Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.5 LAccepted-AOC | L1 | Accepted-AOC Lowest and reasonable | |
| 2 | L2₹62.8 L+₹8.3 L (15.2%)Rejected-Finance 191 ROHI BHARWARI KAUSHAMBI 212201 | KAUSHAMBI | KAUSHAMBI | UTTAR PRADESH | 212201 | L2 | Rejected-Finance Higher than L1 | |
| 3 | L3₹63.3 L+₹8.8 L (16.0%)Rejected-Finance 274 A 5TH LANE NISHATGANJ LUCKNOW UP PIN 226007 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226007 | L3 | Rejected-Finance Higher than L1 | |
| 4 | L4₹65.9 L+₹11.4 L (20.9%)Rejected-Finance 512 227 5TH LANE NISHANTGANJ LUCKNOW 226016 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226016 | L4 | Rejected-Finance Higher than L1 | |
| 5 | L5₹67.2 L+₹12.7 L (23.2%)Rejected-Finance | L5 | Rejected-Finance Higher than L1 |
Tender Value
₹60.5 L
EMD Value
₹1.2 L
Closing Date
28 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE
CWE AF BAMRAULI
PROVN OF DEF OTM ACCN FOR AIR DEFENCE WING AT HQ CAC AT AF STN BAMRAULI
2022_MES_561814_1
87215/E8
Open Tender
Civil Works
Item Rate
182 days
Bamrauli Allahabad
Class C category a i c i and other criteria as per NIT
8 documents required · 8 mandatory
₹1,000
GE AF BAMRAULI
₹1.2 L
Yes
1 Feb 2023
7 Nov 2022
5 Jan 2023
7 Nov 2022
28 Dec 2022
13 Dec 2022
7 Nov 2022 - 14 Nov 2022
Amount
Excavation in trenches, not exc.1.5 m wide and not exc. 1.5 m in depth for foundation, etc. or for shafts, wells, cesspits, cesspits, manholes, pier holes, etc. n. exc.10 Sq mm on plan, hard and n. exc. 1.5 m in depth and getting out for soft/loose soil.
Returning, filling in trenches incl spreading, leveling, watering and well ramming in layers not exc 25cm complete complete all as specified and directed.
Removing of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level n.exc 1.50 mtr above the starting point complete all as specified and directed.
Removing excavated soil to a distance exc 50mtr and upto a distance 250 mtr, depositing where directed at a level n.exc 1.50 mtr above the starting point complete all as specified and directed.
Removing excavated surplus soil exe 250 mtr but n exe 500m and depositing where directed at a level exe 1.50 mtr above the stating point etc complete all as specified and directed.
M & L PCC 1:4:8 type D-2 using 40mm grade stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M & L PCC 1:2:4 type B-1 using 20mm graded stone agg as in foundations of vertical post for shed including suttering and necessary earth work if requaired etc complete all as specified.
M & L PCC 1:2:4 type B-1 using 20mm graded aggregate of drain surface channel complete all as specified and directed.
M & L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in coping including necessary form work all as specified.
M & L PCC 1:3:6 type C1 using 20mm graded aggregate of drain surface channel complete all as specified and directed.
M&L bricks masonary with sub class `B’ brick built in CM (1:4) straight or curved on plan mean radius exceeding 6m complete all as specified and directed
M & L for Brick work using sub class 'B' bricks (old size) built in cement and sand mortar (1:6) straight or curved on plan exceeding 6 meter mean radius complete all as specified & directed.
M & L for rendering 15mm thick in cm (1:4) on fair faces of brick or concrete surface and even and smooth without using extra cement complete all as specified.
M&L rendering 15mm thick in CM 1:4 other than fair faces of brick / concrete surface of wall, finished even & fair complete all as specified and directed
Extra for fair finsihed drain or channel 30cm inner girth complete all as specified and directed.
M&L for add or deduct for each 25 mm girth or part there of over pr under 30 cm girth Complete all as specified and directed.
M&L for two coats of cement base paint on newly plastered /concrete surface of wall including preparation of surface over and including one coat of alkali resistance primer on plastered surfaces, complete all as specified and directed.
M & L for two coats of synthatic enamel paint over one coat of red oxide primer including preparation of new steel surfaces complete all as specified and directed.
S & F Solid PVC sheet coloured one side and other side white in wall lining / Paneling consisting of 5mm thick sheet including moulding on top , bottom , corner & edge complete and fixed with solvent adhesive / screw at site as per specification and drawing of SSR-II complete all as specified and directed. Note : Colour and design of prelaminated solid PVC sheet shall be approved by GE.
S & F solid PVC sheet white coloured wall fillet frame consisting of 35 X 5mm thick @ 300mm C/C vertical distance white coloured PVC sheet and horizontal top , bottom , corner & edge complete and fixed with solvent adhesive / screw at site as per specification and drawing of SSR-II complete all as specified and directed.
S&F MS powder coated Steel work in tubular/square/ractangular section as in partition / grid work ceiling and similar work including special shaped washer etc. Complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed.
S&F 10mm thick toughened glass as in partitions and similar work including made to required shape including drilling holes complete all as specified & directed.
S&F Wood Plastic Composite (WPC) board 08mm thick, high density grade as in partitions and similar work including cutting to shape etc as required complete all as specified & directed.
S&F Wood Plastic Composite (WPC) board 06mm thick, high density grade as in partitions/ceiling and similar work including cutting to shape etc as required complete all as specified & directed.
S&F powder coated anodised aluminium door shutters of any colour (Thickness of powder coating not less than 50 micron), aluminium section weight 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified as directed.
S & F 6.30mm Sheet glass, ordinary quality and glazing with aluminium beads complete all as specified as directed.
S & F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular tions/ appropriate Z sections and other sections, conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at op, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, luminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.
S & F MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment complete all as specified and directed.
S & F MS expansion bolt 12mm dia and 150mm long including drilling wall and floor for fixing complete all as specified and directed.
S & F 0.50mm thick pre-painted coloured Glavalume aluminium zinc coating GI based corrugated steel sheet of having tensile strength of 550 Mpa as in roofing, fixed with self tapping screws etc complete all as specified and directed. ) Note : Sheet shall be Korea blue colour at toop & stand gray colour at bottom).
S & F 0.50mm thick pre-painted coloured Galvalume aluminium zinc coating GI based plain sheet as in valley gutter, ridges, hips etc, steel sheet having tensile strength of 550 Mpa as in roofing, fixed with self tapping screws etc complete all as specified and directed. Note : (Sheet shall be Korea blue colour at top & stand gray colour at bottom).
S & F rolled MS section framing work as in vertical post fixed with angle cleat and connecting plate,cladding etc including necessary reveting welding drilling fitting etc complete all as specified & directed.
S & F Mild steel struts in fencing including cutting tops to shade as directed, drilling holes , notching for wire etc flat iron fillets nut bolt ( for securing wire mesh etc ) including all necessary drilling , bolting or riveting etc and similar work conforming to Fe-290 Gde E-165 etc fixing in wall complete all as specified and directed.
S & F rolled MS angle iron framed work for roof trusses as in main and cross beams hip and jack rafter, purlin incl distance pices where connected to common rafters and running rails and fixed with angle cleats or other connecting plates incl necessary reveting welding drilling fitting complete all as specified.
M & L for Rolled mild steel Fe-410W (Gde E-250) quaility A in farmed work as in door or gate of angle or other section with gusser plates rails,braces etc, complete drilled for fixing of steel sheeting or other covering including steel pintal hinges, rollers and locking arrangement and fixed complete with RCC Pillar all as specified and directed.
Supply, installation, commissioning and testing LT panel board cubical outdoor type floor mounted, factory made 3.15mm MS sheet, conforming to IP-54, with front and back hinges door with proper locking arrangement, rubber gasket on front and back to make it dust and vermin proof and painted powder coated including 600 Amp rated copper bus bar , 3 phase 4 wire system and wiring with suitable size of copper cable comprising and suitable foundation & following accessories :-
Supply & Laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 300 sqmm 3.5 Core complete all as specified and directed
Supply, install, testing and commissioning of maintenance free chemical earth pit (Tripod Chemical Earthing) made of “Grid” chemical earth enhancing, non ferrous compound containing no carbon or graphite and including following M & L (i) Three Nos 3000mm long 50mm dia copper bonded “Earth Electrode” prefilled with compound and stainless steel fasters, HDPE lockable earthpit cover cum inspection chamber along with 150 Kgs of Earth Enhancement, high conductive, corrosion resistant, non ferrous compound containing no carbon or graphite including bore hole of 150-200 mm and depth upto 3.3 mtr (ii) Copper earthing strip 50x5mm for interconnection of all three pits alongwith necessary clamps and nuts bolts. (iii) Any other accessories including design modification to achieve the required earth termination rod resistance valve below 1 ohms or as per the OEM/International Standard recommendation (iv) Mark earth result and date with paint (v) Copper strip upto 7.5 mtr for test point is included in the job.
Supply and Laying of down conductor ISI marked 70 sq. mm PVC insulated copper flexible conductor including both end termination, suitable size cable clamps cooper thimbles etc from Equipment to the Earth pit terminal / Earth test link complete all as specified and directed.
Supply and fix Test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 nos. 8mm dia 25 mm long hex head screw complete all as specified and directed.
Supply and fix copper strip size 50 x 5mm buried in ground or fixed and on wall complete all as specified and directed.
Supply and spreading clean and dry screened sand (unwashed) in trenches around the cable for cushioning complete all as specified and directed by Engineer-in-Charge. Note :- Punned thickness shall be measured (total depth of sand shall be 18cm after ramming).
M&L for providing old size sub class 'B' bricks laid perpendicular to the cable abutting each other complete all as specified and directed.
Designing, Supplying, installing, testing and commissioning of 24 Ton air cooled 100% inverter single compressor based variable refrigerant flow (VRF) modular type air conditioning system suitable for R410 A refrigerant, 400V, 3 phase, 50 Hz AC along with multi indoor units, external condensing units, fresh air unit, copper refrigerant pipe, upvc drain pipe, transmission cum control copper wiring, cordless remote controls, MS slotted angle irons, etc including indoor cassette type unit 6 Nos 4 tonne capacity as per specification of OEM. Following items to be provided by the bidder :-
(a) Outdoor condensing units equipped with highly efficient 100% inverter compressors with low noise condenser fan with DC motor, auto check function for connection error, auto address setting of 24 Ton capacity. (b) Connection kit required at site all as per OEM recommendation or as directed by EIC (c) Cordless remote controls for each indoor unit /cassette suitable for air conditioning system all as recommended by OEM (d) Refrigerant joints fittings all as required at site and as per OEM recommendation (e) Copper refrigerant piping for interconnection between each set of indoor units and outdoor units duly insulated with closed cell elastomeric nitrile rubber tubular insulation all as required on site and as per OEM recommendation and the drawing for copper refrigerant pipe to be submit by contractor duly approved by accepting officer before the start of the work.
(g) 32mm dia UPVC drain piping for indoor units complete with necessary elbow tees reducers etc duly insulation with 6mm thick closed cell elastomeric nitrile rubber tubic/sheet rapin complete all as required on site of size 32 mm dia. (h) Controlled cum transmission shielded copper wiring suitable of connection between indoor and outdoor units all as recommended by OEM and required at site of 2 core 1.5sqmm. (j) M&L for PCC (1:3:6) 20mm graded stone aggregate suitable for outdoor unit of size (1.5m X 1.5m X 0.9m) all as specified and directed. (k) M&L for MS base frame, factory fabricated suitable for outdoor units duly painted with weather protective paint floor mounted table top type all outdoor units all as required at site and directed by EIC. (l) M&L for MS slotted channel of size 40x40x6mm for support of refrigerant piping, transmission wiring and drain pipes complete all as specified and directed. (m) Pressure testing and charging of refrigerant R410A gas above mention air conditioning plant complete as required at site and as recommended by OEM. (n) Material and labour for 3 core PVC FRLS cable and MCB SP for power supply to indoor units from LT Panel complete as required at site and recommended by OEM.
Note :- Following specification to be follow for VRF AC Plant. Note (i) For maintaining inside temperature (25+3) Degree Celsius and RH (50+10)% and technical parameters as per Annexure 'A' and design data as per Annexure 'B' attached of air defence wing Bldg at AF station Bamrauli. (ii) Provision of winter heating arrangement as per OEM as required at site for maintaining inside specified temp and humidity complete with indoor and outdoor unit with individual controller for cooling and heating type operations (Heat recovery Ventilation System) all specified and directed by Engr-in-Charge. (ii) The tenderer should get the plant installed only by any one of the original manufacturer viz Blue Star/Carrier/Hitachi with their own makes or with their recommended makes of complete components/ items. Provn of combination of various items/ components of different manufacturer of above or their recommended makes or any other makes is not acceptable.
Supply and install, testing of 3 TR vertical tower type air cooled pack type indoor/outdoor complete with cordless remote control unit, rotary compressor, single phase 220 V, 50 Hz, minimum 3 star rating, refrigerant R-134/410/32 complete electric connections and testing complete all as specified and directed. Make - Blue Star/Carrier/Hitachi
Supply and laying of copper tubing size 3/8" for tower AC all as specified and directed by the Engineer-in-charge.
Supply and laying of copper tubing size 1/2" for tower AC all as specified and directed by the Engineer-in-charge.
Supply and fix voltage stabilizer 5KVA 230V, Single phase, 50 Hz with wall mounting arrangement all as specified and directed by the Engineer-in-charge.
S & F water condensing heavy duty UPVC pipe 20mm dia with fitting all as specified and directed by the Engineer-in-charge.
Z N Enterprises
M/S S.B. Singh and Sons
Divya Jyoti Constructions
M K Engineers and Contractors
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .