
Supply and fixing single phase transparent hinges type Meter Box made up of Polycarbonate in suitable size of meter along with Cable entry from the bottom , water proof , temper proof, Pilferage proof, fire retardent transparent type and taking down the old exisitng meter and supply and fixing AC three phase static energy meter 3 x 240 V ,50 Hzs backlite LCD dispaly of rating 10 to 60 Amp & with push button measures and display Kwh,KVAh, frequency, KW, Six month history of energy meter shall be fixed into meter box connection testing complete all as specified Note :- Cost of items/accessorries required for fixing and make functional of meter shall be included in the qouted rates.
Supply and fixing Wall Mounted wired call bell indicator system 230 Volts LCD display , burzzer type tunner with sound range upto 50 meter the system shall be control upto 20 Nos Users ( patient bed) and wired connected to one bell push and other end to indivisual port of digital display call bell indicator panel etc complete all as specified.Note- (i) Bells push command to bell indivitual port of digital bell indicator panel and display to bed serial number. (ii) Bell control wire and bell push shall be paid separataly to respective items.(iii) Items/accessorries for installation of wired call indication system and make fully funtional shall be includes in qouted of item rates.
M&L XLPE insulated heavy duty electric cable of size 16 Sqmm 4 core with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall/pole and including taking down old unserviceable cable complete all as specified and directed of following sizes Note:- (i) Excavation & earth work, new sand, new bricks for cable protection shall be measured & paid seperatly in respective items here- in- before.
All as per Item No 92 but of size 10 Sqmm 4 core complete all as specified and directed
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable, foundation etc, and getting out in soft /loose soil complete all as specified and directed.
Returning filling in including spreading, leveling Watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983 and as directed. Note :- Excavated approved soil shall be ribbed by using sieve to separate composite particles etc as per IS and refiiling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is than gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness only will be considered for paymet.
M&L laying bricks 'B' class over a cable (Width wise) old liad dried complete all as specified and directed.
Material and labour for cutting of metallic road/ hard standing/hard rock/wall up to a size not exceeding 20cm width and not exceeding 60cm in depth for laying of protection pipe for cable including making good the disturbed road/hard standing by providing PCC (1:2:4) type B1, 40 mm grade crushed stone aggregate upto existing surface level or removing the any type of tiles carefully and refixing properly as per existing surface including suitable size of GI pipe (if necessary) complete all as specified and as directed by Engineer-in-charge.Note: 1. If damaged/broken the any type of tiles while removing, the contractor shall replace the broken tiles with new one.2. The Quoted rate is included for all materials/T&P/Machinery used in this item, no material can paid/measured separately.3. All the removable tiles/re fixable material shall kept carefully at a safe place for refixing with in this quoted rate.4. GI Pipe shall measured and paid separately under relevant item.
Disconnecting/Taking down defective storage type electrically operated water heater/geyser including disconnecting the water pipe (Cold and hot water) and electrical connection after unscrewing from the wall mounted hold/fastener etc. from the existing location and cleaning /descaling of scale formation in geysers inner tank assembly by means of scrubing with wire brush etc. including cleaning salvents etc and reassembling the geyser end plate/inspection plate and refixing in original position by hanging screwing with necessary nut bolts and washer and connecting up waters mains (Hot and cold) and necessary electric connection and testing on completion for proper working up to the entire satisfaction of user for its proper performance all as specified and directed.
Taking out the unserviceable heating element of capacity 1.5 KW of any make and S&F new heating element of capacity 1.5 KW all as specified and directed. Make : Roxy/Power Pack or equivalent.
All as per Serial Item No. 101 above but of 2 KW for geyser upto 50 Ltrs capacity. Make : Roxy/Power Pack or equivalent.
S&F in replacement of thermostat cut off switch suitable for electrical storage type water heater (geyser) upto 50 Ltrs complete all as directed. Make : Girish/Roxy/Klick
S&F in replacement of heavy stainless steel connection pipe with brass union fitted at both end suitable for connection to 15 mm GI pipe, 450 mm long for hot water including 01 No PVC washer on both ends.
All as per Serial Item No. 104 above but for cold water supply.
Repair of Geyser assembly complete with brazing of brass tube stud, nut bolts and copper tank for a length not exc 5.0 cm in each geyser.
S&F in replacement of neoprene rubber gasket for apparatus plate of inner tank assembly for any make /specifecation of electrical storage type water heater complete all as directed.
S&F in replacement of bottom plate cover of MS sheet to suit the geyser capacity 25 Ltrs including painting to the cover plate with 02 coat of white synthetic enameled paint over a coat of red oxide primer.
All as per Serial Item No. 108 above but for 50 Ltrs
All as per Serial Item No 108 above but new top covers of geyser capacity 25 Ltrs.
All as per Serial Item No. 108 above but new top covers of geyser capacity 50 Ltrs.
S&F in replacement of outer shell/body without bottom cover for 25 Ltrs capacity geyser made of MS sheets duly painted, complete all as directed.
All as per Serial Item No. 112 above but for geyser of capacity 50 Ltrs.
S&F in replacement of inner tank assembly made of copper sheet suitable for geyser of capacity 25 Ltr to match with any make and specifications of electirically operated water storage heater as per ground requirement/existing at site complete all as directed.
All as per Serial Item No. 114 above but for geyser of capacity 50 Ltrs.
S&F in replacement of inner assembly comprising of inlet and outler brass tubes to make syphon inner tank complete with base plate and necessary hardwares suitable for geyser of capacity 25 Ltr of any description/specification complete all as directed.
All as per Serial Item No. 116 above but for 50 Ltrs capacity geysers.
S&F in replacement of indicating lamp green and red in colour of geysers.
S&F in replacement of non return valve to geyser of 15 mm dia. Make :- Leader/ Shakti.
S&F in replacement of glass wool in geyser tank and taking out U/S glass wool as per sample.
S&F in replacement of switch socket combinations 3 pin 15 Amp, piano type.
S&F in replacement of plug top 3 pin 15 Amp.
S&F in replacement of industrial type MCB SP type metal clad plug and socket outlet comprising of MCB SP 16 Amp and making necessary electrical connection, complete all as specified and directed.
S&F in replacement of PVC flexible copper cable 3 core 2.5 sqmm for geyser cord.
S&F in replacement of Stop valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwd both ends iron pipe or for union and fixed of 15 mm dia.
S&F in replacement of fusible plug type safety cap for overheating protection suitable for electrically operated storage type water heater of capacity upto 50 Ltr of any specification/description, complete all as specified and directed
S&F in replacement of spring loaded safety valve suitable for electrically operated storage type water heater of capacity upto 50 Ltr of any specification/description, complete all as specified and directed
Supply and install connection testing commissioning of electric Geysers of capacity 25 Ltrs single phase 230 V AC incl required nut and bolts PVC water connection pipe complete all as specified and directed.
M&L for point wiring for using 2.5 sq mm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point including necessary running of 2.5 sq mm PVC insulated copper conductor FRLS cable as earth continuity conductor along with wiring and connecting to the common eath dolly with approved colour coding as per ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with frame suitable for modular switches all as specified and directed for the following :- (Note- Modular cover plate of any module with all fittings are included in point wiring.) Contractor should make good even distributed wall/surface as before.
All as per Serial Item No. 129 above but with copper conductor cable for one 3 pin socket outlet 15 Amp independent board with cable 4 Sqmm including one run of 2.5 Sqmm copper conductor as earth continuity wire, all as specified and directed.
M&L of Spray Painting of geyser after removing old paint and making surfaces smooth for repainting with super enamelled paint of same tint as of original all as required at site of any capacity.
Raj Construction
M/S Sahib N Sahiba Enterprises
M K Enterprises
M/S SHRI SHYAM BUILDERS
india trading company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .